Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Coverage of Axillary Lymph Nodes in Supine vs. Prone Breast Radiotherapy

Purpose: To compare the dosimetry of target and normal tissue when tangents with the breast tissue were applied in a subset of breast cancer patients who had undergone computed tomography (CT) planning both supine and prone. Methods and Materials: The CT images of 20 patients who had undergone simulation in supine and prone positions were used for planning. The axillary lymph node regions (level I-III), breast tissue, tumor bed, heart, and bilateral lungs were manually contoured. Standard tangent fields were designed for the whole breast to deliver a prescribed dose of 50 Gy. Dose-volume histograms were compared between the two sets. Results: In each patient, coverage of breast tissue and tumor bed was readily achieved by either technique. In either position, treatment of the nodal regions was inadequate. On average, the mean dose to the nodal regions for levels I-III was {approx}50% less in the prone as compared with the supine position. The mean ipsilateral lung volume receiving 95% of the prescribed dose was 6.3% in the supine position compared to 0.43% in the prone position. When planned supine, the mean heart volume receiving 30 Gy was 0.56% compared with 0.30% in the prone position. Conclusions: Planning in either position was found to achieve adequate coverage of the breast tissue and tumor bed for all patients. Lung was better spared prone. Coverage of axillary nodes was inadequate in either position, but further reduced in the prone vs. supine position. The choice of optimal setup should take into considerations stage and risk of nodal recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Planning Study Comparison of Real-Time Target Tracking and Four-Dimensional Inverse Planning for Managing Patient Respiratory Motion

Purpose: Real-time target tracking (RT-TT) and four-dimensional inverse planning (4D-IP) are two potential methods to manage respiratory target motion. In this study, we evaluated each method using the cumulative dose-volume criteria in lung cancer radiotherapy. Methods and Materials: Respiration-correlated computed tomography scans were acquired for 4 patients. Deformable image registration was applied to generate a displacement mapping for each phase image of the respiration-correlated computed tomography images. First, the dose distribution for the organs of interest obtained from an idealized RT-TT technique was evaluated, assuming perfect knowledge of organ motion and beam tracking. Inverse planning was performed on each phase image separately. The treatment dose to the organs of interest was then accumulated from the optimized plans. Second, 4D-IP was performed using the probability density function of respiratory motion. The beam arrangement, prescription dose, and objectives were consistent in both planning methods. The dose-volume and equivalent uniform dose in the target volume, lung, heart, and spinal cord were used for the evaluation. Results: The cumulative dose in the target was similar for both techniques. The equivalent uniform dose of the lung, heart, and spinal cord was 4.6 {+-} 2.2, 11 {+-} 4.4, and 11 {+-} 6.6 Gy for RT-TT with a 0-mm target margin, 5.2 {+-} 3.1, 12 {+-} 5.9, and 12 {+-} 7.8 Gy for RT-TT with a 2-mm target margin, and 5.3 {+-} 2.3, 11.9 {+-} 5.0, and 12 {+-} 5.6 Gy for 4D-IP, respectively. Conclusion: The results of our study have shown that 4D-IP can achieve plans similar to those achieved by RT-TT. Considering clinical implementation, 4D-IP could be a more reliable and practical method to manage patient respiration-induced motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Results on Setup Precision of Prone-Lateral Patient Positioning for Whole Breast Irradiation

Purpose: The aim of this study was to develop a rapid and reproducible technique for prone positioning and to compare dose-volume indices in prone and supine positions. Methods and Materials: Eighteen patients underwent computed tomography imaging for radiotherapy planning in prone and supine position. Experience was gained in the first eight patients, which lead to modifications of the Horizon prone breast board (Civco Medical Solutions, Orange City, Iowa, USA) and the patient setup technique. A unilateral breast holder (U-BH) was developed (Van de Velde, Schellebelle, Belgium) to retract the contralateral breast away from the treated breast. The technique was then applied to an additional 10 patients. The setup precision was evaluated using daily cone-beam CT. Results: Modifications to the breast board were made to secure a prone-lateral rather then a pure prone position. We evolved from a classical setup using laser marks on the patients' body to a direct breast setup using marks on the breast only. The setup precision of the direct positioning procedure with the modified breast board and the U-BH is comparable to supine setup data in the literature. Dose-volume indices for heart and lung show significantly better results for prone than for supine position, and dose homogeneity within the treated breast did not differ according to the treatment position. Conclusions: The setup precision of our prone-lateral positioning technique is comparable to supine data in literature. Our data show the advantage of prone radiotherapy to spare the lung and heart. Further research is necessary to reduce the duration of prone setup.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Continuous Arc Rotation of the Couch Therapy for the Delivery of Accelerated Partial Breast Irradiation: A Treatment Planning Analysis

