Search NASA⌕ Search

SEARCH · Search NASA

Results for “FAILURE MODES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Advanced Guidance and Control for Hypersonics and Space Access

Advanced guidance and control (AG&C) technologies are critical for meeting safety, reliability, and cost requirements for the next generation of reusable launch vehicle (RLV), whether it is fully rocket-powered or has air- breathing components. This becomes clear upon examining the number of expendable launch vehicle failures in the recent past where AG&C technologies could have saved a RLV with the same failure mode, the additional vehicle problems where t h i s technology applies, and the costs and time associated with mission design with or without all these failure issues. The state-of-the-art in guidance and control technology, as well as in computing technology, is the point where we can look to the possibility of being able to safely return a RLV in any situation where it can physically be recovered. This paper outlines reasons for AWC, current technology efforts, and the additional work needed for making this goal a reality. There are a number of approaches to AG&C that have the potential for achieving the desired goals. For some of these methods, we compare the results of tests designed to demonstrate the achievement of the goals. Tests up to now have been focused on rocket-powered vehicles; application to hypersonic air-breathers is planned. We list the test cases used to demonstrate that the desired results are achieved, briefly describe an automated test scoring method, and display results of the tests. Some of the technology components have reached the maturity level where they are ready for application to a new vehicle concept, while others are not far along in development.

Hanson, John M.↗

Reliability Effects of Surge Current Testing of Solid Tantalum Capacitors

Solid tantalum capacitors are widely used in space applications to filter low-frequency ripple currents in power supply circuits and stabilize DC voltages in the system. Tantalum capacitors manufactured per military specifications (MIL-PRF-55365) are established reliability components and have less than 0.001% of failures per 1000 hours (the failure rate is less than 10 FIT) for grades D or S, thus positioning these parts among electronic components with the highest reliability characteristics. Still, failures of tantalum capacitors do happen and when it occurs it might have catastrophic consequences for the system. This is due to a short-circuit failure mode, which might be damaging to a power supply, and also to the capability of tantalum capacitors with manganese cathodes to self-ignite when a failure occurs in low-impedance applications. During such a failure, a substantial amount of energy is released by exothermic reaction of the tantalum pellet with oxygen generated by the overheated manganese oxide cathode, resulting not only in destruction of the part, but also in damage of the board and surrounding components. A specific feature of tantalum capacitors, compared to ceramic parts, is a relatively large value of capacitance, which in contemporary low-size chip capacitors reaches dozens and hundreds of microfarads. This might result in so-called surge current or turn-on failures in the parts when the board is first powered up. Such a failure, which is considered as the most prevalent type of failures in tantalum capacitors [I], is due to fast changes of the voltage in the circuit, dV/dt, producing high surge current spikes, I(sub sp) = Cx(dV/dt), when current in the circuit is unrestricted. These spikes can reach hundreds of amperes and cause catastrophic failures in the system. The mechanism of surge current failures has not been understood completely yet, and different hypotheses were discussed in relevant literature. These include a sustained scintillation breakdown model [1-3]; electrical oscillations in circuits with a relatively high inductance [4-6]; local overheating of the cathode [5,7, 8]; mechanical damage to tantalum pentoxide dielectric caused by the impact of MnO2 crystals [2,9, 10]; or stress-induced-generation of electron traps caused by electromagnetic forces developed during current spikes [11]. A commonly accepted explanation of the surge current failures is that at unlimited current supply during surge current conditions, the self-healing mechanism in tantalum capacitors does not work, and what would be a minor scintillation spike if the current were limited, becomes a catastrophic failure of the part [l, 12]. However, our data show that the scintillation breakdown voltages are significantly greater that the surge current breakdown voltages, so it is still not clear why the part, which has no scintillations, would fail at the same voltage during surge current testing (SCT).

