Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Storage Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Large Destabilization of (TiVNb)-Based Hydrides via (Al, Mo) Addition: Insights from Experiments and Data-Driven Models

High-entropy alloys (HEAs) represent an interesting alloying strategy that can yield exceptional performance properties needed across a variety of technology applications, including hydrogen storage. Examples include ultrahigh volumetric capacity materials (BCC alloys → FCC dihydrides) with improved thermodynamics relative to conventional high-capacity metal hydrides (like MgH 2 ), but still further destabilization is needed to reduce operating temperature and increase system-level capacity. Here, in this work, we demonstrate efficient hydride destabilization strategies by synthesizing two new Al 0.05 (TiVNb) 0.95–x Mo x (x = 0.05, 0.10) compositions. We specifically evaluate the effect of molybdenum (Mo) addition on the phase structure, microstructure, hydrogen absorption, and desorption properties. Both alloys crystallize in a bcc structure with decreasing lattice parameters as the Mo content increases. The alloys can rapidly absorb hydrogen at 25 °C with capacities of 1.78 H/M (2.79 wt %) and 1.79 H/M (2.75 wt %) with increasing Mo content. Pressure-composition isotherms suggest a two-step reaction for hydrogen absorption to a final fcc dihydride phase. The experiments demonstrate that increasing Mo content results in a significant hydride destabilization, which is consistent with predictions from a gradient boosting tree data-driven model for metal hydride thermodynamics. Furthermore, improved desorption properties with increasing Mo content and reversibility were observed by in situ synchrotron X-ray diffraction, in situ neutron diffraction, and thermal desorption spectroscopy.

36 MATERIALS SCIENCE↗

FY 2021 Mid-Year HPC Utilization Report M3UF-21IN0701018

Idaho National Laboratory (INL), supported by the Department of Energy Office of Nuclear Energy (DOE-NE) through the Nuclear Science User Facilities, provides access to supercomputer systems and data storage along with support staff for system management, software installation, cybersecurity and user support to the broader DOE-NE user community. Users include individuals at universities, industry, and government laboratories enabling a wide range of research and development and mission-supporting activities. The availability of high-performance computing (HPC) capabilities is a key foundation of collaboration and innovation in nuclear energy systems research. HPC resources and INL directly support the mission and objectives of DOE-NE. From October 2020 through March 2021, INL HPC capabilities were utilized by a diverse set of computing and applied researchers, for a wide range of research and engineering activities. This report focuses on current INL HPC systems and utilization from October 1, 2020 through March 31, 2021.

99 GENERAL AND MISCELLANEOUS↗

Economically Viable Intermediate to Long Duration Hydrogen Energy Storage Solutions for Fossil Fueled Assets

