Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Interstellar Extinction, Polarization, and Grain Alignment in the Sh 2-185 (IC 59 and IC 63) Region

Optical and infrared continuum polarization from the interstellar medium is driven by radiative processes aligning the grains with the magnetic field. While a quantitative, predictive theory of radiative alignment torques (RATs) exists and has been extensively tested, several parameters of the theory remain to be fully constrained. In a recent paper, Medan & Andersson showed that the polarization efficiency (and therefore grain alignment efficiency) at different locations in the wall of the Local Bubble (LB) could be modeled as proportional to the integrated light intensity from the surrounding stars and OB associations. Here we probe that relationship at high radiation field intensities by studying the extinction and polarization in the two reflection nebulae IC 59 and IC 63 in the Sh 2-185 H ii region, illuminated by the B0 IV star γ Cassiopeia. We combine archival visual polarimetry with new seven-band photometry in the Vilnius system, to derive the polarization efficiency from the material. We find that the same linear relationship seen in the LB wall also applies to the Sh 2-185 region, strengthening the conclusion from the earlier study.

47 OTHER INSTRUMENTATION↗

An unshielded radio-frequency atomic magnetometer with sub-femtoTesla sensitivity

We demonstrate a radio-frequency potassium-vapor magnetometer operating with sensitivities of 0.3 fT/√(Hz) at 0.5 MHz and 0.9 fT/√(Hz) at 1.31 MHz in the absence of radio-frequency and mu-metal or magnetic shielding. The use of spatially separated magnetometers, two voxels within the same cell, permits for the subtraction of common mode noise and the retention of a gradient signal, as from a local source. At 0.5 MHz the common mode noise was white and measured to be 3.4 fT/√(Hz); upon subtraction the noise returned to the values observed when the magnetometer was shielded. At 1.31 MHz, the common mode noise was from a nearby radio station and was reduced by a factor of 33 upon subtraction, limited only by the radio signal picked up by receiver electronics. Potential applications include in-the-field low-field magnetic resonance, such as the use of nuclear quadrupole resonance for the detection of explosives.

36 MATERIALS SCIENCE↗

Magnetic control systems for large spacecraft with applications to space telescope

Magnetic control systems for large space vehicles offer the advantage of a simple, reliable, low cost augmentation to the primary control system. When used for momentum management, a magnetic torque source offers a long life and noncontaminant environment when compared to a mass expulsion torque source. These qualities make such systems suitable for employment with the Space Telescope, which is a long life, high performance vehicle with optics and scientific instruments which would be degraded by contamination due to mass expulsion products. The various applications of magnetic systems on the Space Telescope are considered. The future trend in magnetic control of large space vehicles lies in providing a known three axis reference for backup operations, such as recovery of the primary control mode.

Dougherty, H.↗

MESSENGER'S First and Second Flybys of Mercury

The MESSENGER mission to Mercury offers our first opportunity to explore this planet's miniature magnetosphere since Mariner 10's brief fly-bys in 1974-5. The magnetosphere of Mercury is the smallest in the solar system with its magnetic field typically standing off the solar wind only approximately 1000 km above the surface. An overview of the MESSENGER mission and its January 14th and October 6th, 2008 close flybys of Mercury will be provided. Primary science objectives and the science instrumentation will be described. Initial results from MESSENGER will be discussed with an emphasis on the magnetic field and charged particle measurements.

Slavin, James A.↗

PRODUCTION OF THE EXTREME-ULTRAVIOLET LATE PHASE OF AN X CLASS FLARE IN A THREE-STAGE MAGNETIC RECONNECTION PROCESS

We report on observations of an X class flare on 2011 September 6 by the instruments on board the Solar Dynamics Observatory. The flare occurs in a complex active region with multiple polarities. The Extreme-Ultraviolet (EUV) Variability Experiment observations in the warm coronal emission reveal three enhancements, the third of which corresponds to an EUV late phase. The three enhancements have a one-to-one correspondence to the three stages in flare evolution identified by the spatially resolved Atmospheric Imaging Assembly observations, which are characterized by a flux rope eruption, a moderate filament ejection, and the appearance of EUV late phase loops, respectively. The EUV late phase loops are spatially and morphologically distinct from the main flare loops. Multi-channel analysis suggests the presence of a continuous but fragmented energy injection during the EUV late phase resulting in the warm corona nature of the late phase loops. Based on these observational facts, we propose a three-stage magnetic reconnection scenario to explain the flare evolution. Reconnections in different stages involve different magnetic fields but show a casual relationship between them. The EUV late phase loops are mainly produced by the least energetic magnetic reconnection in the last stage.

