Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Thermographic detection of cracks in thin sheets

A thermographic inspection technique for crack detection based on a 2D filter convolved with the thermal temperature images is presented. The filter is designed to approximate operating on the temperature images with a Laplacian operator. This operation yields an image which approximates changes in the heat flux in a thin plate. This filtering method results in an enhanced contrast due to the presence of cracks. Measurements have been performed on samples with fabricated electrical discharge machining (EDM) notches (both through-the-thickness and surface notches) and closed fatigue cracks around rivets. It is shown that the technique is effective for the detection of various crack lengths down to the resolution limits of the imager used.

Cramer, K. E.↗

Computed Tomography of Transverse Phase Space

Two computed tomography techniques are explored to reconstruct beam transverse phase space using both simulated beam and multi-wire profile data in the Fermilab Muon Test Area ("MTA") beamline. Both Filtered Back-Projection ("FBP") and Simultaneous Algebraic Reconstruction Technique ("SART") algorithms [2] are considered and compared. Errors and artifacts are compared as a function of each algorithm’s free parameters, and it is shown through simulation and MTA beamline profiles that SART is advantageous for reconstructions with limited profile data.

43 PARTICLE ACCELERATORS↗

The effects of cerium doping on the size, morphology, and optical properties of α-hematite nanoparticles for ultraviolet filtration

Highlights: • Possible application of cerium-doped α-hematite as ultraviolet filter. • Nanoparticles obtained through co-precipitation technique using various cerium doping levels followed by annealing. • Comprehensive materials characterisation utilizing XRD, DSC/TGA, STEM, UV–vis spectroscopy. • Increasing cerium content reduces particle sizing and alters morphology. • Solubility of cerium in hematite seen between 5 and 10% doping, 10% cerium doping greatly enhances attenuation in ultraviolet region and increases optical bandgap. - Abstract: Metal oxide nanoparticles have potential use in energy storage, electrode materials, as catalysts and in the emerging field of nanomedicine. Being able to accurately tailor the desirable properties of these nanoceramic materials, such as particle size, morphology and optical bandgap (E{sub g}) is integral in the feasibility of their use. In this study we investigate the altering of both the structure and physical properties through the doping of hematite (α-Fe{sub 2}O{sub 3}) nanocrystals with cerium at a range of concentrations, synthesised using a one-pot co-precipitation method. This extremely simple synthesis followed by thermal treatment results in stable Fe{sub 2−x}Ce{sub x}O{sub y} nanoceramics resulting from the burning of any unreacted precursors and transformation of goethite-cerium doped nanoparticle intermediate. The inclusion of Ce into the crystal lattice of these α-Fe{sub 2}O{sub 3} nanoparticles causes a significantly large reduction in mean crystalline size and alteration in particle morphology with increasing cerium content. Finally we report an increase optical semiconductor bandgap, along with a substantial increase in the ultraviolet attenuation found for a 10% Ce-doping concentration which shows the potential application of cerium-doped hematite nanocrystals to be used as a pigmented ultraviolet filter for cosmetic products.

36 MATERIALS SCIENCE↗

Model-Based Ultrasonic SignalProcessing for the Nondestructive Evaluation of Additive Manufacturing Components

Ultrasonic testing (UT) for nondestructive evaluation (NDE) is a critical entity necessary to resolve both the quality and precision questions of complex parts evolving from the innovative additive manufacturing (AM) process. This modality provides the essential quantitative information for acceptance and potential flaw detection of the part under investigation. A primary ingredient in UT besides the required precision robotic hardware for the acquisition of high quality measurement data is the underlying signal processing. It is here that much of the system performance capability resides. In this report, we discuss the basic steps in UT signal processing along with current and future capabilities that must be achieved in order to satisfy the critical demands created by the AM process. In its basic foundations, signal processing is essentially the “extraction of critical information (signals) from noisy, uncertain data.” Clearly, in a perfect world the best signal processing is none---just make a reliable, noise-free, uncertainty-free, measurement. Unfortunately, even the best of systems is still straddled within the confines and limitations of physical instrumentation. With this in mind, we discuss the development of signal processing techniques to extract the desired UT information from noisy measurement data. We start with a discussion of a simple homogeneous representation of a “part” under investigation and its insonification by an ultrasonic excitation from a physics-based perspective. Once developed, we briefly discuss the various choices of excitation signals and their tradeoffs. Next we discuss a simulation approach employing simple models from the signal processing perspective and then move on to the development of the basic signal processing approach to ultrasonic signal processing all based on estimating the pulse arrival estimation. Starting with simple peak detection techniques, progressing to the processing workhorse so-called “matched-filter” and finally to the more sophisticated “model-based matched filter.” The underlying pre- and post-processing of noisy measurement data along with the application of these techniques are subsequently demonstrated on experimental ultrasonic data. Finally, we discuss some open problems in UT and suggest a much more sophisticated model-based approach expanding these revolutionary ideas and encompassing more realistic signal models that incorporate noise, jitter and other pertinent uncertainties into the processor.