Teverovsky, Alexander↗

Effects of AEA Cell-Bypass-Switch Closure on Charged EOS-Aqua NiH2 Cell

The nominal performance of AEA CBPD under simulated EOS-Aqua/Aura flight hardware configuration has been demonstrated. There is no evidence of cell rupture or excessive heat production during or after CBPD switch activation under simulated high cell impedance (open-circuit cell failure mode). Inadvertent CBPD switch activation with a charged cell (low impedance path) intermittently closes and opens up the switch, therefore the device may or may not provide protection against future open-circuit cell failure. Further testing with switches F01 and F02 may provide clarification. The formation of a continuous low impedance path (a homogeneous low melting point alloy), has been confirmed - which is the expected mode of operation.

Keys, Denney↗

Final Technical Report: Supporting Wind Turbine Research and Testing - Gearbox Durability Study

The combination of premature failure of wind turbine gearboxes and the downtime caused by those failures leads to an increase in the cost of electricity produced by the wind. There is a need for guidance to asset managers regarding how to maximize the longevity of their gearboxes in order to help keep the cost of wind energy as low as possible. A low cost of energy supports the US Department of Energy's goal of achieving 20% of the electricity in the United States produced by wind by the year 2030. DNV KEMA has leveraged our unique position in the industry as an independent third party engineering organization to study the problem of gearbox health management and develop guidance to project operators. This report describes the study. The study was conducted in four tasks. In Task 1, data that may be related to gearbox health and are normally available to wind project operators were collected for analysis. Task 2 took a more in-depth look at a small number of gearboxes to gain insight in to relevant failure modes. Task 3 brought together the previous tasks by evaluating the available data in an effort to identify data that could provide early indications of impending gearbox failure. Last, the observations from the work were collected to develop recommendations regarding gearbox health management.

17 WIND ENERGY↗

Stratified processes to analyze SSME parts and subsystems using Weibull methodology

Due to the various parts found in a Space Shuttle Main Engine (SSME), analyzation of every part is not feasible or needed. Based on previous mathematical modeling experience of high velocity cryogenic equipment, the environmental traits of location of the part, temperature range, fluid velocity, pressure range, and elevation variation of fluid flow as being significant factors were determined. Six parts categories were developed. The part categories are: (1) fuel turbomachinery, (2) oxidizer, (3) combustion devices, (4) valves, (5) ducts, and (6) lines. Due to a suspicion that superficial failure modes exist, six status codes were developed. The codes are: (1) part is in service presently, (2) part is out-of-service due to its own failure, (3) part is out-of-service due to engine (or some other part failure), (4) part is out-of-service because it's retired/obsolete (time related), (5) never fired-scrapped due to own problem or part is store, and (6) part is out-of-service for repair. It was suggested that to properly model failure behavior of SSME parts that: (1) significant factors contributing to failure must be examined, (2) relatively precision based on real life data must be examined, and (3) alternative definitions of failure must be initialized by the engineers.

Gray, Lou Allen Bell↗

Reliability of stiffened structural panels: Two examples

The reliability of two graphite-epoxy stiffened panels that contain uncertainties is examined. For one panel, the effect of an overall bow-type initial imperfection is studied. The size of the bow is assumed to be a random variable. The failure mode is buckling. The benefits of quality control are explored by using truncated distributions. For the other panel, the effect of uncertainties in a strain-based failure criterion is studied. The allowable strains are assumed to be random variables. A geometrically nonlinear analysis is used to calculate a detailed strain distribution near an elliptical access hole in a wing panel that was tested to failure. Calculated strains are used to predict failure. Results are compared with the experimental failure load of the panel.

