Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Observations of microwave continuum emission from air shower plasmas

We investigate a possible new technique for microwave detection of cosmic-ray extensive air showers which relies on detection of expected continuum radiation in the microwave range, caused by free-electron collisions with neutrals in the tenuous plasma left after the passage of the shower. We performed an initial experiment at the Argonne Wakefield Accelerator laboratory in 2003 and measured broadband microwave emission from air ionized via high-energy electrons and photons. A follow-up experiment at the Stanford Linear Accelerator Center in the summer of 2004 confirmed the major features of the previous Argonne Wakefield Accelerator observations with better precision. Prompted by these results we built a prototype detector using satellite television technology and have made measurements suggestive of the detection of cosmic-ray extensive air showers. The method, if confirmed by experiments now in progress, could provide a high-duty cycle complement to current nitrogen fluorescence observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Research and Development for Ultra-High Gradient Accelerator Structures

Research on the basic physics of high-gradient, high frequency accelerator structures and the associated RF-microwave technology are essential for the future of discovery science, medicine and biology, energy and environment, and national security. We will review the state-of-the-art for the development of high gradient linear accelerators. We will present the research activities aimed at exploring the basic physics phenomenon of RF breakdown. We present the experimental results of a true systematic study in which the surface processing, geometry, and materials of the structures have been varied, one parameter at a time. The breakdown rate or alternatively, the probability of breakdown-pulse-meter has been recorded for different operating parameters. These statistical data reveal a strong dependence of breakdown probability on surface magnetic field, or alternatively on surface pulsed heating. This is in contrast to the classical view of electric field dependence.

43 PARTICLE ACCELERATORS↗

A Proposed High-Energy, Compact, Optical Electron Accelerator Based on Particle Acceleration by Stimulated Emission of Radiation

A new type of advanced accelerator is proposed that is capable of producing high-energy electron beams in a compact geometry, but does not require a high-power laser beam driver nor a linear accelerator. Moreover, it is capable of generating its own microbunched electron beam source and, thus, an electron gun is also not needed. Hence, this has the potential to enable development of compact, high-energy accelerators that are less complex and less costly.

43 PARTICLE ACCELERATORS↗

Beam line shielding calculations for an Electron Accelerator Mo-99 production facility

The purpose of this study is to evaluate the photon and neutron fields in and around the latest beam line design for the Mo-99 production facility. The radiation dose to the beam line components (quadrupoles, dipoles, beam stops and the linear accelerator) are calculated in the present report. The beam line design assumes placement of two cameras: infra red (IR) and optical transition radiation (OTR) for continuous monitoring of the beam spot on target during irradiation. The cameras will be placed off the beam axis offset in vertical direction. We explored typical shielding arrangements for the cameras and report the resulting neutron and photon dose fields.

43 PARTICLE ACCELERATORS↗

Low Emittance, High Brilliance Relativistic Electron Beams from a Laser-Plasma Accelerator

Progress in laser wakefield accelerators indicates their suitability as a driver of compact free-electron lasers (FELs). High brightness is defined by the normalized transverse emittance, which should be less than 1{pi} mm mrad for an x-ray FEL. We report high-resolution measurements of the emittance of 125 MeV, monoenergetic beams from a wakefield accelerator. An emittance as low as 1.1{+-}0.1{pi} mm mrad is measured using a pepper-pot mask. This sets an upper limit on the emittance, which is comparable with conventional linear accelerators. A peak transverse brightness of 5x10{sup 15} A m{sup -1} rad{sup -1} makes it suitable for compact XUV FELs.

43 PARTICLE ACCELERATORS↗

Research and Development for Ultra-High Gradient Accelerator Structures

Research on the basic physics of high-gradient, high frequency accelerator structures and the associated RF/microwave technology are essential for the future of discovery science, medicine and biology, energy and environment, and national security. We will review the state-of-the-art for the development of high gradient linear accelerators. We will present the research activities aimed at exploring the basic physics phenomenon of RF breakdown. We present the experimental results of a true systematic study in which the surface processing, geometry, and materials of the structures have been varied, one parameter at a time. The breakdown rate or alternatively, the probability of breakdown/pulse/meter has been recorded for different operating parameters. These statistical data reveal a strong dependence of breakdown probability on surface magnetic field, or alternatively on surface pulsed heating. This is in contrast to the classical view of electric field dependence.