This report was prepared as an account of work sponsored by the Office of Fossil Energy and Carbon Management of U.S. Department of Energy under Funding Opportunity Announcement Number DE-FOA-0002332 “Energy Storage for Fossil Power Generation”. The work aimed to explore and advance an innovative hydrogen energy storage system – the synergistically integrated hydrogen energy storage system (SIHES) – that has the following characteristics: • Compatible with existing or new coal and gas fuel electricity generation units, • best suited for intermediate to long duration energy storage, from 12 hours to weeks even months, and • capable of storing energy at the utility scale – hundreds of MWh to GWh energy storage with power output level in tens to hundreds of MW. Preliminary front-end engineering design (Pre-FEED) studies was carried out to develop and refine a site-specific SIHES as peaking power generation units (so named as HyPeaker) as the first market entry point, to demonstrate both the technical feasibility and the economic viability to integrate the HyPeaker “within the fence” of a fossil power plant. This specific site was TVA’s Johnsonville Combustion Turbine Plant. The HyPeaker was designed and engineered to integrate with a 60MW aeroderivative gas turbine unit already available at TVA’s Johnsonville site. This site-specific HyPeaker consists of an alkaline electrolyzer to produce hydrogen from CO 2 free electricity sources, an innovative low-cost high-pressure hydrogen storage system (Big-Ton) and the aero gas turbine to generate electricity using blend of hydrogen and natural gas. A holistic system level technoeconomic analysis tool specific to HyPeaker was developed to optimize the engineering design of the Johnsonville site-specific HyPeaker for cost and performance. The optimal design and specification of the Johnsonville site-specific HyPeaker are the following: • Alkaline electrolyzer: 3MW • Big-Ton storage vessel: 11,000kg H 2 at 3000psi. • 4-stage diaphragm hydrogen compressor: 55kg-H 2 /hr from 150psi to 3000psi. The HyPeaker is designed to provide sufficient hydrogen for 90% continuous operation of the HyPeaker. All major components have design life of 30 years. The capex of HyPeaker is estimated at $\$$7.1M. This included $\$$1.5M for the electrolyzer, $\$$5.6M for the storage vessel and compressor. The cost of aero gas turbine was included as it is already available at the site. Key findings are: • HyPeaker can be designed, manufactured, installed and integrated with the fossil power plants, with sub-systems and components commercially available on the market today, even when it is scaled up to an order of magnitude larger than the one at the Johnsonville site. HyPeaker is a technologically viable solution to cover a wide range of energy storage duration needs, from daily peaking operation to seasonal shifting for fossil fueled assets. • The cost advantage of SCCV based Big-Ton H 2 storage vessel made it possible to “oversize” the H 2 storage subsystem to achieve overall system level cost optimization. The benefits are two-fold. First, it allows to significantly reduce the capacity and cost of electrolyzer by spreading H 2 production over a much longer period of time when the fuel cost for electricity production is low. Second, it allows to balance the hydrogen production and usage shift over weeks to months to meet the peak demands. As such, the capital cost of HyPeaker system using the Big-Ton was less than half of the cost of a system with today’s steel tube based H 2 storage system. The HyPeaker has even better cost advantage Li-ion battery based energy storage system. The estimated capital cost of Li-Ion battery system would be at $\$$38M, under the same projected 20-year electricity generation profile of the Johnsonville site. This is over 5 times more expensive than the HyPeaker system. • Since industry scale energy storage systems do not have 100% energy conversion and storage efficiency, energy storage systems using fossil fuel generated electricity would increase the CO 2 emission. This is particularly the case for HyPeaker due to its low round trip efficiency. Therefore, a more sensible solution would be to the excessive or curtailed electricity from CO 2 emission free sources such as solar farms, wind farms or nuclear power plants, to produce hydrogen, and integrate them with the HyPeaker. Electricity from TVA’s nuclear power plants was used for the Johnsonville HyPeaker. • The economic viability of HyPeaker is expected to be further improved when global supply chains are taken into consideration. For the same Johnsonville site specific HyPeaker, the capex would be reduced to ~$\$$3.6M from ~$\$$7.1M, and the added LCOE is reduced to ~$\$$85/MWh. With the bipartisan Infrastructure Investment and Jobs Act, the cost of domestically produced HyPeaker sub-systems would be at the level of today’s global suppliers. Since the peaking units generally operate at peak usage period, thereby demanding higher price, the projected $\$$85/MWh LCOE would be within the realm of financial viability for utility operators.

08 HYDROGEN↗

Metal-Organic Frameworks (MOFs) Containing Frustrated Lewis Pairs (FLP) for H 2 Storage at Ambient Temperature

This final technical report summarizes the key accomplishments of the HyMarc Seedling project to develop new materials based on metal-organic framework (MOF) incorporated with frustrated Lewis pairs (FLP) termed as FLP@MOF, as next-generation of hydrogen storage sorbent that can meet or exceed DOE’s 2025 performance target of hydrogen storage gravimetric density of 5.5 wt.% and volumetric density of 0.040 kg H 2 /L. The project was carried out by the PI Shengqian Ma at the University of North Texas (UNT) along with Argonne National Laboratory (ANL) to develop FLP@MOF systems that exhibit high hydrogen storage capacity at ambient temperature under pressure <100 bar, as well as to obtain improved fundamental understanding of hydrogen adsorption mechanism in FLP@MOF system.

