Search NASA⌕ Search

SEARCH · Search NASA

Results for “Muon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

RECENT PROGRESS TOWARD A MUON RECIRCULATING LINEAR ACCELERATOR

Both Neutrino Factories (NF) and Muon Colliders (MC) require very rapid acceleration due to the short lifetime of muons. After a capture and bunching section, a linac raises the energy to about 900 MeV, and is followed by one or more Recirculating Linear Accelerators (RLA), possibly followed by a Rapid Cycling Synchnotron (RCS) or Fixed-Field Alternating Gradient (FFAG) ring. A RLA reuses the expensive RF linac section for a number of passes at the price of having to deal with different energies within the same linac. Various techniques including pulsed focusing quadruopoles, beta frequency beating, and multipass arcs have been investigated via simulations to improve the performance and reduce the cost of such RLAs.

43 PARTICLE ACCELERATORS↗

Discussion - Next Step for Fukushima Daiichi Muon Tomography

Specification of Fukushima Daiichi Muon Tomography (FMT): (1) 18-feet (5.5-m) drift tube, 2-inch (5-cm) diameter; (2) 108 tubes per layer; (3) Unit layer = 2 layer (detection efficiency: 0.96 x 0.96 = 92%); (4) 12 or 16 layer per module; (5) 16 layers allows momentum analysis at 30% level; (6) 2 module per super module (5.5 x 11 m{sup 2}); and (7) FMT = 2 super module. By deploying MMT next to a research reactor, we will be able to measure the impact of low level radiation fields on muon tomography and reconstruction processes. Radiation level during reactor operation is {approx}50 {micro}Sv/h which provides similar radiation environment of inside the FMT radiation shield at Fukushima Daiichi. We will implement coincidence algorithm on the FPGA board.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spectrum and Charge Ratio of Vertical Cosmic Ray Muons up to Momenta of 2.5 TeV/c

The ALEPH detector at LEP has been used to measure the momentum spectrum and charge ratio of vertical cosmic ray muons underground. The sea-level cosmic ray muon spectrum for momenta up to 2.5 TeV/c has been obtained by correcting for the overburden of 320 meter water equivalent (mwe). The results are compared with Monte Carlo models for air shower development in the atmosphere. From the analysis of the spectrum the total flux and the spectral index of the cosmic ray primaries is inferred. The charge ratio suggests a dominantly light composition of cosmic ray primaries with energies up to 10{sup 15} eV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress on a Cavity with Beryllium Walls for Muon Ionization Cooling Channel R&D.

The Muon Accelerator Program (MAP) collaboration is working to develop an ionization cooling channel for muon beams. An ionization cooling channel requires the operation of high-gradient, normal-conducting RF cavities in multi-Tesla solenoidal magnetic fields. However, experiments conducted at Fermilab?s MuCool Test Area (MTA) show that increasing the solenoidal field strength reduces the maximum achievable cavity gradient. This gradient limit is characterized by an RF breakdown process that has caused significant damage to copper cavity interiors. The damage may be caused by field-emitted electrons, focused by the solenoidal magnetic field onto small areas of the inner cavity surface. Local heating may then induce material fatigue and surface damage. Fabricating a cavity with beryllium walls would mitigate this damage due to beryllium?s low density, low thermal expansion, and high electrical and thermal conductivity. We address the design and fabrication of a pillbox RF cavity with beryllium walls, in order to evaluate the performance of high-gradient cavities in strong magnetic fields.

43 PARTICLE ACCELERATORS↗

Muons and seismic: a dynamic duo for the shallow subsurface?

Measurements of muon flux and direction at depth provides constraints on density distribution, both spatially and as a function of time. Combination of muon measurements and seismic data provide the potential for improved density estimation and the resolution of elastic parameters.

Inversion↗

Numerical Assessment of SNF Parameter Bandwidths and Muon Tomography Assay for Large Volume Casks - 18185

For the characterization of spent fuel and for the safe direct disposal of SNF we present: a) a method of numerical assessment of their radionuclides inventory that is derived from the initial fuel characteristics and individual burn-up / cooling time history of that particular fuel assembly, and b) how the numerical information can be experimentally assessed using muon tomography as a nondestructive assay of large and heterogeneous SNF casks. We combine both complementary methods, i.e. numerical assessment and muon tomography (MT) experimental assay, to provide a powerful tool for verifying the nuclear inventory without compromising the casks or radioactive material containers. Here, we shall present the numerical assessment technique and preliminary but very promising experimental results, and explain the scope of a versatile and mobile MT-detection system for the identification of nuclear material inside large casks containing spent fuel assemblies and/or other large volume heterogeneous material containers for which the European Commission has recently granted R and D funding within the CHANCE project to be developed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Figures of Merit for the Application of Muon Tomography to the Characterization of Nuclear Waste Drums - 19253

Muon Tomography (MT) has been shown to be a viable candidate for the assay of nuclear storage containers. In this paper we present the development of methods to calculate Figures Of Merit for different MT systems and algorithms based on their ability to image and separate small objects inside legacy nuclear waste drums. These testing methods are then applied to three different tomography algorithms to understand how different cosmic ray muon exposure times and target materials can affect performance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preparations for Muon Experiments at Fermilab

The use of existing Fermilab facilities to provide beams for two muon experiments--the Muon to Electron Conversion Experiment (Mu2e) and the New g-2 Experiment--is under consideration. Plans are being pursued to perform these experiments following the completion of the Tevatron Collider Run II, utilizing the beam lines and storage rings used today for antiproton accumulation without considerable reconfiguration.

