Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Fission Product Gamma-Ray Line Pairs Sensitive to Fissile Material and Neutron Energy

The beta-delayed gamma-ray spectra from the fission of {sup 235}U, {sup 238}U, and {sup 239}Pu by thermal and near-14-MeV neutrons have been measured for delay times ranging from 1 minute to 14 hours. Spectra at all delay times contain sets of prominent gamma-ray lines with intensity ratios that identify the fissile material and distinguish between fission induced by low-energy or high-energy neutrons.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of nuclear data based on the ASPIS experiments from the SINBAD database - 25428

SINBAD, the Shielding Integral Benchmark Archive and Database, includes the experimental data relative to integral benchmark experiments relevant for radiation shielding applications. The ASPIS experiments, included in the Reactor Shielding section of SINBAD, provide neutron activation foils and spectra measurements performed before/between shielding slabs of Graphite, Sodium, Iron, Steels, Water and combinations of them. Benchmark models for the measurement simulations with the MCNP code are usually provided in SINBAD. Nonetheless, a user-friendly tool is presented, which would be useful for an independent production of MCNP benchmark models. It is based on GPL C++ code called CombLayer. The reports issued for SINBAD on the quality assessment of the ASPIS experiments are also described. The discussion on the quality of the ASPIS experiments for their use in nuclear data evaluations had a positive outcome, except for two experiments out of ten. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

EGRET High Energy Capability and Multiwavelength Flare Studies and Solar Flare Proton Spectra

UNH was assigned the responsibility to use their accelerator neutron measurements to verify the TASC response function and to modify the TASC fitting program to include a high energy neutron contribution. Direct accelerator-based measurements by UNH of the energy-dependent efficiencies for detecting neutrons with energies from 36 to 720 MeV in NaI were compared with Monte Carlo TASC calculations. The calculated TASC efficiencies are somewhat lower (by about 20%) than the accelerator results in the energy range 70-300 MeV. The measured energy-loss spectrum for 207 MeV neutron interactions in NaI were compared with the Monte Carlo response for 200 MeV neutrons in the TASC indicating good agreement. Based on this agreement, the simulation was considered to be sufficiently accurate to generate a neutron response library to be used by UNH in modifying the TASC fitting program to include a neutron component in the flare spectrum modeling. TASC energy-loss data on the 1991 June 11 flare was transferred to UNH. Also included appendix: Gamma-rays and neutrons as a probe of flare proton spectra: the solar flare of 11 June 1991.

Chupp, Edward L.↗

Measurement Of The Neutron Spectrum Of A DD Electronic Neutron Generator

A Cuttler-Shalev (C-S){sup 3}He proportional counter has been used to measure the energy spectrum of neutrons from a portable deuterium-deuterium electronic neutron generator. To improve the analysis of results from the C-S detector digital pulse shape analysis techniques have been used to eliminate neutron recoil artifacts in the recorded data. Data was collected using a 8-GHz, 10-bit waveform digitizer with its full scale corresponding to approximately 6-MeV neutrons. The measurements were made with the detector axis perpendicular to the direction of ions in the ENG in a plane 0.5-m to the side of the ENG, measuring neutrons emitted at an angle from 87.3 deg. to 92.7 deg. with respect to the path of ions in the ENG. The system demonstrated an energy resolution of approximately 0.040 MeV for the thermal peak and approximately 0.13 MeV at the DD neutron energy. In order to achieve the ultimate resolution capable with this type of detector it is clear that a higher-precision digitizer will be needed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Emission Characteristics of Two Mixed-Oxide Fuels: Simulations and Initial Experiments

Simulations and experiments have been carried out to investigate the neutron emission characteristics of two mixed-oxide (MOX) fuels at Idaho National Laboratory (INL). These activities are part of a project studying advanced instrumentation techniques in support of the U.S. Department of Energy's Fuel Cycle Research and Development program and it's Materials Protection, Accounting, and Control for Transmutation (MPACT) campaign. This analysis used the MCNP-PoliMi Monte Carlo simulation tool to determine the relative strength and energy spectra of the different neutron source terms within these fuels, and then used this data to simulate the detection and measurement of these emissions using an array of liquid scintillator neutron spectrometers. These calculations accounted for neutrons generated from the spontaneous fission of the actinides in the MOX fuel as well as neutrons created via (alpha,n) reactions with oxygen in the MOX fuel. The analysis was carried out to allow for characterization of both neutron energy as well as neutron coincidences between multiple detectors. Coincidences between prompt gamma rays and neutrons were also analyzed. Experiments were performed at INL with the same materials used in the simulations to benchmark and begin validation tests of the simulations. Data was collected in these experiments using an array of four liquid scintillators and a high-speed waveform digitizer. Advanced digital pulse-shape discrimination algorithms were developed and used to collect this data. Results of the simulation and modeling studies are presented together with preliminary results from the experimental campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron and Gamma Radiation Monitoring at The Ion Beam Laboratory Building 720 Sandia/NM

