Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

NMR Measurements for Solid Polarized Targets at Jefferson Lab

Jefferson Lab's solid polarized targets rely on Nuclear Magnetic Resonance techniques to measure the enhanced polarization provided under Dynamic Nuclear Polarization. Upcoming polarized target experiments in JLab's Hall B present challenging conditions which would benefit from improvements to traditional NMR techniques. For decades, JLab has utilized Liverpool Q Meters for NMR measurements, but these are aging and no longer produced. The polarized target group at Bochum has successfully produced replacement Q Meters with modern components, and we are following their example, exploring new designs for both an analog and a digital Q Meter system. Unlike recent experiments in Halls A and C, the new Hall B target will require external NMR coils, resulting in a weaker signal. In addition, two separate target cells will be utilized, each held at different magnetic fields, allowing them to be polarized in opposing directions, but complicating the NMR measurement. We present the challenges presented by the new Hall B target, lay out plans for improvements to our NMR system, and show results of initial tests of our designs.

Maxwell, James↗

Aharonov-Bohm radiation of fermions

We analyze Aharonov-Bohm radiation of charged fermions from oscillating solenoids and cosmic strings. We find that the angular pattern of the radiation has features that differ significantly from that for bosons. For example, fermionic radiation in the lowest harmonic is approximately isotropically distributed around an oscillating solenoid, whereas for bosons the radiation is dipolar. We also investigate the spin polarization of the emitted fermion-antifermion pair. Fermionic radiation from kinks and cusps on cosmic strings is shown to depend linearly on the ultraviolet cutoff, suggesting strong emission at an energy scale comparable to the string energy scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New superconducting electron cyclotron resonance ion source for RIKEN RI beam factory project

For RIKEN radio isotope beam project, we started to construct the new superconducting electron cyclotron resonance ion source (SC-ECRIS), which has an operational frequency of 28 GHz, in 2007. The main feature of this ion source is that we can produce large size of resonance zone with six sets of solenoid coils. Before starting, we intensively studied the effect of several key parameters of ECRIS (magnetic field configuration, microwave power density, negatively biased disk) on the plasma. In this article, we describe the effect of key parameters on the plasma and detailed structure of the new SC-ECRIS.

43 PARTICLE ACCELERATORS↗

Magnetoelastic standing waves induced in UO 2 by microsecond magnetic field pulses

Significance UO 2 is of particular interest due to its use as a nuclear fuel, its unusually poor thermal conductivity, and its uniquely strong magnetoelastic properties characterized by a linear coupling between strain and magnetization. We clearly observe mechanical standing waves and elastic resonances in a single crystal, induced by microsecond magnetic field pulses. The phase and amplitude of the mechanical resonances are modulated by the piezomagnetic switching behavior, offering a sensitive probe for otherwise hard to detect magnetic dynamics in UO 2 . We highlight the importance of magnetic domains in the attenuation of the mechanical resonances and the robustness of the antiferromagnetic state in UO 2 against externally applied magnetic fields to 150 T.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rapid and semi-analytical design and simulation of a toroidal magnet made with YBCO and MgB 2 superconductors

Recent advances in second-generation (YBCO) high-temperature superconducting wire could potentially enable the design of super high performance energy storage devices that combine the high energy density of chemical storage with the high power of superconducting magnetic storage. However, the high aspect ratio and the considerable filament size of these wires require the concomitant development of dedicated optimization methods that account for the critical current density in type-II superconductors. In this study, we report on the novel application and results of a CPU-efficient semianalytical computer code based on the Radia 3-D magnetostatics software package. Our algorithm is used to simulate and optimize the energy density of a superconducting magnetic energy storage device model, based on design constraints, such as overall size and number of coils. The rapid performance of the code is pivoted on analytical calculations of the magnetic field based on an efficient implementation of the Biot-Savart law for a large variety of 3-D “base” geometries in the Radia package. The significantly reduced CPU time and simple data input in conjunction with the consideration of realistic input variables, such as material-specific, temperature, and magnetic-field-dependent critical current densities, have enabled the Radia -based algorithm to outperform finite-element approaches in CPU time at the same accuracy levels. Comparative simulations of MgB 2 and YBCO-based devices are performed at 4.2 K, in order to ascertain the realistic efficiency of the design configurations.