43 PARTICLE ACCELERATORS↗

Baseline scenario(s) for muon collider proton driver

This paper gives an overview of the various muon collider scenarios and the requirements they put on the Proton Driver. The required proton power is about 4-6MW in all the scenarios, but the bunch repetition rate varies between 12 and 65Hz. Since none of the muon collider scenarios have been simulated end-to-end, it would be advisable to plan for an upgrade path to around 10MW. Although the proton driver energy is flexible, cost arguments seems to favor a relatively low energy. In particular, at Fermilab 8GeV seems most attractive, partly due to the possibility of reusing the three existing fixed energy storage rings for bunch manipulations.

43 PARTICLE ACCELERATORS↗

Search for high-energy muon neutrinos from the"naked-eye" GRB080319B with the IceCube neutrino telescope

We report on a search with the IceCube detector for high-energy muon neutrinos from GRB080319B, one of the brightest gamma-ray bursts (GRBs) ever observed. The fireball model predicts that a mean of 0.12 events should be detected by IceCube for a bulk Lorentz boost of the jet of 300. In both the direct on-time window of 66 s and an extended window of about 300 s around the GRB, there was no excess found above the background. The 90% C.L. upper limit on the number of track-like events from the GRB is 2.7, corresponding to a muon neutrino fluence limit of 9.0 x 10{sup -3} erg cm{sup -2} in the energy range between 145 TeV and 2.1 PeV, which contains 90% of the expected events.

79 ASTRONOMY AND ASTROPHYSICS↗

Accelerator Preparations for Muon Physics Experiments at Fermilab

The use of existing Fermilab facilities to provide beams for two muon experiments - the Muon to Electron Conversion Experiment (Mu2e) and the New g-2 Experiment - is under consideration. Plans are being pursued to perform these experiments following the completion of the Tevatron Collider Run II, utilizing the beam lines and storage rings used today for antiproton accumulation without considerable reconfiguration. Operating scenarios being investigated and anticipated accelerator improvements or reconfigurations will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and testing of the New Muon Lab cryogenic system at Fermilab

Fermi National Accelerator Laboratory is constructing a superconducting 1.3 GHz cryomodule test facility located at the New Muon Lab building. The facility will be used for testing and validating cryomodule designs as well as support systems. For the initial phase of the project, a single Type III plus 1.3 GHz cryomodule will be cooled and tested using a single Tevatron style standalone refrigerator. Subsequent phases involve testing as many as two full RF units consisting of up to six 1.3 GHz cryomodules with the addition of a new cryogenic plant. The cryogenic infrastructure consists of the refrigerator system, cryogenic distribution system as well as an ambient temperature pumping system to achieve 2 K operations with supporting purification systems. A discussion of the available capacity for the various phases versus the proposed heat loads is included as well as commissioning results and testing schedule. This paper describes the plans, status and challenges of this initial phase of the New Muon Lab cryogenic system.

43 PARTICLE ACCELERATORS↗

Pion production for neutrino factories and muon colliders

Optimization of pion and muon production/collection for neutrino factories and muon colliders is described along with recent developments of the MARS15 code event generators and effects influencing the choice of the optimal beam energy.

43 PARTICLE ACCELERATORS↗

The maximum detectable momentum for cosmic ray muons in the minos far detector.

A magnetic detector such as MINOS which is measuring the sign of muons has to deal with issues of bending, which depend on the magnetic field configuration, and multiple scattering, which depends on the amount of material which is traversed. Above some momentum which depends on these factors, the momentum cannot be resolved. Issues related to measurement of the muon charge ratio in MINOS are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interpretation of the atmospheric muon charge ratio in MINOS.

MINOS is the first large magnetic detector deep underground and is the first to measure the muon charge ratio with high statistics in the region near 1 TeV. An approximate formula for the muon charge ratio can be expressed in terms of {epsilon}{sub {pi}} = 115 GeV, {epsilon}{sub K} = 850 GeV and E{sub {mu}}{sup surface} cos {theta}. The implications for K production in the atmosphere will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implications of HARP Results for the Energy of the Proton Driver for a Neutrino Factory and Muon Collider

Cross-section data from the HARP experiment for pion production by protons from a tantalum target have been convoluted with the acceptance of the front-end channel for the proposed neutrino factory or muon collider and integrated over the full phase space measured by HARP, to determine the beam-energy dependence of the muon yield. This permits a determination of the optimal beam energy for the proton driver for these projects. The cross-section data are corrected for the beam-energy dependent 'amplification' due to the development of hadronic showers in a thick target. The conclusion is that, for constant beam power, the yield is maximum for a beam energy of about 7 GeV, but it is within 10% of this maximum for 4 < T{sub beam} < 11 GeV, and within 20% of the maximum for T{sub beam} as low as 2 GeV. This result is insensitive to which of the two HARP groups results are used, and to which pion generator is used to compute the thick target effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon Collider design status

Muon Collider (MC) - proposed by G.I. Budker and A.N. Skrinsky a few decades ago - is now considered as the most exciting option for the energy frontier machine in the post-LHC era. A national Muon Accelerator Program (MAP) is being formed in the USA with the ultimate goal of building a MC at the Fermilab site with c.o.m. energy in the range 1.5-3 TeV and luminosity of {approx} 1.5 {center_dot} 10{sup 34} cm{sup -2} s{sup -1}. As the first step on the way to MC it envisages construction of a Neutrino Factory (NF) for high-precision neutrino experiments. The baseline scheme of the NF-MC complex is presented and possible options for its main components are discussed.

43 PARTICLE ACCELERATORS↗