43 PARTICLE ACCELERATORS↗

Accelerator commissioning and rare isotope identification at the Facility for Rare Isotope Beams

In 2008, Michigan State University was selected to establish the Facility for Rare Isotope Beams (FRIB). Construction of the FRIB accelerator was completed in January 2022. Phased accelerator commissioning with heavy ion beams started in 2017 with the normal-conducting ion source and radio-frequency quadrupole. In April 2021, the full FRIB driver linear accelerator (linac) was commissioned, with heavy ion beams accelerated to energies above 200 MeV/nucleon by 324 superconducting radiofrequency (SRF) resonators operating at 2 K and 4 K with liquid-helium cooling. Further, in preparation for high-power operation, a liquid lithium charge stripper was commissioned with heavy ion beams up to uranium-238, followed by the simultaneous acceleration of multiple-charge-state heavy ion beams to energies above 200 MeV/nucleon. In December 2021, selenium-84 was produced with the FRIB target using a krypton-86 primary beam, demonstrating FRIB’s capability for scientific discovery.

07 ISOTOPE AND RADIATION SOURCES↗

Simulation of Modulated Electron Beams in an Rf Electron Gun

Computer simulations are used to investigate the evolution of longitudinal density and energy modulations of an electron beam in a linear accelerator system. This study examines the effect of initial energy spread on the modulations as the beam is accelerated in the electron gun.

43 PARTICLE ACCELERATORS↗

Diagnostics for the optimization of an 11 keV inverse Compton scattering x-ray source

In a scope of a collaboration between Thales Communications and Security and CEA DAM DIF, 11 keV Xrays were produced by inverse Compton scattering on the ELSA facility. In this type of experiment, X-ray observation lies in the use of accurate electron and laser beam interaction diagnostics and on fitted X-ray detectors. The low interaction probability between < 100 {mu}m width, 12 ps [rms] length electron and photon pulses requires careful optimization of pulse spatial and temporal covering. Another issue was to observe 11 keV X-rays in the ambient radioactive noise of the linear accelerator. For that, we use a very sensitive detection scheme based on radio luminescent screens.

43 PARTICLE ACCELERATORS↗

Production of BaBar Skimmed Analysis Datasets Using the Grid

The BABAR Collaboration, based at Stanford Linear Accelerator Center (SLAC), Stanford, US, has been performing physics reconstruction, simulation studies and data analysis for 8 years using a number of compute farms around the world. Recent developments in Grid technologies could provide a way to manage the distributed resources in a single coherent structure. We describe enhancements to the BABAR experiment's distributed skimmed dataset production system to make use of European Grid resources and present the results with regard to BABAR's latest cycle of skimmed dataset production. We compare the benefits of a local and Grid-based systems, the ease with which the system is managed and the challenges of integrating the Grid with legacy software. We compare job success rates and manageability issues between Grid and non-Grid production.

43 PARTICLE ACCELERATORS↗

Cumulative short-lived photofission product yields for nuclear forensic application

Experiments have long been carried out with linear accelerator (linac) produced bremsstrahlung X-rays to study high-energy photon-induced fission, known as “photofission”. One benefit of photofission, when compared with neutron-induced fission, is the ability to investigate fundamental physics of fission at excitation energies lower than what is possible with neutrons [1]. Absorption of an incident neutron results in a compound nucleus with an excitation energy at least equal to the neutron binding energy; thus, the lowest energy region of the fission barrier cannot be studied. Fission product yield distributions are dependent on the incident particle energy and the target nucleus mass. They are generally represented by a double-humped curve, with low and high mass “peaks” and an intermediate mass “valley”. As incident particle energy increases, the excitation energy of the nucleus increases, thereby increasing the overall yield of isotopes in the valley with respect to the two maxima or peaks of the fission product curve [3]. Photofission is most probable for incident photons around 14 MeV due to the giant dipole resonance. Induced photofission around this energy results in a fission product yield distribution that resembles 14 MeV DT neutron fission more than thermal or fast (500 keV) neutron fission. In post-detonation nuclear forensics, the peak-to-valley ratio of the fission product yield curve could be used for characterizing device type by providing an indication of the neutron energy spectrum that had induced fission (e.g., 500 keV vs. 14 MeV). The goal of this work is to improve nuclear data for isotopes of interest in nuclear forensics and special nuclear material (SNM) detection, specifically the fission product yield data via photofission experiments for the isotopes of 238U and 232Th. Photofission has been proposed as a less costly and more flexible production method for the valley isotopes that are representative of DT neutron fission product yield distributions, which would benefit nuclear forensics exercises in testing for analysis techniques. Natural uranium and thorium targets were irradiated with bremsstrahlung photons (nominal endpoint energies of 8, 14, and 20 MeV), generated via impingement of high-energy electrons on a tungsten electron-to-photon radiator. Gamma-ray spectroscopy was used to observe and identify the decay of the resulting fission products. The photofission yields of 102 fission products were measured for the set of the 238U and 232Th targets at the three bremsstrahlung X-ray endpoint energies 8, 14, and 20 MeV. These fragments included masses ranging from A=84 to A=144, with half-lives as short as 1.07 seconds.