Neutron and gamma radiation spectra and dose rates were measured in and around the Ion Beam Laboratory, Building 720, at Sandia/NM. Measurements were made to support the testing of an enhanced target yielding 14 MeV neutrons from the deuterium-tritium (D-T) fusion reaction. The target room has thick concrete walls but an unshielded ceiling. Neutron and gamma radiation in and around the facility appear to be the result of skyshine. Estimates of neutron/gamma dose rates (per 10 9 source neutrons/s) at six (6) monitoring locations were made. Results indicated the need for enhanced radiological controls due to increased neutron production rates.

61 RADIATION PROTECTION AND DOSIMETRY↗

Chi-Nu measurements of the prompt fission neutron spectrum of {sup 235}U and {sup 239}Pu - 25581

Knowledge of the prompt fission neutron spectrum is crucial for understanding the behavior of energetic nuclear systems. Although this energy spectrum has been measured for the major actinides {sup 235}U and {sup 239}Pu for decades, the majority of the available literature data lack the coverage of both incident and outgoing neutron energies and the precision required to accurately guide evaluations and fission models. The Chi-Nu experiment is designed to measure the prompt fission neutron spectrum for a wide range of incident and outgoing neutron energies with attention to uncertainty estimation and assessment of systematic errors in order to provide reliable guidance for evaluations and models of nuclear fission. Preliminary results of the prompt fission neutron spectrum from the neutron-induced fission of {sup 235}U and {sup 239}Pu are presented here, with a focus on the presence of spectral features near multi-chance fission thresholds, pre-equilibrium neutrons in the deduced spectrum, and also on trends of the mean fission neutron energy as a function of the incident neutron energy. While the mean energies of from ENDF/B-VIII.0 are in good agreement with those reported for {sup 235}U spectra, significant disagreements exist above an incident neutron energy of approximately 13 MeV for {sup 239}Pu. Furthermore, in general, the physics features regarding multi-chance fission and pre-equilibrium neutron emission newly-introduced into ENDF/B-VIII.0 appear provide an improved description of the data as compared to ENDF/B-VII.1. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Benchmarking universal machine learning interatomic potentials for rapid analysis of inelastic neutron scattering data

The accurate calculation of phonons and vibrational spectra remains a significant challenge, requiring highly precise evaluations of interatomic forces. Traditional methods based on the quantum description of the electronic structure, while widely used, are computationally expensive and demand substantial expertise. Emerging universal machine learning interatomic potentials (uMLIPs) offer a transformative alternative by employing pre-trained neural network surrogates to predict interatomic forces directly from atomic coordinates. This approach dramatically reduces computation time and minimizes the need for technical knowledge. In this paper, we produce a phonon database comprising nearly 5000 inorganic crystals to benchmark the performance of several leading uMLIPs. We further assess these models in real-world applications by using them to analyze experimental inelastic neutron scattering data collected on a variety of materials. Through detailed comparisons, we identify the strengths and limitations of these uMLIPs, providing insights into their accuracy and suitability for fast calculations of phonons and related properties, as well as the potential for real-time interpretation of neutron scattering spectra. Our findings highlight how the rapid advancement of AI in science is revolutionizing experimental research and data analysis.

inelastic neutron scattering↗

Feasibility of the Precise Energy Calibration for Fast Neutron Spectrometers

Computational studies aimed at improving the accuracy of measurements performed using neutron generators with a tritium target were performed. A measurement design yielding an extremely narrow peak in the energy spectrum of DT neutrons was found. The presence of such a peak establishes the conditions for precise energy calibration of fast-neutron spectrometers.