Stroud, W. Jefferson↗

Flaw Tolerance in Lap Shear Brazed Joints

Furnace brazing is a joining process used in the aerospace and other industries to produce strong permanent and hermetic structural joints. As in any joining process, brazed joints have various imperfections and defects. At the present time, our understanding of the influence of the internal defects on the strength of the brazed joints is not adequate. The goal of this 3-part investigation is to better understand the properties and failure mechanisms of the brazed joints containing defects. This study focuses on the behavior of the brazed lap shear joints because of their importance in manufacturing aerospace structures. In Part 1, an average shear strength capability and failure modes of the single lap joints are explored. Stainless steel specimens brazed with pure silver are tested in accordance with the AWS C3.2 standard. Comparison of the failure loads and the ultimate shear strength with the Finite Element Analysis (FEA) of the same specimens as a function of the overlap widths shows excellent correlation between the experimental and calculated values for the defect-free lap joints. A damage zone criterion is shown to work quite well in understanding the failure of the braze joints. In Part 2, the findings of the Part 1 will be verified on the larger test specimens. Also, various flaws will be introduced in the test specimens to simulate lack of braze coverage in the lap joints. Mechanical testing and FEA will be performed on these joints to verify that behavior of the flawed ductile lap joints is similar to joints with a reduced braze area. Finally, in Part 3, the results obtained in Parts 1 and 2 will be applied to the actual brazed structure to evaluate the load-carrying capability of a structural lap joint containing discontinuities. In addition, a simplified engineering procedure will be offered for the laboratory testing of the lap shear specimens.

Flom, Yury↗

Transient Reliability Analysis Capability Developed for CARES/Life

The CARES/Life software developed at the NASA Glenn Research Center provides a general-purpose design tool that predicts the probability of the failure of a ceramic component as a function of its time in service. This award-winning software has been widely used by U.S. industry to establish the reliability and life of a brittle material (e.g., ceramic, intermetallic, and graphite) structures in a wide variety of 21st century applications.Present capabilities of the NASA CARES/Life code include probabilistic life prediction of ceramic components subjected to fast fracture, slow crack growth (stress corrosion), and cyclic fatigue failure modes. Currently, this code can compute the time-dependent reliability of ceramic structures subjected to simple time-dependent loading. For example, in slow crack growth failure conditions CARES/Life can handle sustained and linearly increasing time-dependent loads, whereas in cyclic fatigue applications various types of repetitive constant-amplitude loads can be accounted for. However, in real applications applied loads are rarely that simple but vary with time in more complex ways such as engine startup, shutdown, and dynamic and vibrational loads. In addition, when a given component is subjected to transient environmental and or thermal conditions, the material properties also vary with time. A methodology has now been developed to allow the CARES/Life computer code to perform reliability analysis of ceramic components undergoing transient thermal and mechanical loading. This means that CARES/Life will be able to analyze finite element models of ceramic components that simulate dynamic engine operating conditions. The methodology developed is generalized to account for material property variation (on strength distribution and fatigue) as a function of temperature. This allows CARES/Life to analyze components undergoing rapid temperature change in other words, components undergoing thermal shock. In addition, the capability has been developed to perform reliability analysis for components that undergo proof testing involving transient loads. This methodology was developed for environmentally assisted crack growth (crack growth as a function of time and loading), but it will be extended to account for cyclic fatigue (crack growth as a function of load cycles) as well.

