Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Search for VHE {gamma}-ray emission in the vicinity of selected pulsars of the Northern Sky with VERITAS

It is generally believed that pulsars dissipate their rotational energy through powerful winds of relativistic particles. Confinement of these winds leads to the formation of luminous pulsar wind nebulae (PWNe) seen across the electromagnetic spectrum in synchrotron and inverse Compton emission. Recently, many new detections have been produced at the highest energies by Very High Energy (VHE){gamma}-ray observations, identifying PWNe as among the most common sources of galactic VHE {gamma}-ray emission. We report here on the preliminary results of a search for VHE {gamma}-ray emission towards a selection of energetic and/or close pulsars in the Northern hemisphere in the first year of operations of the full VERITAS array.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-dependent absorption of very high-energy gamma-rays from the Galactic center by pair-production

Very high energy (VHE) gamma-rays have been detected from the direction of the Galactic center. The H.E.S.S. Cherenkov telescopes have located this {gamma}-ray source with a preliminary position uncertainty of 8.5'' per axis (6'' statistic+6'' sytematic per axis). Within the uncertainty region several possible counterpart candidates exist: the Super Massive Black Hole Sgr A*, the Pulsar Wind Nebula candidate G359.95-0.04, the Low Mass X-Ray Binary-system J174540.0-290031, the stellar cluster IRS 13, as well as self-annihilating dark matter. It is experimentally very challenging to further improve the positional accuracy in this energy range and therefore, it may not be possible to clearly associate one of the counterpart candidates with the VHE-source. Here, we present a new method to investigate a possible link of the VHE-source with the near environment of Sgr A*(within approximately 1000 Schwarzschild radii). This method uses the time- and energy-dependent effect of absorption of VHE {gamma}-rays by pair-production (in the following named pair-eclipse) with low-energy photons of stars closely orbiting the SMBH Sgr A*.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a High-Average-Power Compton Gamma Source for Lepton Colliders

Gamma-({gamma}{sup -}) ray beams of high average power and peak brightness are of demand for a number of applications in high-energy physics, material processing, medicine, etc. One of such examples is gamma conversion into polarized positrons and muons that is under consideration for projected lepton colliders. A {gamma}-source based on the Compton backscattering from the relativistic electron beam is a promising candidate for this application. Our approach to the high-repetition {gamma}-source assumes placing the Compton interaction point inside a CO{sub 2} laser cavity. A laser pulse interacts with periodical electron bunches on each round-trip inside the laser cavity producing the corresponding train of {gamma}-pulses. The round-trip optical losses can be compensated by amplification in the active laser medium. The major challenge for this approach is in maintaining stable amplification rate for a picosecond CO{sub 2}-laser pulse during multiple resonator round-trips without significant deterioration of its temporal and transverse profiles. Addressing this task, we elaborated on a computer code that allows identifying the directions and priorities in the development of such a multi-pass picosecond CO{sub 2} laser. Proof-of-principle experiments help to verify the model and show the viability of the concept. In these tests we demonstrated extended trains of picosecond CO{sub 2} laser pulses circulating inside the cavity that incorporates the Compton interaction point.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards combining in-beam {gamma}-ray and conversion electron spectroscopy

The SAGE spectrometer will combine a segmented Si-detector with a Ge-detector array aiming to take the simultaneous in-beam {gamma}-ray and conversion electron spectroscopy to the next level. It will be coupled with the GREAT focal plane spectrometer and the RITU gas-filled recoil separator at the accelerator laboratory of the University of Jyvaeskylae, Finland. Its high efficiency and resolution will open the door to a new era of complete spectroscopy directed, amongst others, at the study of superheavy nuclei aiming to investigate the properties of the next spherical proton shell above Z = 82.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel LaBr{sub 3} based {gamma}-ray detection array for use at RIBF

With the RI Beam Factory at RIKEN being on the cusp to deliver the world's most intense radioactive ion beams at relativistic energies, a new {gamma}-ray detection array has been proposed to exploit the new experimental possibilities coming along with it. The material LaBr{sub 3}(Ce) possesses an unprecedentedly high intrinsic energy resolution for scintillators of {approx_equal}2% at 1.3 MeV and is therefore well suited for high-resolution in-beam {gamma}-ray experiments at relativistic energies. To minimize Doppler effects, the total array will comprise of up to one thousand individual crystals. It is intended to place the array around the secondary target area of the large acceptance fragment separator BigRIPS and use it either in a stand-alone mode or in addition to a reconfigured DALI2 array. Alternatively, the array will be used in a different configuration for stopped beam, delayed {gamma}-ray decay experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The new PGAA installation at the FRM II