Purpose: We present a novel form of arc therapy: continuous arc rotation of the couch (C-ARC) and compare its dosimetry with three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated arc therapy (VMAT) for accelerated partial breast irradiation (APBI). C-ARC, like VMAT, uses a modulated beam aperture and dose rate, but with the couch, not the gantry, rotating. Methods and Materials: Twelve patients previously treated with APBI using 3D-CRT were replanned with (1) C-ARC, (2) IMRT, and (3) VMAT. C-ARC plans were designed with one medial and one lateral arc through which the couch rotated while the gantry was held stationary at a tangent angle. Target dose coverage was normalized to the 3D-CRT plan. Comparative endpoints were dose to normal breast tissue, lungs, and heart and monitor units prescribed. Results: Compared with 3D-CRT, C-ARC, IMRT, and VMAT all significantly reduced the ipsilateral breast V50% by the same amount (mean, 7.8%). Only C-ARC and IMRT plans significantly reduced the contralateral breast maximum dose, the ipsilateral lung V5Gy, and the heart V5%. C-ARC used on average 40%, 30%, and 10% fewer monitor units compared with 3D-CRT, IMRT, and VMAT, respectively. Conclusions: C-ARC provides improved dosimetry and treatment efficiency, which should reduce the risks of toxicity and secondary malignancy. Its tangent geometry avoids irradiation of critical structures that is unavoidable using the en face geometry of VMAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Forward Intensity-Modulated Radiotherapy Planning in Breast Cancer to Improve Dose Homogeneity: Feasibility of Class Solutions

Purpose: To explore forward planning methods for breast cancer treatment to obtain homogeneous dose distributions (using International Commission on Radiation Units and Measurements criteria) within normal tissue constraints and to determine the feasibility of class solutions. Methods and Materials: Treatment plans were optimized in a stepwise procedure for 60 patients referred for postlumpectomy irradiation using strict dose constraints: planning target volume (PTV){sub 95%} of >99%; V{sub 107%} of <1.8 cc; heart V{sub 5Gy} of <10% and V{sub 10Gy} of <5%; and mean lung dose of <7 Gy. Treatment planning started with classic tangential beams. Optimization was done by adding a maximum of four segments before adding beams, in a second step. A breath-hold technique was used for heart sparing if necessary. Results: Dose constraints were met for all 60 patients. The classic tangential beam setup was not sufficient for any of the patients; in one-third of patients, additional segments were required (<3), and in two-thirds of patients, additional beams (<2) were required. Logistic regression analyses revealed central breast diameter (CD) and central lung distance as independent predictors for transition from additional segments to additional beams, with a CD cut-off point at 23.6 cm. Conclusions: Treatment plans fulfilling strict dose homogeneity criteria and normal tissue constraints could be obtained for all patients by stepwise dose intensity modification using limited numbers of segments and additional beams. In patients with a CD of >23.6 cm, additional beams were always required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Esophageal Cancer Dose Escalation Using a Simultaneous Integrated Boost Technique