43 PARTICLE ACCELERATORS↗

CORRELATIONS IN HORIZONTAL BRANCH OSCILLATIONS AND BREAK COMPONENTS IN XTE J1701-462 AND GX 17+2

We studied the horizontal branch oscillations (HBO) and the band-limited components observed in the power spectra of the transient neutron star low-mass X-ray binary XTE J1701-462 and the persistent ''Sco-like'' Z source GX 17+2. These two components were studied based on the state-resolved spectra. We found that the frequencies of XTE J1701-462 lie on the known correlations (WK and PBK), showing consistency with other types of X-ray binaries (black holes, atoll sources, and millisecond X-ray pulsars). However, GX 17+2 is shifted from the WK correlation like other typical Z sources. We suggest that the WK/PBK main track forms a boundary that separates persistent sources from transient sources. The characteristic frequencies of break and HBO are independent of accretion rate in both sources, though it depends on spectral models. We also report the energy dependence of the HBO and break frequencies in XTE J1701-462 and how the temporal properties change with spectral state in XTE J1701-462 and GX 17+2. We studied the correlation between rms at the break and the HBO frequency. We suggest that HBO and break components for both sources probably arise from a similar physical mechanism: Comptonization emission from the corona. These two components could be caused by the same kind of oscillation in a corona with uneven density, and they could be generated from different areas of the corona. We further suggest that different proportions of the Comptonization component in the total flux cause the different distribution between GX 17+2 and XTE J1701-462 in the rms{sub break}-rms{sub HBO} diagram.

79 ASTRONOMY AND ASTROPHYSICS↗

Unusual signatures of the ferromagnetic transition in the heavy Fermion compound UMn2Al20

Magnetic-susceptibility results for single crystals of the new cubic compounds UT{sub 2}Al{sub 20} (T=Mn, V, and Mo) are reported. Magnetization, specific-heat, resistivity, and neutron-diffraction results for a single crystal and neutron diffraction and inelastic spectra for a powder sample are reported for UMn{sub 2}Al{sub 20}. For T=V and Mo, temperature-independent Pauli paramagnetism is observed. For UMn{sub 2}Al{sub 20}, a ferromagnetic transition is observed in the magnetic susceptibility at T{sub c}=20 K. The specific-heat anomaly at T{sub c} is very weak while no anomaly in the resistivity is seen at T{sub c}. We discuss two possible origins for this behavior of UMn{sub 2}Al{sub 20}: moderately small moment itinerant ferromagnetism or induced local-moment ferromagnetism.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Maximum likelihood method to correct for missed levels based on the {Delta}{sub 3}(L) statistic

The {Delta}{sub 3}(L) statistic of random matrix theory is defined as the average of a set of random numbers {l_brace}{delta}{r_brace}, derived from a spectrum. The distribution p({delta}) of these random numbers is used as the basis of a maximum likelihood method to gauge the fraction x of levels missed in an experimental spectrum. The method is tested on an ensemble of depleted spectra from the Gaussian orthogonal ensemble (GOE) and accurately returned the correct fraction of missed levels. Neutron resonance data and acoustic spectra of an aluminum block were analyzed. All results were compared with an analysis based on an established expression for {Delta}{sub 3}(L) for a depleted GOE spectrum. The effects of intruder levels are examined and seen to be very similar to those of missed levels. Shell model spectra were seen to give the same p({delta}) as the GOE.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron measurements onboard the space shuttle

The radiation environment inside a shielded volume is highly complex, consisting of both charged and neutral particles. Since the inception of human space flights, the charged particle component has received virtually all of the attention. There is however, a significant production of secondary neutrons, particularly from the aluminum structure in low earth orbiting spacecrafts. The interactions of galactic cosmic rays (GCR), and solar energetic particles with the earth's atmosphere produce a non-isotropic distribution of albedo neutrons. Inside any reasonable habitable module, the average radiation quality factor of neutrons is about 4-5 times larger than the corresponding average quality factor of charged particles. The measurement of neutrons and their energy spectra is a difficult problem due the intense sources of charged particles. This paper reviews the results of Shuttle flight experiments (made during both solar maximum and solar minimum) to measure the contribution of neutrons to the dose equivalent, as well as theoretical calculations to estimate the appropriate range of neutron energies that contribute most to the dose equivalent. Published by Elsevier Science Ltd.

