Search NASA⌕ Search

SEARCH · Search NASA

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

High Strain-Rate and Temperature Effects on the Response of Composites

The objective of the research is to expand the experimental study of the effect of strain rate on mechanical response (deformation and failure) of epoxy resins and carbon fibers/epoxy matrix composites, to include elevated temperature tests. The experimental data provide the information needed for NASA scientists for the development of a nonlinear, strain rate and temperature dependent deformation and strength models for composites that can subsequently be used in design. This year effort was directed into the development and testing of the epoxy resin at elevated temperatures. Two types of epoxy resins were tested in shear at high strain rates of about 700 per second and elevated temperatures of 50 and 80 C. The results show that the temperature significantly affects the response of epoxy.

Gilat, Amos↗

Time-temperature-stress superposition of PBX 9502 compressive creep data for lifetime predictions

The plastic-bonded explosive (PBX) 9502 is a viscoelastic, high-solids loaded polymer bound composite comprised of 95 weight% (wt%) TATB explosive crystals and 5 wt% FK-800 polymer binder. The uniaxial quasi-static mechanical properties have been studied and characterized extensively over 25+ years, including creep. Creep is the strain evolution over time as a result of an asymmetric load typically at temperatures above ambient. Creep measurements to failure can take excessively long periods of time depending on various factors including applied stress, temperature, and loading rate that render a single test to failure impossible. Using the principles of time-temperature-stress superposition (TTSSP), short-term creep tests at various applied stresses and temperatures can be used for long-term creep predictions. The TTSSP model shifts short-term test data using two factors, one for temperature and stress, creating a master curve at a reference test condition. The master curve can be shifted to predict the creep response at any desired test condition. PBX 9502 compression specimens were tested at three temperatures and various applied stresses. This work discusses the TTSSP analysis of PBX 9502 compressive creep data to create a single comprehensive master curve.

36 MATERIALS SCIENCE↗

Time-Temperature-Stress Superposition of PBX 9502 Compressive Creep Data for Lifetime Predictions

The plastic-bonded explosive (PBX) 9502 is a viscoelastic, high-solids loaded polymer bound composite comprised of 95 weight% (wt%) TATB explosive crystals and 5 wt% FK-800 polymer binder. The uniaxial quasi-static mechanical properties have been studied and characterized extensively over 25+ years, including creep. Creep is the strain evolution over time as a result of an asymmetric load typically at temperatures above ambient. Creep measurements to failure can take excessively long periods of time depending on various factors including applied stress, temperature, and loading rate that render a single test to failure impossible. Using the principles of time-temperature-stress superposition (TTSSP), short-term creep tests at various applied stresses and temperatures can be used for long-term creep predictions. The TTSSP model shifts short-term test data using two factors, one for temperature and stress, creating a master curve at a reference test condition. The master curve can be shifted to predict the creep response at any desired test condition. PBX 9502 compression specimens were tested at three temperatures and various applied stresses. This work discusses the TTSSP analysis of PBX 9502 compressive creep data to create a single comprehensive master curve.

36 MATERIALS SCIENCE↗

Whole-Field Simultaneous Integrated-Boost Intensity-Modulated Radiotherapy for Patients With Nasopharyngeal Carcinoma