Purpose: We previously showed that 75% of radiation therapy (RT) failures in patients with unresectable esophageal cancer are in the gross tumor volume (GTV). We performed a planning study to evaluate if a simultaneous integrated boost (SIB) technique could selectively deliver a boost dose of radiation to the GTV in patients with esophageal cancer. Methods and Materials: Treatment plans were generated using four different approaches (two-dimensional conformal radiotherapy [2D-CRT] to 50.4 Gy, 2D-CRT to 64.8 Gy, intensity-modulated RT [IMRT] to 50.4 Gy, and SIB-IMRT to 64.8 Gy) and optimized for 10 patients with distal esophageal cancer. All plans were constructed to deliver the target dose in 28 fractions using heterogeneity corrections. Isodose distributions were evaluated for target coverage and normal tissue exposure. Results: The 50.4 Gy IMRT plan was associated with significant reductions in mean cardiac, pulmonary, and hepatic doses relative to the 50.4 Gy 2D-CRT plan. The 64.8 Gy SIB-IMRT plan produced a 28% increase in GTV dose and comparable normal tissue doses as the 50.4 Gy IMRT plan; compared with the 50.4 Gy 2D-CRT plan, the 64.8 Gy SIB-IMRT produced significant dose reductions to all critical structures (heart, lung, liver, and spinal cord). Conclusions: The use of SIB-IMRT allowed us to selectively increase the dose to the GTV, the area at highest risk of failure, while simultaneously reducing the dose to the normal heart, lung, and liver. Clinical implications warrant systematic evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Planning of Tangential Breast Intensity-Modulated Radiotherapy Using Heuristic Optimization

Purpose: To present an automated technique for two-field tangential breast intensity-modulated radiotherapy (IMRT) treatment planning. Method and Materials: A total of 158 planned patients with Stage 0, I, and II breast cancer treated using whole-breast IMRT were retrospectively replanned using automated treatment planning tools. The tools developed are integrated into the existing clinical treatment planning system (Pinnacle{sup 3}) and are designed to perform the manual volume delineation, beam placement, and IMRT treatment planning steps carried out by the treatment planning radiation therapist. The automated algorithm, using only the radio-opaque markers placed at CT simulation as inputs, optimizes the tangential beam parameters to geometrically minimize the amount of lung and heart treated while covering the whole-breast volume. The IMRT parameters are optimized according to the automatically delineated whole-breast volume. Results: The mean time to generate a complete treatment plan was 6 min, 50 s {+-} 1 min 12 s. For the automated plans, 157 of 158 plans (99%) were deemed clinically acceptable, and 138 of 158 plans (87%) were deemed clinically improved or equal to the corresponding clinical plan when reviewed in a randomized, double-blinded study by one experienced breast radiation oncologist. In addition, overall the automated plans were dosimetrically equivalent to the clinical plans when scored for target coverage and lung and heart doses. Conclusion: We have developed robust and efficient automated tools for fully inversed planned tangential breast IMRT planning that can be readily integrated into clinical practice. The tools produce clinically acceptable plans using only the common anatomic landmarks from the CT simulation process as an input. We anticipate the tools will improve patient access to high-quality IMRT treatment by simplifying the planning process and will reduce the effort and cost of incorporating more advanced planning into clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometric and Dosimetric Approach to Determine Probability of Late Cardiac Mortality in Left Tangential Breast Irradiation: Comparison Between Wedged Beams and Field-in-Field Technique

Purpose: To evaluate the probability of late cardiac mortality resulting from left breast irradiation planned with tangential fields and to compare this probability between the wedged beam and field-in-field (FIF) techniques and to investigate whether some geometric/dosimetric indicators can be determined to estimate the cardiac mortality probability before treatment begins. Methods and Materials: For 30 patients, differential dose-volume histograms were calculated for the wedged beam and FIF plans, and the corresponding cardiac mortality probabilities were determined using the relative seriality model. As a comparative index of the dose distribution uniformity, the planning target volume (PTV) percentages involved in 97-103% of prescribed dose were determined for the two techniques. Three geometric parameters were measured for each patient: the maximal length, indicates how much the heart contours were displaced toward the PTV, the angle subtended at the center of the computed tomography slice by the PTV contour, and the thorax width/thickness ratio. Results: Evaluating the differential dose-volume histograms showed that the gain in uniformity between the two techniques was about 1.5. With the FIF technique, the mean dose sparing for the heart, the left anterior descending coronary artery, and the lung was 15% (2.5 Gy vs. 2.2 Gy), 21% (11.3 Gy vs. 9.0 Gy), and 42% (8.0 Gy vs. 4.6 Gy) respectively, compared with the wedged beam technique. Also, the cardiac mortality probability decreased by 40% (from 0.9% to 0.5%). Three geometric parameters, the maximal length, angle subtended at the center of the computed tomography slice by the PTV contour, and thorax width/thickness ratio, were the determining factors (p = .06 for FIF, and p = .10 for wedged beam) for evaluating the cardiac mortality probability. Conclusion: The FIF technique seemed to yield a lower cardiac mortality probability than the conventional wedged beam technique. However, although our study demonstrated that FIF technique improved the dose coverage of the PTV, the restricted number of patients enrolled and the short follow-up did not allow us to evaluate and compare the breast cancer survival rates of the patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Developing Cardiovascular Disease After Involved Node Radiotherapy Versus Mantle Field for Hodgkin Lymphoma