At the new research reactor FRM II in Garching near Munich the beam guide with the highest cold neutron flux is dedicated to Prompt Gamma-ray Activation Analysis (PGAA) and related neutron capture experiments. We have designed a partially ballistic form of the neutron guide with the aim of concentrating the cold neutrons at the target position of the PGAA experiment. The cold neutron flux with a mean energy of only 1.83 meV was measured about 10.5 cm far from the second exit window and reached intensity of 1.7x10{sup 10} n/cm{sup 2} s at a 2 mmx2 mm gold foil. The PGAA installation is now prepared for three different kinds of measurements--standard PGAA, Neutron Tomography of small samples and position sensitive PGAA, or PGAI for short. We have also measured {gamma}{gamma} coincidences in {sup 77}Ge. In this paper, we want to introduce the PGAA facility, show the diversity of the recently performed experiments and discuss further possibilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The New Position Sensitive Triple Cluster Detector For AGATA

The first triple cluster detector was successfully assembled for the next generation high-resolution gamma-ray spectrometer: the Advanced Gamma Tracking Array AGATA. The core part of the detector consists of three encapsulated, 36-fold segmented, high-purity germanium detectors (HPGe) which are operated in a common cryostat. All 111 energy channels are equipped with cold FETs. They provide best energy resolution of core and segment signals. The observable energy range of the Ge detectors was extended up to 100 MeV by applying a time over threshold technique with the newly developed AGATA preamplifiers. Energy resolution for high energetic {gamma}-rays above 10 MeV is measured to be comparable with values obtained with the standard pulse height technique. Detailed cross-talk investigations were performed in order to improve position dependent pulse shape information. For the Ge detectors and its analog preamplifier circuitry a low cross-talk level was determined which compares well with the expected calculated contributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanism for low-etching resistance and surface roughness of ArF photoresist during plasma irradiation

ArF excimer laser lithography was introduced to fabricate nanometer-scale devices and uses chemically amplified photoresist polymers including photoacid generators (PAGs). Because plasma-etching processes cause serious problems related to the use of ArF photoresists, such as line-edge roughness and low etching selectivity, we have to understand the interaction between plasma and ArF photoresist polymers. Investigating the effects of surface temperature and the irradiation species from plasma, we have found that ion irradiation by itself did not drastically increase the roughness or etching rate of ArF photoresist films unless it was combined with ultraviolet/vacuum ultraviolet (UV/VUV) photon irradiation. The structures of ArF photoresist polymers were largely unchanged by ion irradiation alone but were destroyed by combinations of ion and UV/VUV-photon irradiation. Our results suggested that PAG-mediated deprotection induced by UV/VUV-photon irradiation was amplified at surface temperatures above 100 deg. C. The etching rate and surface roughness of plasma-etched ArF photoresists are affected by the irradiation species and surface temperature during plasma etching. UV/VUV-photon irradiation plays a particularly important role in the interaction between plasma and ArF photoresist polymers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gamma-Ray Tracking Detectors: Physics Opportunities and Status of GRETINA/GRETA

Gamma-ray tracking detectors using highly segmented germanium detectors will give higher efficiency, better peak-to-total ratio and much higher position resolution than current generation of detectors. Particularly, the capability of reconstructing the position of the interaction with millimeters resolution is needed to fully exploit the physics opportunities provided by the next generation radioactive beam facilities. This paper presents the basic concepts of tracking, examples of physics opportunities, and the status of the project GRETA/GRETINA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosing inertial confinement fusion gamma ray physics (invited)