07 ISOTOPE AND RADIATION SOURCES↗

Measurements of time-dependent CP asymmetries in B0 --> D(*)+D(*)- decays

We present new measurements of time-dependent CP asymmetries for B{sup 0} {yields} D{sup (*)+}d{sup (*)-} decays using (467 {+-} 5) x 10{sup 6} B{bar B} pairs collected with the BABAR detector located at the PEP-II B Factory at the Stanford Linear Accelerator Center. We determine the CP-odd fraction of the B{sup 0} {yields} D*{sup +}D*{sup -} decays to be R{perpendicular} = 0.158 {+-} 0.028 {+-} 0.006 and find CP asymmetry parameters for the CP-even component of the decay S{sub +} = -0.76 {+-} 0.16 {+-} 0.04 and C{sub +} = 0.00 {+-} 0.12 {+-} 0.02. We measure S = -0.63{+-}0.36{+-}0.05 and C = -0.07{+-}0.23{+-}0.03 for B{sup 0} {yields} D{sup +}D{sup -}, S = -0.62{+-}0.21{+-}0.03 and C = 0.08 {+-} 0.17 {+-} 0.04 for B{sup 0} {yields} D*{sup +}D{sup -}, and S = -0.73 {+-} 0.23 {+-} 0.05 and C = 0.00 {+-} 0.17 {+-} 0.03 for B{sup 0} {yields} D{sup +}D*{sup -}. For the B{sup 0} {yields} D*{sup {+-}}D{sup {-+}} decays, we also determine the CP-violating asymmetry A = 0.008 {+-} 0.048 {+-} 0.013. In each case, the first uncertainty is statistical and the second is systematic. The measured values for the asymmetries are all consistent with the Standard Model.

43 PARTICLE ACCELERATORS↗

SU-F-T-557: Evaluation of Detector Response in Rectangular Small Field Dosimetry

Purpose: As stereotactic treatment modalities grow towards becoming the standard of care, the need for accurate dose computation in small fields is becoming increasingly essential. The purpose of this study is to evaluate the response of different detectors, intended for small field dosimetry, in jaw defined small rectangular fields by analyzing output factors from a stereotactic clinical accelerator. Methods: Two Dosimeters, the Exradin A26 Microionization Chamber (Standard Imaging) and Edge Diode Detector (Sun Nuclear) were used to measure output factors taken on the Varian Edge Stereotactic Linear accelerator. Measurements were taken at 6MV and 6FFF at 10cm depth, 100cm SSD in a 48×48×40cm3 Welhoffer BluePhantom2 (IBA) with X and Y jaws set from 0.6 to 2.0cm. Output factors were normalized to a 5×5cm2 machine-specific reference field. Measurements were made in the vertical orientation for the A26 and horizontal orientation for both the A26 and Edge. Output factors were measured as: OF{sub FS} = M{sub FS}/M{sub ref} where M{sub FS} and M{sub ref} are the measured signals for the clinical field and the reference field, respectively. Measured output factors were then analyzed to establish relative responses of the detectors in small fields. Results: At 6MV the Edge detector exhibited a variation in output factors dependent on jaw positioning (X-by-Y vs Y-by-X) of 5.7% of the 5×5cm reference output and a variation of 3.33% at 6FFF. The A26 exhibited variation of output factor dependent on jaw positioning of upto 7.7% of the 5×5cm reference field at 6MV and upto 5.33% at 6FFF. Conclusion: Both the Edge detector and A26 responded as expected at small fields however a dependence on the jaw positioning was noted. At 6MV and 6FFF the detector response showed an increased dependence on the positioning of the X jaws as compared to the positioning of the Y jaws.