36 MATERIALS SCIENCE↗

Principal Component Noise Filtering for NAST-I Radiometric Calibration

The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Airborne Sounder Testbed- Interferometer (NAST-I) instrument is a high-resolution scanning interferometer that measures emitted thermal radiation between 3.3 and 18 microns. The NAST-I radiometric calibration is achieved using internal blackbody calibration references at ambient and hot temperatures. In this paper, we introduce a refined calibration technique that utilizes a principal component (PC) noise filter to compensate for instrument distortions and artifacts, therefore, further improve the absolute radiometric calibration accuracy. To test the procedure and estimate the PC filter noise performance, we form dependent and independent test samples using odd and even sets of blackbody spectra. To determine the optimal number of eigenvectors, the PC filter algorithm is applied to both dependent and independent blackbody spectra with a varying number of eigenvectors. The optimal number of PCs is selected so that the total root-mean-square (RMS) error is minimized. To estimate the filter noise performance, we examine four different scenarios: apply PC filtering to both dependent and independent datasets, apply PC filtering to dependent calibration data only, apply PC filtering to independent data only, and no PC filters. The independent blackbody radiances are predicted for each case and comparisons are made. The results show significant reduction in noise in the final calibrated radiances with the implementation of the PC filtering algorithm.

Tian, Jialin↗

High-frequency ECG

The standard ECG is by convention limited to 0.05-150 Hz, but higher frequencies are also present in the ECG signal. With high-resolution technology, it is possible to record and analyze these higher frequencies. The highest amplitudes of the high-frequency components are found within the QRS complex. In past years, the term "high frequency", "high fidelity", and "wideband electrocardiography" have been used by several investigators to refer to the process of recording ECGs with an extended bandwidth of up to 1000 Hz. Several investigators have tried to analyze HF-QRS with the hope that additional features seen in the QRS complex would provide information enhancing the diagnostic value of the ECG. The development of computerized ECG-recording devices that made it possible to record ECG signals with high resolution in both time and amplitude, as well as better possibilities to store and process the signals digitally, offered new methods for analysis. Different techniques to extract the HF-QRS have been described. Several bandwidths and filter types have been applied for the extraction as well as different signal-averaging techniques for noise reduction. There is no standard method for acquiring and quantifying HF-QRS. The physiological mechanisms underlying HF-QRS are still not fully understood. One theory is that HF-QRS are related to the conduction velocity and the fragmentation of the depolarization wave in the myocardium. In a three-dimensional model of the ventricles with a fractal conduction system it was shown that high numbers of splitting branches are associated with HF-QRS. In this experiment, it was also shown that the changes seen in HF-QRS in patients with myocardial ischemia might be due to the slowing of the conduction velocity in the region of ischemia. This mechanism has been tested by Watanabe et al by infusing sodium channel blockers into the left anterior descending artery in dogs. In their study, 60 unipolar ECGs were recorded from the entire ventricular surface and were signal-averaged and filtered in the 30-250 Hz frequency range. The results showed that the decrease noted in the HF-QRS correlated linearly with the local conduction delay. The results suggest that HF-QRS is a potent indicator of disturbed local conduction. An alternative theory is that HF-QRS reflect the shape of the original electrocardiographic signal. Bennhagen et al showed that root mean square (RMS) voltage values of the depolarization signal correlate poorly with the signal amplitude but highly with the first and second derivatives, i.e. the velocity and the acceleration of the signal. It has also been suggested that the autonomic nervous system affects HF-QRS. For example, sitting up causes significant changes in HF-QRS in some leads compared to the supine position [Douglas et al., 2006]. Unpublished results indicate that familial dysautonomic patients (both vagal and sympathetic degeneration) have very little Reduced Amplitude Zones (RAZ) formation . Athletic individuals, especially elite athletes, who have vagally-mediated changes on the conventional ECG (i.e. early repolarization, bradycardia) have increased RAZ formation. Further electrophysiological studies are needed, however, to better understand the underlying mechanisms of HF-QRS. Several investigators have studied HF-QRS in different cardiac conditions, including acute myocardial ischemia and myocardial infarction (MI). However, in order for clinicians to confidently use HF-QRS as an adjunct to standard ECG, more knowledge about the characteristics of HF-QRS is needed.