Nemeth, Noel N.↗

Achieving Improved Reliability with Failure Analysis

Reliability is the ability of a product to properly function, within specified performance limits, for a specified period of time, under the life cycle application conditions. Failure analysis is a vital tool in the effort to ensure reliability of electronic products and systems throughout their product lifecycle. Today, organizations involved in activities within the electronics supply chain are facing new challenges, not just from complex assembly styles, harsher lifecycle environments, and sophisticated supply chains, but also from customers who are demanding a quicker turn-around. Unfortunately, root cause failure analysis is often performed incompletely, leading to a poor understanding of failure mechanisms and causes and, customer dissatisfaction due to recurring failures. The PDC (Professional Development Course) starts with an introduction to reliability concepts, physics of failure and an overview of failure mechanisms that affect PCBs (Printed Circuit Boards), PCBAs (Printed Circuit Board Assembly) and components. The PDC then dives into root cause hypothesizing techniques (Pareto, FMEA (Failure Modes and Effects Analysis), fishbone (Cause-And-Effect Diagram), FTA (Fault Tree Analysis)), non-destructive and destructive analysis and, materials characterization will be discussed. Numerous failure analysis case studies will be used to illustrate the techniques and analysis principles to arrive at the root cause(s) of field failures on printed circuit boards, active components, and assemblies. What Attendees will Learn: Topics include: Overview of Reliability Concepts Failure mechanisms of electronic products Root cause analysis Failure analysis techniques -Non-destructive techniques (optical, CSAM (Confocal Scanning Electron Microscopy) etc.) -Destructive analysis (DPA (Destructive Physical Analysis), Decap (Decapsulation), FIB (Focused Ion Beam) etc.) -Materials characterization (XRF (X-Ray Fluorescence) , EDS (Error Detection Sequential), TMA/DSC (Thermal Mechanical Analysis/Differential Scanning Calorimetry) etc.)

PCB quality↗

Scaling of thermal stratification in outlet plena of SFRs with gallium as a surrogate fluid

Due to its high thermal diffusivity, liquid sodium can develop thermally stratified regions in the hot and cold pools of SFRs under certain off normal operating conditions. The temperature gradients in the fluid give rise to mixed convection flow in which flow velocities result both from pressure gradients and from volume forces induced by density gradients. High thermal diffusivity and low momentum diffusivity leads to reduced thermal mixing and enhanced stratification. Thermal stratification, if not looked carefully in the design, can lead to severe consequences in normal operation with forced coolant circulation and during off-normal natural circulation. The resulting hydraulic and thermal loads can cause the failure modes in structures and components critical for reactor safety. Thermal stratification in the SFR pools can lead to thermal fatigue, which can lead to structural and material failure, or pose serious concerns for the reactor safety. In addition to thermo-structural issues, the reactivity changes are significantly impacted due to density or temperature driven movement of liquid sodium. Temperature changes or gradients in the Upper Instrumentation Structures (UIS) of SFRs can lead to thermal contraction, a case that can lead to positive reactivity insertion after core shut-down. The motivation of this work is to design a scaled down experimental facility which can generate high fidelity data for thermal stratification physics to validate 3-dimensional (3D) Computational Fluid Dynamics (CFD) models. These validated CFD codes can be used to improve the 1-dimensional (1D) system level codes such as SAS4A/SASSYS-1 which are currently not capable of simulating thermal stratification accurately. These improvements in 1D system level SAS4A/SASSYS-1 codes can significantly improve the safety analyses and design of SFRs. The GaTE facility outlet plenum model is designed based on physics based similarities. Thermal stratification physics is governed primarily by the Richardson numbers (Ri). The expected low flow rates during off-normal conditions can lead to a high degree of thermal stratification in the outlet plenum with a corresponding Ri = 530. Therefore, the inlet flow velocities and inlet hydraulic diameter for the gallium coolant entering the test vessel are required to achieve same Ri. The design of test vessel in GaTE facility is finalized to a 1/20. scale outlet plenum height of the ABTR. This design of the test facility will allow the decoupling of the thermal stratification physics at low flow rates with the transient natural circulation. In other words, it will enable effective control to study thermal stratification at very low flow rates. Numerical studies are conducted with a 3D CFD code to examine the thermal behavior of the selected test design. Simulation results show that thermal gradients are present only in the vertical or axial direction which are similar to the behavior reported in previous studies on full scale SFR models. Future work will involve the experimental studies using the GaTE facility with the high fidelity instrumentation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Delamination crack growth in unidirectional fiber-reinforced composites under static and cyclic loading

An investigation of delamination crack growth in a unidirectional composite laminate under static and fatigue loading conditions is presented. An experimental program was conducted to study failure mechanisms and characterize the crack growth rate; analytical modeling based on microscopic observations was carried out using an advanced singular finite element method of the hybrid-stress model. Using a mixed-mode failure criterion, the delamination growth under a monotonically increasing load can be predicted; the rate of delamination crack propagation under fatigue loading is directly related to the amplitudes of cyclic opening and shearing mode stress intensity factors by a power law relationship.

