Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Search for Suitable ICRF Operation Window for the Shaped H-mode Operation of KSTAR

KSTAR will try to achieve its 1st shaped H-mode plasma in 2010 campaign. The available power is limited by our plan for auxiliary heating system. Up to 2010, NBI with 1 MW, LHCD 0.5 MW, and ECH with 0.5 MW power will be prepared. To accomplish high beta plasma, TF magnetic field will be reduced to 2 T from rated field of 3.5 T. In this case the ECH contribution to H-mode power threshold requirement is ignorant because the 84 GHz frequency does not meet neither fundamental nor second harmonic resonance in the discharge area. Therefore the ICRF heating should carry out important roll to reach power threshold. The ICRF system of tunable frequency from 30 to 60 MHz will come with 1 MW power in 2010. To maximize the ICRF heating efficiency for H-mode purpose, we try to find suitable condition of ICRF heating parameters through the simulation using by TORIC code. Optimizations of RF frequency, toroidal modes controllable by 4 current straps, and the minority concentration are performed. Possibilities of second harmonic heating of minority and the mode converted heating near resonance layer are also studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Safety Analyses of Design Basis and Design Extended Condition Events for the PGSFR

KAERI (Korea Atomic Energy Research Institute) has been developing the PGSFR (Prototype Gen-IV Sodium-cooled Fast Reactor), which is a pool type sodium-cooled fast reactor with the thermal power of 392.2 MWt, uses metallic fuel of U-10%Zr for a core. The preliminary specific design of PGSFR is completed in 2015. The main parts of PGSFR consist of PHTS (Primary Heat Transport System), IHTS (Intermediate Heat Transport System), two SG (Steam Generator), and DHRS (Decay Heat Removal System). The main feature of PGSFR in safety is from the adoption of metallic fuel core, leading to inherent reactivity feedback mechanisms and high thermal conductivity. In this work, safety analysis on DBE (Design Basis Event) and DEC (Design Extended Condition event) for PGSFR preliminary specific design is conducted using MARS-LMR code. Conservative and best-estimated approaches are applied to DBA and DEC, respectively. It is found that the most severe accidents in the AOO, DBA class 1, DBA class 2, and DEC are LOF, OPS, TOP and ULOF event, respectively. And all analysis results are found to meet safety acceptance criteria requirements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary analysis of aircraft fuel systems for use with broadened specification jet fuels

An analytical study was conducted on the use of broadened specification hydrocarbon fuels in present day aircraft. A short range Boeing 727 mission and three long range Boeing 747 missions were used as basis of calculation for one-day-per-year extreme values of fuel loading, airport ambient and altitude ambient temperatures with various seasonal and climatic conditions. Four hypothetical fuels were selected; two high-vapor-pressure fuels with 35 kPa and 70 kPa RVP and two high-freezing-point fuels with -29 C and -18 C freezing points. In-flight fuel temperatures were predicted by Boeing's aircraft fuel tank thermal analyzer computer program. Boil-off rates were calculated for the high vapor pressure fuels and heating/insulation requirements for the high freezing point fuels were established. Possible minor and major heating system modifications were investigated with respect to heat output, performance and economic penalties for the high freezing point fuels.

Pasion, A. J.↗

Order-of-magnitude laser imprint reduction using pre-expanded high-Z coatings on targets driven by a third harmonic Nd:glass laser

A hybrid early time x-ray drive followed by conventional laser direct drive obtained by utilizing a thin high-Z overcoat on plastic ablator targets has proven to be very effective at reducing laser imprint in experiments driven by the Nike krypton-fluoride laser. An inherent low level laser prepulse from that laser system heated and expanded the coating prior to the main pulse. Here, we report on results using a frequency tripled Nd:glass laser system (Omega EP) where the inherent prepulse was several orders of magnitude smaller. By applying a separate prepulse, these experiments allowed us to test if the prepulse is important for mitigating imprint with the high-Z layer. The results show that the high-Z coating is much more effective at reducing laser imprint when it is pre-expanded, in this case, by an externally generated low level soft x-ray prepulse of ∼10 J/cm2. With the x-ray prepulse, laser imprint at spatial wavelengths below 100 μm was reduced by an order of magnitude, similar to that observed with the laser prepulse on Nike. Furthermore, the experiments here establish that high-Z coating is effective in reducing imprint even in the case of a fixed speckle pattern. Rayleigh–Taylor-amplified laser imprint and high-Z layer dynamics were measured using through-foil and side-on x-ray radiography. Pre-expansion times from 30 down to 6 ns were effective, potentially compatible with laser prepulse generation using existing NIF and OMEGA front ends; however, temporal beam smoothing appears to be necessary for the laser prepulse that directly illuminates the high-Z coating. The highest imprint reduction is observed for Pd and Au coatings of at least 400 Å thickness; thicknesses down to 200 Å show a reduction in imprint with an adjusted prepulse.