2G↗

Feasibility study of a swept frequency electromagnetic probe (SWEEP) using inductive coupling for the determination of subsurface conductivity of the earth and water prospecting in arid regions

Techniques developed for electromagnetic probing of the lunar interior, and techniques developed for the generation of high power audio frequencies were combined to make practical a magnetic inductive coupling system for the rapid measurement of ground conductivity profiles which are helpful when prospecting for the presence and quality of subsurface water. A system which involves the measurement of the direction, intensity, and time phase of the magnetic field observed near the surface of the earth at a distance from a horizontal coil energized so as to create a field that penetrates the earth was designed and studied to deduce the conductivity and stratification of the subsurface. Theoretical studies and a rudimentary experiment in an arid region showed that the approach is conceptually valid and that this geophysical prospecting technique can be developed for the economical exploration of subterranean water resources.

Latorraca, G. A.↗

Features of polar cusp electron precipitation associated with a large magnetic storm

Measurements of precipitating electrons made by the OGO-4 satellite reveal several interesting phenomena in the polar cusp. Extremely high fluxes of 0.7 keV electrons were observed in the polar cusp ninety minutes following the sudden commencement of a very large magnetic storm. Structured, fairly high fluxes of 7.3 keV electrons were also observed in the cusp region, accompanied by very strong search coil magnetometer fluctuations, indicative of strong field-aligned currents. The observations confirm previously reported latitudinal shifts in the location of the polar cusp in response to southward interplanetary magnetic fields.

Berko, F. W.↗

Construction and testing of the 2.5m mass driver

Presented are the designs used in the construction of the 2.5 m mass driver and the results of the initial testing program. The mass driver consists of equal length sections of acceleration and deceleration each containing 59 drive coils of 13.1 cm caliber. Intermediate energy storage is provided by sector capacitors which are recharged every half cycle by an external power source. The drive coils are individually energized through SCR's with timing supplied by position sensing optical detectors. The drive consists of two phases which operate in quadrature. The initial bucket to be propelled through the mass driver contains two coils of aluminum wire chilled to liquid nitrogen temperatures to momentarily sustain superconducting field intensities. Magnetic flight is generated by eddy current repulsion from six copper guide strips lining the mass driver. Nominal acceleration is 5000 m/sec per sec giving a maximum bucket velocity of 112 m/s.

Snow, W. R.↗

Electromagnetic-gravitational energy systems

Two methods are considered to 'tap' the earth's rotational energy. This ancient 'collapsed gravitational energy' exceeds the earth-lunar binding energy. One involves an orbiting 'electromagnetic-gravitational' coupling system whereby the earth's rotation, with its nonuniform mass distribution, first uses gravity to add orbital energy to a satellite, similar to a planetary 'flyby'. The second stage involves enhanced satellite 'drag' as current-carrying coils withdraw the added orbital energy as they pass through the earth's nonuniform magnetic field. A second more direct method couples the earth's rotational motion using conducting wires moving through the noncorotating part (ionospheric current systems) of the geomagnetic field. These methods, although not immediately feasible, are considerably more efficient than using pure gravitational coupling to earth-moon tides.

Schatten, K. H.↗

Shaft transducer having dc output proportional to angular velocity

A brushless dc tachometer is disclosed that includes a high strength toroidal permanent magnet for providing a uniform magnetic field in an air gap, an annular pole piece opposite the magnet, and a pickup coil wound around the pole piece and adapted to rotate about the axis of the pole piece. The pickup coil is rotated by an input shaft to which the coil is coupled with the friction clip. The output of the coil is conducted to circuitry by a twisted wire pair. The input shaft also activates a position transducing potentiometer.

