Membrane contactor assisted water extraction system for separating hydrogen peroxide from a working solution, and method thereof

The present invention relates to a membrane contactor assisted extraction system and method for extracting a single phase species from multi-phase working solutions. More specifically one preferred embodiment of the invention relates to a method and system for membrane contactor assisted water (MCAWE) extraction of hydrogen peroxide (H.sub.2O.sub.2) from a working solution.

47 OTHER INSTRUMENTATION↗

Extracting Short Rise-Time Velocity Profiles with Digital Down-Shift Analysis of Optically Up-Converted PDV Data

This work describes the digital down-shift (DDS) technique, a new method of extracting short rise-time velocity profiles in the analysis of optically up-converted PDV data. The DDS technique manipulates the PDV data by subtracting a constant velocity (i.e., the DDS velocity νDDS) from the velocity profile. DDS exploits the simple fact that the optically up-converted data ride on top of a base velocity (ν0, the apparent velocity at no motion) with a rapid rise to a high velocity (νf) of a few km/s or more. Consequently, the frequency content of the signal must describe a velocity profile that increases from ν0 to ν0 + νf. The DDS technique produces velocity reversals in the processed data before shock breakout when ν0 < νDDS < ν0 + νf. The DDS analysis process strategically selects specific DDS velocities (velocity at which the user down shifts the data) that produce anomalous reversals (maxima and/or minima), which are predictable and easy to identify in the mid-range of the data. Additional analysis determines when these maxima and minima occur. By successive application of the DDS technique and iterative analysis, velocity profiles are extracted as time as a function of velocity rather than as a function of time as it would be in a conventional velocity profile. Presented results include a description of DDS, velocity profiles extracted from laser-driven shock data with rise times of 200 ps or less, and a comparison with other techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid extraction of short-lived isotopes from a buffer gas cell for use in gas-phase chemistry experiments, Part II: On-line studies with short-lived accelerator-produced radionuclides

We report a novel combination of advanced gas-chromatography and detection systems coupled to a buffer-gas cell was characterized on-line to allow gas-phase chemical studies of accelerator-produced short-lived α -decaying mercury, francium, and astatine isotopes. These were produced in 40 Ar- and 48 Ca-induced nuclear fusion–evaporation reactions, subsequently isolated in the recoil separators MARS at Texas A&M University, USA, and TASCA at GSI Darmstadt, Germany, before being thermalized in a buffer-gas-stopping cell. From the latter, the nuclear reaction products were extracted into gas-phase chromatographic systems, suitable for registering α-decaying short-lived radionuclides, such as isotopes of superheavy elements. Efficiencies of 21(3)% for 204-209 Fr were reached for the extraction into the optimized miniCOMPACT gas-chromatography setup, indicating that this technique enables the identification of isotopes of volatile as well as non-volatile elements. These studies guide the path towards chemical investigations of superheavy elements beyond flerovium, which are out of reach with currently used setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion energy distribution functions of low energy beams formed by wire extraction electrodes

The two-electrode extractor system made of 0.1 mm diameter tungsten wires separated by 0.7 mm has formed an argon ion beam with 50 V extraction potential. Energy spreads of the extracted beams were typically less than 2 eV when the beam current density was low. The beam intensity rapidly decreased as the distance between the extractor and the beam detector increased, indicating space charge limited transport of the beam. Problems associated with the emittance measurements are also discussed.

43 PARTICLE ACCELERATORS↗

Next Generation Solvent (NGS): Development for Caustic-Side Solvent Extraction of Cesium

This report summarizes the FY 2010 and 2011 accomplishments at Oak Ridge National Laboratory (ORNL) in developing the Next Generation Caustic-Side Solvent Extraction (NG-CSSX) process, referred to commonly as the Next Generation Solvent (NGS), under funding from the U.S. Department of Energy, Office of Environmental Management (DOE-EM), Office of Technology Innovation and Development. The primary product of this effort is a process solvent and preliminary flowsheet capable of meeting a target decontamination factor (DF) of 40,000 for worst-case Savannah River Site (SRS) waste with a concentration factor of 15 or higher in the 18-stage equipment configuration of the SRS Modular Caustic-Side Solvent Extraction Unit (MCU). In addition, the NG-CSSX process may be readily adapted for use in the SRS Salt Waste Processing Facility (SWPF) or in supplemental tank-waste treatment at Hanford upon appropriate solvent or flowsheet modifications. Efforts in FY 2010 focused on developing a solvent composition and process flowsheet for MCU implementation. In FY 2011 accomplishments at ORNL involved a wide array of chemical-development activities and testing up through single-stage hydraulic and mass-transfer tests in 5-cm centrifugal contactors. Under subcontract from ORNL, Argonne National Laboratory (ANL) designed a preliminary flowsheet using ORNL cesium distribution data, and Tennessee Technological University confirmed a chemical model for cesium distribution ratios (DCs) as a function of feed composition. Interlaboratory efforts were coordinated with complementary engineering tests carried out (and reported separately) by personnel at Savannah River National Laboratory (SRNL) and Savannah River Remediation (SRR) with helpful advice by Parsons Engineering and General Atomics on aspects of possible SWPF implementation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