Tragardh, Elin↗

Development of an optimal automatic control law and filter algorithm for steep glideslope capture and glideslope tracking

A digital automatic control law to capture a steep glideslope and track the glideslope to a specified altitude is developed for the longitudinal/vertical dynamics of a CTOL aircraft using modern estimation and control techniques. The control law uses a constant gain Kalman filter to process guidance information from the microwave landing system, and acceleration from body mounted accelerometer data. The filter outputs navigation data and wind velocity estimates which are used in controlling the aircraft. Results from a digital simulation of the aircraft dynamics and the control law are presented for various wind conditions.

Halyo, N.↗

Design and performance of the cryogenic focal plane optics assembly for the Infrared Astronomical Satellite (IRAS)

The Infrared Astronomical Satellite (IRAS) has successfully completed its mission of providing an unbiased all-sky survey of astronomical objects in the 8 to 120 micrometer wavelength region. The design and performance of the Focal Plane Optics Assembly (FPOA) for the IRAS instrument is described in this paper. The FPOA consists of 62 survey field stops, 62 individual small field lenses, 124 small spectral filters, and a precision multi-part aluminum housing. The FPOA is capable of repeated thermal cycling from ambient temperature to 2 Kelvin. The spectral filters, along with the detector spectral responses, provide infrared bandpasses of 8-15, 18-30, 46-78, and 85-117 micrometers. The combination of very long wavelengths, liquid helium temperatures, and small size provided a significant design challenge. Spectral filter and field lens designs for the four spectral bands are described. Also, discussed are techniques which were developed for mechanical mounting of the small lenses and spectral filters, and to assure their optical alignment.

Bamberg, J. A.↗

Time-of-Flight Estimation for Nondestructive Evaluation

Ultrasonic testing (UT) for nondestructive evaluation (NDE) is a critical entity necessary to resolve both the quality and precision questions of complex parts evolving from the classical approaches to the innovative additive manufacturing (AM) process. This modality provides the essential quantitative information for acceptance and potential flaw detectionof apart under investigation. A primary ingredient in UT besides the required precision robotic hardware for theacquisition of high-qualitymeasurement data is the underlying signal processing. It is here that much of the system performance capability resides. In this report,we discuss the basic steps in UT signal processing along with current capabilities that must be achieved in order to satisfy the criticaldemands of the various LLNL programs.In itsbasic foundations, signal processing is essentially the “extraction of critical information (signals) from noisy, uncertain data.” Clearly, in a perfect world the best signal processing is none---just make a reliable, noise-free, uncertainty-free, measurement. Unfortunately, even the best of systems is still straddled within the confines and limitations of physical instrumentation. With this in mind, we discuss the development of signal processing techniques toextract the desired UT information from noisy measurement data. We start with a discussion of a simple homogeneous representation of a “part” under investigation and its insonification by an ultrasonicexcitation from a physics-based perspective. Once developed, we briefly discussthe various choices of excitation signals and their tradeoffs.Next,we discuss a simulation approach employing simple models from the signal processing perspective and then move on to the development of the basic signal processing approach to ultrasonic signal processing all based on estimating the pulse arrival estimation. Starting with simple peak detection techniques, progressing to the processing workhorse so-called “matched-filter” and finally to the more sophisticated “model-based matched filter.”The underlying pre-and post-processing of noisy measurement data along with the application of these techniques are subsequently demonstrated on experimental ultrasonic data.Finally, we present some results for processing “weld” data when the ultrasonic excitation signal is not directly available.