Purpose: To retrospectively review the outcomes of our patients with newly diagnosed nondisseminated nasopharyngeal carcinoma treated with intensity-modulated radiotherapy using a whole-field simultaneous integrated-boost technique. Methods and Materials: A total of 175 patients treated with WF-SIB between mid-2004 and 2005 were eligible for study inclusion. The distribution of disease by stage was Stage IA in 10.9%, Stage IIA in 2.3%, Stage IIB in 21.7%, Stage III in 41.1%, Stage IVA in 14.9%, and Stage IVB in 9.1%. Of the 175 patients, 2 (1.2%), 10 (5.7%), and 163 (93.1%) had World Health Organization type I, II, and III histologic features, respectively. We prescribed 70 Gy, 60 Gy, and 54 Gy delivered in 33 fractions within 6.5 weeks at the periphery of three planning target volumes (PTV; PTV70, PTV60, and PTV54, respectively). Of the 175 patients, 46 with early T-stage disease received a brachytherapy boost, and 127 with advanced local or regional disease received chemotherapy. Results: The median follow-up period was 34 months. The overall 3-year local failure-free survival, regional failure-free survival, distant failure-free survival, and overall survival rate was 93.6%, 93.3%, 86.6%, and 87.2%, respectively. Cox regression analysis showed Stage N2-N3 disease (p = .029) and PTV (p = .024) to be independent factors predicting a greater risk of distant failure and poor overall survival, respectively. Grade 3 acute mucositis/pharyngitis occurred in 23.4% of patients, and Stage T4 disease was the only significant predictor of mucositis/pharyngitis (p = .021). Conclusion: Whole-field simultaneous integrated-boost intensity-modulated radiotherapy with a dose >70 Gy achieved excellent locoregional control, without an excess incidence of severe, acute mucositis/pharyngitis, in the present study. Strategies for using such highly conformal treatment for patients with a large tumor and late N-stage disease are potential areas of investigation for future studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Demisability of GFRP and CFRP Components of Reentering Orbital Debris: Phase I Test Results

Observations of surviving reentry debris on the ground and research performed by Hyperschall Technologie Göttingen (HTG) [1] indicated that significantly more glass fiber-reinforced polymer (GFRP) and carbon fiber-reinforced polymer (CFRP) components survive reentry than current models predict. NASA’s Orbital Debris Program Office conducted a series of tests to evaluate the accuracy of material demise models for reentering orbital debris used in NASA’s Object Reentry Survival Analysis Tool (ORSAT) and Debris Assessment Software (DAS). Testing is planned in a multi-phase series to allow for quick quantification of results as well as refinement of methods resulting from lessons learned during early phases. The Phase 1 tests discussed here validated ORSAT models for homogeneous metals, provided an efficient quantification of composite material demisability properties like mass loss rate and overall time to demise, and identified potential failure modes, which are currently not well understood. Phase 2 tests will be used to further understand mass loss rates and modes of both thermal and mechanical failure in composite materials. The authors exposed 95 samples of aluminum, CFRP, Kevlar fiber-reinforced polymer, GFRP, and sheets of G10 fiberglass to conditions approximating the reentry environment using an inductively coupled plasma (ICP) torch facility. The cylindrical CFRP samples were exposed to the atmospheric pressure plasma, at both the end and the midpoint, to investigate the difference in demisability between parts with exposed edges, like panels, and parts with no edges, such as carbonoverwrapped pressure vessels (COPVs). In a non-oxidative environment, no composite materials demised within the 5-minute test time. In the oxidative, elevated heat flux environment, CFRP samples demised between 210 s and 270 s. For the first 100 s of insertion time, most of the mass loss was due to pyrolysis of resin, creating an approximately bi-linear mass-loss rate curve with time. In a non-oxidative environment, carbon filaments were observed to unravel from some of the CFRP end-burned samples; however, this effect did not seem to affect the overall time to demise for the samples significantly. These results indicate that both GFRP and CFRP components survive reentry with significantly more remaining mass than current models predict.

Greene, Benton R.↗

Delamination crack growth in unidirectional fiber-reinforced composites under static and cyclic loading

An investigation of delamination crack growth in a unidirectional composite laminate under static and fatigue loading conditions is presented. An experimental program was conducted to study failure mechanisms and characterize the crack growth rate; analytical modeling based on microscopic observations was carried out using an advanced singular finite element method of the hybrid-stress model. Using a mixed-mode failure criterion, the delamination growth under a monotonically increasing load can be predicted; the rate of delamination crack propagation under fatigue loading is directly related to the amplitudes of cyclic opening and shearing mode stress intensity factors by a power law relationship.

Wang, S. S.↗

Fatigue mechanics - An assessment of a unified approach to life prediction

Consideration is given to the development of a total-life prediction methodology for aerospace structures based solely on crack propagation from a microstructural defect at stress concentrations. Crack-growth lives were calculated for a given loading condition by integrating the crack-growth-rate-against-delta K relationships for crack growth from a microstructural defect size to failure. Both small- and large-crack growth rate data were used. The assessment was based on data on 2024-T3 aluminum alloy, 2090-T8E41 aluminum-lithium alloy, annealed Ti-6Al-4V titanium alloy, and high-strength 4340 steel under either constant-amplitude or spectrum loading. Good agreement was found between fatigue lives measured on notched specimens with those computed from the total-life analysis.

