Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

A turbulent transport network model in MULTIFLUX coupled with TOUGH2

A new numerical method is described for the fully iterated, conjugate solution of two discrete submodels, involving (a) a transport network model for heat, moisture, and airflows in a high-permeability, air-filled cavity; and (b) a variably saturated fractured porous medium. The transport network submodel is an integrated-parameter, computational fluid dynamics solver, describing the thermal-hydrologic transport processes in the flow channel system of the cavity with laminar or turbulent flow and convective heat and mass transport, using MULTIFLUX. The porous medium submodel, using TOUGH2, is a solver for the heat and mass transport in the fractured rock mass. The new model solution extends the application fields of TOUGH2 by integrating it with turbulent flow and transport in a discrete flow network system. We present demonstrational results for a nuclear waste repository application at Yucca Mountain with the most realistic model assumptions and input parameters including the geometrical layout of the nuclear spent fuel and waste with variable heat load for the individual containers. The MULTIFLUX and TOUGH2 model elements are fully iterated, applying a programmed reprocessing of the Numerical Transport Code Functionalization model-element in an automated Outside Balance Iteration loop. The natural, convective airflow field and the heat and mass transport in a representative emplacement drift during postclosure are explicitly solved in the new model. The results demonstrate that the direction and magnitude of the air circulation patterns and all transport modes are strongly affected by the heat and moisture transport processes in the surrounding rock, justifying the need for a coupled, fully iterated model solution such as the one presented in the paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scalable Computation of Streamlines on Very Large Datasets

nderstanding vector fields resulting from large scientific simulations is an important and often difficult task. Streamlines, curves that are tangential to a ve ctor field at each point, are a powerful visualization method in this context. Application of streamline-based visualization to very large vector field data repr esents a significant challenge due to the non-local and data-dependent nature of streamline computation, and requires careful balancing of computational demands placed on I/O, memory, communication, and processors. In this paper we review two parallelization approaches based on established parallelization paradigms (stat ic decomposition and on-demand loading) and present a novel hybrid algorithm for computing streamlines. Our algorithm is aimed at good scalability and performanc e across the widely varying computational characteristics of streamline-based problems. We perform performance and scalability studies of all three algorithms on a number of prototypical application problems and demonstrate that our hybrid scheme is able to perform well in different settings.

Pugmire, Dave↗

Evaluating SWAT + model uncertainties for human and natural outcomes: Application in a Great Lakes agricultural watershed

Nutrient exports from agricultural lands in the Great Lakes Region pose significant threats to water quality and ecological health through eutrophication, hypoxia, and harmful algal blooms. Climate change and agricultural adaptation practices complicate future nutrient loading due to intensified hydrologic cycles and land use decisions. Our research focuses on evaluating the Soil and Water Assessment Tool (SWAT) plus model parametric uncertainties for human and natural outcomes across different scales. These factors are integral to ensuring a balance between productive agricultural practices and maintaining the health of watershed hydrology. However, uncertainties in modeling such complex interactions pose significant challenges, limiting our ability to precisely determine critical factors that influence crop yield and soil moisture. Our analysis employs Sobol global sensitivity analysis to evaluate first-order, second order, and total-order indices for SWAT crop growth parameter, ensuring comprehensive assessment of individual and interactive effects on model outputs. The objective is to identify the parameters that significantly affect model outputs for crop yield and soil moisture and improve our understanding of their interactions at the basin and hydrological response unit (HRU) scale. Our case study, the Portage River Watershed, which drains into Lake Erie, is chosen to better capture finer scale interactions crucial for predicting nutrient loading under future climate scenarios. This foundational work is aimed at setting the stage for the future development of an agent-based model (ABM). The ABM model would incorporate SWAT outputs to dynamically simulate decision-making processes.