42 ENGINEERING↗

A NUMERICAL METHOD FOR THE VISUALIZATION OF THE Fe XIV EMISSION IN THE SOLAR CORONA USING BROADBAND FILTERS

The goal of this article is to demonstrate how the emission from the Fe XIV 530.3 nm coronal emission line, also known as the green line, can be extracted from images taken during total solar eclipses with commercially available color cameras. This concept is technically feasible because Fe XIV is the brightest optical emission line in the inner corona, and because the sensors of these cameras are retrofitted with a standard Bayer mask, namely, a square grid of spectrally broad (about 100 nm) green, blue, and red filters in the ratio of 2:1:1. The technique presented here, and developed for this purpose, yields qualitatively accurate Fe XIV images, as tested by comparing with Fe XIV eclipse images taken with a 0.15 nm narrow-bandpass filter. While this approach cannot replace narrow-bandpass Fe XIV images for quantitative studies of the corona, it provides a simple and affordable tool for studying the morphology of coronal structures emitting preferentially at the peak ionization temperature of Fe XIV, namely, 1.8 Multiplication-Sign 10{sup 6} K.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a narrow stopband filter for spectroscopic fast ion deuterium-alpha measurements

A new technique to attenuate the unshifted deuterium Balmer-alpha (D-alpha) emission is developed and tested for the fast ion D-alpha (FIDA) diagnostic. The unshifted D-alpha emission, at λ = 656.1 nm, is around three orders of magnitude higher than the desired FIDA emission. Blocking the strong emission feature is essential to prevent blooming and light smearing on the CCD chip and scattered light contamination. The new method is a notch filter approach that utilizes the reflection from ultra-narrow bandpass filters to block the saturating signal before it enters the spectrometer. Collimated light from the fibers is reflected off the filter at a 15° angle of incidence. Measurements show that a center wavelength transmission of 0.006 and a blocking full width at half maximum of ~ 1 nm are achieved by using a 200 μm fiber and a 20 mm focal length collimator with two filters.

47 OTHER INSTRUMENTATION↗

A prototype fan-beam optical CT scanner for 3D dosimetry

Purpose: The objective of this work is to introduce a prototype fan-beam optical computed tomography scanner for three-dimensional (3D) radiation dosimetry. Methods: Two techniques of fan-beam creation were evaluated: a helium-neon laser (HeNe, {lambda} = 543 nm) with line-generating lens, and a laser diode module (LDM, {lambda} = 635 nm) with line-creating head module. Two physical collimator designs were assessed: a single-slot collimator and a multihole collimator. Optimal collimator depth was determined by observing the signal of a single photodiode with varying collimator depths. A method of extending the dynamic range of the system is presented. Two sample types were used for evaluations: nondosimetric absorbent solutions and irradiated polymer gel dosimeters, each housed in 1 liter cylindrical plastic flasks. Imaging protocol investigations were performed to address ring artefacts and image noise. Two image artefact removal techniques were performed in sinogram space. Collimator efficacy was evaluated by imaging highly opaque samples of scatter-based and absorption-based solutions. A noise-based flask registration technique was developed. Two protocols for gel manufacture were examined. Results: The LDM proved advantageous over the HeNe laser due to its reduced noise. Also, the LDM uses a wavelength more suitable for the PRESAGE{sup TM} dosimeter. Collimator depth of 1.5 cm was found to be an optimal balance between scatter rejection, signal strength, and manufacture ease. The multihole collimator is capable of maintaining accurate scatter-rejection to high levels of opacity with scatter-based solutions (T < 0.015%). Imaging protocol investigations support the need for preirradiation and postirradiation scanning to reduce reflection-based ring artefacts and to accommodate flask imperfections and gel inhomogeneities. Artefact removal techniques in sinogram space eliminate streaking artefacts and reduce ring artefacts of up to {approx}40% in magnitude. The flask registration technique was shown to achieve submillimetre and subdegree placement accuracy. Dosimetry protocol investigations emphasize the need to allow gel dosimeters to cool gradually and to be scanned while at room temperature. Preliminary tests show that considerable noise reduction can be achieved with sinogram filtering and by binning image pixels into more clinically relevant grid sizes. Conclusions: This paper describes a new optical CT scanner for 3D radiation dosimetry. Tests demonstrate that it is capable of imaging both absorption-based and scatter-based samples of high opacities. Imaging protocol and gel dosimeter manufacture techniques have been adapted to produce optimal reconstruction results. These optimal results will require suitable filtering and binning techniques for noise reduction purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Data Reconciliation and Validation of a Dynamic Model for Solvent-Based CO 2 Capture Using Pilot-Plant Data