08 HYDROGEN↗

High temperature solar thermal technology

Some advanced technology concepts under development for high-temperature solar thermal energy systems to achieve significant energy cost reductions and performance gains and thus promote the application of solar thermal power technology are presented. Consideration is given to the objectives, current efforts and recent test and analysis results in the development of high-temperature (950-1650 C) ceramic receivers, thermal storage module checker stoves, and the use of reversible chemical reactions to transport collected solar energy. It is pointed out that the analysis and testing of such components will accelerate the commercial deployment of solar energy.

Leibowitz, L. P.↗

Using temperature and flow fields to detect gas leakage from canisters containing spent nuclear fuel: Applications to RAMM-TM

The multi-physics STAR-CCM+ code has been used to simulate the temperature and flow fields in canister gas leakage experiments conducted by using a 1/4.5-scale model storage cask. The simulations were conducted at Argonne National Laboratory’s Laboratory Computing Resource Center, utilizing high-performance computing resources. Development of STAR-CCM+ simulation models for the 1/4.5-scale model cask is described herein, followed by validation of the simulation results against experimental data. Canister depressurization and thermal response during gas leakage are discussed, along with analyses of the leakage path and allowable leakage rate. The insights gained from the STAR-CCM+ simulations and leakage analyses will help guide future experiments and actual industry applications of Argonne’s Remote Area Modular Monitoring system for canister surface temperature measurement (RAMM-TM) to enable effective aging management of spent fuel during extended dry storage, as well as help reduce risks to public safety and health and protect the environment.

Canister gas leakage↗

Offshore Wind Farm Turbine and Energy Storage Optimization

Abstract This paper evaluates the technical and economic feasibility of repurposing decommissioned offshore oil and gas platforms as electrical substations for offshore wind projects in the U.S. Gulf of America, a region characterized by relatively low and highly variable wind speeds, extensive legacy offshore infrastructure, and exposure to merchant electricity markets. A unified techno-economic framework is developed using the Repurposing Offshore Infrastructure for Continued Energy (ROICE) Economic Model (REM) to integrate Gulfspecific wind resource assessment, commercial wind turbine performance, offshore infrastructure cost modeling, and wholesale electricity market exposure. Gulf wind speed data are vertically extrapolated to turbine hub height and combined with manufacturer power curves to compute annual energy production and capacity factors across a broad portfolio of commercial turbines, enabling identification of turbine designs best suited for low-wind offshore environments. Hourly electricity price data from the Midcontinent Independent System Operator (MISO) day-ahead market are incorporated to characterize revenue potential, price volatility, and the temporal alignment between wind generation and market conditions. In addition, a conceptual framework for offshore battery energy storage system (BESS) integration is developed to support future investigation of market-responsive energy shifting at repurposed platforms. Results from the turbine evaluation demonstrate that machines with lower cut-in wind speeds and earlier ‘rated-power’ characteristics significantly outperform larger, industry-standard offshore turbines for the same net power under Gulf wind conditions, underscoring the need for region-specific technology selection. Market analysis further reveals substantial price variability and limited intrinsic alignment between wind production and high-price periods, motivating consideration of operational flexibility mechanisms. While storage optimization is not implemented in this study, the REM framework establishes a transparent and replicable foundation for co-evaluating turbine selection, infrastructure constraints, and market exposure, providing a practical pathway for assessing the potential role of repurposed offshore platforms in enabling economically viable offshore wind development in the Gulf of America.

02 PETROLEUM↗

High Performance Computing Peak Shaving for Microreactor Operation

There are multiple nuclear microreactors currently under development that are designed to provide autonomous power for as many as ten or more years without refueling and are designed to power high performance computing (HPC) datacenters. But the load-follow speeds for a nuclear microreactor will be much slower than grid power and slower than the power variance typical of a HPC system. HPC datacenters experience peak power load variance driven by several factors ranging from the operation of cooling systems to remove heat from the servers to supporting a wide range of user application workflows and architectures each with different power signatures. One mechanism to support the limited load-follow of a microreactor is peak shaving where an energy storage mechanism is used to shed peak load and reduce significant power variance. This work explores peak electrical load shaving using uninterruptible power supply (UPS) systems designed for HPC support in the context of peak shaving when operating using a nuclear microreactor with a load-follow limited to 10% of load per minute. Using a self contained HPC datacenter complete with stand-alone cooling system and provisioned with an x86 cluster, an ARM cluster, and a graphics processing unit (GPU) cluster, peak shaving for microreactor operation using the UPS battery backup is explored while running two classes of typical HPC user applications. HPC architecture suitability for microreactor operation under this type of peak shaving is examined.