Bunyon, Enock↗

Techno-Economic Analysis of a Secondary Air Stripper Process

We present results of an initial techno-economic assessment on a post-combustion CO2 capture process developed by the Center for Applied Energy Research (CAER) at the University of Kentucky using Mitsubishi Hitachi Power Systems’ H3-1 aqueous amine solvent. The analysis is based on data collected at a 0.7 MWe pilot unit combined with laboratory data and process simulations. The process adds a secondary air stripper to a conventional solvent process, which increases the cyclic loading of the solvent in two ways. First, air strips additional CO2 from the solvent downstream of the conventional steam-heated thermal stripper. This extra stripping of CO2 reduces the lean loading entering the absorber. Second, the CO2-enriched air is then sent to the boiler for use as secondary air. This recycling of CO2 results in a higher concentration of CO2 in the flue gas sent to the absorber, and hence a higher rich loading of the solvent exiting the absorber. A process model was incorporated into a full-scale supercritical pulverized coal power plant model to determine the plant performance and heat and mass balances. The performance and heat and mass balance data were used to size equipment and develop cost estimates for capital and operating costs. Lifecycle costs were considered through a levelized cost of electricity (LCOE) assessment based on the capital cost estimate and modeled performance. The results of the simulations show that the CAER process yields a regeneration energy of 3.12 GJ/t CO2, a $53.05/t CO2 capture cost, and LCOE of $174.59/MWh. This compares to the U.S. Department of Energy’s projected costs (Case 10) of regeneration energy of 3.58 GJ/t CO2 , a $61.31/t CO2 capture cost, and LCOE of $189.59/MWh. For H3-1, the CAER process results in a regeneration energy of 2.62 GJ/tCO2 with a stripper pressure of 5.2 bar, a capture cost of $46.93/t CO2, and an LCOE of $164.33/MWh.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Synthesis-Structure-Performance Correlation for Polyaniline-Me-C Non-Precious Metal Cathode Catalysts for Oxygen Reduction in Fuel Cells

In this report, we present the systematic preparation of active and durable non-precious metal catalysts (NPMCs) for the oxygen reduction reaction in polymer electrolyte fuel cells (PEFCs) based on the heat treatment of polyaniline/metal/carbon precursors. Variation of the synthesis steps, heat-treatment temperature, metal loading, and the metal type in the synthesis leads to markedly different catalyst activity, speciation, and morphology. Microscopy studies demonstrate notable differences in the carbon structure as a function of these variables. Balancing the need to increase the catalyst's degree of graphitization through heat treatment versus the excessive loss of surface area that occurs at higher temperatures is a key to preparing an active catalyst. XPS and XAFS spectra are consistent with the presence of Me-N{sub x} structures in both the Co and Fe versions of the catalyst, which are often proposed to be active sites. The average speciation and coordination environment of nitrogen and metal, however, depends greatly on the choice of Co or Fe. Taken together, the data indicate that better control of the metal-catalyzed transformations of the polymer into new graphitized carbon forms in the heat-treatment step will allow for even further improvement of this class of catalysts.

30 DIRECT ENERGY CONVERSION↗

Optical measurement of Cs distribution in the large negative ion source

To investigate a Cs behavior, optical diagnostic tools have been installed in the large negative ion source, an arc discharge used at large helical device neutral beam injector. A large Cs sputtering is observed during beam extraction due to the backstreaming H{sup +} ions. Distribution of Cs{sup +} light is uniform in the case of a balanced arc discharge, but large increase of Cs{sup +} light during beam extraction is observed in a nonuniform arc discharge. Controlling of the discharge uniformity is effective to reduce the local heat loading from the backstreaming H{sup +} ions at the backplate of ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Boil-off losses along LH2 pathway

Losses along the LH 2 pathway are intrinsic to the utilization of a cryogenic fluid. They occur when the molecule is transferred between 2 vessels (liquefaction plant to trailer, trailer to station storage, station storage to pump or compressor, then fuel cell electric vehicles …) and when the fluid is warmed up due to heat transfer with the environment. Those losses can be estimated with good accuracy using thermodynamic models based on conservation of mass and energy, providing the thermodynamic states are correctly described. Indeed, the fluid undergoes various changes as it moves along the entire pathway (2 phase transition, super-heated warming, non-uniform temperature distributions across the saturation film) and accurate equations of state and 2 phase behavior implementations are essential. The balances of mass and energy during the various dynamics processes then enable to quantify the boil-off losses. In this work, a MATLAB code previously developed by NASA to simulate rocket loading is used as the basis for the LH 2 transfer model. This code implements complex physical phenomena such as the competition between condensation and evaporation and the convection vs. conduction heat transfer as a function of the relative temperatures on both sides of the saturated film. The original code was modified to consider real gas equations of state, and some semi-empirical relationships, such as between the heat of vaporization and the critical temperature, were also replaced by a REFPROP equivalent expression, assumed to be more accurate. Non-constant liquid temperature equations were added to simulate sub-cooled conditions. It is shown that although trailer depressurization and transfer losses from the receiving vessel during a LH 2 delivery may constitute the largest sources of losses, those can be greatly reduced and even eliminated if CFR/DOT regulations are properly applied and if no-vent fill methods are implemented, particularly for a stationary LH2 storage operating at reasonably low pressure (45 psia or so). As such, it is expected that the only remaining boil-off losses for a refueling station would come from the LH 2 pump (utilization and idling), pump vessel cool down/warm up, and environment heat transfer. Based on experimental data measured at LLNL on the Linde 875 bar LH 2 cryo-pump and results from the model, and extrapolating for refueling stations of various sizes, it can be shown that boil-off losses can vary from 15% of delivered LH 2 for a 100 kg/day, 5% at 400 kg/day, and down to less than 2% for stations above 1,800 kg/day (for a system similar to the one at LLNL). Less boil-off is to be expected for LH 2 pumps dispensing at 350 bar, so that less than 0.7% can be expected above 1,800 kg/day station capacities. At last, boil-off recovery solutions are briefly analyzed, including compressors, cryo-coolers and stationary fuel cell. Their economic value is strongly related to the costs of H2 and of the electricity needed to perform the recovery, on top of the initial capital expenditures. Effective boil-off could be reduced to 0.6-1% for a 2,000 kg/day station if adequate recovery solutions are used.