Karasik, Max (ORCID:0000000162354670)↗

Physics through the 1990s: Plasmas and fluids

The volume contains recommendations for programs in, and government support of, plasma and fluid physics. Four broad areas are covered: the physics of fluids, general plasma physics, fusion, and space and astrophysical plasmas. In the first section, the accomplishments of fluid physics and a detailed review of its sub-fields, such as combustion, non-Newtonian fluids, turbulence, aerodynamics, and geophysical fluid dynamics, are described. The general plasma physics section deals with the wide scope of the theoretical concepts involved in plasma research, and with the machines; intense beam systems, collective and laser-driven accelerators, and the associated diagnostics. The section on the fusion plasma research program examines confinement and heating systems, such as Tokamaks, magnetic mirrors, and inertial-confinement systems, and several others. Finally, theory and experiment in space and astrophysical plasma research is detailed, ranging from the laboratory to the solar system and beyond. A glossary is included.

Source record↗

Solar heating and cooling system installed at Leavenworth, Kansas

A solar heating and cooling is described which is designed to furnish 90 percent of the overall heating load, 70 percent of the cooling load and 100 percent of the domestic hot water load. The building has two floors with a total of 12,000 square feet gross area. The system has 120 flat-plate liquid solar panels with a net area of 2,200 square feet. Five 3 ton Arkla solar assisted absorption units provide the cooling, in conjunction with a 3,000 gallon chilled water storage tank. Two 3,000 gallon storage tanks are provided with one designated for summer use, whereas both tanks are utilized during winter.

Source record↗

Open-source simulation platform for air source heat pump integrated with thermal energy storage

Here, this article introduces a modular simulation platform for assessing thermal energy storage (TES) integrated with air source heat pumps (ASHP). The Python platform is an open-source library that includes classes for modeling air-air and air-water heat pumps, TES devices, and the heating load of residential buildings. To validate the ASHP model, the study utilized experimental data obtained from a commercial heat pump evaluated at the National Renewable Energy Laboratory (NREL). The results indicate a mean deviation of 0.7% for COP across the operating range, with a maximum relative deviation of 12.6%. In terms of system heating capacity, the model had an average deviation of 4.3% compared to experimental results, with a maximum deviation of 8.2%. Three classes were implemented for modeling distinct types of TES devices: a generic TES based on energy balances, a sensible isothermal water tank, and a stratified water tank. Details of the mathematical models are provided, along with their respective strengths and limitations. An example is provided showcasing the integration of a residential 10 kWh thermal storage unit with an ASHP operating in Denver, CO. The comparison of two different discharge criteria for the TES unit highlights the importance of control strategies in the system performance.

25 ENERGY STORAGE↗

Prototype solar heating and hot water systems

Two prototype solar heating and hot water systems are reported that of the following subsystems: collector, storage, control, transport, hot water, and auxiliary energy.

Source record↗

Operational domain of Proto-MPEX

The Prototype-Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device to test the plasma source concepts for the future Material Plasma Exposure eXperiment (MPEX). MPEX is planned to address plasma material interactions under fusion reactor divertor conditions as will occur in devices like DEMO, including the plasma exposure of a-priori neutron irradiated materials. This requires a novel linear plasma device with a plasma source that can produce high electron densities along with heating systems to obtain high electron and ion temperatures. In Proto-MPEX a high-power helicon source was tested together with electron heating (28 GHz microwaves) and ion cyclotron heating (8.5-12 MHz). Electron densities in excess of 1 × 1020 m-3 were produced with the helicon antenna. Electron temperatures can reach 20 eV and are typically below 6 eV at high densities (>5 × 1019 m-3). Ion heating has been demonstrated at low electron densities (<2 × 1019 m-3) with ion temperatures of up to 13 eV. Maximum heat fluxes of 14 MW/m2 have been obtained in low density discharges (~5 × 1018 m-3), while heat fluxes are typically only 2–3 MW/m2 in high density discharges (>2 × 1019 m-3).

Rapp, Juergen↗

Technical challenges in the construction of the steady-state stellarator Wendelstein 7-X

The next step in the Wendelstein stellarator line is the large superconducting device Wendelstein 7-X, currently under construction in Greifswald, Germany. Steady-state operation is an intrinsic feature of stellarators, and one key element of the Wendelstein 7-X mission is to demonstrate steady-state operation under plasma conditions relevant for a fusion power plant. Steady-state operation of a fusion device, on the one hand, requires the implementation of special technologies, giving rise to technical challenges during the design, fabrication and assembly of such a device. On the other hand, also the physics development of steady-state operation at high plasma performance poses a challenge and careful preparation. The electron cyclotron resonance heating system, diagnostics, experiment control and data acquisition are prepared for plasma operation lasting 30 min. This requires many new technological approaches for plasma heating and diagnostics as well as new concepts for experiment control and data acquisition.

