At least 1,045 records · Page 58

Electronic band structure effects in the stopping of protons in copper [Electronic band structure non-linear effects in the stopping of protons in copper]

Here, we present an ab initio study of the electronic stopping power of protons in copper over a wide range of proton velocities v = 0.02–10a.u. where we take into account nonlinear effects. Time-dependent density functional theory coupled with molecular dynamics is used to study electronic excitations produced by energetic protons. A plane-wave pseudopotential scheme is employed to solve the time-dependent Kohn-Sham equations for a moving ion in a periodic crystal. The electronic excitations and the band structure determine the stopping power of the material and alter the interatomic forces for both channeling and off-channeling trajectories. Our off-channeling results are in quantitative agreement with experiments, and at low velocity they unveil a crossover region of superlinear velocity dependence (with a power of ~1.5) in the velocity range v = 0.07–0.3a.u., which we associate to the copper crystalline electronic band structure. The results are rationalized by simple band models connecting two separate regimes. We find that the limit of electronic stopping v → 0 is not as simple as phenomenological models suggest and it is plagued by band-structure effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electronic structure and 4$f$-electron character in Ce 2 PdIn 8 studied by angle-resolved photoemission spectroscopy

The localized-to-itinerant transition of $f$ electrons lies at the heart of heavy-fermion physics, but has only been directly observed in single-layer Ce-based materials. Here, we report a comprehensive study on the electronic structure and nature of the Ce 4$f$ electrons in the heavy-fermion superconductor Ce 2 PdIn 8 , a typical n = 2 Ce n MmIn 3n+2m compound, using high-resolution and 4$d$–4$f$ resonant photoemission spectroscopies. The electronic structure of this material has been studied over a wide temperature range, and hybridization between f and conduction electrons can be clearly observed to form a Kondo resonance near the Fermi level at low temperatures. Here, the characteristic temperature of the localized-to-itinerant transition is around 120 K, which is much higher than its coherence temperature T coh ~ 30K.

36 MATERIALS SCIENCE↗

Electron ionization via dark matter-electron scattering and the Migdal effect

There are currently several existing and proposed experiments designed to probe sub-GeV dark matter (DM) using electron ionization in various materials. The projected signal rates for these experiments assume that this ionization yield arises only from DM scattering directly off electron targets, ignoring secondary ionization contributions from DM scattering off nuclear targets. We investigate the validity of this assumption and show that if sub-GeV DM couples with comparable strength to both protons and electrons, as would be the case for a dark photon mediator, the ionization signal from atomic scattering via the Migdal effect scales with the atomic number Z and 3-momentum transfer q as Z 2 q 2 . The result is that the Migdal effect is always subdominant to electron scattering when the mediator is light, but that Migdal-induced ionization can dominate over electron scattering for heavy mediators and DM masses in the hundreds of MeV range. We put these two ionization processes on identical theoretical footing, address some theoretical uncertainties in the choice of atomic wave functions used to compute rates, and discuss the implications for DM scenarios where the Migdal process dominates, including for XENON10, XENON100, and the recent XENON1T results on light DM scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Core Electrons in the Electronic Stopping of Heavy Ions

Electronic stopping power in the keV / Å range is accurately measured from first principles for high atomic-number projectiles and the effect of core states is carefully assessed. The energy loss to electrons in self-irradiated nickel is researched using real-time time-dependent density functional theory. Different core states are explicitly included in the simulations to understand their involvement in the dissipation mechanism. The core electrons of the projectile are found to open additional dissipation channels as the projectile velocity increases. Almost all of the energy loss is accounted for, even for high projectile velocities, when core electrons as deep as 2s 2 2p 6 are explicitly treated. In addition to their expected excitation at high velocities, a flapping dynamical response of the projectile core electrons is observed at intermediate velocities. The empirical reference data are well reproduced in the projectile velocity range of 1.0–12.0 a.u. (1.5–210 MeV).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectroscopic Evidence for Electron-Boson Coupling in Electron-Doped Sr 2 IrO 4