08 HYDROGEN↗

A Serially-Connected Compensator for Eliminating the Unbalanced Three-Phase Voltage Impact on Wind Turbine Generators

Untransposed transmission lines, unbalanced tap changer operations, and unbalanced loading in weak distribution lines can cause unbalanced-voltage conditions. The resulting unbalanced voltage at the point of interconnection affects proper gird integration and reduces the lifetime of wind turbines due to power oscillations, torque pulsations, mechanical stresses, energy losses, and uneven and overheating of the generator stator winding. This work investigates the dynamic impact of unbalanced voltage on the mechanical and electrical components of integrated Fatigue, Aerodynamics, Structures, and Turbulence (FAST) wind turbine generation systems (WTGs) of Type 1 (squirrel-cage induction generator) and Type 3 (doubly-fed induction generator). To alleviate this impact, a serially-connected compensator for a three-phase power line is proposed to balance the wind turbine-side voltage. Dynamic simulation studies are conducted in MATLAB/Simulink to compare the responses of these two types of wind turbine models under normal and unbalanced-voltage operation conditions and demonstrate the effectiveness of the proposed compensator.

17 WIND ENERGY↗

Combined Experimental and Numerical Investigation of Lightcraft no. 200 Aerodynamics at Mach 3

The combined experimental and numerical research study investigated the supersonic aerodynamics of a Type 200 laser lightcraft at Mach 3 and {approx}18 km altitude. Several 1 inch (2.54 cm) and 1.25 inch (3.175 cm) diameter lightcraft models with 'closed' axisymmetric inlets were machined from 6061-T6 aluminum and tested in RPI's vacuum-driven Mach 3 wind tunnel. Schlieren photographs were taken of the unpowered models in both axial- and lateral-flight (i.e., 'Frisbee' mode) directions, then compared and contrasted with CFD predictions using Fluent registered . One 1.25 inch axial flight model was fitted with a piezoelectric load cell to measure axial drag forces. Preliminary measurements of aerodynamic lift forces in the lateral flight mode were recorded as a function of angle of attack, using a special strain guage sting balance with an adjustable elbow. The bow shock structure captured in Schlieren photographs correlated well with CFD simulations, as well as with shockwave theory for common conical noses. In these axial flight model tests, slight differences were noted between the Schlieren photos and CFD density contour plots, especially with regard to the secondary shock structure; CFD results predicted these shocks closer to the shroud than nature would have it.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real sample temperature: a critical issue in the experiments of nuclear resonant vibrational spectroscopy on biological samples

There are several practical and intertangled issues which make the experiments of nuclear resonant vibrational spectroscopy (NRVS) on biological samples difficult to perform. The sample temperature is one of the most important issues. In NRVS the real sample temperatures can be very different from the readings on the temperature sensors. In this study the following have been performed: (i) citing and analyzing various existing NRVS data to assess the real sample temperatures during the NRVS measurements and to understand their trends with the samples’ loading conditions; (ii) designing several NRVS measurements with (Et 4 N)[FeCl 4 ] to verify these trends; and (iii) proposing a new sampleloading procedure to achieve significantly lower real sample temperatures and to balance among the intertangled experimental issues in biological NRVS measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Status of development of the Small Secure Transportable Autonomous Reactor (SSTAR) for worldwide sustainable nuclear energy supply.

