Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Suppression of Dynamic Stall by Steady and Pulsed Upper-Surface Blowing

The Boeing-Vertol VR-7 airfoil was experimentally studied with steady and pulsed upper-surface blowing for sinusoidal pitching oscillations described by alpha = alpha(sub m) + 10 deg sin(omega t). The tests were conducted in the U.S. Army Aeroflightdynamics Directorate's Water Tunnel at NASA Ames Research Center. The experiment was performed at a Reynolds number of 100,000. Pitch oscillations with alpha(sub m) = 10 deg and 15 deg and with reduced frequencies ranging from k = 0.005 to 0.15 were examined. Blowing conditions ranged from C(sub mu) = 0.03 to 0.66 and F(+) = 0 to 3. Unsteady lift, drag, and pitching-moment loads were measured, and fluorescent-dye flow visualizations were obtained. Steady, upper-surface blowing was found to be capable of trapping a separation bubble near the leading edge during a portion of the airfoil's upward rotation. When this occurred, the lift was increased significantly and stall was averted. In all cases, steady blowing reduced the hysteresis amplitudes present in the loads and produced a large thrust force. The benefits of steady blowing diminished as the reduced frequency and mean angle of oscillation increased. Pulsed blowing showed only marginal benefits for the conditions tested. The greatest gains from pulsed blowing were achieved at F(+) = 0.9.

Weaver, D.↗

Effects of blade loading and rotation on compressor rotor wake in end wall regions

This study was carried out to understand the effects of blade loading and rotation on the rotor end wall flow structure, including the wake. The measurements were taken with a stationary three sensor hot wire located at the exit of a compressor rotor. The signal was ensemble averaged to derive all the three components of velocity and six components of stresses at the exit. Measurements were made at two different rotational speeds (1753 and 1010 rpm) and at two differing blade loadings at several radii near the hub and the annulus wall. The wake decay in the annulus wall region is found to be much more rapid than the mid span regions. Furthermore, both the loading and rotation of the blade have appreciable influence on the end wall flow and wake structure. Interaction of the annulus and hub wall boundary layers (and secondary flow resulting from these) have appreciable influence on the wake structure in the endwall regions.

Lakshminarayana, B.↗

U(VI) Sorption and Reduction Kinetics on the Magnetite (111) Surface

Sorption of contaminants onto mineral surfaces is an important process that can restrict their transport in the environment. In the current study, uranium (U) uptake on magnetite (111) was measured as a function of time and solution composition (pH, [CO 3 ]T, [Ca]) under continuous batch-flow conditions. We observed, in real-time and in situ, adsorption and reduction of U(VI) and subsequent growth of UO 2 nanoprecipitates using atomic force microscopy (AFM) and newly developed batch-flow U LIII-edge grazing-incidence X-ray absorption spectroscopy near-edge structure (GI-XANES) spectroscopy. U(VI) reduction occurred with and without CO 3 present, and coincided with nucleation and growth of UO 2 particles. When Ca and CO 3 were both present no U(VI) reduction occurred and the U surface loading was lower. In situ batch-flow AFM data indicated that UO 2 particles achieved a maximum height of 4–5 nm after about 8 h of exposure, however, aggregates continued to grow laterally after 8 h reaching up to about 300 nm in diameter. The combination of techniques indicated that U uptake is divided into three-stages; (1) initial adsorption of U(VI), (2) reduction of U(VI) to UO 2 nanoprecipitates at surface-specific sites after 2–3 h of exposure, and (3) completion of U(VI) reduction after ~6–8 h. U(VI) reduction also corresponded to detectable increases in Fe released to solution and surface topography changes. Redox reactions are proposed that explicitly couple the reduction of U(VI) to enhanced release of Fe(II) from magnetite. Although counterintuitive, the proposed reaction stoichiometry was shown to be largely consistent with the experimental results. In addition to providing molecular-scale details about U sorption on magnetite, this work also presents novel advances for collecting surface sensitive molecular-scale information in real-time under batch-flow conditions.