79 ASTRONOMY AND ASTROPHYSICS↗

An atomic magnetometer with autonomous frequency stabilization and large dynamic range

The operation of a highly sensitive atomic magnetometer using elliptically polarized resonant light is demonstrated. It is based on measurement of zero magnetic field resonance in degenerate two level systems using polarimetric detection. The transmitted light through the polarimeter is used for laser frequency stabilization, whereas reflected light is used for magnetic field measurement. Thus, the experimental geometry allows autonomous frequency stabilization of the laser frequency leading to compact operation of the overall device and has a preliminary sensitivity of <10 pT/Hz{sup 1/2} @ 1 Hz. Additionally, the dynamic range of the device is improved by feedback controlling the bias magnetic field without compromising on its sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The multi-purpose three-axis spectrometer (TAS) MIRA at FRM II

The cold-neutron three-axis spectrometer MIRA is an instrument optimized for low-energy excitations. Its excellent intrinsic $Q$-resolution makes it ideal for studying incommensurate magnetic systems (elastic and inelastic). MIRA is at the forefront of using advanced neutron focusing optics such as elliptic guides, which enable the investigation of small samples under extreme conditions. Another advantage of MIRA is the modular assembly allowing for instrumental adaption to the needs of the experiment within a few hours. The development of new methods such as the spin-echo technique MIEZE is another important application at MIRA. Finally, scientific topics include the investigation of complex inter-metallic alloys and spectroscopy on incommensurate magnetic structures.

36 MATERIALS SCIENCE↗

A high-frequency electron paramagnetic resonance spectrometer for multi-dimensional, multi-frequency, and multi-phase pulsed measurements

We describe instrumentation for a high-frequency electron paramagnetic resonance (EPR) and pulsed electron-electron double resonance (PELDOR) spectroscopy. The instrumentation is operated in the frequency range of 107−120 GHz and 215−240 GHz and in the magnetic field range of 0−12.1 T. The spectrometer consisting of a high-frequency high-power solid-state source, a quasioptical system, a phase-sensitive detection system, a cryogenic-free superconducting magnet, and a {sup 4}He cryostat enables multi-frequency continuous-wave EPR spectroscopy as well as pulsed EPR measurements with a few hundred nanosecond pulses. Here we discuss the details of the design and the pulsed EPR sensitivity of the instrumentation. We also present performance of the instrumentation in unique experiments including PELDOR spectroscopy to probe correlations in an insulating electronic spin system and application of dynamical decoupling techniques to extend spin coherence of electron spins in an insulating solid-state system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of diffusion in internal gradients on nuclear magnetic resonance transverse relaxation measurements

In the present work we study the internal gradient effects on diffusion attenuation of the echo train appearing in the well-known Carr-Purcell-Meiboom-Gill (CPMG) technique, extensively used for transverse relaxation measurements. Our investigations are carried out on two porous ceramics, prepared with the same amount of magnetic impurities (Fe{sub 2}O{sub 3}) but different pore sizes. It is shown that diffusion effects on the CPMG echo train attenuation are strongly influenced by the pore size for the same magnetic susceptibility of the two samples. The experimental results were compared with a theoretical model taking into account the limit of free or restricted diffusion on echo train attenuation. The NMR experiments were performed on water filled samples using a low-field NMR instrument. The porous ceramics were prepared using both the replica technique and the powder compression technique. Magnetic susceptibility measurements indicated close values of the susceptibility constant for the two samples whereas the SEM images indicated different pore sizes. The results reported here may have impact in the interpretation of NMR relaxation measurements of water in soils or concrete samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Zeeman splitting measurements in a high-temperature plasma