97 MATHEMATICS AND COMPUTING↗

Advanced battery modeling for interfacial phenomena and optimal charging

Lithium ion batteries are one of the most promising energy storage systems for portable devices, transportation, and renewable grids. To meet the increasing requirements of these applications, higher energy density and areal capacity, long cycle life, fast charging rate and enhanced safety for lithium ion battery (LIBs) are urgently needed. To solve these challenges, the relevant physics at different length scale need to be understood. However, experimental study is time consuming and limited in small scale’s study. Modeling techniques provide us powerful tools to get a deep understanding of the relevant physics and find optimal solutions. This work focuses on studying the mechanism in advanced battery engineering techniques and developing a new charging algorithm by model-based optimization. The research topics are divided into six topics and each topic is reported as a form of journal publication. Paper Ⅰ provides a new aspect of how ALD coating improves the lithium ion diffusion at electrode particles. Paper Ⅱ explains the mechanisms by which 3D electrodes enhance battery performance and reveals guidelines for optimized 3D electrode designs by a 3D electrochemical-mechanical battery model. Paper Ⅲ investigates the electrolyte concentration impact on SEI layer growth and Li plating, especially under high charge rates. Paper Ⅳ proposes an optimized charging protocol for fast charging for reducing the charging time with minimal degradation. Paper Ⅴ reports a comprehensive degradation model for degradation estimation and life predication of energy storage system (ESS). Paper Ⅵ is a study of temperature-dependent state of charge (SOC) estimation for battery pack.

25 ENERGY STORAGE↗

Screening of alkali-assisted storage conditions to define the operational window of deacetylation within storage systems in the bioenergy supply chain

Overcoming biomass heterogeneity and associated recalcitrance to thermal, chemical, and enzymatic depolymerization is a necessary but challenging aspect of valorizing lignocellulosic biomass to fuels and chemicals. Here, this study explores how this recalcitrance can be reduced during the supply chain unit operation of storage, which is required for seasonally harvested agricultural residues to maintain constant throughput at a biorefinery. In this work, partial alkali pretreatment was performed just prior to corn stover entering storage, which had the benefit of providing a high pH environment entering storage such that soluble sugars were preserved and saponified acetyl groups in hemicellulose. This work investigated a range of viable conditions where saponification and preservation occur simultaneously by varying the moisture content (40% and 60%) and concentrations of sodium hydroxide (low and high) during aerobic and anaerobic storage. Anaerobic conditions preserved overall dry matter below 5% in the three scenarios evaluated, and the highest alkali loading solubilized up to 15% lignin, 18% xylan, and 50% of acetate, meanwhile doubling the extractable components. Scanning electron microscopy images highlighted potential physical impacts including cell-wall disruption near vascular bundles, pitting within parenchyma cells, and cell-wall distortion. Techno-economic assessment indicated that this storage approach and associated logistics system is economically competitive with a conventional approach using low-moisture bales.

09 BIOMASS FUELS↗

Overlapped checkpointing with hardware assist

We present a new approach to handling the demanding I/O workload incurred during checkpoint writes encountered in High Performance Computing. Prior efforts to improve performance have been primarily bound by mechanical limitations of the hard drive. Our research surpasses this limitation by providing a method to: (1) write checkpoint data to a high-speed, non-volatile buffer, and (2) asynchronously write this data to permanent storage while resuming computation. This removes the hard drive from the critical data path because our I/O node based buffers isolate the compute nodes from the storage servers. This solution is feasible because of industry declines in cost for high-capacity, non-volatile storage technologies. Testing was conducted on a small-scale cluster to prove the design, and then scaled at Los Alamos National Laboratory. Results show a definitive speedup factor for select workloads over writing directly to a typical global parallel file system; the Panasas ActiveScale File System.