The gamma reaction history (GRH) diagnostic is a multichannel, time-resolved, energy-thresholded {gamma}-ray spectrometer that provides a high-bandwidth, direct-measurement of fusion reaction history in inertial confinement fusion implosion experiments. 16.75 MeV deuterium+tritium (DT) fusion {gamma}-rays, with a branching ratio of the order of 10{sup -5}{gamma}/(14 MeV n), are detected to determine fundamental burn parameters, such as nuclear bang time and burn width, critical to achieving ignition at the National Ignition Facility. During the tritium/hydrogen/deuterium ignition tuning campaign, an additional {gamma}-ray line at 19.8 MeV, produced by hydrogen+tritium fusion with a branching ratio of unity, will increase the available {gamma}-ray signal and may allow measurement of reacting fuel composition or ion temperature. Ablator areal density measurements with the GRH are also made possible by detection of 4.43 MeV {gamma}-rays produced by inelastic scatter of DT fusion neutrons on {sup 12}C nuclei in the ablating plastic capsule material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A digital method for separation and reconstruction of pile-up events in germanium detectors

The problem of pulse pile-up is very often encountered in precise measurements of {gamma}-rays using germanium detectors. The standard method of treating the pile-up events is to identify and reject them using an appropriate electronic system. Digital acquisition techniques now allow the recording of waveforms of pile-up events that can be analyzed and the contributing single pulses recovered, rather than simply tolerating the losses associated with pile-up. In this paper, a method for the off-line digital processing of pile-up events from germanium detectors is demonstrated. The method is based on an appropriate fitting of the detector signals, shaped with a suitable digital pulse shaper. It is shown that the method is able to recover the pile-up events with good accuracy even when the constituent signals are in close proximity. The method is very useful for {gamma}-ray spectroscopy in nuclear physics experiments, where the low intensity signals can be lost due to the pile-up in a high-rate environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relativistic expansion of electron-positron-photon plasma droplets and photon emission

The expansion dynamics of hot electron-positron-photon plasma droplets is dealt with within relativistic hydrodynamics. Such droplets, envisaged to be created in future experiments by irradiating thin foils with counterpropagating ultraintense laser beams, are sources of flashes of gamma radiation. Warm electron-positron plasma droplets may be identified and characterized by a broadened 511 keV line.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma ray optics

Via refractive or diffractive scattering one can shape {gamma} ray beams in terms of beam divergence, spot size and monochromaticity. These concepts might be particular important in combination with future highly brilliant gamma ray sources and might push the sensibility of planned experiments by several orders of magnitude. We will demonstrate the experimental feasibility of gamma ray monochromatization on a ppm level and the creation of a gamma ray beam with nanoradian divergence. The results are obtained using the inpile target position of the High Flux Reactor of the ILL Grenoble and the crystal spectrometer GAMS. Since the refractive index is believed to vanish to zero with 1/E{sup 2}, the concept of refractive optics has never been considered for gamma rays. The combination of refractive optics with monochromator crystals is proposed to be a promising design. Using the crystal spectrometer GAMS, we have measured for the first time the refractive index at energies in the energy range of 180 - 2000 keV. The results indicate a deviation from simple 1/E{sup 2} extrapolation of X-ray results towards higher energies. A first interpretation of these new results will be presented. We will discuss the consequences of these results on the construction of refractive optics such as lenses or refracting prisms for gamma rays and their combination with single crystal monochromators.

43 PARTICLE ACCELERATORS↗

Pile-up recovery in gamma-ray detection

Count rates in gamma-ray detectors are fundamentally limited at the high end by the physics of the detection process but should not be limited further by the design of read-out. Using intense stimuli, such as the ELI, it is desirable to extract the full wealth of information flow that sensors can deliver. We discuss the photon-statistical limitations of scintillation systems and charge-collection issues of solid-state detectors. With high-speed digitizing in particular, two promising approach architectures are those of posterior list mode corrections and of time-domain adaptive filters, introducing a 'rich list mode with uncertainties' and thus a somewhat different look at experimental spectra. Real-time performance is also considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-to-electron magnetic spectrometer (GEMS): An energy-resolved {gamma}-ray diagnostic for the National Ignition Facility