Purpose: Hodgkin lymphoma (HL) survivors are known to have increased cardiac mortality and morbidity. The risk of developing cardiovascular disease after involved node radiotherapy (INRT) is currently unresolved, inasmuch as present clinical data are derived from patients treated with the outdated mantle field (MF) technique. Methods and Materials: We included all adolescents and young adults with supradiaphragmatic, clinical Stage I-II HL treated at our institution from 2006 to 2010 (29 patients). All patients were treated with chemotherapy and INRT to 30 to 36 Gy. We then simulated a MF plan for each patient with a prescribed dose of 36 Gy. A logistic dose-response curve for the 25-year absolute excess risk of cardiovascular disease was derived and applied to each patient using the individual dose-volume histograms. Results: The mean doses to the heart, four heart valves, and coronary arteries were significantly lower for INRT than for MF treatment. However, the range in doses with INRT treatment was substantial, and for a subgroup of patients, with lymphoma below the fourth thoracic vertebrae, we estimated a 25-year absolute excess risk of any cardiac event of as much as 5.1%. Conclusions: Our study demonstrates a potential for individualizing treatment by selecting the patients for whom INRT provides sufficient cardiac protection for current technology; and a subgroup of patients, who still receive high cardiac doses, who would benefit from more advanced radiation technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Cardiac Impairment Associated With Concurrent Chemoradiotherapy for Esophageal Cancer: Magnetic Resonance Evaluation

Purpose: To evaluate acute cardiac effects of concurrent chemoradiotherapy (CCRT) for esophageal cancer. Methods and Materials: This prospective study was approved by the institutional review board, and written informed consent was obtained from all participants. The left ventricular function (LVF) of 31 patients with esophageal cancer who received cisplatin and 5-fluorouracil-based CCRT was evaluated using cardiac cine magnetic resonance imaging. The patients were classified into two groups according to mean LV dose. The parameters related to LVF were compared between before and during (40 Gy) or between before and after CCRT using a Wilcoxon matched-pairs single rank test, and parameter ratios (during/before CCRT, after/before CCRT) were also compared between the groups with a t test. Data were expressed as mean {+-} SE. Results: In the low LV-dose group (n = 10; mean LV dose <0.6 Gy), LV ejection fraction decreased significantly (before vs. during vs. after CCRT; 62.7% {+-} 2.98% vs. 59.8% {+-} 2.56% vs. 60.6% {+-} 3.89%; p < 0.05). In the high LV-dose group (n = 21; mean LV dose of 3.6-41.2 Gy), LV end-diastolic volume index (before vs. after CCRT; 69.1 {+-} 2.93 vs. 57.0 {+-} 3.23 mL/m{sup 2}), LV stroke volume index (38.6 {+-} 1.56 vs. 29.9 {+-} 1.60 mL/m{sup 2}), and LV ejection fraction (56.9% {+-} 1.79% vs. 52.8% {+-} 1.15%) decreased significantly (p < 0.05) after CCRT. Heart rate increased significantly (before vs. during vs. after CCRT; 66.8 {+-} 3.05 vs. 72.4 {+-} 4.04 vs. 85.4 {+-} 3.75 beats per minute, p < 0.01). Left ventricle wall motion decreased significantly (p < 0.05) in segments 8 (before vs. during vs. after CCRT; 6.64 {+-} 0.54 vs. 4.78 {+-} 0.43 vs. 4.79 {+-} 0.50 mm), 9 (6.88 {+-} 0.45 vs. 5.04 {+-} 0.38 vs. 5.27 {+-} 0.47 mm), and 10 (9.22 {+-} 0.48 vs. 8.08 {+-} 0.34 vs. 8.19 {+-} 0.56 mm). The parameter ratios of LV end-diastolic volume index, stroke volume index, wall motion in segment 9, and heart rate showed significant difference (p < 0.05) after CCRT between the groups. Conclusions: Concurrent chemoradiotherapy for esophageal cancer impairs LVF from an early treatment stage. This impairment is prominent in patients with high LV dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulation Arc Radiotherapy With Flattening Filter-Free Beams Compared With Static Gantry IMRT and 3D Conformal Radiotherapy for Advanced Esophageal Cancer: A Feasibility Study