Bosch, H. -S.↗

Divertor-safe nonlinear burn control based on a SOLPS parameterized core-edge model for ITER

Abstract For ITER operations, the range of desirable burning-plasma regimes with high fusion power output will be restricted by various operational constraints. These constraints include the saturation of ITER’s various heating and fueling actuators such as the neutral beam injectors, the ion and electron cyclotron heating systems, the gas puffing system, and the deuterium–tritium pellet injectors. In addition to these actuator constraints, the H-mode power threshold, divertor detachment, and the heat load on the divertor targets may apply limitations to ITER’s operational space. In this work, Plasma Operation Contour (POPCON) plots that map the aforementioned constraints to the temperature-density space are used to investigate which constraints are most limiting towards accessing regimes with high fusion power output. The presented POPCON plots are based on a control-oriented core-edge model that couples the nonlinear density and energy response models for the core-plasma region with SOLPS4.3 parameterizations for conditions in the edge-plasma regions (scrape-off-layer and divertor). Using this control-oriented core-edge model, a nonlinear burn controller, which aims to regulate the plasma temperature and density in the core-plasma region, is constructed in this work. This controller is augmented with an online optimization scheme that governs the control references such that the plasma can be guided towards regimes with high fusion powers while protecting the divertor targets from dangerously high heat loads. A closed-loop simulation study illustrates the capability of this burn control scheme.

Physics↗

Magellan aerobraking periapse corridor design

One extended mission idea for the Magellan project uses aerobraking techniques to circularize the current orbit. A major technical issue in this proposal is the design of the periapse altitude corridor. Aerobraking would cause a number of significant side effects on both the spacecraft and ground system. Heating and aerodynamic torques on the spacecraft are key issues, as are the corridor control maneuver frequency and aerobrake duration. Spacecraft and ground systems operational limits have been identified in an attempt to constrain the corridor design. A simulation program has been developed to model the aerobraking corridor control process. This paper presents study results using this program which relate to the feasibility of this aerobraking concept.

Cook, Richard A.↗

Existing Whole-House Solutions Case Study: Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts

The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. In this project, Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent).

air barrier↗

Initial operation of a solar heating and cooling system in a full-scale solar building test facility

The Solar Building Test Facility (SBTF) was constructed to advance the technology for heating and cooling of office buildings with solar energy. Its purposes are to (1) test system components which include high-performing collectors, (2) test the performance of a complete solar heating and cooling system, (3) investigate component interactions, and (4) investigate durability, maintenance and reliability of components. The SBTF consists of a 50,000 square foot office building modified to accept solar heated water for operation of an absorption air conditioner and for the baseboard heating system. A 12,666 square foot solar collector field with a 30,000 gallon storage tank provides the solar heated water. A description of the system and the collectors selected is printed along with the objectives, test approach, expected system performance, and some preliminary results.

Knoll, R. H.↗

Solar Thermal Energy Planner (STEP 1): A New Decision Support Tool for Solar Industrial Process Heat Applications

Solar thermal technologies are a promising technology to supply low-cost thermal energy to industrial processes, but there are often significant barriers to entry to industrial owners considering these technologies for their energy demands. To overcome this barrier and convey economic value to customers, NREL and Sandia National Laboratories developed Solar Thermal Energy Planner (STEP 1), a new web-based decision support tool for solar industrial process heat systems. At SolarPACES 2024, the STEP 1 tool was still under development; progress, methodologies, and a preliminary case study was presented. With the STEP 1 tool launch in May 2025, in this work, the initial version of the full public tool will be presented with demonstrations of its capabilities using a few case studies. First, the user's process heat needs such as location, process media (e.g., steam, air), process temperature, land availability, electricity and fuel costs, among other parameters. STEP 1 features a mapping interface that allows users to draw land and roof boundaries. The process media and temperature inform technology selection criteria modules that determine the appropriate solar thermal collection technologies, as well as congruent heat transfer media (e.g., hot water, oil, salt). Once the solar thermal technology selected, its nominal thermal production for the given site is characterized using NREL's System Advisor Model (SAM). Then, a modified version of NREL's REopt optimal sizing and dispatch optimization tool determines cost-optimal sizing. Within minutes, the user receives the results of the technoeconomics analysis, including the size and performance of the cost-optimal solar-plus-storage system. The cost of the system is compared to business-as-usual (e.g., an existing, standalone natural gas boiler). Users can download key results to store for sensitivity analyses. Examples of flat plate collector, parabolic trough, and molten salt tower applications with and without PV hybridization for different industrial facility types are presented in this work. The STEP 1 tool aims to reduce barriers to the adoption of solar heating solutions stemming from a lack of familiarity and technical background with solar system design options and costs among industry stakeholders.