The pseudogap, d-wave superconductivity and electron-boson coupling are three intertwined key ingredients in the phase diagram of the cuprates. Sr 2 IrO 4 is a 5d-electron counterpart of the cuprates in which both the pseudogap and a d-wave instability have been observed. Here, we report spectroscopic evidence for the presence of the third key player in electron-doped Sr 2 IrO 4 : electron-boson coupling. A kink in nodal dispersion is observed with an energy scale of ~50 meV. The strength of the kink changes with doping, but the energy scale remains the same. Furthermore, these results provide the first noncuprate platform for exploring the relationship between the pseudogap, d-wave instability, and electron-boson coupling in doped Mott insulators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using Direct Laboratory Measurements of Electron Temperature Anisotropy to Identify the Heating Mechanism in Electron-Only Guide Field Magnetic Reconnection

Anisotropic electron heating during electron-only magnetic reconnection with a large guide magnetic field is directly measured in a laboratory plasma through in situ measurements of electron velocity distribution functions. Electron heating preferentially parallel to the magnetic field is localized to one separatrix, and anisotropies of 1.5 are measured. The mechanism for electron energization is identified as the parallel reconnection electric field because of the anisotropic nature of the heating and spatial localization. These characteristics are reproduced in a 2D particle-in-cell simulation and are also consistent with numerous magnetosheath observations. A measured increase in the perpendicular temperature along both separatrices is not reproduced by our 2D simulations. Here, this work has implications for energy partition studies in magnetosheath and laboratory reconnection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray and electron spectroscopy of (photo)electrocatalysts: Understanding activity through electronic structure and adsorbate coverage

Electronic structure plays a critical role in the kinetics of (photo)electrocatalytic reactions. X-ray and electron spectroscopies provide key determinants—electronic structure, surface adsorbate speciation and coverage quantification, valence state, coordination chemistry, etc.—of catalytic activity and selectivity. Here, we provide an introduction to the fundamental physical concepts, capabilities, and limitations of x-ray photoelectron spectroscopy, x-ray absorption spectroscopy, and electron energy-loss spectroscopy as well as provide discussions of (photo)electrocatalysis-relevant publications utilizing each of these techniques. Our objective is to provide those new to x-ray and electron spectroscopies with sufficient information to assess which techniques probe desired material parameters, while also providing experts in each of these spectroscopic fields a bridge to view the importance of these spectroscopies to (photo)electrocatalysis research.

Carvalho, Oliver Quinn (ORCID:0000000344205203)↗

SU-E-T-356: Accuracy of Eclipse Electron Macro Monte Carlo Dose Algorithm for Use in Bolus Electron Conformal Therapy

Purpose: To evaluate the accuracy of electron dose distribution calculated by the Varian Eclipse electron Monte Carlo (eMC) algorithm for use with recent commercially available bolus electron conformal therapy (ECT). Methods: eMC-calculated electron dose distributions for bolus ECT have been compared to those previously measured for cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV CT anatomy for each site. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The bolus ECT treatment plans were imported into the Eclipse treatment planning system and calculated using the maximum allowable histories (2×10{sup 9}), resulting in a statistical error of <0.2%. Smoothing was not used for these calculations. Differences between eMC-calculated and measured dose distributions were evaluated in terms of absolute dose difference as well as distance to agreement (DTA). Results: Results from the eMC for the retromolar trigone phantom showed 89% (41/46) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of −0.12% with a standard deviation of 2.56%. Results for the nose phantom showed 95% (54/57) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of 1.12% with a standard deviation of 3.03%. Dose calculation times for the retromolar trigone and nose treatment plans were 15 min and 22 min, respectively, using 16 processors (Intel Xeon E5-2690, 2.9 GHz) on a Varian Eclipse framework agent server (FAS). Results of this study were consistent with those previously reported for accuracy of the eMC electron dose algorithm and for the .decimal, Inc. pencil beam redefinition algorithm used to plan the bolus. Conclusion: These results show that the accuracy of the Eclipse eMC algorithm is suitable for clinical implementation of bolus ECT.