Significant progress and improvements have been made on development of a pre-conceptual design of the Secure Transportable Autonomous Reactor (SSTAR) Lead-Cooled Fast Reactor (LFR) concept since it was last reported on at ICAPP 05. SSTAR is a small, 20 MWe (45 MWt), exportable, natural circulation, fast reactor plant concept incorporating proliferation resistance for deployment in non-fuel cycle states and developing nations, fissile self-sufficiency for efficient utilization of uranium resources, autonomous load following making it suitable for small or immature grid applications, and a high degree of passive safety. Customers of SSTAR include: (1) clients looking for energy security at small capital outlay; (2) cities in developing nations; and (3) deregulated independent power producers in developed nations. The SSTAR pre-conceptual design integrates three major features: primary coolant natural circulation heat transport; lead (Pb) coolant; and transuranic nitride fuel in a pool vessel configuration. The Pb coolant flows upward through the core which is an open-lattice of large-diameter (2.5 centimeter) fuel pins containing transuranic nitride pellets clad bonded with liquid Pb to silicon-enhanced ferritic/martensitic (F/M) stainless steel arranged on a triangular pitch with spacing maintained by grid spacers; the core does not incorporate removable fuel assemblies as one means of restricting access to the fuel. The whole core is a single removable assembly with a long lifetime (30 years) at which time refueling equipment is brought onsite. Conversion of the core thermal energy to electricity is accomplished using a supercritical carbon dioxide (S-CO{sub 2}) Brayton cycle energy converter providing higher plant efficiencies and lower balance of plant costs than the traditional Rankine steam cycle operating at the same reactor core outlet temperature. A control strategy has been developed for automatic control of the S-CO{sub 2} Brayton cycle in principle enabling autonomous load following over the full power range between nominal and essentially zero power whereby the reactor core power adjusts itself to the heat removal from the reactor system to the power converter through the large reactivity feedback of the fast spectrum core without the need for motion of control rods, while the automatic control of the power converter matches the heat removal from the reactor to the grid load. A safety design approach has been formulated for SSTAR based upon defense-in-depth providing multiple levels of protection against the release of radioactive materials. The inherent safety features of the lead coolant (T{sub boil} = 1740 C, lack of chemical reaction of Pb with the CO{sub 2} working fluid, low absorption of neutrons by Pb, and the heavy Pb), nitride fuel (high thermal conductivity, transuranic nitride decomposition temperature {approx} 1300 C, compatibility with cladding, low volumetric swelling and fission gas release), fast neutron spectrum core, pool vessel configuration, natural circulation, and containment enable the requirements for each level of protection to be readily met or exceeded. The interest in higher plant efficiencies has heretofore driven interest in operation of SSTAR at higher Pb temperatures to take advantage of the increase in plant efficiency with temperature of the S-CO{sub 2} Brayton cycle. A peak cladding temperature of 650 C has been used as a goal; at this temperature, a reactor core outlet temperature of 564 C is achieved resulting in a Brayton cycle efficiency of 44.2 % and a net plant efficiency of 43.8 %. It has always been recognized that this would require the development of cladding and structural materials for long-term service in Pb coolant up to 650 C peak cladding temperature with corrosion protection provided by active maintenance and control of the dissolved oxygen potential in the coolant giving rise to the formation of protective oxide layers on the steel cladding and structures. SSTAR development has been supported by the testing in the DELTA loop at Los Alamos National Laboratory of alloy specimens with special treatments or coatings which might enhance corrosion resistance at the temperatures at which SSTAR operates. The focus of LFR development in the U.S. is now shifting towards the development of a near-term deployable LFR test demonstrator and a near-term deployable small exportable LFR. Both reactors would operate at lower temperatures enabling the use of existing materials such as T91 or HT9 F/M stainless steel that is already incorporated into the ASME codes and have been shown to have corrosion resistance to lead-bismuth eutectic with active oxygen control at temperatures below about 550 C in experiments carried out in the DELTA loop and elsewhere.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗

Digital Real-Time Simulation and Power Quality Analysis of a Hydrogen-Generating Nuclear-Renewable Integrated Energy System