97 MATHEMATICS AND COMPUTING↗

Virtualization - A Key Cost Saver in NASA Multi-Mission Ground System Architecture

With science team budgets being slashed, and a lack of adequate facilities for science payload teams to operate their instruments, there is a strong need for innovative new ground systems that are able to provide necessary levels of capability processing power, system availability and redundancy while maintaining a small footprint in terms of physical space, power utilization and cooling.The ground system architecture being presented is based off of heritage from several other projects currently in development or operations at Goddard, but was designed and built specifically to meet the needs of the Science and Planetary Operations Control Center (SPOCC) as a low-cost payload command, control, planning and analysis operations center. However, this SPOCC architecture was designed to be generic enough to be re-used partially or in whole by other labs and missions (since its inception that has already happened in several cases!)The SPOCC architecture leverages a highly available VMware-based virtualization cluster with shared SAS Direct-Attached Storage (DAS) to provide an extremely high-performing, low-power-utilization and small-footprint compute environment that provides Virtual Machine resources shared among the various tenant missions in the SPOCC. The storage is also expandable, allowing future missions to chain up to 7 additional 2U chassis of storage at an extremely competitive cost if they require additional archive or virtual machine storage space.The software architecture provides a fully-redundant GMSEC-based message bus architecture based on the ActiveMQ middleware to track all health and safety status within the SPOCC ground system. All virtual machines utilize the GMSEC system agents to report system host health over the GMSEC bus, and spacecraft payload health is monitored using the Hammers Integrated Test and Operations System (ITOS) Galaxy Telemetry and Command (TC) system, which performs near-real-time limit checking and data processing on the downlinked data stream and injects messages into the GMSEC bus that are monitored to automatically page the on-call operator or Systems Administrator (SA) when an off-nominal condition is detected. This architecture, like the LTSP thin clients, are shared across all tenant missions.Other required IT security controls are implemented at the ground system level, including physical access controls, logical system-level authentication authorization management, auditing and reporting, network management and a NIST 800-53 FISMA-Moderate IT Security plan Risk Assessment Contingency Plan, helping multiple missions share the cost of compliance with agency-mandated directives.The SPOCC architecture provides science payload control centers and backup mission operations centers with a cost-effective, standardized approach to virtualizing and monitoring resources that were traditionally multiple racks full of physical machines. The increased agility in deploying new virtual systems and thin client workstations can provide significant savings in personnel costs for maintaining the ground system. The cost savings in procurement, power, rack footprint and cooling as well as the shared multi-mission design greatly reduces upfront cost for missions moving into the facility. Overall, the authors hope that this architecture will become a model for how future NASA operations centers are constructed!