The Zeeman effect has been used for measurement of magnetic fields in low-temperature plasma, but the diagnostic technique is difficult to implement in a high-temperature plasma. This paper describes new instrumentation and methodology for simultaneous measurement of the entire Doppler-broadened left and right circularly polarized Zeeman spectra in high-temperature plasmas. Measurements are made using spectra emitted parallel to the magnetic field by carbon impurities in high-temperature plasma. The Doppler-broadened width is much larger than the magnitude of the Zeeman splitting, thus simultaneous recording of the two circularly polarized Zeeman line profiles is key to accurate measurement of the magnetic field in the ZaP Z-pinch plasma device. Spectral data are collected along multiple chords on both sides of the symmetry axis of the plasma. This enables determination of the location of the current axis of the Z-pinch and of lower-bound estimates of the local magnetic field at specific radial locations in the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Proposed Fast Luminosity Feedback for the Super-B Accelerator

We present a possible design for a fast luminosity feedback for the SuperB Interaction Point (IP). The design is an extension of the fast luminosity feedback installed on the PEP-II accelerator. During the last two runs of PEP-II and BaBar (2007-2008), we had an improved luminosity feedback system that was able to maintain peak luminosity with faster correction speed than the previous system. The new system utilized fast dither coils on the High-Energy Beam (HEB) to independently dither the x position, the y position and the y angle at the IP, at roughly 100 Hz. The luminosity signal was then read out with three independent lock-in amplifiers. An overall correction was computed based on the lock-in signal strengths and beam corrections for position in x and y and in the y angle at the IP were simultaneously applied to the HEB. With the 100 times increase in luminosity for the SuperB design, we propose using a similar fast luminosity feedback that can operate at frequencies between DC and 1 kHz, high enough to follow any beam motion from the final focusing magnets.

43 PARTICLE ACCELERATORS↗

Spectral transmissometer and radiometer - Design and initial results

A new solid-state spectral transmissometer and radiometer is described. The radiometer measures upwelling radiance, downwelling irradiance, and beam transmittance from 390 to 750 nm with channel widths of 2.35 nm. The spectrometer consists of a 256 element CCD linear array collecting light dispersed by a reflection grating in a modified Littrow configuration. The spectrometer is time and space-shared among the three signal types. The instrument has been deployed as a free-drifting buoy and in the profiling mode, with data stored internally on a magnetic bubble memory or sent up a conducting cable as desired. Power can be supplied either by a detachable external battery pack or through conducting cable. The instrument has been deployed in the oligotrophic North Pacific Central Gyre and in the eutrophic Straits of Juan de Fuca, and preliminary results for each region are discussed.

Carder, Kendall L.↗

Summary of Results for Idaho Accelerator Center (IAC) Experiments with Compact Electron Permanent Magnet Spectrometer (CEPMS)

The Compact Electron Permanent Magnet Spectrometer (CEPMS) shown in Figure 2 consists of collimation at the electron beam entrance, a vacuum chamber for beam transport and a removable 60 degree sector magnet constructed by SABR Enterprises (Ref 2) that is used to momentum analyze the incoming electron beam. There are electron detection planes located perpendicular to straight through and the 60 degree trajectory ports. The planes are designed to accept phosphor screens for time integrated measurements. The screens can be replaced by scintillator for time resolved measurements using gated or streak cameras. The length of the spectrometer along the beamline without the collimator is about 400mm (14”). The spectrometer requires no power supply with controls for cycling or cooling for the magnet. The entire assembly, with magnet installed, weighs about 35kg (75lbs) Figure 3 depicts central and extreme trajectories through the spectrometer for various electron energies. The chamber accommodates a +/-50mm wide detection field relative to the center trajectory. Trajectories with larger momentum (energy) are bent the least. Since the permanent magnet slides off and on with reference to the upstream edge of the vacuum chamber, it can be adjusted to various positions to slightly increase or decrease the central energy thereby changing the range of available energies. Figure 4 shows the effect of changing the location of the permanent magnet on the electron trajectory. A small inward change in r produces a longer trajectory in the magnet therefore, the same energy trajectory is bent more.

43 PARTICLE ACCELERATORS↗

Building Datasets and Training Methods for ML Based Magnet Quench Detection

Detecting quenches in superconducting (SC) magnets during training is a challenging process that involves capturing physical events that occur at different frequencies and appear as various signal features. These events may be correlated across instrumentation type, thermal cycle, and ramp. These events together build a more complete picture of continuous processes occurring in the magnet, and may allow us to flag potential precursors for quench detection. We present our work on building an automatic machine learning (ML) based quench detection system. We build upon our existing work on unsupervised auto-encoders for acoustic sensors and quench antenna (QA) by first establishing a supervised ML training pipeline. We show the results of an event tagging, analysis, and simulation framework on our QA and acoustic data which are used concurrently to build a training dataset for a supervised implementation. We then show how this supervised training can be used as a prior in a semi-supervised framework and compare this to the unsupervised neural network auto-encoder performance.This allows us to have a more concrete understanding of the performance of our algorithms relative to physical events occurring in the magnet, and also provides a baseline software tool to generically evaluate our quench prediction autoencoders under completely unsupervised, supervised, and semi-supervised training conditions.