This paper investigates the challenges and solutions associated with integrating a hydrogen-generating nuclear-renewable integrated energy system (NR-IES) under a transactive energy framework. The proposed system directs excess nuclear power to hydrogen production during periods of low grid demand while utilizing renewables to maintain grid stability. Using digital real-time simulation (DRTS) in the Typhoon HIL 404 model, the dynamic interactions between nuclear power plants, electrolyzers, and power grids are analyzed to mitigate issues such as harmonic distortion, power quality degradation, and low power factor caused by large non-linear loads. A three-phase power conversion system is modeled using the Typhoon HIL 404 model and includes a generator, a variable load, an electrolyzer, and power filters. Active harmonic filters (AHFs) and hybrid active power filters (HAPFs) are implemented to address harmonic mitigation and reactive power compensation. The results reveal that the HAPF topology effectively balances cost efficiency and performance and significantly reduces active filter current requirements compared to AHF-only systems. During maximum electrolyzer operation at 4 MW, the grid frequency dropped below 59.3 Hz without filtering; however, the implementation of power filters successfully restored the frequency to 59.9 Hz, demonstrating its effectiveness in maintaining grid stability. Future work will focus on integrating a deep reinforcement learning (DRL) framework with real-time simulation and optimizing real-time power dispatch, thus enabling a scalable, efficient NR-IES for sustainable energy markets.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Providing Reliability Services through Demand Response: A Prelimnary Evaluation of the Demand Response Capabilities of Alcoa Inc.

Demand response is the largest underutilized reliability resource in North America. Historic demand response programs have focused on reducing overall electricity consumption (increasing efficiency) and shaving peaks but have not typically been used for immediate reliability response. Many of these programs have been successful but demand response remains a limited resource. The Federal Energy Regulatory Commission (FERC) report, 'Assessment of Demand Response and Advanced Metering' (FERC 2006) found that only five percent of customers are on some form of demand response program. Collectively they represent an estimated 37,000 MW of response potential. These programs reduce overall energy consumption, lower green house gas emissions by allowing fossil fuel generators to operate at increased efficiency and reduce stress on the power system during periods of peak loading. As the country continues to restructure energy markets with sophisticated marginal cost models that attempt to minimize total energy costs, the ability of demand response to create meaningful shifts in the supply and demand equations is critical to creating a sustainable and balanced economic response to energy issues. Restructured energy market prices are set by the cost of the next incremental unit of energy, so that as additional generation is brought into the market, the cost for the entire market increases. The benefit of demand response is that it reduces overall demand and shifts the entire market to a lower pricing level. This can be very effective in mitigating price volatility or scarcity pricing as the power system responds to changing demand schedules, loss of large generators, or loss of transmission. As a global producer of alumina, primary aluminum, and fabricated aluminum products, Alcoa Inc., has the capability to provide demand response services through its manufacturing facilities and uniquely through its aluminum smelting facilities. For a typical aluminum smelter, electric power accounts for 30% to 40% of the factory cost of producing primary aluminum. In the continental United States, Alcoa Inc. currently owns and/or operates ten aluminum smelters and many associated fabricating facilities with a combined average load of over 2,600 MW. This presents Alcoa Inc. with a significant opportunity to respond in areas where economic opportunities exist to help mitigate rising energy costs by supplying demand response services into the energy system. This report is organized into seven chapters. The first chapter is the introduction and discusses the intention of this report. The second chapter contains the background. In this chapter, topics include: the motivation for Alcoa to provide demand response; ancillary service definitions; the basics behind aluminum smelting; and a discussion of suggested ancillary services that would be particularly useful for Alcoa to supply. Chapter 3 is concerned with the independent system operator, the Midwest ISO. Here the discussion examines the evolving Midwest ISO market structure including specific definitions, requirements, and necessary components to provide ancillary services. This section is followed by information concerning the Midwest ISO's classifications of demand response parties. Chapter 4 investigates the available opportunities at Alcoa's Warrick facility. Chapter 5 involves an in-depth discussion of the regulation service that Alcoa's Warrick facility can provide and the current interactions with Midwest ISO. Chapter 6 reviews future plans and expectations for Alcoa providing ancillary services into the market. Last, chapter 7, details the conclusion and recommendations of this paper.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation of annual biogeochemical cycles of nutrient balance, phytoplankton bloom(s), and DO in Puget Sound using an unstructured grid model