54 ENVIRONMENTAL SCIENCES↗

Unsteady design-point flow phenomena in transonic compressors

High-frequency response probes which had previously been used exclusively in the MIT Blowndown Facility were successfully employed in two conventional steady state axial flow compressor facilities to investigate the unsteady flowfields of highly loaded transonic compressors at design point operation. Laser anemometry measurements taken simultaneously with the high response data were also analyzed. The time averaged high response data of static and total pressure agreed quite well with the conventional steady state instrumentation except for flow angle which showed a large spread in values at all radii regardless of the type of instrumentation used. In addition, the time resolved measurements confirmed earlier test results obtained in the MIT Blowdown Facility for the same compressor. The results of these tests have further revealed that the flowfields of highly loaded transonic compressors are heavily influenced by unsteady flow phenomena. The high response measurements exhibited large variations in the blade to blade flow and in the blade passage flow. The observed unsteadiness in the blade wakes is explained in terms of the rotor blades' shed vorticity in periodic vortex streets. The wakes were modeled as two-dimensional vortex streets with finite size cores. The model fit the data quite well as it was able to reproduce the average wake shape and bi-modal probability density distributions seen in the laser anemometry data. The presence of vortex streets in the blade wakes also explains the large blade to blade fluctuations seen by the high response probes which is simply due to the intermittent sampling of the vortex street as it is swept past a stationary probe.

Gertz, J. B.↗

Flow Strength Measurements of Wrought and AM SS304L via Pressure Shear Plate Impact Experiments

Pressure-shear plate impact experiments were performed to quantify flow strength of wrought, as-built additively manufactured (AM), and heat-treated and recrystallized AM 304 L stainless steel (SS304L) under combined loading. Impact velocities spanned between 0.03 and 0.24 mm/μs, resulting in corresponding pressures of 0.62–5.93 GPa. Flow strength measurements are comparable for the sample variants across the studied loading conditions; however, shear wave structures significantly differ between sample type. Microstructurally aware simulations indicate local strain differences attributed to anisotropic elastic constants of large grains (~1 mm) in the as-built and heat-treated AM may impede the ability to uniformly transmit a shear wave.

36 MATERIALS SCIENCE↗

Production of Cool Gas in Thermally Driven Outflows

Galactic outflows commonly contain multiphase gas, and its physical origin requires explanation. Using the Cholla Galactic OutfLow Simulations suite of high-resolution isolated galaxy models, we demonstrate the viability of rapid radiative cooling as a source of fast-moving ( v ~ 1000 km s -1 ), cool (10 4 K) gas observed in absorption-line studies of outflows around some star-forming galaxies. By varying the mass loading and geometry of the simulated winds, we identify a region of parameter space that leads to cool gas in outflows. In particular, when using an analytically motivated central feedback model, we find that cooling flows can be produced with reasonable mass-loading rates (${\dot{M}}_{\mathrm{wind}}/{\dot{M}}_{\mathrm{SFR}}\sim 0.5$), provided that the star formation rate surface density is high. When a more realistic clustered feedback model is applied, destruction of high-density clouds near the disk and interactions between different outflow regions indicate that lower mass-loading rates of the hot gas within the feedback region may still produce multiphase outflows. These results suggest an origin for fast-moving cool gas in outflows that does not rely on directly accelerating cool gas from the interstellar medium. Finally, these cooling flows may additionally provide an explanation for the multiphase gas ubiquitously observed in the halos of star-forming galaxies at low redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical droplet vaporization of nanoparticle-loaded stimuli-responsive microbubbles

A capillary co-flow focusing process is developed to generate stimuli-responsive microbubbles (SRMs) that comprise perfluorocarbon (PFC) suspension of silver nanoparticles (SNPs) in a lipid shell. Upon continuous laser irradiation at around their surface plasmon resonance band, the SNPs effectively absorb electromagnetic energy, induce heat accumulation in SRMs, trigger PFC vaporization, and eventually lead to thermal expansion and fragmentation of the SRMs. This optical droplet vaporization (ODV) process is further simulated by a theoretical model that combines heat generation of SNPs, phase change of PFC, and thermal expansion of SRMs. The model is validated by benchtop experiments, where the ODV process is monitored by microscopic imaging. The effects of primary process parameters on behaviors of ODV are predicted by the theoretical model, indicating the technical feasibility for process control and optimization in future drug delivery applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal Load-Side Control for Frequency Regulation in Smart Grids