Purpose: A feasibility study was performed to evaluate RapidArc (RA), and the potential benefit of flattening filter-free beams, on advanced esophageal cancer against intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT). Methods and Materials: The plans for 3D-CRT and IMRT with three to seven and five to seven fixed beams were compared against double-modulated arcs with avoidance sectors to spare the lungs for 10 patients. All plans were optimized for 6-MV photon beams. The RA plans were studied for conventional and flattening filter-free (FFF) beams. The objectives for the planning target volume were the volume receiving {>=}95% or at most 107% of the prescribed dose of <1% with a dose prescription of 59.4 Gy. For the organs at risk, the lung volume (minus the planning target volume) receiving {>=}5 Gy was <60%, that receiving 20 Gy was <20%-30%, and the mean lung dose was <15.0 Gy. The heart volume receiving 45 Gy was <20%, volume receiving 30 Gy was <50%. The spinal dose received by 1% was <45 Gy. The technical delivery parameters for RA were assessed to compare the normal and FFF beam characteristics. Results: RA and IMRT provided equivalent coverage and homogeneity, slightly superior to 3D-CRT. The conformity index was 1.2 {+-} 0.1 for RA and IMRT and 1.5 {+-} 0.2 for 3D-CRT. The mean lung dose was 12.2 {+-} 4.5 for IMRT, 11.3 {+-} 4.6 for RA, and 10.8 {+-} 4.4 for RA with FFF beams, 18.2 {+-} 8.5 for 3D-CRT. The percentage of volume receiving {>=}20 Gy ranged from 23.6% {+-} 9.1% to 21.1% {+-} 9.7% for IMRT and RA (FFF beams) and 39.2% {+-} 17.0% for 3D-CRT. The heart and spine objectives were met by all techniques. The monitor units for IMRT and RA were 457 {+-} 139, 322 {+-} 20, and 387 {+-} 40, respectively. RA with FFF beams showed, compared with RA with normal beams, a {approx}20% increase in monitor units per Gray, a 90% increase in the average dose rate, and 20% reduction in beam on time (owing to different gantry speeds). Conclusion: RA demonstrated, compared with conventional IMRT, a similar target coverage and some better dose sparing to the organs at risk; the advantage against conventional 3D-CRT was more evident. RA with FFF beams resulted in minor improvements in plan quality but with the potential for additional useful reduction in the treatment time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Dose Response for Circulatory Disease After Radiotherapy for Benign Disease