14 SOLAR ENERGY↗

Coupled fvGCM-GCE Modeling System, TRMM Latent Heating and Cloud Library

Recent GEWEX Cloud System Study (GCSS) model comparison projects have indicated that cloud-resolving models (CRMs) agree with observations better than traditional single-column models in simulating various types of clouds and cloud systems from different geographic locations. Current and future NASA satellite programs can provide cloud, precipitation, aerosol and other data at very fine spatial and temporal scales. It requires a coupled global circulation model (GCM) and cloud-scale model (termed a super-parameterization or multi-scale modeling framework, MMF) to use these satellite data to imiprove the understanding of the physical processes that are responsible for the variation in global and regional climate and hydrological systems. The use of a GCM will enable global coverage, and the use of a CRM will allow for better and more sophisticated physical parameterization. NASA satellite and field campaign cloud related datasets can provide initial conditions as well as validation for both the MMF and CRMs. A seed fund is available at NASA Goddard to build a MMF based on the 2D GCE model and the Goddard finite volume general circulation model (fvGCM). A prototype MMF will be developed by the end of 2004 and production runs will be conducted at the beginning of 2005. The purpose of this proposal is to augment the current Goddard MMF and other cloud modeling activities. I this talk, I will present: (1) A summary of the second Cloud Modeling Workshop took place at NASA Goddard, (2) A summary of the third TRMM Latent Heating Workshop took place at Nara Japan, (3) A brief discussion on the Goddard research plan of using Weather Research Forecast (WRF) model, and (4) A brief discussion on the GCE model on developing a global cloud simulator.

Tao, Wei-Kuo↗

Coupled fvGCM-GCE Modeling System: TRMM Latent Heating and Cloud Library

Recent GEWEX Cloud System Study (GCSS) model comparison projects have indicated that cloud-resolving models (CRMs) agree with observations better than traditional single-column models in simulating various types of clouds and cloud systems from different geographic locations. Current and future NASA satellite programs can provide cloud, precipitation, aerosol and other data at very fine spatial and temporal scales. It requires a coupled global circulation model (GCM) and cloud-scale model (termed a super-parameterization or multi-scale modeling framework, MMF) to use these satellite data to improve the understanding of the physical processes that are responsible for the variation in global and regional climate and hydrological systems. The use of a GCM will enable global coverage, and the use of a CRM will allow for better and more sophisticated physical parameterization. NASA satellite and field campaign cloud related datasets can provide initial conditions as well as validation for both the MMF and CRMs. A seed fund is available at NASA Goddard to build a MMF based on the 2D GCE model and the Goddard finite volume general circulation model (fvGCM). A prototype MMF will be developed by the end of 2004 and production runs will be conducted at the beginning of 2005. The purpose of this proposal is to augment the current Goddard MMF and other cloud modeling activities. In this talk, I will present: (1) A summary of the second Cloud Modeling Workshop took place at NASA Goddard, (2) A summary of the third TRMM Latent Heating Workshop took place at Nara Japan, (3) A brief discussion on the GCE model on developing a global cloud simulator.

Tao, Wei-Kuo↗

Numerical analysis of flow and heat transfer in the VAFB LOX storage Dewar tank

The present report describes numerical simulation of three-dimensional transient distributions of velocity and temperature of liquid oxygen (LOX) in the LOX Dewar tank of Vendenberg Air Force Base (VAFB). The present analyses cover the replenish time period only. Four test cases have been considered. For all four cases, the input boundary conditions are comprised of LOX facility heat loads, drain flow rates, recirculation flow rates and dewar heating. All the quantities are prescribed as functions of time. The first two test cases considered sensitivity of results to the computational grid. In Case 3, system heat load was changed, while in Case 4, a lower LOX level was specified. Cases 1 and 2 showed that the temperatures were not sensitive to the grid refinement. This provided a basic check on the numerical model. Cases 3 and 4 showed that the thermal boundary layer motion near the tank surface becomes more significant at the late time, e.g., 5 1/2 hours from replenish start. Comparison between results of Cases 3 and 4 showed, as expected, that the smaller initial LOX volume given in Case 4, results in higher temperature level. All calculated velocity and temperature distributions were found to be plausible.

Tam, L. T.↗