Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Validation of MPACT BWR capabilities against critical experiments

Over the years, significant validation work for the neutronics code MPACT has been performed against zero-power critical benchmarks and measured data from operating nuclear power plants. As a part of the Modeling and Analysis of Exelon BWRs for Eigenvalue and Thermal Limits Predictability project, new validation efforts relevant to boiling water reactor (BWR) core applications have been performed. This paper presents the results of the critical experiment portion of the BWR validation efforts for MPACT. The Kritz-4 experiments and IPEN/MB-01 BWR-relevant configurations are modeled with MPACT. The Kritz-4 BWR critical experiments were performed at both cold and hot conditions, which is a unique feature among other critical experiment facilities. The MPACT results with linear source (LS) Method of Characteristics (MOC) have very good agreement with the measured criticality. When using the 60-group BWR library with LS and P2 scattering, the maximum k{sub eff} error is 109 pcm, and the average cold-hot bias is only -0.11 pcm/K. The fission rate distributions of MPACT are also verified with Serpent calculations. For the IPEN facility, two configurations are considered: one with a large central void, and one with a cruciform control rod. The MPACT k{sub eff} errors are less than 50 pcm for all IPEN problems. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TU-C-BRE-03: Aggregation of Linac Measurement Data

Purpose: Accurate data of linear accelerator radiation characteristics is important for treatment planning system commissioning as well as regular quality assurance of the machine. The RPC has performed site visits of numerous machines . Data gathered from Varian machines from the past 15 years are presented. The data collected can be used as a secondary check or when commissioning a new machine to verify that values are reasonable. Methods: Data from the past 15 years of RPC site visits was compiled and analyzed. Data was composed from measurements from approximately 400 Varian machines. Each dataset consists of several point measurements at various locations in a water phantom to measure percentage depth dose, output factors, including small MLC fields, off-axis factors, and wedge factors if applicable. Common statistical values are presented for each machine type. Where applicable, data was compared to other reference data given by the vendor or a select number of previous researchers. Results: Data is separated by energy and parameter and then analyzed by machine class. Data distributions of the parameter data were normal except occasionally at the tails. Distributions of the data for each class and parameter are tabulated to give not simply a singular reference value, but metrics about the distribution: 5th and 95th percentile values and the standard deviation as well as the median. Conclusion: The RPC has collected numerous data on Varian linacs and presented the finding of the past 15 years. The data can be used as a reference data set for physicists to compare against. A linac that deviates from the values does not necessarily indicate there is a problem as long as the treatment planning system correlates to the machine. Comparison of linac and treatment planning system data to external reference data can prevent serious treatment errors.

07 ISOTOPE AND RADIATION SOURCES↗

On the geometric dependence of the molecular dipole polarizability in water: A benchmark study of higher-order electron correlation, basis set incompleteness error, core electron effects, and zero-point vibrational contributions

In this work, we investigate how geometric changes influence the static dipole polarizability ($α$) of a water molecule by explicitly computing the corresponding dipole polarizability surface (DPS) across 3125 total (1625 symmetry-unique) geometries using linear response coupled cluster theory including single, double, and triple excitations (LR-CCSDT) and the doubly augmented triple-$ζ$ basis set (d-aug-cc-pVTZ). Analytical formulae based on power series expansions of this $ab initio$ surface are generated using linear least-squares analysis and provide highly accurate estimates of this quantity as a function of molecular geometry (i.e., bond and angle variations) in a computationally tractable manner. An additional database, which consists of 25 representative molecular geometries and incorporates a more thorough treatment of both basis sets and core electron effects, is provided as a current benchmark for this quantity and the corresponding leading-order $C_6$ dispersion coefficient. This database has been utilized to assess the importance of these effects as well as the relative accuracy that can be obtained using several quantum chemical methods and a library of density functional approximations. In addition to high-level electron correlation methods (like CCSD) and our analytical least-squares formulae, we find that the SCAN0, PBE0, MN15, and B97-2 hybrid functionals yield the most accurate descriptions of the molecular polarizability tensor in H 2 O. Using first-order perturbation theory, we compute the zero-point vibrational correction to $α$ at the CCSDT/d-aug-cc-pVTZ level and find that this correction contributes approximately 3% to the isotropic ($α$ iso ) and nearly 50% to the anisotropic ($α$ aniso ) polarizability values. In doing so, we find that $α$ iso = 9.8307 bohr 3 , which is in excellent agreement with the experimental value of 9.83 ± 0.02 bohr 3 provided by Russell and Spackman. The DPS reported herein provides a benchmark-quality quantum mechanical estimate of this fundamental quantity of interest and should find extensive use in the development (and assessment) of next-generation force fields and machine-learning based approaches for modeling water in complex condensed-phase environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrodynamic characterization of the coastal pioneer array ocean observing system