4D Emittance Measurements Using Multiple Wire and Waist Scan Methods in the ATF Extraction Line

Emittance measurements performed in the diagnostic section of the Accelerator Test Facility (ATF) extraction line since 1998 led to vertical emittances three times larger than the expected ones, with a strong dependence on intensity. An experimental program is pursued to investigate potential sources of emittance growth and find possible remedies. This requires efficient and reliable emittance measurement techniques. In the past, several phase-space reconstruction methods developed at SLAC and KEK have been used to estimate the vertical emittance, based on multiple location beam size measurements and dedicated quadrupole scans. These methods have been shown to be very sensitive to measurement errors and other fluctuations in the beam conditions. In this context new emittance measurements have been performed revisiting these methods and newly developed ones with a systematic approach to compare and characterise their performance in the ATF extraction line.

43 PARTICLE ACCELERATORS↗

Life Extension Program for the Modular Caustic Side Solvent Extraction Unit at Savannah River Site - 13179

Caustic Side Solvent Extraction (CSSX) is currently used at the U.S. Department of Energy (DOE) Savannah River Site (SRS) for removal of cesium from the high-level salt-wastes stored in underground tanks. Currently, the Actinide Removal Process (ARP) and the CSSX process are deployed in the (ARP)/Modular CSSX Unit (MCU), to process salt waste for permanent disposition. The CSSX technology utilizes a multi-component organic solvent and annular centrifugal contactors to extract cesium from alkaline salt waste. The original plant was permitted for a three year design life; however, given the successful operation of the plant, a life extension program was completed to continue operations. The program included detailed engineering analyses of the life-expectancy of passive and active components, resulting in component replacement and/or maintenance and monitoring program improvements. The program also included a review of the operations and resulted in a series of operational improvements. Since the improvements have been made, an accelerated processing rate has been demonstrated. In addition, plans for instituting a next-generation solvent are in place and will enhance the decontamination factors. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrological Drought in the Anthropocene: Impacts of Local Water Extraction and Reservoir Regulation in the U.S.

Hydrological drought is a substantial negative deviation from normal hydrologic conditions and is influenced by climate and human activities such as water management. By perturbing the streamflow regime, climate change and water management may significantly alter drought characteristics in the future. Here we utilize a high-resolution integrated modeling framework that represents water management in terms of both local surface water extraction and reservoir regulation, and use the Standardized Streamflow Index (SSI) to quantify hydrological drought. We explore the impacts of water management on hydrological drought over the contiguous US in a warming climate with and without emissions mitigation. Despite the uncertainty of climate change impacts, local surface water extraction consistently intensifies drought that dominates at the regional to national scale. However, reservoir regulation alleviates drought by enhancing summer flow downstream of reservoirs. The relative dominance of drought intensification or relief is largely determined by the water demand, with drought intensification dominating in regions with intense water demand such as the Great Plains and California, while drought relief dominates in regions with low water demand. Here, at the national level, water management increases the spatial extent of extreme drought despite some alleviations of moderate to severe drought. In an emissions mitigation scenario with increased irrigation demand for bioenergy production, water management intensifies drought more than the business-as-usual scenario at the national level, so the impacts of emissions mitigation must be evaluated by considering its benefit in reducing warming and evapotranspiration against its effects on increasing water demand and intensifying drought.

54 ENVIRONMENTAL SCIENCES↗

Improved Light Extraction in Organic Light‐Emitting Diodes via Semiconductor Dilution

Increasing the internal light extraction efficiency of organic light‐emitting diodes (OLEDs) is key to improving their performance for solid‐state lighting applications; however, it is challenging to do this in a way that is compatible with high volume manufacturing. Here, it is shown that the outcoupling efficiency of OLEDs can be improved by diluting their hole transport layer (HTL) with the low refractive index material trifluoropropyl oligomeric silsesquioxane (F‐POSS). Specifically, co‐evaporating 40 vol.% F‐POSS in the HTL of single and multi‐stack phosphorescent OLEDs decreases its refractive index by Δ n ≈ 0.2, which in turn yields a ≈12% increase in their outcoupling efficiency with no impact on electrical performance or operational lifetime. This result is significant because F‐POSS is a small molecule that sublimes cleanly, does not aggregate, and is compatible with state‐of‐the‐art HTL materials, making it a realistic path to increase light extraction in commercial OLEDs manufactured on existing production lines.