Purpose: To assess the shape of the dose-response for various circulatory disease endpoints, and modifiers by age and time since exposure. Methods and Materials: This was an analysis of the US peptic ulcer data testing for heterogeneity of radiogenic risk by circulatory disease endpoint (ischemic heart, cerebrovascular, other circulatory disease). Results: There were significant excess risks for all circulatory disease, with an excess relative risk Gy{sup -1} of 0.082 (95% CI 0.031-0.140), and ischemic heart disease, with an excess relative risk Gy{sup -1} of 0.102 (95% CI 0.039-0.174) (both p = 0.01), and indications of excess risk for stroke. There were no statistically significant (p > 0.2) differences between risks by endpoint, and few indications of curvature in the dose-response. There were significant (p < 0.001) modifications of relative risk by time since exposure, the magnitude of which did not vary between endpoints (p > 0.2). Risk modifications were similar if analysis was restricted to patients receiving radiation, although the relative risks were slightly larger and the risk of stroke failed to be significant. The slopes of the dose-response were generally consistent with those observed in the Japanese atomic bomb survivors and in occupationally and medically exposed groups. Conclusions: There were excess risks for a variety of circulatory diseases in this dataset, with significant modification of risk by time since exposure. The consistency of the dose-response slopes with those observed in radiotherapeutically treated groups at much higher dose, as well as in lower dose-exposed cohorts such as the Japanese atomic bomb survivors and nuclear workers, implies that there may be little sparing effect of fractionation of dose or low-dose-rate exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variation in Telangiectasia Predisposing Genes Is Associated With Overall Radiation Toxicity

Purpose: In patients receiving radiotherapy for breast cancer where the heart is within the radiation field, cutaneous telangiectasiae could be a marker of potential radiation-induced heart disease. We hypothesized that single nucleotide polymorphisms (SNPs) in genes known to cause heritable telangiectasia-associated disorders could predispose to such late, normal tissue vascular damage. Methods and Materials: The relationship between cutaneous telangiectasia as a late normal tissue radiation injury phenotype in 633 breast cancer patients treated with radiotherapy was examined. Patients were clinically assessed for the presence of cutaneous telangiectasia and genotyped at nine SNPs in three candidate genes. Candidate SNPs were within the endoglin (ENG) and activin A receptor, type II-like 1 (ACVRL1) genes, mutations in which cause hereditary hemorrhagic telangiectasia and the ataxia-telangiectasia mutated (ATM) gene associated with ataxia-telangiectasia. Results: A total of 121 (19.1%) patients exhibited a degree of cutaneous telangiectasiae on clinical examination. Regression was used to examine the associations between the presence of telangiectasiae in patients who underwent breast-conserving surgery, controlling for the effects of boost and known brassiere size (n=388), and individual geno- or haplotypes. Inheritance of ACVRL1 SNPs marginally contributed to the risk of cutaneous telangiectasiae. Haplotypic analysis revealed a stronger association between inheritance of a ATM haplotype and the presence of cutaneous telangiectasiae, fibrosis and overall toxicity. No significant association was observed between telangiectasiae and the coinheritance of the candidate ENG SNPs. Conclusions: Genetic variation in the ATM gene influences reaction to radiotherapy through both vascular damage and increased fibrosis. The predisposing variation in the ATM gene will need to be better defined to optimize it as a predictive marker for assessing radiotherapy late effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Planning Hybrid Intensity Modulated Radiation Therapy for Whole-breast Irradiation

Purpose: To test tangential and not-tangential hybrid intensity modulated radiation therapy (IMRT) for whole-breast irradiation. Methods and Materials: Seventy-eight (36 right-, 42 left-) breast patients were randomly selected. Hybrid IMRT was performed by direct aperture optimization. A semiautomated method for planning hybrid IMRT was implemented using Pinnacle scripts. A plan optimization volume (POV), defined as the portion of the planning target volume covered by the open beams, was used as the target objective during inverse planning. Treatment goals were to prescribe a minimum dose of 47.5 Gy to greater than 90% of the POV and to minimize the POV and/or normal tissue receiving a dose greater than 107%. When treatment goals were not achieved by using a 4-field technique (2 conventional open plus 2 IMRT tangents), a 6-field technique was applied, adding 2 non tangential (anterior-oblique) IMRT beams. Results: Using scripts, manual procedures were minimized (choice of optimal beam angle, setting monitor units for open tangentials, and POV definition). Treatment goals were achieved by using the 4-field technique in 61 of 78 (78%) patients. The 6-field technique was applied in the remaining 17 of 78 (22%) patients, allowing for significantly better achievement of goals, at the expense of an increase of low-dose ({approx}5 Gy) distribution in the contralateral tissue, heart, and lungs but with no significant increase of higher doses ({approx}20 Gy) in heart and lungs. The mean monitor unit contribution to IMRT beams was significantly greater (18.7% vs 9.9%) in the group of patients who required 6-field procedure. Conclusions: Because hybrid IMRT can be performed semiautomatically, it can be planned for a large number of patients with little impact on human or departmental resources, promoting it as the standard practice for whole-breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cardiovascular Comorbidity and Mortality in Men With Prostate Cancer Treated With Brachytherapy-Based Radiation With or Without Hormonal Therapy