Ground System Architecture↗

Innovative Approach to SCC Inspection and Evaluation of Canister in Dry Storage

This final report is summarized four years of work of awarded project number DE-NE0008442\IRP-15-9318, title as: “Innovative Approach to SCC Inspection and Evaluation of Canister in Dry” supported by Nuclear Energy University Program\Integrated Research Program, NEUP\IRP, where last year is an extension of no cost project. This research work is focused on the possible degradation of dry storage canister holding used nuclear fuel (UNF), due to exposure of marine atmospheric environment. The canister usually designed from a welded austenitic stainless-steel of types 304 or 316, encased in a concrete shell known as an overpack. This canister designed and licensed for 20 years with an extension period need to be determined, in addition 20 years or more. These casks are located throughout the country in Independent Spent Fuel Storage Installations (IFSFIs) often on the site close to nuclear power plants, that are often located in coastal or lake-side regions where a marine atmospheric salt air environment exist. As a result of several recent decisions, such as not pursuing Yucca Mountain as a long-term geologic repository storage facility for UNF and the cancellation of the construction of a reprocessing facility in the 1980s due to proliferation risks, interim dry storage facilities for long-term storage are vital option for the immediate future of nuclear energy technology. One of the primary concerns with respect to the long-term performance of the storage casks is the potential for corrosion initiation due to deliquescence of salts deposited on the canister surface as aerosols; in regions of high residual weld stresses, this may lead to localized stress corrosion cracking (SCC). Dust and aerosols in the air being drawn though ventilation openings in the overpacks of passively ventilated dry canister storage systems may be deposited on the stainless-steel canister outer surfaces. Under these conditions, localized corrosion attack can occur. Chlorides ions deliquescence on the canister surface, a process by which the salts essentially pull moisture out of the air, creating a concentrated salt brine on the canister surface. Chloride-induced stress corrosion cracking (CISCC) of welded zones is of special concern, as it a well-documented mode of attack for austenitic stainless steels marine environments, and many independent spent fuel storage installations (ISFSIs) are located in coastal areas. Recent canister inspections have shown that chloride salts are present on the surface of in-service canisters at near-marine settings. However, canister surface inspections of satisfactory resolution to detect SCC have never been carried out in details, because access to the canister surfaces through vents in the overpacks is extremely limited, and high radiation fields make removal of the canisters from the overpacks undesirable. Although no significant corrosion damage has not been detected up to date, there is concern that this may lead to pitting corrosion, which could in turn develop into stress corrosion cracking, causing canister structural failure. The initiation and propagation of pitting corrosion has been widely studied in full immersion conditions, but limited studies have been done on marine atmospheric conditions, which is a focus of this work, these includes laboratory and field experimentally and propagation rate modeling of pitting and transition to crack, and crack propagation rate. It is known, however, that the rate of atmospheric corrosion can be affected by variations in relative humidity (RH), salt density, salt type, droplet area, temperature and stainless-steel microstructure and residual stress particularly in welded zones of canisters. The integrated research program has identified potential deterioration mechanisms for the stainless-steel canisters containing the UNF in dry storage that require detailed research and investigation and will have an impact on the performance of long-term interim storage under the normal and extreme environmental conditions experienced during the duration of this storage. The prediction and monitoring of canister corrosion processes while in storage can provide important data for the assessment of interim storage performance and the safety to the public. This report comprises of mainly the published results in different journals and covering a wide range spectrum from susceptible stainless-steel types 304\316 microstructural analysis through the implant test at atmospheric environment, residual stress analysis of mockup canister and simulation, inspection methodology includes nonlinear ultrasound and vibro-thermography and stochastic modeling and simulation of pits propagation rates and transition to cracks. Description of field specimens installed at ISFSI of Main Yankee is given in the following chapters and will be analyzed in the coming future and serves as an important data for a stochastic analysis as it was drawn from the publications and reports described in this report. The purpose of this report is to bring together the project efforts that includes improving in our understanding of structural aging performance at current dry storage casks fleet at ISFSIs in the context of remedial maintenance and inspection applications technologies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Influence of Metal Identity on Light-Induced Switchable Adsorption in Azobenzene-Based Metal–Organic Frameworks

Energy-efficient capture and release of small gas molecules, particularly carbon dioxide (CO 2 ) and methane (CH 4 ), are of significant interest in academia and industry. Porous materials such as metal–organic frameworks (MOFs) have been extensively studied, as their ultrahigh porosities and tunability enable significant amounts of gas to be adsorbed while also allowing specific applications to be targeted. However, because of the microporous nature of MOFs, the gas adsorption performance is dominated by high uptake capacity at low pressures, limiting their application. Hence, methods involving stimuli-responsive materials, particularly light-induced switchable adsorption (LISA), offer a unique alternative to thermal methods. Here, we report the mechanism of a well-known LISA system, the azobenzene-based material PCN-250, for CO 2 and CH 4 adsorption. There is a noticeable difference in the LISA effect dependent on the metal cluster involved, with the most significant being PCN-250-Al, where the adsorption can change by 83.1% CH 4 and 56.1% CO 2 at 298 K and 1 bar and inducing volumetric storage changes of 36.2 and 33.9 cm 3 /cm 3 at 298 K between 5 and 85 bar (CH 4 ) and 2 and 9 bar (CO 2 ), respectively. Using UV light in both single-crystal X-ray diffraction and gas adsorption testing, we show that upon photoirradiation, the framework undergoes a “localized heating” phenomenon comparable to an increase of 130 K for PCN-250-Fe and improves the working capacity. Furthermore, this process functions because of the constrained nature of the ligand, preventing the typical trans-to-cis isomerization observed in free azobenzene. In addition, we observed that the degree of localized heating is highly dependent on the metal cluster involved, with the series of isostructural PCN-250 systems showing variable performance based upon the degree of interaction between the ligand and the metal center.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NRC Technical Research Program to Evaluate Extended Storage and Transportation of Spent Nuclear Fuel - 12547