Wang, S. S.↗

Characterization of Static Performance and Failure of Resistance Spot Welds of High-Strength and Press-Hardened Steels

The static performances and failure characteristics of resistance spot welds (RSW) of steel sheets were studied in this work. Both similar and dissimilar joints of press-hardened steel grade 22MnB5 and as-rolled high-strength steel grade 1000 were examined. From metallographic analyses and micro-hardness measurements, it was shown that the microstructures of base metal (BM), heat affected zone (HAZ) and fusion zone of steel joints were noticeably different. In particular, the HAZ close to BM or subcritical HAZ (SCHAZ) of 22MnB5 steel exhibited greatly decreased hardness due to occurring tempered martensite, in which carbide precipitation was clearly observed. Furthermore, tensile shear test and cross-tension test of the welded steel sheets were carried out. The determined maximum loads, energy absorbability and corresponding failure mechanisms were analyzed and compared. The RSW samples of similar steel grade 1000 provided the highest load-carrying capacity and absorbed energy in both tests. Due to the large hardness difference and soft zone in weldment of dissimilar steel specimen, failure loads and static absorbed energies were deteriorated up to 17 and 68%, respectively. The observed fracture occurrences of all investigated joints were pullout failure mode, in which BM and HAZ were the crack initiation sites of grades 1000 steel and 22MnB5 steel, respectively. The SCHAZ of welded boron steel considerably caused the failure onset in tension shear test, but seemed to have negligible effect on cross-tension test.

36 MATERIALS SCIENCE↗

Computational Simulation of Damage Progression of Composite Thin Shells Subjected to Mechanical Loads

Defect-free and defected composite thin shells with ply orientation (90/0/+/-75) made of graphite/epoxy are simulated for damage progression and fracture due to internal pressure and axial loading. The thin shells have a cylindrical geometry with one end fixed and the other free. The applied load consists of an internal pressure in conjunction with an axial load at the free end, the cure temperature was 177 C (350 F) and the operational temperature was 21 C (70 F). The residual stresses due to the processing are taken into account. Shells with defect and without defects were examined by using CODSTRAN an integrated computer code that couples composite mechanics, finite element and account for all possible failure modes inherent in composites. CODSTRAN traces damage initiation, growth, accumulation, damage propagation and the final fracture of the structure. The results show that damage initiation started with matrix failure while damage/fracture progression occurred due to additional matrix failure and fiber fracture. The burst pressure of the (90/0/+/- 75) defected shell was 0.092% of that of the free defect. Finally the results of the damage progression of the (90/0/+/- 75), defective composite shell was compared with the (90/0/+/- theta, where theta = 45 and 60, layup configurations. It was shown that the examined laminate (90/0/+/- 75) has the least damage tolerant of the two compared defective shells with the (90/0/+/- theta), theta = 45 and 60 laminates.

Gotsis, P. K.↗

Ares-I-X Vehicle Preliminary Range Safety Malfunction Turn Analysis

Ares-I-X is the designation given to the flight test version of the Ares-I rocket (also known as the Crew Launch Vehicle - CLV) being developed by NASA. As part of the preliminary flight plan approval process for the test vehicle, a range safety malfunction turn analysis was performed to support the launch area risk assessment and vehicle destruct criteria development processes. Several vehicle failure scenarios were identified which could cause the vehicle trajectory to deviate from its normal flight path, and the effects of these failures were evaluated with an Ares-I-X 6 degrees-of-freedom (6-DOF) digital simulation, using the Program to Optimize Simulated Trajectories Version 2 (POST2) simulation framework. The Ares-I-X simulation analysis provides output files containing vehicle state information, which are used by other risk assessment and vehicle debris trajectory simulation tools to determine the risk to personnel and facilities in the vicinity of the launch area at Kennedy Space Center (KSC), and to develop the vehicle destruct criteria used by the flight test range safety officer. The simulation analysis approach used for this study is described, including descriptions of the failure modes which were considered and the underlying assumptions and ground rules of the study, and preliminary results are presented, determined by analysis of the trajectory deviation of the failure cases, compared with the expected vehicle trajectory.