Purpose: To assess the impact of coronary artery disease (CAD) risk factors and sequelae on the risk of all-cause mortality (ACM) in men treated for prostate cancer (PC). Methods and Materials: The study cohort comprised 5077 men with PC consecutively treated with curative intent between 1997 and 2006 at the Chicago Prostate Cancer Center. Cox and Fine and Gray's competing risks regression multivariable analyses were performed, assessing whether cardiovascular comorbidity impacted the risk of ACM and PC-specific mortality, respectively, adjusting for CAD risk factors (diabetes mellitus, hypercholesterolemia, or hypertension) and sequelae (congestive heart failure or myocardial infarction), age, year and type of treatment, and known PC prognostic factors. Results: When compared with men with no comorbidity there was a significantly increased risk of ACM in men with congestive heart failure or myocardial infarction (adjusted hazard ratio [AHR] 1.96, P<.001) and in men with diabetes mellitus (AHR 1.60, P=.03) and hypertension (AHR 1.25, P=.04). In contrast, men with hypercholesterolemia had a similar risk of ACM (AHR 0.68, P=.17) when compared with men with no comorbidity. Other factors associated with a significantly increased risk of ACM included age (AHR 1.09, P<.001), prostate-specific antigen level (AHR 1.25, P=.008), and Gleason score 8-10 disease (AHR 1.71, P=.003). Cardiovascular comorbidity did not impact the risk of PC-specific mortality. Conclusions: In addition to age and unfavorable PC prognostic factors, select CAD risk factors and sequelae are associated with an increased risk of ACM in men treated for PC. These comorbidity prognostic factors predict time courses of mortality from competing causes, which may be factored into the decision-making process when considering management options for PC in a given individual.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung Tumors

Purpose: To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. Methods and Materials: This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were replanned using volumetric modulated arc therapy and 4π plans, in which a column generation method was used to optimize the beam orientation and the fluence map. Maximum doses to the heart, esophagus, trachea/bronchus, and spinal cord, as well as the 50% isodose volume, the lung volumes receiving 20, 10, and 5 Gy were minimized and compared against the clinical plans. A dose escalation study was performed to determine whether a higher prescription dose to the tumor would be achievable using 4π without violating dose limits set by the clinical plans. The deliverability of 4π plans was preliminarily tested. Results: Using 4π plans, the maximum heart, esophagus, trachea, bronchus and spinal cord doses were reduced by 32%, 72%, 37%, 44%, and 53% (P≤.001), respectively, and R{sub 50} was reduced by more than 50%. Lung V{sub 20}, V{sub 10}, and V{sub 5} were reduced by 64%, 53%, and 32% (P≤.001), respectively. The improved sparing of organs at risk was achieved while also improving planning target volume (PTV) coverage. The minimal PTV doses were increased by the 4π plans by 12% (P=.002). Consequently, escalated PTV doses of 68 to 70 Gy were achieved in all patients. Conclusions: We have shown that there is a large potential for plan quality improvement and dose escalation for patients with larger or centrally located lung tumors using noncoplanar beams with sufficient quality and quantity. Compared against the clinical volumetric modulated arc therapy and static intensity modulated radiation therapy plans, the 4π plans yielded significantly and consistently improved tumor coverage and critical organ sparing. Given the known challenges in central structure dose constraints in stereotactic body radiation therapy to the lung, 4π planning may increase efficacy and reduce toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiation Therapy for Re-irradiation of Persistent or Recurrent Non-Small Cell Lung Cancer