Khan, Maira [Fermilab]↗

Measurement of solar gravitational oblateness with gravity gradiometers

A very high sensitivity rotating gravity gradiometer onboard the spacecraft is described for measuring the gravitational oblateness of the Sun during a solar probe mission. The proposed instrument would be a self-contained structure in a thermal-vacuum-magnetic shield in the shape of a cross, with a mass of 20 kg and arm length of 1.0 m and thickness of 0.1 m. The sensor inside would have a resonant frequency of 1/30 Hz, a mechanical Q of one million and would use gravitational radiation antenna technology to achieve a sensitivity of 6 x 10 to the minus 8th power Eotvos, which would provide a measurement of the solar oblateness to an accuracy of 1.5 to 6 x 10 to the minus 8th power. The gravity gradiometer will require a spinning spacecraft, so that it will not sense the spacecraft gravity fields, but the gradiometer does not need to be at the spacecraft center of mass, or even on the spacecraft spin axis. Major problem areas to be addressed are demonstration of the instrument sensitivity prior to flight and the measurement and compensation for any residual spacecraft angular rates.

Forward, R. L.↗

Observations of Deep Ionospheric F-Region Density Depletions with FPMU Instrumentation and their Relationship with the Global Dynamics of the June 22-23, 2015 Geomagnetic Storm

The magnetic storm that commenced on June 22, 2015 was one of the largest storms in the current solar cycle, resulting from an active region on the Sun that produced numerous coronal mass ejections (CMEs) and associated interplanetary shock waves. On June 22 at 18:36 UT the magnetosphere was impacted by the leading-edge shock wave and a sheath carrying a large and highly variable interplanetary magnetic field (IMF) Bz with values ranging from +25 to -40 nT. During the subsequent interval from 0000 to 0800 UT, there was a second intensification of the geomagnetic storm resulting from the impact of the CME. We present dramatic responses of simultaneous particle measurements from the high-altitude Magnetospheric Multiscale Mission (MMS) at high altitudes in the magnetosphere (approx. 9-12 Re) and from the low-altitude (F-region) Floating Potential Measurement Unit (FPMU) on board the International Space Station (ISS). We analyze potential causes of these dramatic particle flux dropouts by putting them in the context of storm-time electrodynamics, and support our results with numerical simulations of the global magnetosphere and ionosphere. During the sheath phase of the storm, the MMS spacecraft in the near-earth equatorial plane observed a rapid reconfiguration of the magnetic field near 1923 UT. Initially in the warm plasmasheet, particle flux dropouts were observed as they tracked the plasma-sheet to lobe transitions with the stretching and thinning of the plasmasheet. Anti-sunward flowing O+ ions of ionospheric origin were also measured during this period, confirming that the MMS spacecraft temporarily was in a lobe.

Coffey, Victoria↗

Observations of Deep Ionospheric F-Region Density Depletions with FPMU Instrumentation and their Relationship with the Global Dynamics of the June 22-23, 2015 Geomagnetic Storm

The magnetic storm that commenced on June 22-23, 2015 was one of the largest storms in our current solar cycle, resulting from an active region on the Sun that produced numerous coronal mass ejections (CMEs) and associated interplanetary shock waves. On June 22 at 18:36 UT the magnetosphere was impacted by the shock wave on the magnetosphere. Observations from several spacecraft observed the dynamic response of the magnetosphere and ionosphere. MMS observatories in the near earth tail These low altitude measurements are correlated in the magnetosphere with particle flux dropouts measured by MMS We follow the timing of this storm in the ionosphere with the density depletions throughout the ISS orbits, DMSP drift velocities, and enhanced AMPERE Birkland currents. Together these observations and simulation results will be assembled to provide each region's context to the global dynamics and time evolution of the storm. The models during these event support and flesh out the puzzle of the global dynamics.