short duration↗

GALACTIC ULTRACOMPACT X-RAY BINARIES: DISK STABILITY AND EVOLUTION

We study the mass-transfer rates and disk stability conditions of ultracompact X-ray binaries (UCXBs) using empirical time-averaged X-ray luminosities from Paper I and compiled information from the literature. The majority of UCXBs are consistent with evolutionary tracks for white dwarf donors. Three UCXBs with orbital periods longer than 40 minutes have mass-transfer rates above 10{sup -10} M{sub Sun} yr{sup -1}, inconsistent with white dwarf donor tracks. We show that if helium star donors can retain their initial high entropy, they can explain the observed mass-transfer rates of these UCXBs. Several UCXBs show persistent luminosities apparently below the disk instability limit for irradiated He accretion disks. We point out that a predominantly C and/or O disk (as observed in the optical spectra of several) lowers the disk instability limit, explaining this disagreement. The orbital period and low time-averaged mass-transfer rate of 2S 0918-549 provide evidence that the donor star is a low-entropy C/O white dwarf, consistent with optical spectra. We combine existing information to constrain the masses of the donors in 4U 1916-053 (0.064 {+-} 0.010 M{sub Sun }) and 4U 1626-67 (<0.036 M{sub Sun} for a 1.4 M{sub Sun} neutron star). We show that 4U 1626-67 is indeed persistent, and not undergoing a transient outburst, leaving He star models as the best explanation for the donor.

79 ASTRONOMY AND ASTROPHYSICS↗

Solar-flare neutrons and gamma-rays

The numbers and spectra of the accelerated protons and nuclei that produce the neutrons and gamma-rays observed in solar flares are derived, and the results are compared with interplanetary observations of flare protons. The two most widely studied flare acceleration mechanisms, stochastic and diffusive shock acceleration, are discussed, and the arguments favoring the thick-target interaction model for neutron and gamma-ray production at the sun are briefly reviewed. The pertinent results of the theory of neutron and gamma-ray production are presented. The number and spectrum of the accelerated particles are derived from observations of nuclear deexcitation lines and the 2.223 MeV line from several flares. The June 21, 1980 and June 3, 1982 flares, from which a wealth of neutron, gamma-ray and energetic-particle data has recently become available, are discussed.

Murphy, R. J.↗

Breast cancer detection using neutron stimulated emission computed tomography: Prominent elements and dose requirements

Neutron stimulated emission computed tomography (NSECT) is being developed to noninvasively determine concentrations of trace elements in biological tissue. Studies have shown prominent differences in the trace element concentration of normal and malignant breast tissue. NSECT has the potential to detect these differences and diagnose malignancy with high accuracy with dose comparable to that of a single mammogram. In this study, NSECT imaging was simulated for normal and malignant human breast tissue samples to determine the significance of individual elements in determining malignancy. The normal and malignant models were designed with different elemental compositions, and each was scanned spectroscopically using a simulated 2.5 MeV neutron beam. The number of incident neutrons was varied from 0.5 million to 10 million neutrons. The resulting gamma spectra were evaluated through receiver operating characteristic (ROC) analysis to determine which trace elements were prominent enough to be considered markers for breast cancer detection. Four elemental isotopes ({sup 133}Cs, {sup 81}Br, {sup 79}Br, and {sup 87}Rb) at five energy levels were shown to be promising features for breast cancer detection with an area under the ROC curve (A{sub Z}) above 0.85. One of these elements - {sup 87}Rb at 1338 keV - achieved perfect classification at 10 million incident neutrons and could be detected with as low as 3 million incident neutrons. Patient dose was calculated for each gamma spectrum obtained and was found to range from between 0.05 and 0.112 mSv depending on the number of neutrons. This simulation demonstrates that NSECT has the potential to noninvasively detect breast cancer through five prominent trace element energy levels, at dose levels comparable to other breast cancer screening techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deuteron breakup induced by 14-MeV neutrons from inertial confinement fusion

Measurements are reported for the angle-averaged double-differential cross section $\langle$d 2 σ/dE n dΩ n $\rangle$ 0°< θ < 7.4° for the breakup reaction 2 H ($n,2n$) 1 H, induced by 14-MeV neutrons generated using an inertial confinement fusion platform. A bright neutron source, created on the OMEGA Laser System [Boehly et al., Opt. Commun. 133, 495 (1997)] with a luminosity of L = 10 24 s -1 , was used to irradiate deuterated targets. The absolute yields and energy spectra from the breakup neutrons emitted in a forward-angle geometry (θ = 0° to 7.4°) were detected with a sensitive, high-dynamic-range neutron time-of-flight spectrometer. The cross-section data, measured for neutron energy range from 0.5 to 10 MeV, is well reproduced by a theoretical calculation employing realistic nucleon–nucleon and three-nucleon forces.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