Newman, J. C., Jr.↗

Lifetime Predictions of a Titanium Silicate Glass with Machined Flaws

A dynamic fatigue study was performed on a Titanium Silicate glass to assess its susceptibility to delayed failure and to compare the results with those of a previous study. Fracture mechanics techniques were used to analyze the results for the purpose of making lifetime predictions. The material strength and lifetime was seen to increase due to the removal of residual stress through grinding and polishing. Influence on time-to-failure is addressed for the case with and without residual stress present. Titanium silicate glass otherwise known as ultra-low expansion (ULE)* glass is a candidate for use in applications requiring low thermal expansion characteristics such as telescope mirrors. The Hubble Space Telescope s primary mirror was manufactured from ULE glass. ULE contains 7.5% titanium dioxide which in combination with silica results in a homogenous glass with a linear expansion coefficient near zero. delayed failure . This previous study was based on a 230/270 grit surface. The grinding and polishing process reduces the surface flaw size and subsurface damage, and relieves residual stress by removing the material with successively smaller grinding media. This results in an increase in strength of the optic during the grinding and polishing sequence. Thus, a second study was undertaken using samples with a surface finish typically achieved for mirror elements, to observe the effects of surface finishing on the time-to-failure predictions. An allowable stress can be calculated for this material based upon modulus of rupture data; however, this does not take into account the problem of delayed failure, most likely due to stress corrosion, which can significantly shorten lifetime. Fortunately, a theory based on fracture mechanics has been developed enabling lifetime predictions to be made for brittle materials susceptible to delayed failure. Knowledge of the factors governing the rate of subcritical flaw growth in a given environment enables the development of relations between lifetime, applied stress and failure probability for the material under study. Dynamic fatigue is one method of obtaining the necessary information to develop these relationships. In this study, the dynamic fatigue method was used to construct a time-to-failure diagram for polished ULE glass.

Tucker, Dennis S.↗

Characterization of laboratory-scale hydraulic fracturing for EGS

To investigate the impact of reservoir stimulation by hydraulic fracturing, a series of advanced lab-scale block tests were conducted with multiple measurement methods to characterize the fracture and to assess the operation and the performance of an enhanced or engineered geothermal system (EGS). The stimulation test samples were 330-mm cubic blocks of Sierra White granite with one injection well and four producers drilled into it. Acoustic emissions generated during the fracture initiation and propagation were monitored with twenty AE sensors mounted on all sides of the block to help characterize the fracture initiation and propagation process. The recorded AE signals were analyzed to obtain the event location and the failure mechanism. The localized AE events shows that due to the low viscosity of the fracturing fluid (water), the fracture propagated rapidly and took only about 1.4 s to reach near the block surface. During the fracturing phase, about 47 percent of the events were determined to be shear/mixed mode failure events, 28 percent tensile failure events, and 25 percent compressional failure events. Just after the simulation, a step-rate (constant flowrate) injection test was carried out to investigate the reservoir injectivity enhancement. During this phase additional compressional failure events were observed and the percentages of tensile failure and shear/mixed mode failure decreased. The dramatic increase of the injection rate with small increments of the injection pressure demonstrates the nonlinear response of the fracture to effective normal stress variation with much higher fracture opening increase during the low effective normal stress interval. Hydraulic fracturing tests under different stress levels show that more AE hits/events are recorded when the rock block is under higher applied stress. The reconstructed 3D fracture geometry shows good agreement with the AE monitoring results. After fracturing, a tracer test was carried out and the fracture aperture was estimated to be around 139 μm. The tracer recovery curve shows two linear portions of the tracer tail on a semi-log plot similar to that observed in some field data and predicted by numerical modeling. Laser scanning of the fracture surfaces indicates that the induced fracture has a rough surface with a joint roughness coefficient (JRC) of 12.98 and tortuosity of 1.10, both of which are slightly larger than that from the Brazilian test fracture on the same rock. The thin section and SEM observations show that the fracture follows the weak boundaries between the Quartz and Albite grains or the weak beddings in the grains.