Frequency control rebalances supply and demand while maintaining the network state within operational margins. It is implemented using fast ramping reserves that are expensive and wasteful, and which are expected to become increasingly necessary with the current acceleration of renewable penetration. The most promising solution to this problem is the use of demand response, i.e., load participation in frequency control. Yet it is still unclear how to efficiently integrate load participation without introducing instabilities and violating operational constraints. In this paper, we present a comprehensive load-side frequency control mechanism that can maintain the grid within operational constraints. In particular, our controllers can rebalance supply and demand after disturbances, restore the frequency to its nominal value, and preserve interarea power flows. Furthermore, our controllers are distributed (unlike the currently implemented frequency control), can allocate load updates optimally, and can maintain line flows within thermal limits. We prove that such a distributed load-side control is globally asymptotically stable and robust to unknown load parameters. We illustrate its effectiveness through simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimation of Commodity Origin-Destination Matrices and Flows: The Network Tomography of U.S. Wheat Shipments

This study proceeds from the belief that an examination of railroads and railcar flows provides important insights into economic geography and to the economics of transportation. The flows of wheat in the United States are examined using rail carload waybill survey data in order to model the network routes likely taken from origin to destination, a characterization of the flows themselves, and modeling the flows through the comparison of standard gravity models with two relatively new gravity estimation methodologies suggested in the network analysis literature. The analysis covers Wheat flows through the U.S. for the years 2013 through 2015. Rail flows are highly conducive to the emergence of high volume corridors, a primary hypothetical relationship described by Taaffe, Morrill and Gould (1963). Hubs are expected to develop in market centers with sufficient traffic, as in a Christaller (1966) system, where market centers above a certain size have terminal facilities, or serve as primary interchange points. Centers of different sizes may also have more than one load center thereby concentrating and attracting more flows (o’Kelly, 1998). Implications are for commodity production and processing locations to develop concentrations of flows and the development of identifiable commodity-specific components of the national rail network. As the railroad nodes are structured in relation to the railroad network, the origin and destination nodes take the form of an irregular lattice (Besag 1974). One implication of this irregular lattice network is the probable presence of network autocorrelation in the flows: the constraints of network connectivity assure flows are not open between the terminals, but travel to and from distinct neighbors on the network. In addition, the network terminal structure can be expected to follow a hierarchical central place ordering. Evidence of such an ordering may be determined by examining the clustering and concentration of flows at nodes and, by association, particular network links serving those nodes (Fujita and Thisse 2002; Hesse and Rodrigue 2004; Nierat 1997). The presence of hierarchies implies economies of scale are being realized which leads to a centralizing or agglomerating effect (Fujita and Thisse, 2002 and Brakman et al, 2001). Thus the transportation sector will also develop an associated central place hierarchy with its own associated network of flows and flow concentrations.

Peterson, Steven↗

Investigation of Nonlinear Difference-Frequency Wave Excitation on a Semisubmersible Offshore-Wind Platform with Bichromatic-Wave CFD Simulations: Preprint

The natural surge and pitch frequencies of semisubmersible offshore wind platforms are typically designed to be below the wave frequencies to avoid direct excitation. However, surge or pitch resonance can be excited by the nonlinear low-frequency loads generated by irregular incident waves. Second-order potential-flow models with added Morison drag have been found to underpredict this low-frequency excitation and response. As part of the OC6 project, Computational Fluid Dynamics (CFD) simulations were performed to enable a better understanding of the low-frequency loads and the limitations of lower-fidelity models. The focus of the current paper is to set up a computationally cost-effective CFD simulation of a fixed semisubmersible platform to investigate nonlinear difference-frequency loads and establish the corresponding uncertainty in the results. Due to the high computing cost, CFD simulations of irregular waves can be challenging. Instead, simulations were performed with bichromatic waves having a shorter repeat period. A preliminary comparison with Quadratic Transfer Functions from second-order potential-flow theory shows that CFD models consistently predict higher nonlinear wave loads at the difference frequency, likely due to flow separation and viscous drag not accounted for in potential-flow theory.