Any new direction proposed for the back-end of spent nuclear fuel (SNF) cycle will require storage of SNF beyond the current licensing periods. The Nuclear Regulatory Commission (NRC) has established a technical research program to determine if any changes in the 10 CFR part 71, and 72 requirements, and associated guidance might be necessary to regulate the safety of anticipated extended storage, and subsequent transport of SNF. This three part program of: 1) analysis of knowledge gaps in the potential degradation of materials, 2) short-term research and modeling, and 3) long-term demonstration of systems, will allow the NRC to make informed regulatory changes, and determine when and if additional monitoring and inspection of the systems is necessary. The NRC has started a research program to obtain data necessary to determine if the current regulatory guidance is sufficient if interim dry storage has to be extended beyond the currently approved licensing periods. The three-phased approach consists of: - the identification and prioritization of potential degradation of the components related to the safe operation of a dry cask storage system, - short-term research to determine if the initial analysis was correct, and - a long-term prototypic demonstration project to confirm the models and results obtained in the short-term research. The gap analysis has identified issues with the SCC of the stainless steel canisters, and SNF behavior. Issues impacting the SNF and canister internal performance such as high and low temperature distributions, and drying have also been identified. Research to evaluate these issues is underway. Evaluations have been conducted to determine the relative values that various types of long-term demonstration projects might provide. These projects or follow-on work is expected to continue over the next five years. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hvac: Removing I/O Bottleneck for Large-Scale Deep Learning Applications

Scientific communities are increasingly adopting deep learning (DL) models in their applications to accelerate scientific discovery processes. However, with rapid growth in the computing capabilities of HPC supercomputers, large-scale DL applications have to spend a significant portion of training time performing I/O to a parallel storage system. Previous research works have investigated optimization techniques such as prefetching and caching. Unfortunately, there exist non-trivial challenges to adopting the existing solutions on HPC supercomputers for large-scale DL training applications, which include non-performance and/or failures at extreme scale, lack of portability and generality in design, complex deployment methodology, and being limited to a specific application or dataset. To address these challenges, we propose High-Velocity AI Cache (HVAC), a distributed read-cache layer that targets and fully exploits the node-local storage or near node-local storage technology. HVAC seamlessly accelerates read I/O by aggregating node-local or near node-local storage, avoiding metadata lookups and file locking while preserving portability in the application code. We deploy and evaluate HVAC on 1,024 nodes (with over 6000 NVIDIA V100 GPUS) of the Summit supercomputer. In particular, we evaluate the scalability, efficiency, accuracy, and load distribution of HVAC compared to GPFS and XFS-on-NVMe. With four different DL applications, we observe an average 25 % performance improvement atop GPFS and 9% drop against XFS-on-NVMe, which scale linearly and are considered the performance upper bound. We envision HVAC as an important caching library for upcoming HPC supercomputers such as Frontier.

Khan, Awais↗

Role of Cations in the Cation-Driven Assembly Process and their Effect on the Charge Storage Properties of Bilayered Vanadium Oxide and Reduced Graphene Oxide Heterostructures in Alkali Ion Systems