The gamma-to-electron magnetic spectrometer, having better than 5% energy resolution, is proposed to resolve {gamma}-rays in the range of E{sub o}{+-} 20% in single shot, where E{sub o} is the central energy and is tunable from 2 to 25 MeV. Gamma-rays from inertial confinement fusion implosions interact with a thin Compton converter (e.g., beryllium) located at approximately 300 cm from the target chamber center (TCC). Scattered electrons out of the Compton converter enter an electromagnet placed outside the NIF chamber (approximately 600 cm from TCC) where energy selection takes place. The electromagnet provides tunable E{sub o} over a broad range in a compact manner. Energy resolved electrons are measured by an array of quartz Cherenkov converters coupled to photomultipliers. Given 100 detectable electrons in the energy bins of interest, 3 Multiplication-Sign 10{sup 14} minimum deuterium/tritium (DT) neutrons will be required to measure the 4.44 MeV {sup 12}C {gamma}-rays assuming 200 mg/cm{sup 2} plastic ablator areal density and 3 Multiplication-Sign 10{sup 15} minimum DT neutrons to measure the 16.75 MeV DT {gamma}-ray line.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high resolution gamma-ray spectrometer based on superconducting microcalorimeters

Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gamma-ray microcalorimeters, based on transition-edge sensors (TESs), possible. At these collecting areas, gamma microcalorimeters can utilize their unprecedented energy resolution to perform spectroscopy in a number of applications that are limited by closely-spaced spectral peaks, for example, the nondestructive analysis of nuclear materials. We have built a 256 pixel spectrometer with an average full-width-at-half-maximum energy resolution of 53 eV at 97 keV, a useable dynamic range above 400 keV, and a collecting area of 5 cm{sup 2}. We have demonstrated multiplexed readout of the full 256 pixel array with 236 of the pixels (91%) giving spectroscopic data. This is the largest multiplexed array of TES microcalorimeters to date. This paper will review the spectrometer, highlighting the instrument design, detector fabrication, readout, operation of the instrument, and data processing. Further, we describe the characterization and performance of the newest 256 pixel array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Compton gamma-ray sources at LLNL

Compact Compton scattering gamma-ray sources offer the potential of studying nuclear photonics with new tools. The optimization of such sources depends on the final application, but generally requires maximizing the spectral density (photons/eV) of the gamma-ray beam while simultaneously reducing the overall bandwidth on target to minimize noise. We have developed an advanced design for one such system, comprising the RF drive, photoinjector, accelerator, and electron-generating and electron-scattering laser systems. This system uses a 120 Hz, 250 pC, 2 ps, 0.35 mm mrad electron beam with 250 MeV maximum energy in an X-band accelerator scattering off a 150 mJ, 10 ps, 532 nm laser to generate 5 Multiplication-Sign 10{sup 10} photons/eV/s/Sr at 0.5 MeV with an overall bandwidth of less than 1%. The source will be able to produce photons up to energies of 2.5 MeV. We also discuss Compton scattering gamma-ray source predictions given by numerical codes.

43 PARTICLE ACCELERATORS↗

Quantitative comparison between PGNAA measurements and MCNP calculations in view of the characterization of radioactive wastes in Germany and France

The Forschungszentrum Juelich GmbH (FZJ), together with the Aachen University Rheinisch-Westfaelische Technische Hochschule (RWTH) and the French Alternative Energies and Atomic Energy Commission (CEA Cadarache) are involved in a cooperation aiming at characterizing toxic and reactive elements in radioactive waste packages by means of Prompt Gamma Neutron Activation Analysis (PGNAA). The French and German waste management agencies have indeed defined acceptability limits concerning these elements in view of their projected geological repositories. A first measurement campaign was performed in the new Prompt Gamma Neutron Activation Analysis (PGNAA) facility called MEDINA, at FZJ, to assess the capture gamma-ray signatures of some elements of interest in large samples up to waste drums with a volume of 200 liter. MEDINA is the acronym for Multi Element Detection based on Instrumental Neutron Activation. This paper presents MCNP calculations of the MEDINA facility and quantitative comparison between measurement and simulation. Passive gamma-ray spectra acquired with a high purity germanium detector and calibration sources are used to qualify the numerical model of the crystal. Active PGNAA spectra of a sodium chloride sample measured with MEDINA then allow for qualifying the global numerical model of the measurement cell. Chlorine indeed constitutes a usual reference with reliable capture gamma-ray production data. The goal is to characterize the entire simulation protocol (geometrical model, nuclear data, and postprocessing tools) which will be used for current measurement interpretation, extrapolation of the performances to other types of waste packages or other applications, as well as for the study of future PGNAA facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