2nd order↗

Novel Modular Heat Engines with sCO 2 Bottoming Cycle Utilizing Advanced Oil-Free Turbomachinery

This report presents the thermal, mechanical, and electric machine design of a 27krpm rotating test rig aimed at reducing technical risks with hermetic oil-free super-critical carbon dioxide (sCO 2 ) turbomachinery. The test rig rotor system is based on a conceptual turbomachine design discussed that evaluates a sCO 2 waste heat recovery (WHR) unit for land-based gas turbines at natural gas (NG) compressor stations. The key novelty of the hermetic sCO 2 turbomachine concept is the utilization of additively manufactured CO 2 gas bearings and a CO 2 -immersed direct-drive permanent magnet (PM) electric machine. The previous effort on conceptual design identified 3 main technical risks, which included thrust bearing load capacity, rotordynamics, and thermal performance of the system. Therefore, key requirements of the test vehicle include the ability to test the rotor system in a 400psi (27.6 bar) hermetic CO 2 operating environment, apply up to 1,500 lbs (6.7 kN) of rotor thrust loads, capability to assess rotordynamics with radial gas bearings, inclusion of instrumentation to assess thrust bearing load capability, and flexibility for varying secondary cooling flows to confirm thermal model predictions. Design topics such as rotordynamics, bearing design, and electric machine design are addressed, while highlighting critical elements. In addition, additive build trials for Inconel 718 radial and thrust bearings were performed to prove the manufacturability of the bearing design concepts. The results of the design efforts yield a test rig concept with ability to operate at 27,000 rpm, apply thrust loads to 1,500 lbs, deliver CO 2 up to 800psi, and modulate cooling flows.

03 NATURAL GAS↗

Understanding the impact of flow rate and recycle on the conversion of a complex biorefinery stream using a flow-through microbial electrolysis cell

We investigated the effect of flow rate and recycle on the conversion of a biomass-derived pyrolysis aqueous phase in amicrobial electrolysis cell (MEC) to demonstrate production of renewable hydrogen in biorefinery. A continuous MEC operation was investigated under one-pass and recycle conditions usingthe complex, biomass-derived, fermentable, mixed substrate feed at a constant concentration of 0.026 g/L,while testing flow rates ranging from 0.19 to 3.6 mL/min. This corresponds to an organic loading rate (OLR) of 0.54₋10 g/L-day. Mass transfer issues observed at low flow rates were alleviated using high flow rates.Increasing the flow rate to 3.6 mL/min (3.7 min HRT) during one-pass operation increased the hydrogen productivity 3-fold, but anode conversion efficiency (ACE) decreased from 57.9% to 9.9%. Recycle of the anode liquid helped to alleviate kinetic limitations and the ACE increased by 1.8-fold and the hydrogen productivity by 1.2-fold compared to the one-pass condition at the flow rate of 3.6 mL/min (10 g/L-d OLR). High COD removal was also achieved under recycle conditions, reaching 74.2 1.1%, with hydrogen production rate of 2.92 ± 0.51 L/L-day. This study demonstrates the advantages of combining faster flow rates with a recycle process to improve rate of hydrogen production from a switchgrass-derived stream in the biorefinery.

08 HYDROGEN↗

Mercury speciation driven by seasonal changes in a contaminated estuarine environment