Ocean observation buoys require relatively small amounts of power, yet traditionally necessitate costly resupply trips for battery replacement. With the offshore location of the buoys and small power requirements, wave energy may be an effective solution for providing consistent and reliable power to support the buoy instrumentation. The US National Science Foundation Ocean Observatories Initiative (OOI) includes arrays of point absorber-like buoy systems used for ocean observation that have been deployed at multiple locations including the Southern Mid-Atlantic Bight. A study is currently underway to design a pitch resonator wave energy converter to supplement existing renewable energy generation for powering observation instrumentation. This paper details field measurements from surface moorings of the OOI Coastal Pioneer Array, which informs the subsequent development of a numerical model for the moored observation system. The model is developed in Wave Energy Converter Simulator (WEC-Sim), which leverages the Simscape multibody solver within the MATLAB/Simulink framework and linear potential flow theory to simulate the hydrodynamic interactions and multibody dynamics in 6 degrees of freedom. Multiple tuning variables are considered to produce a model for the system that matches well with empirical data (about 8% error). In conclusion, the WEC-Sim model will serve as a platform for integrating the pitch resonator wave energy converter concept and deployment preparation (detailed design including power take-off and control systems, response evaluation, etc.).

hydrodynamic modeling↗

Soil Respiration Variability and Correlation Across a Wide Range of Temporal Scales

Abstract The high temporal variability of the soil‐to‐atmosphere CO 2 flux (soil respiration, R S ) has been studied at hourly to multiannual time scales but remains less well understood than R S spatial variability. How R S fluxes vary and are autocorrelated at various time lags has practical implications for sampling and more fundamentally for our understanding of its abiotic and biotic underlying mechanisms. We examined the variability, correlation, and sampling requirements of R S over a wide range of temporal scales in a temperate deciduous forest in eastern Maryland, USA, using both automated (temporally continuous, N = 30,036 over 10 months) and survey (spatially diverse, temporally sparse, N = 1,912 over 17 months) data. Data from a global R S database were also used to examine interannual variability in comparable forests. The coefficient of variability of successive measurements generally varied from the minute (median coefficient of variation 16%) to hourly and daily (11–12%) time scales. Successive R S values measured at a given collar exhibited a strong hour‐to‐hour correlation ( r = 0.931) and a moderate correlation at a 2‐hr lag (0.289); day‐to‐day (i.e., 24 hr lag) hourly observations were uncorrelated. Daily R S means were well correlated at a 1‐day lag ( r = 0.856) but not at any further time lag. In a linear mixed‐effects model predicting R S , soil temperature and moisture exerted consistently strong effects regardless of time scale, and model coefficient of variability was generally high (>80%). These results provide new opportunities to explore the drivers and variability of R S fluxes, quantify sampling requirements, and improve error propagation.

Bond‐Lamberty, Ben↗

An integral quality monitoring system for real-time verification of intensity modulated radiation therapy