This paper is focused on the development and validation of a dynamic model for an MEA-based CO 2 capture unit. Starting with a rigorous steady-state process model, the dynamic model is developed in Aspen Plus Dynamics ® using a modified Murphree-efficiency approach and is validated using dynamic data collected from the National Carbon Capture Center (NCCC) in Wilsonville, Alabama. The dynamic test runs were designed with due consideration of process excitation and process nonlinearities constrained by the available time to conduct the test runs and implement the experimental designs in the plant control system. The experimental data include solvent composition and loading. Since the experimental data were found to violate mass and energy balances, filtering algorithms coupled with dynamic data reconciliation techniques were used. Without adjusting any model parameters, the dynamic model satisfactorily predicted dynamic response of CO 2 capture due to step changes in the solvent flowrate, flue gas flowrate, and steam flowrates. Transient studies show that the process gain and time constants can considerably change depending on the direction of the disturbance or manipulated variables, indicating process nonlinearities. Due to a storage tank between the absorber and stripper, the time constant of the full plant can be considerably longer than the time constants of the absorber or stripper individually. Furthermore, impact of the control system on the process efficiency while following an optimal CO 2 capture schedule was also studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data Unfolding with Wiener-SVD Method

Here, data unfolding is a common analysis technique used in HEP data analysis. Inspired by the deconvolution technique in the digital signal processing, a new unfolding technique based on the SVD technique and the well-known Wiener filter is introduced. The Wiener-SVD unfolding approach achieves the unfolding by maximizing the signal to noise ratios in the effective frequency domain given expectations of signal and noise and is free from regularization parameter. Through a couple examples, the pros and cons of the Wiener-SVD approach as well as the nature of the unfolded results are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gravitational wave extraction in simulations of rotating stellar core collapse

We perform simulations of general relativistic rotating stellar core collapse and compute the gravitational waves (GWs) emitted in the core-bounce phase of three representative models via multiple techniques. The simplest technique, the quadrupole formula (QF), estimates the GW content in the spacetime from the mass-quadrupole tensor only. It is strictly valid only in the weak-field and slow-motion approximation. For the first time, we apply GW extraction methods in core collapse that are fully curvature based and valid for strongly radiating and highly relativistic sources. These techniques are not restricted to weak-field and slow-motion assumptions. We employ three extraction methods computing (i) the Newman-Penrose (NP) scalar {Psi}{sub 4}, (ii) Regge-Wheeler-Zerilli-Moncrief master functions, and (iii) Cauchy-characteristic extraction (CCE) allowing for the extraction of GWs at future null infinity, where the spacetime is asymptotically flat and the GW content is unambiguously defined. The latter technique is the only one not suffering from residual gauge and finite-radius effects. All curvature-based methods suffer from strong nonlinear drifts. We employ the fixed-frequency integration technique as a high-pass waveform filter. Using the CCE results as a benchmark, we find that finite-radius NP extraction yields results that agree nearly perfectly in phase, but differ in amplitude by {approx}1%-7% at core bounce, depending on the model. Regge-Wheeler-Zerilli-Moncrief waveforms, while, in general, agreeing in phase, contain spurious high-frequency noise of comparable amplitudes to those of the relatively weak GWs emitted in core collapse. We also find remarkably good agreement of the waveforms obtained from the QF with those obtained from CCE. The results from QF agree very well in phase and systematically underpredict peak amplitudes by {approx}5%-11%, which is comparable to the NP results and is certainly within the uncertainties associated with core collapse physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors

Purpose: As the practice of using high-energy photon beams to create therapeutic radiation fields of subcentimeter dimensions (as in intensity-modulated radiotherapy or stereotactic radiosurgery) grows, so too does the need for accurate verification of beam output at these small fields in which standard practices of dose verification break down. This study investigates small-field output factors measured using a small plastic scintillation detector (PSD), as well as a 0.01 cm{sup 3} ionization chamber. Specifically, output factors were measured with both detectors using small fields that were defined by either the X-Y collimator jaws or the multileaf collimator (MLC). Methods: A PSD of 0.5 mm diameter and 2 mm length was irradiated with 6 and 18 MV linac beams. The PSD was positioned vertically at a source-to-axis distance of 100 cm, at 10 cm depth in a water phantom, and irradiated with fields ranging in size from 0.5x0.5 to 10x10 cm{sup 2}. The field sizes were defined either by the collimator jaws alone or by a MLC alone. The MLC fields were constructed in two ways: with the closed leaves (i.e., those leaves that were not opened to define the square field) meeting at either the field center line or at a 4 cm offset from the center line. Scintillation light was recorded using a CCD camera and an estimation of error in the median-filtered signals was made using the bootstrapping technique. Measurements were made using a CC01 ionization chamber under conditions identical to those used for the PSD. Results: Output factors measured by the PSD showed close agreement with those measured using the ionization chamber for field sizes of 2.0x2.0 cm{sup 2} and above. At smaller field sizes, the PSD obtained output factors as much as 15% higher than those found using the ionization chamber by 0.6x0.6 cm{sup 2} jaw-defined fields. Output factors measured with no offset of the closed MLC leaves were as much as 20% higher than those measured using a 4 cm leaf offset. Conclusions: The authors' results suggest that PSDs provide a useful and possibly superior alternative to existing dosimetry systems for small fields, as they are inherently less susceptible to volume-averaging and perturbation effects than larger, air-filled ionization chambers. Therefore, PSDs may provide more accurate small-field output factor determination, regardless of the collimation mechanism.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray computed tomography using curvelet sparse regularization

Purpose: Reconstruction of x-ray computed tomography (CT) data remains a mathematically challenging problem in medical imaging. Complementing the standard analytical reconstruction methods, sparse regularization is growing in importance, as it allows inclusion of prior knowledge. The paper presents a method for sparse regularization based on the curvelet frame for the application to iterative reconstruction in x-ray computed tomography. Methods: In this work, the authors present an iterative reconstruction approach based on the alternating direction method of multipliers using curvelet sparse regularization. Results: Evaluation of the method is performed on a specifically crafted numerical phantom dataset to highlight the method’s strengths. Additional evaluation is performed on two real datasets from commercial scanners with different noise characteristics, a clinical bone sample acquired in a micro-CT and a human abdomen scanned in a diagnostic CT. The results clearly illustrate that curvelet sparse regularization has characteristic strengths. In particular, it improves the restoration and resolution of highly directional, high contrast features with smooth contrast variations. The authors also compare this approach to the popular technique of total variation and to traditional filtered backprojection. Conclusions: The authors conclude that curvelet sparse regularization is able to improve reconstruction quality by reducing noise while preserving highly directional features.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Single Cells and Cell Populations Viability Estimation in vitro by the Time-Domain Impedance Spectroscopy

In the present study, we investigate the sensitivity and applicability of the time-domain electrical impedance spectroscopy (EIS) techniques, namely Fourier-EIS and adaptive filtering based EIS (AF-EIS), for studying cells' populations and single living cells in natural physiological environment in vitro. Using ultra-violet radiation for decreasing cell life-span we demonstrate the possibility to distinguish the living cells' population from the dead cells by both Fourier-EIS and AF-EIS. However, determining the viability of the single cell requires significant sensitivity, which is inaccessible with the conventional Fourier-EIS contrary to AF-EIS. The latter result stems from the high noise immunity of the AF-EIS, which also makes it possible to provide the measurements using the safe for cells 15-mV excitation voltage and 10–100 nA current response. The developed single-cell AF-EIS approach opens a direct roadmap for creating accurate, robust, and easy to implement toxin and radiation hazard sensors with the living cell as an acting element and proposes a solution for actual ecological and healthcare problems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