Beaty, James R.↗

Power Distribution for Cryogenic Instruments at 6-40K The James Webb Space Telescope Case

The Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST) operates its instruments passively cooled at around 40 Kelvin (K), with a warm Instrument Electronic Compartment (IEC) at 300K attached to it. From the warm electronics all secondary signal and power harnesses have to bridge this 300-40K temperature difference and minimize the power dissipation and parasitic heat leak into the cold region. After an introduction of the ISIM with its instruments, the IEC with the electronics, and the harness architecture with a special radiator, this paper elaborates on the cryogenic wire selection and tests performed to establish current de-rating rules for different wire types. Finally failure modes are analyzed for critical instrument interfaces that could inject excessive currents and heat into the harness and cold side, and several solutions for the removal of such failures are presented.

Rumler, Peter↗

Evaluation of Low-cost, Full HD, CMOS Cameras for Use in the Calcine Retrieval Project - 19530

This paper describes results from radiation testing conducted on low-cost, commercial off-the-shelf, full high-definition (HD) resolution (1920 x 1080 p), complementary metal-oxide-semiconductor (CMOS) camera sensors. The purpose of the testing was to evaluate the sensors' suitability for use in the Calcine Retrieval Project by determining their image quality and life expectancy while operating in an ionizing radiation field of 20.0 Gy/h. The two camera sensors tested were the Axis FA1105 and Axis FA1125. These commercial camera sensors were designed for retail security surveillance and have no radiation-hardened (rad-hard) components. In addition to radiation testing, the sensors' field-of-view, resolution, and low-light image quality were tested at several target distances to ensure they meet project requirements. Testing was divided into two phases. During Phase 1, four FA1105 sensors and four FA1125 sensors were tested simultaneously without any shielding in radiation fields of 25.5 Gy/h and 49.3 Gy/h. In Phase 2, three FA1105 and five FA1125 sensors were shielded by 22.2 mm of lead and tested simultaneously in radiation fields of 26.8 Gy/h, 52.3 Gy/h, 143.0 Gy/h, 200.7 Gy/h, 404.6 Gy/h, and 2,317.5 Gy/h. Dose rate values were established using film dosimetry readings. Apertures in the shielding allowed for a 40-degree field of view while shielding all parts of the sensor except for directly in front of the CMOS sensor array. All testing was conducted at the Idaho Accelerator Center in Pocatello, Idaho, using a 450 keV X-ray generator. Sensor images were automatically captured at regular intervals throughout the testing for qualitative evaluation by the test team. Film dosimetry was placed near the sensors to record actual dose totals. The 450 keV setting generates X-ray radiation with an energy level close to the primary gamma energy level produced by the Cesium-137 isotope in the calcine, which is 662 keV. Results from Phase 1 indicate the sensors failed at an average cumulative dose of 226.3 Gy. For a given 20.0 Gy/h field this results in a mean time to failure (MTTF) of 11.3 hours. Recorded images from all sensors showed minimal image degradation due to radiation-induced noise. When the sensors finally failed, the failure mode was an abrupt loss of video. The image went black suggesting some other component in the sensor head besides the CMOS sensor array was responsible for the failure. During a portion of Phase 1 testing, a commercial, rad-hard camera was irradiated in the 25.5 Gy/h field along with the eight Axis FA series sensors. Image quality from the FA series sensors significantly outperformed the image quality of the rad-hard camera in radiation-induced noise tolerance, image resolution, and dynamic range. During Phase 2 testing, all sensors produced excellent images in radiation fields as high as 404.6 Gy/h. One FA1125 sensor was tested at the highest dose rate of 2,317.5 Gy/h. At this dose rate, the image was color shifted towards red and contained a significant amount radiation-induced noise. The sensor did not fail and was producing usable imagery after one hour, at which time the test was ended due to allotted beam-time at the test facility. Eighteen hours after X-rays were shut off, the sensor image returned to normal color and all eight sensors continued to operate without any visible, permanent image degradation. For Phase 2 testing, it was not possible to establish a MTTF since none of the shielded sensors failed during the allotted test time. However, given the highest cumulative dose of 4,142.1 Gy received by a shielded FA1125 sensor, a minimum life expectancy of 207 hours (8.6 days) is predicted while operating in a 20.0 Gy/h field. Test results indicate the radiation tolerance of the FA series sensor's CMOS array, along with the small form factor, full HD image quality, wide dynamic range, and Ethernet standard makes it suitable for short-term use in monitoring and visually documenting waste remediation efforts for the Calcine Retrieval Project at the INL. The sensor's low-cost of about $140 US, compared to commercial rad-hard cameras costing between $5,000 and $7,000 US each, allow them to be used as an affordable, disposable resource for many short-duration, radioactive waste remediation efforts where decontamination of an expensive, commercial rad-hard camera is undesirable or not possible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal barrier coating life prediction model development