36 MATERIALS SCIENCE↗

A Polymer Hole Extraction Layer for Inverted Perovskite Solar Cells from Aqueous Solutions

Poly(Phenylene vinylene) anionic polyelectrolyte (PVBT-SO 3 ) was found to be an efficient hole extraction layer for inverted perovskite solar cells. It can be cast from an aqueous solution and does not require thermal annealing for improved device performance. The devices show maximum solar cell efficiency of 15.9% and exhibit improved stability under ambient conditions and enhanced charge extraction.

14 SOLAR ENERGY↗

Highly Efficient and Uniform 1 cm 2 Perovskite Solar Cells with an Electrochemically Deposited NiO x Hole-Extraction Layer

Here, given that the highest certified conversion efficiency of the organic-inorganic perovskite solar cell (PSC) already exceeds 22%, which is even higher than that of the polycrystalline silicon solar cell, the significance of new scalable processes that can be utilized for preparing large-area devices and their commercialization is rapidly increasing. From this perspective, the electrodeposition method is one of the most suitable processes for preparing large-area devices because it is an already commercialized process with proven controllability and scalability. Here, a highly uniform NiO x layer prepared by electrochemical deposition is reported as an efficient hole-extraction layer of a p-i-n-type planar PSC with a large active area of >1 cm 2 . It is demonstrated that the increased surface roughness of the NiO x layer, achieved by controlling the deposition current density, facilitates the hole extraction at the interface between perovskite and NiO x , and thus increases the fill factor and the conversion efficiency. The electrochemically deposited NiO x layer also exhibits extremely uniform thickness and morphology, leading to highly efficient and uniform large-area PSCs. As a result, the p-i-n-type planar PSC with an area of 1.084 cm 2 exhibits a stable conversion efficiency of 17.0% (19.2% for 0.1 cm 2 ) without showing hysteresis effects.

14 SOLAR ENERGY↗

Continuous Counter‐Current Microfluidic Liquid–Liquid Extraction Achieved Using a Pair of Wettable Screen Meshes

Continuous counter‐current microfluidic liquid–liquid extraction performs separations by flowing immiscible liquids in opposing directions within a single flow channel. In principle, this flow arrangement enables a large number of theoretical separation units in a small footprint, without using interstage valving, pumping, and phase separation. Despite its potential for excellent separation performance, this microfluidic scheme rarely appears in literature due to the requirement for capillary forces to be greater than hydrodynamic forces for stable flow. We present a novel microfluidic device and flow approaches that overcome this force‐balance challenge, enabling stable, long‐duration continuous counter‐current flow. Additionally, we cover a suite of methodologies for quantifying the performance of the microfluidic device, revealing the number of theoretical equilibrium stages achieved. The enabling technologies include a woven mesh screen‐based microfluidic device architecture that is easily fabricated outside of a clean room, surface functionalization strategies to promote conjugate (organic/aqueous) wettability, flow approaches to eliminate bubbles and carryover, and computer‐aided flow automation with optical measurement of extraction performance. The reported experiments lasted for over 36 h, terminated only at experiment conclusion, where the device still exhibited good performance. Automated Raman spectroscopy was used for solute quantitation of the ternary system tert‐butanol in a toluene/water matrix, a ternary system that was specifically chosen to analyze the device's performance with a small solute partition ratio and to enable in‐line Raman measurements of solute concentrations in both phases. The microfluidic device possessed a 55 mm contact length and a 38.5 µL internal volume. During counter‐current flow, we observed approximately 37 equilibrium stages (37 ± 13) based on a best‐fit of the solute fraction remaining in the aqueous phase using a Kremser Group Method analysis.

36 MATERIALS SCIENCE↗

Quantum chemistry benchmarking of binding and selectivity for lanthanide extractants

Computer-aided screening methods facilitate the discovery of new extractants for heavy and rare-earth metal separations. In this work, we have benchmarked the accuracy of different quantum chemistry methods for calculating extractant binding energies and selectivities. Specifically, we compare calculated data from different exchange correlation functionals (B3LYP-D3, ωB97X-D3, and M06-L) and different basis sets (including large-core effective core potentials and all-electron basis sets). We report aqueous-phase binding energy and selectivity trends for 1:1 and 3:1 extractant/lanthanide models for the complexes. We find that binding selectivities are not particularly sensitive to model chemistry, but binding energies are sensitive. Furthermore, calculated trends in selectivity using 3:1 extractant/lanthanide models are in better agreement with available experimental trends than trends using 1:1 extractant/lanthanide models. Lastly, we find that the B3LYP-D3/6-31 + G* model chemistry with the Stuttgart large-core relativistic effective core potentials on the lanthanide sufficiently reproduces results from larger basis set calculations and is confirmed as suitable for relatively fast and efficient screening of lanthanide binding energies and selectivities.