58 GEOSCIENCES↗

Scintillation Breakdowns in Chip Tantalum Capacitors

Scintillations in solid tantalum capacitors are momentarily local breakdowns terminated by a self-healing or conversion to a high-resistive state of the manganese oxide cathode. This conversion effectively caps the defective area of the tantalum pentoxide dielectric and prevents short-circuit failures. Typically, this type of breakdown has no immediate catastrophic consequences and is often considered as nuisance rather than a failure. Scintillation breakdowns likely do not affect failures of parts under surge current conditions, and so-called "proofing" of tantalum chip capacitors, which is a controllable exposure of the part after soldering to voltages slightly higher than the operating voltage to verify that possible scintillations are self-healed, has been shown to improve the quality of the parts. However, no in-depth studies of the effect of scintillations on reliability of tantalum capacitors have been performed so far. KEMET is using scintillation breakdown testing as a tool for assessing process improvements and to compare quality of different manufacturing lots. Nevertheless, the relationship between failures and scintillation breakdowns is not clear, and this test is not considered as suitable for lot acceptance testing. In this work, scintillation breakdowns in different military-graded and commercial tantalum capacitors were characterized and related to the rated voltages and to life test failures. A model for assessment of times to failure, based on distributions of breakdown voltages, and accelerating factors of life testing are discussed.

Teverovsky, Alexander↗

Failure analysis and modeling of a multicomputer system

This thesis describes the results of an extensive measurement-based analysis of real error data collected from a 7-machine DEC VaxCluster multicomputer system. In addition to evaluating basic system error and failure characteristics, we develop reward models to analyze the impact of failures and errors on the system. The results show that, although 98 percent of errors in the shared resources recover, they result in 48 percent of all system failures. The analysis of rewards shows that the expected reward rate for the VaxCluster decreases to 0.5 in 100 days for a 3 out of 7 model, which is well over a 100 times that for a 7-out-of-7 model. A comparison of the reward rates for a range of k-out-of-n models indicates that the maximum increase in reward rate (0.25) occurs in going from the 6-out-of-7 model to the 5-out-of-7 model. The analysis also shows that software errors have the lowest reward (0.2 vs. 0.91 for network errors). The large loss in reward rate for software errors is due to the fact that a large proportion (94 percent) of software errors lead to failure. In comparison, the high reward rate for network errors is due to fast recovery from a majority of these errors (median recovery duration is 0 seconds).

Subramani, Sujatha Srinivasan↗

Study of High Strain Rate Response of Composites

The objective of the research was to continue the experimental study of the effect of strain rate on mechanical response (deformation and failure) of epoxy resins and carbon fibers/epoxy matrix composites, and to initiate a study of the effects of temperature by developing an elevated temperature test. The experimental data provide the information needed for NASA scientists for the development of a nonlinear, rate dependent deformation and strength models for composites that can subsequently be used in design. This year effort was directed into testing the epoxy resin. Three types of epoxy resins were tested in tension and shear at various strain rates that ranges from 5 x 10(exp -5), to 1000 per second. Pilot shear experiments were done at high strain rate and an elevated temperature of 80 C. The results show that all, the strain rate, the mode of loading, and temperature significantly affect the response of epoxy.

Gilat, Amos↗

Long-Term Results of Brachytherapy for Carcinoma of the Penis Confined to the Glans (N- or NX)