Purpose: To retrospectively assess toxicity and outcome of re-irradiation with stereotactic body radiation therapy (SBRT) in patients with recurrent or persistent non-small cell lung cancer (NSCLC), who were previously treated with radical radiation therapy (50-60 Gy). The secondary endpoint was to investigate whether there are dosimetric parameter predictors of severe radiation toxicity. Methods and Materials: The analysis was conducted in 17 patients with “in-field” recurrent/persistent centrally located NSCLC, who underwent re-irradiation with SBRT. SBRT consisted of 30 Gy in 5 to 6 fractions; these prescriptions would be equivalent for the tumor to 37.5 to 40 Gy, bringing the total 2-Gy-per-fraction cumulative dose to 87 to 100 Gy, considering the primary radiation therapy treatment. Actuarial analyses and survival were calculated by the Kaplan-Meier method, and P values were estimated by the log-rank test, starting from the date of completion of SBRT. Dosimetric parameters from the subgroups with and without grade ≥3 pulmonary toxicity were compared using a 2-tailed Student t test. Results: The median follow-up was 18 months (range, 4-57 months). Only 2 patients had local failure, corresponding to a local control rate of 86% at 1 year. The Kaplan-Meier estimates of overall survival (OS) rates at 1 and 2 years were 59% and 29%, respectively; the median OS was 19 months. Four patients (23%) experienced grade 3 radiation pneumonitis, and 1 patient developed fatal pneumonitis. One patient died of fatal hemoptysis 2 months after the completion of SBRT. Unexpectedly, heart maximum dose, D5 (minimum dose to at least 5% of the heart volume), and D10 were correlated with risk of radiation pneumonitis (P<.05). Conclusions: Re-irradiation with SBRT for recurrent/persistent centrally located NSCLC achieves excellent results in terms of local control. However, the high rate of severe toxicity reported in our study is of concern.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Control and Toxicity in a Large Cohort of Central Lung Tumors Treated With Stereotactic Body Radiation Therapy

Purpose: Stereotactic body radiation therapy (SBRT) in central lung tumors has been associated with higher rates of severe toxicity. We sought to evaluate toxicity and local control in a large cohort and to identify predictive dosimetric parameters. Methods and Materials: We identified patients who received SBRT for central tumors according to either of 2 definitions. Local failure (LF) was estimated using a competing risks model, and multivariate analysis (MVA) was used to assess factors associated with LF. We reviewed patient toxicity and applied Cox proportional hazard analysis and log-rank tests to assess whether dose-volume metrics of normal structures correlated with pulmonary toxicity. Results: One hundred twenty-five patients received SBRT for non-small cell lung cancer (n=103) or metastatic lesions (n=22), using intensity modulated radiation therapy. The most common dose was 45 Gy in 5 fractions. Median follow-up was 17.4 months. Incidence of toxicity ≥ grade 3 was 8.0%, including 5.6% pulmonary toxicity. Sixteen patients (12.8%) experienced esophageal toxicity ≥ grade 2, including 50% of patients in whom PTV overlapped the esophagus. There were 2 treatment-related deaths. Among patients receiving biologically effective dose (BED) ≥80 Gy (n=108), 2-year LF was 21%. On MVA, gross tumor volume (GTV) was significantly associated with LF. None of the studied dose-volume metrics of the lungs, heart, proximal bronchial tree (PBT), or 2 cm expansion of the PBT (“no-fly-zone” [NFZ]) correlated with pulmonary toxicity ≥grade 2. There were no differences in pulmonary toxicity between central tumors located inside the NFZ and those outside the NFZ but with planning target volume (PTV) intersecting the mediastinum. Conclusions: Using moderate doses, SBRT for central lung tumors achieves acceptable local control with low rates of severe toxicity. Dosimetric analysis showed no significant correlation between dose to the lungs, heart, or NFZ and severe pulmonary toxicity. Esophageal toxicity may be an underappreciated risk, particularly when PTV overlaps the esophagus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