Handlykken, M. B.↗

Development of frequency step tunable 1 MW gyrotron at 131 to 146.5 GHz

Effective control of power absorption in tokamaks and stellarators could be achieved by the frequency tuning of ECH and CD power delivered by high-power gyrotrons. In this report some results of the development of a frequency tunable gyrotron with fused-silica Brewster window are presented. Excitation of several modes at 1 MW power level in the range of frequencies from 131 to 146.5 GHz is achieved. (author)

43 PARTICLE ACCELERATORS↗

Magnetic field, frequency and temperature dependence of complex conductance of ultrathin La1.65Sr0.45CuO4/La2CuO4 films and the organic superconductors κ-(BEDT-TTF)2Cu[N(CN)2]Br

We used atomic-layer molecular beam epitaxy (ALL-MBE) to synthesize bilayer films of a cuprate metal (La1.65Sr0.45CuO4La1.65Sr0.45CuO4, LSCO) and a cuprate insulator (La2CuO4La2CuO4, LCO), in which interface superconductivity occurs in a layer that is just one-half unit cell thick. We have studied the magnetic field and temperature dependence of the complex sheet conductance, σ(ω)σ(ω), of these films, and compared them to κκ-(BEDT-TTF)2Cu[N(CN)2]Br2Cu[N(CN)2]Br single crystals. The magnetic field HH was applied both parallel and perpendicular to the 2D conducting layers. Experiments have been carried out at frequencies between 23 kHz and 50 MHz using either two-coil mutual inductance technique, or the LC resonators with spiral or rectangular coils. The real and the imaginary parts of the mutual-inductance M(T,ω)M(T,ω) between the coil and the sample were measured and converted to complex conductivity. For HH perpendicular to the conducting layers, we observed almost identical behavior in both films and κκ-Br single crystals: (i) the transition onset in the inductive response, L-1kLk-1(T) occurs at a temperature lower by 2 K than in Reσ(T)Reσ(T), (ii) this shift is almost constant with magnetic field up to 8 T; (iii) the vortex diffusion constant D(T)D(T) is exponential due to pinning of vortex cores. These results can be described by the extended dynamic theory of the Berezinski–Kosterlitz–Thouless (BKT) transition and dynamics of bound vortex–antivortex pairs with short separation lengths.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Fabrication of the Superconducting Horizontal Bend Magnet for the Super High Momentum Spectrometer at Jefferson Lab

A collaboration exists between NSCL and JLab to design and build JLab's Super High Momentum Spectrometer (SHMS) horizontal bend magnet that allows the bending of the 12 GeV/c particles horizontally by 3° to allow SHMS to reach angles as low as 5.5°. Two full size coils have been wound and are cold tested for both magnetic and structural properties. Each coil is built from 90 layers of single-turn SSC outer conductor cable. An initial test coil with one third the turns was fabricated to demonstrate that the unique saddle shape with fully contoured ends could be wound with Rutherford superconducting cable. Learned lessons during the trial winding were integrated into the two complete full-scale coils that are now installed in the helium vessel. The fabrication of the iron yoke, cold mass, and thermal shield is complete, and assembly of the vacuum vessel is in progress. This paper presents the process and progress along with the modified magnet design to reduce the fringe field in the primary beam region and also includes the impact of the changes on coil forces and coil restraint system.

43 PARTICLE ACCELERATORS↗

Miniature pulsed magnet system for synchrotron x-ray measurements

We have developed a versatile experimental apparatus for synchrotron x-ray measurements in pulsed high magnetic fields. The apparatus consists of a double cryostat incorporating a liquid nitrogen bath to cool the miniature pulsed coil and an independent helium flow cryostat allowing sample temperatures from 4 up to 250 K. The high duty cycle miniature pulsed coils can generate up to 38 T. During experiments at 30 T a repetition rate of 6 pulses/min was routinely reached. Using a 4 kJ power supply, the pulse duration was between 500 {mu}s and 1 ms. The setup was used for nuclear forward scattering measurements on {sup 57}Fe up to 25 T on the ESRF beamline ID18. In another experiment, x-ray magnetic circular dichroism was measured up to 30 T on the ESRF energy dispersive beamline ID24.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic and Cryogenic Design of the MICE Coupling Solenoid Magnet System

The Muon Ionization Cooling Experiment (MICE) will demonstrate ionization cooling in a short section of a realistic cooling channel using a muon beam at Rutherford Appleton Laboratory in the UK. The coupling magnet is a superconducting solenoid mounted around four 201MHz RF cavities, which produces magnetic field up to 2.6 T on the magnet centerline to keep muons within the iris of RF cavities windows. The coupling coil with inner radius of 750mm, length of 285mm and thickness of 102.5mm will be cooled by a pair of 1.5 W at 4.2 K small coolers. This paper will introduce the updated engineering design of the coupling magnet made by ICST in China. The detailed analyses on magnetic fields, stresses induced during the processes of winding, cool down and charging, and cold mass support assembly are presented as well.

