Initial Assessment for a Generic Horizontal Fissile Solution Vessel with an Electron Beam-based Neutron Generator
The LANL NA-23 program office has provided an extensive design study for a medical isotope (i.e. Molybdenum-99) production facility based on a fissile solution vessel with various accelerator technologies. These concept designs and associated R&D have provided affordable pathways for system optimization for industry counter partner such as SHINE and Global Medial Isotope Supply (GMIS). A horizontal fissile solution vessel design with an electron beam (E-beam) accelerator is proposed and studied with modeling capabilities developed for previous concepts (i.e. a generic vertical fissile solution vessel with a deuterium-tritium (DT) accelerator). An initial system assessment is performed by estimating theoretical Molybdenum-99 production yield with MCNP6.2. A baseline system configuration is constructed based on early design discussions between LANL and GMIS. Since only an initial design concept is available at this stage, all associated system design parameters can be adjusted to fit the best system performance characteristics. In this work, unlike previous vertical system studies, the cooling configuration of the horizontal fissile solution vessel is not considered, and only fission reactions are used to quantify the theoretical product yield. Five parametric design studies are proposed, preliminary results are briefly reported, and extended design studies beyond what is proposed here are also discussed. It is concluded that a comprehensive system analysis via multiphysics coupled calculation developed by LANL should be further conducted for the final design.