This report describes work performed to determine the predominat modes of degradation of a plasma sprayed thermal barrier coating system and to develop and verify life prediction models accounting for these degradation modes. The primary TBC system consisted of a low pressure plasma sprayed NiCrAlY bond coat, an air plasma sprayed ZrO2-Y2O3 top coat, and a Rene' 80 substrate. The work was divided into 3 technical tasks. The primary failure mode to be addressed was loss of the zirconia layer through spalling. Experiments showed that oxidation of the bond coat is a significant contributor to coating failure. It was evident from the test results that the species of oxide scale initially formed on the bond coat plays a role in coating degradation and failure. It was also shown that elevated temperature creep of the bond coat plays a role in coating failure. An empirical model was developed for predicting the test life of specimens with selected coating, specimen, and test condition variations. In the second task, a coating life prediction model was developed based on the data from Task 1 experiments, results from thermomechanical experiments performed as part of Task 2, and finite element analyses of the TBC system during thermal cycles. The third and final task attempted to verify the validity of the model developed in Task 2. This was done by using the model to predict the test lives of several coating variations and specimen geometries, then comparing these predicted lives to experimentally determined test lives. It was found that the model correctly predicts trends, but that additional refinement is needed to accurately predict coating life.

Hillery, R. V.↗

Final Scientific/Technical Report (DOE F 241.3) Next-Generation LED Package Architectures Enabled by Thermally Conductive Transparent Encapsulants

The objective of this program is to generate novel LED package designs that would provide 30% improvement in lumen/$ output. This was to be achieved by improving thermal management in encapsulants/ phosphors to reduce their temperatures. Currently, the heat that is generated during down conversion of blue light to longer wavelengths by the phosphors dispersed in the encapsulant does not have optimum thermal pathways for dissipation due to poor thermal conductivity of the encapsulant material. Additionally, high temperature in the encapsulant during operation is one of the primary failure modes in LED luminaires resulting in much shorter than expected life. The thermal issues manifest in color instability (yellowing, browning), cracking and hot spots in the encapsulant leading to failures. This work explored boron nitride (hBN) as thermal fillers in encapsulants to improve thermal conductivity while minimally impacting optical properties. Various approaches to Boron Nitride (BN) were evaluated and over 380 samples were generated to down select appropriate BN morphologies. We developed a range or BN materials for enabling thermal properties while attempting to minimally impact to optical properties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