42 ENGINEERING↗

Control of a Bose-Einstein condensate on a chip by external optical and magnetic potentials

In this paper we explore the possibilities of control of a Bose-Einstein condensate on an atom chip by the use of potentials generated by photonic and magnetic components. We show that the fields produced by both types of components can be modelled by a generic exponential potential and derive analytic expressions that allow for an easy assessment of their impact on a trapped condensate. Using dynamical numerical simulations we study the transport of the condensate between the control structures on a chip. We study in detail different regimes of the condensate behaviour in an evanescent light potential generated by a photonic structure in the vicinity of the condensate and in magnetic potentials generated by a wire or a coil. The calculations are based on the reported parameters of atom chip setups and available photonic and magnetic components. Finally, the model is verified by an experiment with a condensate on an atom chip and a coil. - Highlights: Black-Right-Pointing-Pointer Generic potential used to describe both the optical evanescent and magnetic fields. Black-Right-Pointing-Pointer An analytic closed form solution found for the impact of a generic potential on a BEC. Black-Right-Pointing-Pointer BEC dynamics calculated for potential time sequences attainable in experiments. Black-Right-Pointing-Pointer Conditions for BEC transfer by an external field identified. Black-Right-Pointing-Pointer Exponential-potential model validated by a BEC-on-chip experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shallow Embedded Strain Measurements and Analysis for a NbTi Superconducting Sextupole Coil During Cooling, Excitation, and Quench

The present study deals with strain measurements and their numerical analysis for a niobium titanium wire wounded superconducting sextupole coil in a multi-field operation environment, including cooling down, excitation, and quench. Four low-temperature resistance strain gauges with designed compensation circuits were affixed directly on the surface of the superconducting wires but within glass fiber cloth. Before the sextuple coil’s test was carried out, for the purpose of reliability, based on the designed compensation circuit, some basic experiments were carried out during cooling down, excitation, and quench. The experimental results showed that the shallow embedded low-temperature resistance strain gauges were still highly reproducible with an error of 1% for a variable magnetic field and an error of 5% for a variable thermal field by executing various modes. It shows multi-stage strain monitoring is feasible for the superconducting sextupole. In addition, a numerical multiphysics model for the sextuple coil is also built from Maxwell’s equations and the equilibrium equations for mechanical and thermal deformation. A self-tested elastic modulus of NbTi/Cu stack with epoxy, which is cut from a NbTi/Cu sextupole prototype, at low temperature is used in this simulation. The numerical results have reasonable agreement with the experimental observations and show the multiphysics model with self-tested elastic modulus can be applied to analysis strain behaviors under complicated fields before superconducting magnet assembly. The present results will also provide some strain-measuring technology and multiphysics numerical analysis on an LTS/HTS superconducting magnet developed at the Institute of Modern Physics, Chinese Academy of Sciences (IMP, CAS).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Error Field Correction in ITER

A new method for correcting magnetic field errors in the ITER tokamak is developed using the Ideal Perturbed Equilibrium Code (IPEC). The dominant external magnetic field for driving islands is shown to be localized to the outboard midplane for three ITER equilibria that represent the projected range of operational scenarios. The coupling matrices between the poloidal harmonics of the external magnetic perturbations and the resonant fields on the rational surfaces that drive islands are combined for different equilibria and used to determine an ordered list of the dominant errors in the external magnetic field. It is found that efficient and robust error field correction is possible with a fixed setting of the correction currents relative to the currents in the main coils across the range of ITER operating scenarios that was considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