60 APPLIED LIFE SCIENCES↗

Electron and photon energy calibration with the ATLAS detector using LHC Run 1 data

This paper presents the electron and photon energy calibration achieved with the ATLAS detector using about 25 fb -1 of LHC proton–proton collision data taken at centre-of-mass energies of √s=7 and 8 TeV. The reconstruction of electron and photon energies is optimised using multivariate algorithms. The response of the calorimeter layers is equalised in data and simulation, and the longitudinal profile of the electromagnetic showers is exploited to estimate the passive material in front of the calorimeter and reoptimise the detector simulation. After all corrections, the Z resonance is used to set the absolute energy scale. For electrons from Z decays, the achieved calibration is typically accurate to 0.05 % in most of the detector acceptance, rising to 0.2 % in regions with large amounts of passive material. The remaining inaccuracy is less than 0.2–1 % for electrons with a transverse energy of 10 GeV, and is on average 0.3 % for photons. The detector resolution is determined with a relative inaccuracy of less than 10 % for electrons and photons up to 60 GeV transverse energy, rising to 40 % for transverse energies above 500 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved control of electron computer-generated holographic grating groove profiles using ion beam gas-assisted etching

In a transmission electron microscope, electrons are described by matter-waves with wavelengths five orders of magnitude smaller than optical electromagnetic waves. Analogous to optical holography, electron wavefronts can be shaped using nanoscale holographic gratings. Here we demonstrate a novel, scalable nanofabrication method for creating off-axis holographic gratings that demonstrate near ideal diffraction efficiencies for binary, sinusoidal, and blazed grating groove profiles. We show that this method can produce up to 50 µm diameter area gratings that diffract up to 68% of the transmitted electron wave into a desired diffraction order with less than 7% into any other order. Additionally, we find that the amount of inelastically scattered electrons from the material gratings remaining in the coherent diffraction orders from the gratings is negligible in the far field.

Johnson, Cameron W.↗

Revealing momentum-dependent electron–phonon and phonon–phonon coupling in complex materials with ultrafast electron diffuse scattering

Abstract Despite their fundamental role in determining many important properties of materials, detailed momentum-dependent information on the strength of electron–phonon and phonon–phonon coupling across the entire Brillouin zone has remained elusive. Ultrafast electron diffuse scattering (UEDS) is a recently developed technique that is making a significant contribution to these questions. Here, we describe both the UEDS methodology and the information content of ultrafast, photoinduced changes in phonon-diffuse scattering from single-crystal materials. We present results obtained from Ni, WSe 2 , and TiSe 2 , materials that are characterized by a complex interplay between electronic (charge, spin) and lattice degrees of freedom. We demonstrate the power of this technique by unraveling carrier–phonon and phonon–phonon interactions in both momentum and time and following nonequilibrium phonon dynamics in detail on ultrafast time scales. By combining ab initio calculations with ultrafast diffuse electron scattering, insights into electronic and magnetic dynamics that impact UEDS indirectly can also be obtained. Graphic Abstract

Dürr, Hermann A. (ORCID:0000000196808730)↗

Demonstration of Electron Cooling using a Pulsed Beam from an Electrostatic Electron Cooler

Electron cooling continues to be an invaluable technique to reduce and maintain the emittance in hadron storage rings in cases where stochastic cooling is inefficient and radiative cooling is negligible. Extending the energy range of electron coolers beyond what is feasible with the conventional, electrostatic approach necessitates the use of RF fields for acceleration and, thus, a bunched electron beam. To experimentally investigate how the relative time structure of the two beams affects the cooling properties, we have set up a pulsed-beam cooling device by adding a synchronized pulsing circuit to the conventional electron source of the CSRm cooler at Institute of Modern Physics *. We show the effect of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrate the detrimental effect of timing jitter as predicted by theory and simulations. Compared to actual RF-based coolers, the simplicity and flexibility of our setup will facilitate further investigations of specific aspects of bunched cooling such as synchro-betatron coupling and phase dithering.

Bruker, M. W.↗

High Pressure Electron Gun for Electron Beam Welding and Additive Manufacturing

Electron beam welding is a premier technology for high quality welding. However, e-beam welding is viewed as very expensive method for quality results. Therefore, it is often the last choice for joining metals. U.S. Electron is developing a technology that changes the welding environment. As a result of this pursuit of technology, e-beam welding can be field deployable. U.S. Electron has received a DOE SBIR Phase I grant to demonstrate a proof of principle that the plasma cathode can be installed in an electron gun housing, generate a current and energy enough to weld stainless steel. Under this CRADA, Fermilab proposed to provide a power supply, the necessary safety expertise and the physical location for testing of the initial prototype equipment developed by U.S. Electron.

43 PARTICLE ACCELERATORS↗