Purpose: To develop an independent and on-line beam monitoring system, which can validate the accuracy of segment-by-segment energy fluence delivery for each treatment field. The system is also intended to be utilized for pretreatment dosimetric quality assurance of intensity modulated radiation therapy (IMRT), on-line image-guided adaptive radiation therapy, and volumetric modulated arc therapy. Methods: The system, referred to as the integral quality monitor (IQM), utilizes an area integrating energy fluence monitoring sensor (AIMS) positioned between the final beam shaping device [i.e., multileaf collimator (MLC)] and the patient. The prototype AIMS consists of a novel spatially sensitive large area ionization chamber with a gradient along the direction of the MLC motion. The signal from the AIMS provides a simple output for each beam segment, which is compared in real time to the expected value. The prototype ionization chamber, with a physical area of 22x22 cm{sup 2}, has been constructed out of aluminum with the electrode separations varying linearly from 2 to 20 mm. A calculation method has been developed to predict AIMS signals based on an elementwise integration technique, which takes into account various predetermined factors, including the spatial response function of the chamber, MLC characteristics, beam transmission through the secondary jaws, and field size factors. The influence of the ionization chamber on the beam has been evaluated in terms of transmission, surface dose, beam profiles, and depth dose. The sensitivity of the system was tested by introducing small deviations in leaf positions. A small set of IMRT fields for prostate and head and neck plans was used to evaluate the system. The ionization chamber and the data acquisition software systems were interfaced to two different types of linear accelerators: Elekta Synergy and Varian iX. Results: For a 10x10 cm{sup 2} field, the chamber attenuates the beam intensity by 7% and 5% for 6 and 18 MV beams, respectively, without significantly changing the depth dose, surface dose, and dose profile characteristics. An MLC bank calibration error of 1 mm causes the IQM signal of a 3x3 cm{sup 2} aperture to change by 3%. A positioning error in a single 5 mm wide leaf by 3 mm in 3x3 cm{sup 2} aperture causes a signal difference of 2%. Initial results for prostate and head and neck IMRT fields show an average agreement between calculation and measurement to within 1%, with a maximum deviation for each of the smallest beam segments to within 5%. When the beam segments of a prostate IMRT field were shifted by 3 mm from their original position, along the direction of the MLC motion, the IQM signals varied, on average, by 2.5%. Conclusions: The prototype IQM system can validate the accuracy of beam delivery in real time by comparing precalculated and measured AIMS signals. The system is capable of capturing errors in MLC leaf calibration or malfunctions in the positioning of an individual leaf. The AIMS does not significantly alter the beam quality and therefore could be implemented without requiring recommissioning measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acoustically determined linear piezoelectric response of lithium niobate up to 1100 V

We present a method to measure high voltages using the piezoelectric crystal lithium niobate without using voltage dividers. A 36° Y-X cut lithium niobate crystal was coupled to two acoustic transducers, where direct current voltages were applied from 128–1100 V. The time-of-flight through the crystal was determined to be linearly dependent on the applied voltage. A model was developed to predict the time-delay in response to the applied voltage. The results show a sensitivity of 17 fs/V with a measurement error of 1 fs/V was achievable using this method. The sensitivity of this method can be increased by measuring the acoustic wave after multiple passes through the crystal. This method has many advantages over traditional techniques such as: favorable scalability for larger voltages, ease of use, cost effectiveness, and compactness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accurate electronic and chemical properties of 3d transition metal oxides using a calculated linear response U and a DFT + U(V) method

We validate the usage of the calculated, linear response Hubbard U for evaluating accurate electronic and chemical properties of bulk 3d transition metal oxides. We find calculated values of U lead to improved band gaps. For the evaluation of accurate reaction energies, we first identify and eliminate contributions to the reaction energies of bulk systems due only to changes in U and construct a thermodynamic cycle that references the total energies of unique U systems to a common point using a DFT + U(V ) method, which we recast from a recently introduced DFT + U(R) method for molecular systems. We then introduce a semi-empirical method based on weighted DFT/DFT + U cohesive energies to calculate bulk oxidation energies of transition metal oxides using density functional theory and linear response calculated U values. We validate this method by calculating 14 reactions energies involving V, Cr, Mn, Fe, and Co oxides. We find up to an 85% reduction of the mean average error (MAE) compared to energies calculated with the Perdew-Burke-Ernzerhof functional. When our method is compared with DFT + U with empirically derived U values and the HSE06 hybrid functional, we find up to 65% and 39% reductions in the MAE, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TESTING TESTS ON ACTIVE GALACTIC NUCLEI MICROVARIABILITY