Purpose: To analyze the results of exclusive interstitial low-dose-rate brachytherapy (BT) for squamous cell carcinoma (SCC) of the penis, strictly confined to the glans. Methods and Materials: A total of 144 patients with SSC of the glans penis were treated with BT. Inguinal nodal dissection was performed in 19% of patients (all N-). After circumcision, BT was performed using the hypodermic needle technique. Median iridium length per patients was 24 cm (range, 4-108) and median dose was 65 Gy (range, 37-75). Median treated volume was 22 cm{sup 3} (range, 5-110) and median reference isodose rate was 0.4 Gy/h (range, 0.2-1.2). Results: Median follow-up was 5.7 years (range, 0.5-29). The 10-year penile recurrence, inguinal lymph node recurrence, and inguinal nodal metastasis rates were: 20% (CI 95%, 11-29), 11% (CI 95%, 5-17), and 6% (CI 95%, 2-10), respectively. After salvage treatment, 86% patients with local failure were in a complete remission at last follow-up. The 10-year probability of avoiding penile surgery (for complication or local recurrence) was 72% (CI 95%, 62-82). The 10-year cancer-specific survival rate was 92% (CI 95%, 87-97). Diameter of tumor significantly increased the risk of recurrence (p = 0.02). The 10-year painful ulceration and stenosis risk rates were: 26% (CI 95%, 17-35) and 29% (CI 95%, 18-40), respectively. Seven patients required excision for necrosis. Treated volume and reference isodose rate significantly increased the risk of complications. Conclusion: BT is an effective conservative treatment for SCC confined to the glans. Salvage local treatment is effective. Dose rate should be limited to decrease toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distant Metastasis Risk Stratification for Patients Undergoing Curative Resection Followed by Adjuvant Chemoradiation for Extrahepatic Bile Duct Cancer

Purpose: To analyze the prognostic factors predicting distant metastasis in patients undergoing adjuvant chemoradiation for extrahepatic bile duct (EHBD) cancer. Methods and Materials: Between January 1995 and August 2006, 166 patients with EHBD cancer underwent resection with curative intent, followed by adjuvant chemoradiation. There were 120 males and 46 females, and median age was 61 years (range, 34-86). Postoperative radiotherapy was delivered to tumor bed and regional lymph nodes (median dose, 40 Gy; range, 34-56 Gy). A total of 157 patients also received fluoropyrimidine chemotherapy as a radiosensitizer, and fluoropyrimidine-based maintenance chemotherapy was administered to 127 patients. Median follow-up duration was 29 months. Results: The treatment failed for 97 patients, and the major pattern of failure was distant metastasis (76 patients, 78.4%). The 5-year distant metastasis-free survival rate was 49.4%. The most common site of distant failure was the liver (n = 36). On multivariate analysis, hilar tumor, tumor size {>=}2 cm, involved lymph node, and poorly differentiated tumor were associated with inferior distant metastasis-free survival (p = 0.0348, 0.0754, 0.0009, and 0.0078, respectively), whereas T stage was not (p = 0.8081). When patients were divided into four groups based on these risk factors, the 5-year distant metastasis-free survival rates for patients with 0, 1, 2, and 3 risk factors were 86.4%, 59.9%, 32.5%, and 0%, respectively (p < 0.0001). Conclusion: Despite maintenance chemotherapy, distant metastasis was the major pattern of failure in patients undergoing adjuvant chemoradiation for EHBD cancer after resection with curative intent. Intensified chemotherapy is warranted to improve the treatment outcome, especially in those with multiple risk factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Study of Longitudinal Control Problems at Low and Negative Damping and Stability with Emphasis on Effects of Motion Cues

As part of a general investigation to determine the effects of simulator motions on pilot opinion and task performance over a wide range of vehicle longitudinal dynamics, a cooperative NASA-AMAL program was conducted on the centrifuge at Johnsville, Pennsylvania. The test parameters and measurements for this program duplicated those of earlier studies made at Ames Research Center with a variable-stability airplane and with a pitch-roll chair flight simulator. Particular emphasis was placed on the minimum basic damping and stability the pilots would accept and on the minimum dynamics they considered controllable in the event of stability-augmentation system failure. Results of the centrifuge-simulator program indicated that small positive damping was required by the pilots over most of the frequency range covered for configurations rated acceptable for emergency conditions only (e.g., failure of a pitch damper). It was shown that the pilot's tolerance for unstable dynamics was dependent primarily on the value of damping. For configurations rated acceptable for emergency operation only, the allowable instability and damping corresponded to a divergence time to double amplitude of about 1 second. Comparisons were made of centrifuge, pitch-chair and fixed-cockpit simulator tests with flight tests. Pilot ratings indicated that the effects of incomplete or spurious motion cues provided by these three modes of simulation were important only for high-frequency, lightly damped dynamics or unstable, moderately damped dynamics. The pitch- chair simulation, which provided accurate angular-acceleration cues to the pilot, compared most favorably with flight. For the centrifuge simulation, which furnished accurate normal accelerations but spurious pitching and longitudinal accelerations, there was a deterioration of pilots' opinion relative to flight results. Results of simulator studies with an analog pilot replacing the human pilot illustrated the adaptive capability of human pilots in coping with the wide range of vehicle dynamics and the control problems covered in this study. It was shown that pilot-response characteristics, deduced by the analog-pilot method, could be related to pilot opinion. Possible application of these results for predicting flight-control problems was illustrated by means of an example control-problem analysis. The results of a brief evaluation of a pencil-type side-arm controller in the centrifuge showed a considerable improvement in the pilots' ability to cope with high-frequency, low-damping dynamics, compared to results obtained with the center stick. This improvement with the pencil controller was attributed primarily to a marked reduction in the adverse effects of large and exaggerated pitching and longitudinal accelerations on pilot control precision.