Exfoliated δ-Li x V 2 O 5 ·nH 2 O (ex-LVO) and reduced graphene oxide (rGO) heterostructures were constructed using different assembling cations (i.e., Li⁺, Na⁺, and K⁺ ions). The ex-LVO and rGO nanoflakes were stacked together using a concentrated chloride solution of each assembling cation and vacuum annealed at 200 °C to form three distinct two-dimensional (2D) layered architectures. X-ray diffraction and thermogravimetric analysis confirmed that the assembling ions can control the interlayer spacing of the bilayered vanadium oxide (BVO) phase as well as impact the crystallographic water content, which in turn affects the electrochemical performance. Scanning electron microscopy, scanning transmission electron microscopy (STEM), electron energy-loss spectroscopy (EELS), and X-ray photoelectron spectroscopy confirmed that a 2D heterointerface formed between LVO and rGO and that the cations used to assemble the heterostructure are trapped in the interlayer BVO region. High-resolution STEM imaging also showed the rGO dispersion throughout the LVO layers. Moreover, STEM-EELS identified a V 2 O 3 phase that forms along the rGO interface and can stabilize the materials during cycling. A charge storage mechanism analysis, combined with the galvanostatic intermittent titration technique, found that increased interlayer spacings of the BVO phase and using the assembling cations to define intercalation sites for identical charge-carrying ions lead to improved ion diffusion and increased capacities during cycling. Therefore, the Li⁺ and Na⁺ ion assembled heterostructures showed improved charge-carrying ion diffusion and charge storage capacities in each of their respective charge storage systems (i.e., Li-ion and Na-ion half-cells). In total, the cation used for heterostructure assembly can modify the final material structure and tailor the ion diffusion and charge storage capacity to tune its properties for the desired electrochemical system using a variety of 2D materials.

25 ENERGY STORAGE↗

One System Overview - 16579

The U.S. Department of Energy (DOE), Office of River Protection (ORP) is responsible for managing and completing the River Protection Project mission, which is to 'safeguard the nuclear waste stored in Hanford's 177 underground tanks, and to manage the waste safely and responsibly until it can be treated in the Waste Treatment and Immobilization Plant for final disposition'. The Office of River Protection's work scope is currently performed through two primary contracts: - The Tank Operations Contract, held by Washington River Protection Solutions LLC, (WRPS) includes the construction, operation, and maintenance activities necessary to safely store, retrieve, and transfer tank wastes; provide supplemental tank waste treatment; provide storage and/or disposal of primary and secondary waste streams; design, construction and commissioning of the Low-Activity Waste Pretreatment System; and support ORP to integrate Hanford Tank Waste Treatment and Immobilization Plant (WTP) completion and startup with Tank Farms operations. - The WTP Contract, held by Bechtel National, Inc. (BNI), includes the design, construction, and commissioning of a Pretreatment Facility, two vitrification facilities (one for high-level waste and one for low-activity waste), a dedicated analytical laboratory, and supporting facilities to treat radioactive tank wastes by immobilizing them into a stable glass waste form. One System was established as a means to improve the integration between the tank farms and the WTP project to support its safe and successful startup. One System's scope and purpose focus on mission integration consistent with DOE's plans to treat tank waste in phases, starting with direct feed of the low-activity waste stream to the WTP's Low-Activity Waste (LAW) Vitrification Facility (referred to as DFLAW). The One System organization now has four major focus areas: - Flowsheet Integration? Integrated River Protection Project (RPP) flowsheet development and management; developing a gaps, risks, and opportunities management plan and technical roadmap; and waste feed qualification. - Mission Analysis and Planning? Strategic planning, system planning, and modeling integration. - WTP Startup, Commissioning, and Operations Integration? Interface Control Document (ICD) management, coordinating facilities startup-to-commissioning-to-operations, contract directives and standards identification, and DFLAW program integration. - Project Integration and Controls? Integrated schedule, metrics/dashboards monitoring, and One System risk register. ORP established the DFLAW Program Office in February 2015 as one of its key performance goals. ORP staff, along with contractor managers, have identified roles and responsibilities for the each of the four major focus areas. One System has established an Executive Council and Governance Board to drive program progress and make decisions on DFLAW. This approach allows appropriate government and contractor senior management involvement in the DFLAW Program. Monthly critical path analysis on the integrated DFLAW schedule is being performed. Interface control documents specific to DFLAW have been developed, and system planning and modeling tools are being used to help define the DFLAW flowsheet. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