Literature on optical and infrared microvariability in active galactic nuclei (AGNs) reflects a diversity of statistical tests and strategies to detect tiny variations in the light curves of these sources. Comparison between the results obtained using different methodologies is difficult, and the pros and cons of each statistical method are often badly understood or even ignored. Even worse, improperly tested methodologies are becoming more and more common, and biased results may be misleading with regard to the origin of the AGN microvariability. This paper intends to point future research on AGN microvariability toward the use of powerful and well-tested statistical methodologies, providing a reference for choosing the best strategy to obtain unbiased results. Light curves monitoring has been simulated for quasars and for reference and comparison stars. Changes for the quasar light curves include both Gaussian fluctuations and linear variations. Simulated light curves have been analyzed using {chi}{sup 2} tests, F tests for variances, one-way analyses of variance and C-statistics. Statistical Type I and Type II errors, which indicate the robustness and the power of the tests, have been obtained in each case. One-way analyses of variance and {chi}{sup 2} prove to be powerful and robust estimators for microvariations, while the C-statistic is not a reliable methodology and its use should be avoided.

79 ASTRONOMY AND ASTROPHYSICS↗

RESOLVED GIANT MOLECULAR CLOUDS IN NEARBY SPIRAL GALAXIES: INSIGHTS FROM THE CANON CO (1-0) SURVEY

We resolve 182 individual giant molecular clouds (GMCs) larger than 2.5 Multiplication-Sign 10{sup 5} M{sub Sun} in the inner disks of 5 large nearby spiral galaxies (NGC 2403, NGC 3031, NGC 4736, NGC 4826, and NGC 6946) to create the largest such sample of extragalactic GMCs within galaxies analogous to the Milky Way. Using a conservatively chosen sample of GMCs most likely to adhere to the virial assumption, we measure cloud sizes, velocity dispersions, and {sup 12}CO (J = 1-0) luminosities and calculate cloud virial masses. The average conversion factor from CO flux to H{sub 2} mass (or X{sub CO}) for each galaxy is 1-2 Multiplication-Sign 10{sup 20} cm{sup -2} (K km s{sup -1}){sup -1}, all within a factor of two of the Milky Way disk value ({approx}2 Multiplication-Sign 10{sup 20} cm{sup -2} (K km s{sup -1}){sup -1}). We find GMCs to be generally consistent within our errors between the galaxies and with Milky Way disk GMCs; the intrinsic scatter between clouds is of order a factor of two. Consistent with previous studies in the Local Group, we find a linear relationship between cloud virial mass and CO luminosity, supporting the assumption that the clouds in this GMC sample are gravitationally bound. We do not detect a significant population of GMCs with elevated velocity dispersions for their sizes, as has been detected in the Galactic center. Though the range of metallicities probed in this study is narrow, the average conversion factors of these galaxies will serve to anchor the high metallicity end of metallicity-X{sub CO} trends measured using conversion factors in resolved clouds; this has been previously possible primarily with Milky Way measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Classical Simulation of Boson Sampling Based on Graph Structure

Boson sampling is a fundamentally and practically important task that can be used to demonstrate quantum supremacy using noisy intermediate-scale quantum devices. In this Letter, we present classical sampling algorithms for single-photon and Gaussian input states that take advantage of a graph structure of a linear-optical circuit. The algorithms’ complexity grows as so-called treewidth, which is closely related to the connectivity of a given linear-optical circuit. Using the algorithms, we study approximated simulations for local Haar-random linear-optical circuits. For equally spaced initial sources, we show that, when the circuit depth is less than the quadratic in the lattice spacing, the efficient simulation is possible with an exponentially small error. Notably, right after this depth, photons start to interfere each other and the algorithms’ complexity becomes subexponential in the number of sources, implying that there is a sharp transition of its complexity. Finally, when a circuit is sufficiently deep enough for photons to typically propagate to all modes, the complexity becomes exponential as generic sampling algorithms. We numerically implement a likelihood test with a recent Gaussian boson sampling experiment and show that the treewidth-based algorithm with a limited treewidth renders a larger likelihood than the experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AXI4MLIR: User-Driven Automatic Host Code Generation for Custom AXI-Based Accelerators