Sadoff, Melvin↗

Integrity in flight control systems

In connection with advances in technology, mainly in the electronic area, aircraft flight control applications have evolved from simple pilot-relief autopilots to flight-critical and redundant fly-by-wire and active control systems. For flight-critical implementations which required accommodation of inflight failures, additional levels of redundancy were incorporated to provide fail-safe and fail-operative performance. The current status of flight control systems reliability is examined and high-reliability approaches are discussed. Attention is given to the design of ring laser gyros and magnetohydrodynamic rate sensors, redundancy configurations for component failure protection, improvements of hydraulic actuators made on the component level, integrated actuators, problems of software reliability, lightning considerations, and failure detection methods for component and system failures.

Kurzhals, P. R.↗

PSA Nadir of <0.5 ng/mL Following Brachytherapy for Early-Stage Prostate Adenocarcinoma is Associated With Freedom From Prostate-Specific Antigen Failure

Purpose: Because limited information exists regarding whether the rate or magnitude of PSA decline following brachytherapy predicts long-term clinical outcomes, we evaluated whether achieving a prostate-specific antigen (PSA) nadir (nPSA) <0.5 ng/mL following brachytherapy is associated with decreased PSA failure and/or distant metastasis. Methods and Materials: We retrospectively analyzed our database of early-stage prostate adenocarcinoma patients who underwent brachytherapy, excluding those receiving androgen-deprivation therapy and those with <2 years follow-up. Median and mean pretreatment PSA were 6 ng/mL and 7.16 ng/mL, respectively. By clinical stage, 775 were low risk ({<=}T2a), 126 were intermediate risk (T2b), and 20 were high risk (>T2b). By Gleason score, 840 were low risk ({<=}6), 71 were intermediate risk (7), and 10 were high risk (>7). Patients were treated with brachytherapy only (I-125, n = 779, or Pd-103, n = 47), or brachytherapy + external-beam radiation therapy (n = 95). Median follow-up was 6.3 years. We noted whether nPSA <0.5 ng/mL was achieved and the time to achieve this nadir and tested for associations with pretreatment risk factors. We also determined whether this PSA endpoint was associated with decreased PSA failure or distant metastasis. Results: Absence of high-risk factors in clinical stage ({<=}T2b), Gleason score ({<=}7), and pretreatment PSA ({<=}20 ng/mL) was significantly associated with achieving nPSA <0.5 ng/mL. By Kaplan-Meier analysis, patients achieving nPSA <0.5 ng/mL had significantly higher long-term freedom from biochemical failure (FFBF) than nonresponders (5-year FFBF: 95.2 {+-} 0.8% vs. 71.5 {+-} 6.7%; p < 0.0005). Among responders, those who achieved nPSA <0.5 ng/mL in {<=}5 years had higher FFBF than those requiring >5 years (5-year FFBF: 96.7 {+-} 0.7% vs. 80.8 {+-} 4.6%; p < 0.0005). On multivariate analysis, patients who achieved nPSA <0.5 ng/mL in {<=}5 years had significantly higher FFBF than other patients. Conclusions: Pretreatment risk factors (clinical tumor stage, Gleason score, pretreatment PSA) strongly predict for patients achieving nPSA <0.5 ng/mL following brachytherapy, and this cohort had significantly higher long-term FFBF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