Nutrient pollution from rivers, nonpoint source runoff, and nearly 100 wastewater discharges is a potential threat to the ecological health of Puget Sound with evidence of hypoxia in some basins. However, the relative contributions of loads entering Puget Sound from natural and anthropogenic sources, and the effects of exchange flow from the Pacific Ocean are not well understood. Development of a quantitative model of Puget Sound is thus presented to help improve our understanding of the annual biogeochemical cycles in this system using the unstructured grid Finite-Volume Coastal Ocean Model framework and the Integrated Compartment Model (CE-QUAL-ICM) water quality kinetics. Results based on 2006 data show that phytoplankton growth and die-off, succession between two species of algae, nutrient dynamics, and dissolved oxygen in Puget Sound are strongly tied to seasonal variation of temperature, solar radiation, and the annual exchange and flushing induced by upwelled Pacific Ocean waters. Concentrations in the mixed outflow surface layer occupying approximately 5–20 m of the upper water column show strong effects of eutrophication from natural and anthropogenic sources, spring and summer algae blooms, accompanied by depleted nutrients but high dissolved oxygen levels. The bottom layer reflects dissolved oxygen and nutrient concentrations of upwelled Pacific Ocean water modulated by mixing with biologically active surface outflow in the Strait of Juan de Fuca prior to entering Puget Sound over the Admiralty Inlet. The effect of reflux mixing at the Admiralty Inlet sill resulting in lower nutrient and higher dissolved oxygen levels in bottom waters of Puget Sound than the incoming upwelled Pacific Ocean water is reproduced. Finally, by late winter, with the reduction in algal activity, water column constituents of interest, were renewed and the system appeared to reset with cooler temperature, higher nutrient, and higher dissolved oxygen waters from the Pacific Ocean.

biogeochemical model, 3-D hydrodynamic model, nutr↗

On Line Enrichment Monitor (OLEM) UF 6 Tests for 1.5" Sch40 SS Pipe, Revision 1

As global uranium enrichment capacity under international safeguards expands, the International Atomic Energy Agency (IAEA) is challenged to develop effective safeguards approaches at gaseous centrifuge enrichment plants while working within budgetary constraints. The “Model Safeguards Approach for Gas Centrifuge Enrichment Plants” (GCEPs) developed by the IAEA Division of Concepts and Planning in June 2006, defines the three primary Safeguards objectives to be the timely detection of: 1) diversion of significant quantities of natural (NU), depleted (DU) or low-enriched uranium (LEU) from declared plant flow, 2) facility misuse to produce undeclared LEU product from undeclared feed, and 3) facility misuse to produce enrichments higher than the declared maximum, in particular, highly enriched uranium (HEU). The ability to continuously and independently (i.e. with a minimum of information from the facility operator) monitor not only the uranium mass balance but also the 235 U mass balance in the facility could help support all three verification objectives described above. Two key capabilities required to achieve an independent and accurate material balance are 1) continuous, unattended monitoring of in-process UF 6 and 2) monitoring of cylinders entering and leaving the facility. The continuous monitoring of in-process UF 6 would rely on a combination of load-cell monitoring of the cylinders at the feed and withdrawal stations, online monitoring of gas enrichment, and a high-accuracy net weight measurement of the cylinder contents. The Online Enrichment Monitor (OLEM) is the instrument that would continuously measure the time-dependent relative uranium enrichment, E(t), in weight percent 235 U, of the gas filling or being withdrawn from the cylinders. The OLEM design concept combines gamma-ray spectrometry using a collimated NaI(Tl) detector with gas pressure and temperature data to calculate the enrichment of the UF 6 gas within the unit header pipe as a function of time. The OLEM components have been tested on ORNL UF 6 flow loop. Data were collected at five different enrichment levels (0.71%, 2.97%, 4.62%, 6.0%, and 93.7%) at several pressure conditions. The test data were collected in the standard OLEM N.4242 file format for each of the conditions with a 10-minute sampling period and then averaged over the span of constant pressures. Analysis of the collected data has provided enrichment constants that can be used for 1.5” stainless steel schedule 40 pipe measurement sites. The enrichment constant is consistent among all the wide range of enrichment levels and pressures used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ITER ICH Transmission Line and Matching System Prototype Development

Design and testing of prototype components for the ITER Ion Cyclotron Heating (ICH) transmission line and matching system is underway. Each ICH transmission line is designed to handle up to 6 MW/line in the 40–55 MHz frequency range. A total of 8 lines split to 16 antenna inputs on two ICH antennas. The ICH system is made up of 14 types of unique coaxial transmission line and matching components. The matching system is designed to provide passive ELM tolerance through the use of hybrid couplers and loads, which can absorb the transient reflected power. In addition the system is designed to compensate for coupling between antenna inputs caused by the mutual inductances of the current straps. It is further designed to balance as much as reasonable, the power requirements from the sources and the peak voltages on the antenna array elements.

42 ENGINEERING↗