Tensor algebra operations represent an important class of algorithms used across many applications, including machine learning, scientific computing, and data analytics. As a result, the efficient generation of custom accelerators for tensor operations has received increased attention. Previous efforts have produced automated tools enabling users to prototype and explore optimized accelerators. However, little effort has been focused on the host-accelerator interaction in these tools. Efficient use of hardware accelerators requires knowledge about the accelerator's capabilities (operations, data formats, and opcode support), the host CPU microarchitecture (e.g., memory hierarchy), the host-accelerator interface, and the application's features (which code regions should be mapped onto an accelerator). Manually rewriting the original applications to facilitate improved custom accelerator mapping is an error-prone and time-consuming endeavor. To cope with this, we propose AXI4MLIR, a new framework to automatically generate and optimize the communication between the host CPU and arbitrary accelerators that implement linear algebra algorithms. AXI4MLIR extends the MLIR compiler framework to automatically generate efficient host-accelerator driver code for accelerators with AXI-based interfaces. Our compiler extensions enable automatic driver code generation while carefully considering the host's memory hierarchy and target accelerator features. To demonstrate the flexibility and utility of AXI4MLIR, we test it with diverse use cases that include different types of accelerators, tiling scenarios, and dataflow schemes. We compare our experimental results to manual implementations of host-accelerator driver code and find that our approach can reduce CPU cache references by 56% and deliver up to a 1.65x speedup.

Bohm Agostini, Nicolas↗

Chance-Constrained AC Optimal Power Flow for Distribution Systems With Renewables

This paper focuses on distribution systems featuring renewable energy sources (RESs) and energy storage systems, and presents an AC optimal power flow (OPF) approach to optimize system-level performance objectives while coping with uncertainty in both RES generation and loads. The proposed method hinges on a chance-constrained AC OPF formulation where probabilistic constraints are utilized to enforce voltage regulation with prescribed probability. A computationally more affordable convex reformulation is developed by resorting to suitable linear approximations of the AC power-flow equations as well as convex approximations of the chance constraints. The approximate chance constraints provide conservative bounds that hold for arbitrary distributions of the forecasting errors. An adaptive strategy is then obtained by embedding the proposed AC OPF task into a model predictive control framework. Finally, a distributed solver is developed to strategically distribute the solution of the optimization problems across utility and customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LOGISTIC FUNCTION PROFILE FIT: A least-squares program for fitting interface profiles to an extended logistic function

The extended logistic function provides a physically reasonable description of interfaces such as depth profiles or line scans of surface topological or compositional features. It describes these interfaces with the minimum number of parameters, namely, position, width, and asymmetry. Logistic Function Profile Fit (LFPF) is a robust, least-squares fitting program in which the nonlinear extended logistic function is linearized by a Taylor series expansion (equivalent to a Newton-Raphson approach) with no apparent introduction of bias in the analysis. The program provides reliable confidence limits for the parameters when systematic errors are minimal and provides a display of the residuals from the fit for the detection of systematic errors. The program will aid researchers in applying ASTM E1636-10, 'Standard practice for analytically describing sputter-depth-profile and linescan-profile data by an extended logistic function,' and may also prove useful in applying ISO 18516: 2006, 'Surface chemical analysis-Auger electron spectroscopy and x-ray photoelectron spectroscopy-determination of lateral resolution.' Examples are given of LFPF fits to a secondary ion mass spectrometry depth profile, an Auger surface line scan, and synthetic data generated to exhibit known systematic errors for examining the significance of such errors to the extrapolation of partial profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-C-BRE-06: Effect of Implementing In-House Treatment Couch Model On Patient Specific QA for Pinnacle SmartArc Treatment Plans