In this study, seasonal changes of mercury (Hg) species in the highly variable estuary of Soča/Isonzo River (northern Adriatic Sea) were investigated. Samplings were performed on a seasonal basis (September 2009, May, August and October 2010) and Hg species (total Hg, methylmercury (MeHg), dissolved gaseous Hg (DGM)) in waters, sediments and pore waters were determined. In addition, a range of ancillary parameters were measured (salinity, nutrients, organic carbon (OC), nitrogen species). Hg values were interpreted using these parameters and hydrological conditions (river flow, wave height) around the time of sampling. There were no significant changes in Hg load from river to the gulf, compared to previous studies. The load was temporarily higher in May 2010 due to higher river flow. Wave height, through changing hydrostatic pressure, was most likely to cause resuspension of already deposited Hg from the bottom (August 2010). The estuary is a net source of DGM to the atmosphere as suggested by DGM profiles, with salinity, redox potential and organic matter as the most probable controls over its production. MeHg is produced in situ in sediment or in water column, rather than transported by river, as indicated by its correlation with OC of the marine origin. Calculated fluxes for THg and MeHg showed sediment as a source for both the water column. In pore waters, OC in part affects partitioning of both THg and MeHg; however other factors (e.g. sulphide and/or oxyhydroxides precipitation and dissolution) are also probably important. -- Highlights: ► Water, sediment and pore water mercury species in front of Soča River estuary were measured. ► Seasonally variable hydrological conditions were shown to influence water column Hg speciation. ► Fluxes for total Hg and MeHg from sediment to water were calculated. ► Sediment is a source of total Hg and MeHg to the water column. ► Correlation of MeHg with organic carbon of marine origin suggests in situ formation.

60 APPLIED LIFE SCIENCES↗

University of Hawai‘i, Shallow Geothermal Resources: Energy Technology Innovation Partnership Project (Final Report)

Scientists at Lawrence Berkeley National Laboratory (Berkeley Lab) have teamed up with the University of Hawai‘i at Manoa (UH Manoa) through the U.S. Department of Energy’s Energy Technology Innovation Partnership Project to evaluate the technological and market feasibility of shallow geothermal heat exchanger (GHE) technology. UH requested this analysis to evaluate opportunities in building cooling, energy efficiency, and emissions reduction applications in Hawai‘i. UH has an abundance of geologic and geothermal data and is looking to the national labs’ expertise to execute this analysis. UH is also interested in investigating policy, regulatory, and business conditions advantageous for implementation of a pilot project and more broad deployment of this technology in Hawai‘i. In many locations around the world, the demands for heating and cooling are roughly balanced over the course of the year, so GHEs do not cause significant long-term changes in subsurface temperature. This is not the case in Hawai’i, where the demand for heating is very small, meaning that, over time, GHEs will add heat to the subsurface. If temperatures increase significantly, GHE systems will not work as designed. Regional groundwater flow has the potential to sweep heated water away from boreholes, thereby maintaining the functionality of the GHE system. Significant regional groundwater flow requires two things: a sufficiently large driving hydraulic head gradient (usually closely related to surface topography), and sufficient porosity and permeability to enable groundwater to flow in large enough quantities to enable near-borehole temperatures to be maintained at ambient values. Hawai‘i’s volcanic terrain offers ample surface topographic variation. The lava itself shows an extremely large range of porosity and permeability, so sites with large enough values of these properties must be selected. Numerical modeling of coupled groundwater and heat flow can be used to determine how large is large enough. Primarily, closed-loop systems have been investigated. Other options considered are open-loop systems and using cool seawater as the chilling source. Project work investigated the feasibility of GHE technology at two scales. At the island scale, GIS layers of various attributes relevant for GHE were combined to develop an overall favorability map for employing GHE in Hawai‘i. At the local scale, a hydrogeologic model for the subsurface component of a closed-loop system was developed for the Stan Sheriff Center at the UH Manoa campus. This site is considered promising because the rock below and immediately downgradient of the borefield is highly permeable, consisting of a subsurface karst system (limestone containing high-permeability open channels), which is underlain by a thick, high-permeability fractured basalt. Moreover, the site is near the base of the Ko‘olau Range, providing a large hydraulic head gradient. Thus, groundwater flow through the site is expected to be large, enabling efficient removal of heated groundwater. A full-GHE-system model of the site was also developed, with a simplified representation of the subsurface, in which groundwater flow is not considered and heat transfer is purely by conduction. Using the building cooling load data provided by UH, simulation results show that with groundwater flow present, a GHE can operate successfully for at least 10 years, but with no groundwater flow, the subsurface begins to heat up after only one year of operation, making the GHE unviable within 2-6 years. The team also developed a techno-economic model for this site to compare the cost of cooling using a GHE system with the costs of operating the current air-conditioning system. The GHE system is advantageous economically if favorable tax incentives and interest rates can be obtained.