60 APPLIED LIFE SCIENCES↗

First Experience With Markerless Online 3D Spine Position Monitoring During SBRT Delivery Using a Conventional LINAC

The purpose was to report our initial experience with online markerless 3-dimensional (3D) spine position monitoring. We used template matching plus triangulation of fluoroscopic kilovoltage images acquired with the gantry-mounted imager during flattening filter-free volumetric modulated arc spine stereotactic body radiation therapy delivery on a conventional linear accelerator.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser-Compton X-rays for Medical and Industrial Imaging Studies

A high-energy quasi-monochromatic x-ray beam is generated via the laser-Compton scattering of intense laser pulses with low-emittance electron bunches. A compact electron linear accelerator of 40 MeV with Ti:Sapphire femtosecond terawatt laser system, and an 800-MeV electron storage ring with continuous-wave or Q-switched laser systems are used to generate hard x-rays and gamma-rays, respectively both in AIST.

43 PARTICLE ACCELERATORS↗

Calculation and Verification of a Planar Pencil Beam Kernel Through the Hankel Transform of Measured OARs for a Radiosurgery System with Cones

A planar multienergetic pencil beam kernel with rotational symmetry is calculated for a stereotactic radiosurgery system, SRS, BrainLAB with cones, employing the deconvolution method of the off axis ratio profile, OAR, corresponding to the cone of 35 mm in diameter for a 6 MV photon beam produced by a linear accelerator Varian 2100 C/D. Before the deconvolution, the experimental OAR is corrected for beam divergence and variations of the spectral fluence {Phi}, using a boundary function BF. The function BF and the fluence {Phi} are transformed to the conjugate space with the zero order Hankel function, which is the appropriate transform due to the radial symmetry of the circular beams generated by the cones. The kernel in the conjugate space is obtained as the ratio of the transform of BF to the transform of {Phi}, therefore the kernel in the real space is calculated as the inverse transform of the kernel in the conjugate space. To validate the kernel in the real space, it is convolved with the fluence of the cones of 7.5, 12.5, 15, 17.5, 20, 22.5, 25, 30 and 35 mm in diameter. The comparison of the OARs calculated and measured shows a maximum difference of 4.5% in the zones of high gradient of dose, and a difference less than 2% in the regions of low gradient of dose. Finally, the expanded uncertainty of the kernel is estimated and reported.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Note: Characteristic beam parameter for the line electron gun

We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm{sup 2} at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm{sup 2}), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

43 PARTICLE ACCELERATORS↗

Design Studies for a VUV--Soft X-ray Free-Electron Laser Array

Several recent reports have identified the scientific requirements for a future soft X-ray light source [1, 2, 3, 4, 5], and a high-repetition-rate free-electron laser (FEL) facility responsive to them is being studied at Lawrence Berkeley National Laboratory (LBNL) [6]. The facility is based on a continuous-wave (CW) superconducting linear accelerator with beam supplied by a high-brightness, high-repetition-rate photocathode electron gun operating in CW mode, and on an array of FELs to which the accelerated beam is distributed, each operating at high repetition rate and with even pulse spacing. Dependent on the experimental requirements, the individualFELs may be configured for either self-amplified spontaneous emission (SASE), seeded highgain harmonic generation (HGHG), echo-enabled harmonic generation (EEHG), or oscillator mode of operation, and will produce high peak and average brightness x-rays with a flexible pulse format ranging from sub-femtoseconds to hundreds of femtoseconds. This new light source would serve a broad community of scientists in many areas of research, similar to existing utilization of storage ring based light sources. To reduce technical risks and constructioncosts, accelerator research, development, and design studies at LBNL target the most critical components and systems of the facility. We are developing a high-repetition-rate low-emittance electron gun, high quantum efficiency photocathodes, and have embarked on design and optimization of the electron beam accelerator, FEL switchyard, and array of FELs. We continue our work on precision timing and synchronization systems critical for time-resolved experiments using pump-probe techniques.

43 PARTICLE ACCELERATORS↗