36 MATERIALS SCIENCE↗

Solid Phase Extraction of Cadmium and Lead from Water by Amberlyst 15 and Determination by Flame Atomic Absorption Spectrometry

Preconcentration of Cd(II) and Pb(II) was carried out by using column solid phase extraction method. Amberlyst 15 was used as solid phase for these analytes. The optimum extraction conditions such as pH (4), type and volume of eluent (5 mL of 2 mol L{sup −1} HNO{sub 3}) sample flow rate (1 mL min{sup −1}) and sample volume (100 mL for Cd(II) and 750 mL for Pb(II)) were determined. The recoveries were found for Cd(II) and Pb(II) as 104% ± 1% and 102 % ± 2%, respectively. The limit of detections were found as 0.23 µg L{sup −1} for Cd(II) and 0.13 µg L{sup −1} for Pb(II). The effects of foreign ions were also studied. The method was validated by analyzing standard reference material and spiked water samples. Percent relative error and relative standard deviation were below 3% and 4%, respectively.

54 ENVIRONMENTAL SCIENCES↗

Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room

We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 {+-} 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thus required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Biliary Cast Syndrome After Orthotopic Liver Transplantation: Comparison of Mechanical Versus Hydraulic Rheolytic Cast Extraction

Purpose: Biliary cast syndrome (BCS) is the presence of casts within the intrahepatic or extrahepatic biliary system after orthotopic liver transplantation. Our work compares two percutaneous methods for BCS treatment: the mechanical cast-extraction technique (MCE) versus the hydraulic cast-extraction (HCE) technique using a rheolytic system. Materials and Methods: A total of 24 patients were included in the study. Six patients were referred for HCE, and 18 patients were treated with MCE. A statistically significant larger number of sessions was required in the MCE group (21.0, range 11 to 72 sessions) (p = 0.033). Results: Median therapy duration was shorter in the HCE group at 2.4 months (range 2 to 5) compared with 6.7 months (range 3 to 39) in the MCE group (p < 0.001). Both patient acceptance was better and costs for total therapy were 40% less in the HCE group. No significant differences where found concerning clinical and biochemical improvement or graft and patient survival. Conclusion: The use of the hydraulic rheolytic system decreased total therapy time, thereby decreasing the induced inflammation time of the biliary tree. A significant benefit of HCE has been observed in our patients when we compare our results with those of MCE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extraction and Characterization of Nanocrystalline Cellulose from Cassava Bagasse

The objective of this study was to produce highly crystalline nanocellulose from cassava bagasse, which is a by-product from the cassava starch industry that contains 15 to 50 wt% cellulose fibers. For this purpose, the lignocellulosic fiber that was isolated from cassava bagasse was bleached with sodium chlorite and hydrolyzed with sulfuric acid. The obtained suspension was spray-dried and the resulting microparticles were characterized by X-ray diffractometry to determine the crystallinity index. Microcrystalline cellulose was subjected to the same processing conditions and considered as a reference. The crystallinity index of the nanocellulose extracted from the cassava bagasse was higher than the crystallinity index of the nanocellulose extracted from the microcrystalline cellulose; 84.1 and 78.7%, respectively. No other studies have reported cellulose nanocrystals from cassava bagasse with a high crystallinity index. The nanocrystalline cellulose produced in this study is very promising for use in innovative industrial applications.

36 MATERIALS SCIENCE↗

Efficient Acetylation of Xylans by Exploiting the Potassium Acetate Formed During the Alkaline Extraction

Isolation of hemicelluloses through alkaline extraction results in formation of salts, which usually necessitates additional salt removal steps. In this study, acetylation of xylans was studied without the removal of potassium acetate (KAc), a commonly produced salt during the alkaline extraction, to find a facile method to alter the hydrophilic characteristics of hemicelluloses. The acetylation reaction was carried out solely with acetic anhydride without any catalysts or solvents added. The weight gain and ATR–FTIR analyses verified the acetylation of xylans in the presence of KAc. A significant decrease in water solubility and moisture uptake was observed upon acetylation in the presence of KAc which is also accompanied by an increase in thermal stability, disclosing an easy, efficient and environmentally friendly method to obtain hydrophobically modified xylans without the use of toxic catalysts and costly salt purification steps.

36 MATERIALS SCIENCE↗