15 GEOTHERMAL ENERGY↗

Investigation of Dynamic Aerodynamics and Control of Wind Turbine Sections Under Relevant Inflow/Blade Attitude Conditions

The growth of wind turbines has led to highly variable loading on the blades. Coupled with the relative reduced stiffness of longer blades, the need to control loading on the blades has become important. One method of controlling loads and maximizing energy extraction is local control of the flow on the wind turbine blades. The goal of the present work was to better understand the sources of the unsteady loading and then to control them. This is accomplished through an experimental effort to characterize the unsteadiness and the effect of a Gurney flap on the flow, as well as an analytical effort to develop control approaches. It was planned to combine these two efforts to demonstrate control of a wind tunnel test model, but that final piece still remains to be accomplished.

17 WIND ENERGY↗

Flexible cryogenic air separation unit—An application for low-carbon fossil-fuel plants

In this study, the rapid integration of intermittent renewable sources into the electricity grid is driving the need for a flexible cryogenic air separation unit (ASU) coupled with a low-carbon fossil-fuel plant. However, the state-of-the-art ASU process is highly integrated and nonlinear, which can significantly restrict its ramping rate. In this work, we study the fundamental dynamics of a state-of-the-art double-column ASU, focusing on the dynamic characteristics of the highly integrated and nonlinear heat and mass transfers, and we propose basic control methods for achieving high process ramping rates. We found that the vapor–liquid countercurrent flows in the low-pressure column are critical to the cryogenic rectification of air, which governs the ramp rate of the ASU. This countercurrent flow structure is created through a complex heat integration process in the ASU. Here, this process is simplified as a countercurrent heat transfer to reduce the complexity of studying the ASU dynamics. To preserve this flow structure, the heat integration is maintained so that its heat duty follows the ASU load, using several basic controllers on the critical stream flowrates. A flow-driven dynamic ASU model is built in Aspen Plus Dynamics to capture the basic ramping dynamics. This model revealed a fundamental mismatch in the dynamics in the ASU column that causes a significant loss of O 2 product purity when ramping down the ASU and slightly increases the purity when ramping up. Based on these findings, we propose a basic control method for rapidly ramping down/up the ASU while maintaining O 2 product purity. Simulation results show the ASU basic dynamic process successfully ramps at a rate up to 10 %/min (40–100 % load) while maintaining the O 2 product purity at 95.2–95.6 mol%.

42 ENGINEERING↗

Elastic-plastic finite element analyses of an unidirectional, 9 vol percent tungsten fiber reinforced copper matrix composite

Micromechanical modeling via elastic-plastic finite element analyses were performed to investigate the effects that the residual stresses and the degree of matrix work hardening (i.e., cold-worked, annealed) have upon the behavior of a 9 vol percent, unidirectional W/Cu composite, undergoing tensile loading. The inclusion of the residual stress-containing state as well as the simulated matrix material conditions proved to be significant since the Cu matrix material exhibited plastic deformation, which affected the subsequent tensile response of the composite system. The stresses generated during cooldown to room temperature from the manufacturing temperature were more of a factor on the annealed-matrix composite, since they induced the softened matrix to plastically flow. This event limited the total load-carrying capacity of this matrix-dominated, ductile-ductile type material system. Plastic deformation of the hardened-matrix composite during the thermal cooldown stage was not considerable, therefore, the composite was able to sustain a higher stress before showing any appreciable matrix plasticity. The predicted room temperature, stress-strain response, and deformation stages under both material conditions represented upper and lower bounds characteristic of the composite's tensile behavior. The initial deformation stage for the hardened material condition showed negligible matrix plastic deformation while for the annealed state, its initial deformation stage showed extensive matrix plasticity. Both material conditions exhibited a final deformation stage where the fiber and matrix were straining plastically. The predicted stress-strain results were compared to the experimental, room temperature, tensile stress-strain curve generated from this particular composite system. The analyses indicated that the actual thermal-mechanical state of the composite's Cu matrix, represented by the experimental data, followed the annealed material condition.

Sanfeliz, Jose G.↗