Purpose: Failure to model the treatment couch during VMAT QA planar dose calculation may Result in discrepancies between measured and calculated dose. These discrepancies are due to beam attenuation by the treatment couch that is not included in dose calculation. This work evaluates effects of accounting for this attenuation on patient specific VMAT QA results using an in-house created Varian Exact couch model in Pinnacl Methods: Patient specific VMAT QA results for 13 Pinnacle SmartArc plans generated for treatment on a Varian iX accelerator were studied. These plans included 3 treatment sites (7 H'N, 5 brain, 1 prostate). A Pinnacle model for Varian Exact couch was created in-house to replace the CT simulator couch. Composite arc planar doses were calculated with no couch present (NC) and with the Exact couch model (CM) in place for each plan. QA measurements were taken using IBA Matrixx Evolution ion chamber array set up in IBA MultiCube and were compared to each planar dose. Gamma passing criteria of both 3%/3mm and 2%/2mm tolerances were used. Results: Over all treatment sites, increases in gamma passing rates from NC to CM ranged from -0.4% to +27.3% at 3%/3mm and +0.1% to +30.5% at 2%/2mm. Mean increases in passing rates were +3.7% and +5.3% for 3%/3mm and 2%/2mm tolerances, respectively. Site-specific mean increases (NC to CM) in gamma passing rates were +4.4%, +3.4%, +0.4% (3%/3mm tolerance) and +6.9%, +3.7%, and +2.9% at (2%/2mm tolerance) for H'N, brain, and prostate, respectively. Conclusion: Results support use of a couch model when generating planar dose for patient specific VMAT QA analysis. The improvements were most noticeable at 2%/2mm tolerance and for the H'N and brain sites. Eliminating treatment couch beam attenuation as a source of discrepancy in QA measurements may improve the ability to recognize otherwise masked delivered dose errors.

60 APPLIED LIFE SCIENCES↗

SU-F-T-300: Impact of Electron Density Modeling of ArcCHECK Cylindricaldiode Array On 3DVH Patient Specific QA Software Tool Analysis

Purpose: 3DVH software is a patient specific quality assurance tool which estimates the 3D dose to the patient specific geometry with the help of Planned Dose Perturbation algorithm. The purpose of this study is to evaluate the impact of HU value of ArcCHECK phantom entered in Eclipse TPS on 3D dose & DVH QA analysis. Methods: Manufacturer of ArcCHECK phantom provides CT data set of phantom & recommends considering it as a homogeneous phantom with electron density (1.19 gm/cc or 282 HU) close to PMMA. We performed this study on Eclipse TPS (V13, VMS) & trueBEAM STx VMS Linac & ArcCHECK phantom (SNC). Plans were generated for 6MV photon beam, 20cm×20cm field size at isocentre & SPD (Source to phantom distance) of 86.7 cm to deliver 100cGy at isocentre. 3DVH software requires patients DICOM data generated by TPS & plan delivered on ArcCHECK phantom. Plans were generated in TPS by assigning different HU values to phantom. We analyzed gamma index & the dose profile for all plans along vertical down direction of beam’s central axis for Entry, Exit & Isocentre dose. Results: The global gamma passing rate (2% & 2mm) for manufacturer recommended HU value 282 was 96.3%. Detector entry, Isocentre & detector exit Doses were 1.9048 (1.9270), 1.00(1.0199) & 0.5078(0.527) Gy for TPS (Measured) respectively.The global gamma passing rate for electron density 1.1302 gm/cc was 98.6%. Detector entry, Isocentre & detector exit Doses were 1.8714 (1.8873), 1.00(0.9988) & 0.5211(0.516) Gy for TPS (Measured) respectively. Conclusion: Electron density value assigned by manufacturer does not hold true for every user. Proper modeling of electron density of ArcCHECK in TPS is essential to avoid systematic error in dose calculation of patient specific QA.

60 APPLIED LIFE SCIENCES↗

GridPACK Toolkit for Developing Power Grid Simulations on High Performance Computing Platforms

This paper describes the GridPACK™ framework, which is designed to help power grid engineers develop modeling software capable of running on todays high performance computers. The framework contains modules for setting up distributed power grid networks, assigning buses and branches with arbitrary behaviors to the network, creating distributed matrices and vectors, using parallel linear and non-linear solvers to solve algebraic equations, and mapping functionality to create matrices and vectors based on properties of the network. In addition, the framework contains additional functionality to support IO and to manage errors.

Palmer, Bruce J.↗