Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical Analyses of Post Irradiation Experiments of the BWR Forsmark

Computer codes which are to be used in nuclear safety research need to be validated prior to their application. For depletion codes, this validation can be done using data from post irradiation experiments (PIE). These experiments consist of a radiochemical analysis of small parts of a fuel rod (FR), which has been irradiated in a nuclear power plant as part of a fuel assembly (FA). This analysis allows the deduction of the isotopic composition of nuclides important for the desired application case. In addition the operation history at the sample location needs to be known and reported with the analysis results. In our work, we perform uncertainty and sensitivity analyses of a model based on a sample from the boiling water reactor (BWR) Forsmark-3 in order to deduce the influence of uncertain system parameters on the nuclide composition of the depleted fuel. In a second step we compare the resulting uncertainties of the nuclide densities with the deviation between their calculated and experimental values. The goal is to obtain quantitative uncertainty data which can be accounted for in a validation procedure. We use the Monte Carlo sampling approach, i.e. repeating the model calculation using statistically varied sets of the uncertain input parameters and analyzing the distributions of the result values statistically. BWR depletion calculations are especially demanding due to the increased complexity and heterogeneity compared to pressurized water reactors (PWR): extensively variable enrichments, complex FA geometries, partial length FRs, strong axially varying moderator density and the common use of gadolinium as burnable absorber in some of the FRs. However, the precise and correct calculation of BWR-depletion is extremely important in view of a possible application in burnup credit for BWR FAs. Therein credit is taken for the reduced reactivity of spent fuel due to the depletion of {sup 235}U for transport and intermediate or final storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear level densities in {sup 47}V, {sup 48}V, {sup 49}V, {sup 53}Mn, and {sup 54}Mn from neutron evaporation spectra

The spectra of neutrons from the (p, n) reactions on {sup 47}Ti, {sup 48}Ti, {sup 49}Ti, {sup 53}Cr, and {sup 54}Cr nuclei were measured in the proton-energy range 7-11 MeV. The measurements were performed with the aid of a fast-neutron spectrometer by the time-of-flight method over the base of the EGP-15 tandem accelerator of the Institute for Physics and Power Engineering (IPPE, Obninsk). Owing to a high resolution and a high stability of the time-of-flight spectrometer used, low-lying discrete levels could be identified reliably along with a continuum section of neutron spectra. An analysis of measured data was performed within the statistical equilibrium and preequilibrium models of nuclear reactions. The relevant calculations were performed by using the exact formalism of Hauser-Feshbach statistical theory supplemented with the generalized model of a superfluid nucleus, the back-shifted Fermi gas model, and the Gilbert-Cameron composite formula for the nuclear level density. The nuclear level densities for {sup 47}V, {sup 48}V, {sup 49}V, {sup 53}Mn, and {sup 54}Mn were determined along with their energy dependences and model parameters. The results are discussed together with available experimental data and recommendations of model systematics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear-level densities in the {sup 49}V and {sup 57}Co nuclei on the basis of evaporated-neutron spectra in (p, n) and (d, n) reactions

The spectra of neutrons from the reactions {sup 49}Ti(p, n){sup 49}V and {sup 57}Fe (p, n){sup 57}Co were measured in the range of proton energies between 8 and 11 MeV along with their counterparts from the reactions {sup 48}Ti(d, n){sup 49}V and {sup 56}Fe (d, n){sup 57}Co at the deuteron energies of 2.7 and 3.8 MeV. These measurements were conducted with the aid of a time-of-flight fast-neutron spectrometer on the basis of the EGP-15 pulsed tandem accelerator of the Institute for Physics and Power Engineering (IPPE, Obninsk). An analysis of measured data was performed within the statistical equilibrium and preequilibrium models of nuclear reactions. The respective calculations based on the Hauser–Feshbach formalism of statistical theory were carried out with nuclear-level densities given by the generalized superfluid model of the nucleus, the backshifted Fermi-gas model, and the Gilbert–Cameron composite formula. The nuclear-level densities of {sup 49}V and {sup 57}Co and their energy dependences were determined. The results were discussed together with available experimental data and data recommended by model systematics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

JRC-IRMM/ORNL Collaboration on Nuclear Data for Nuclear Criticality Safety - 14486

Concerns about using cross sections recommended in the main evaluated data libraries (i.e. ENDF/B, JEFF and JENDL) for nuclear criticality calculations have been a prime motivator for new cross section measurements. The measurements and evaluations discussed in this work are part of a collaboration between the Oak Ridge National Laboratory (ORNL) and the Institute for Reference Material and Measurements of the Joint Research Center (JRC-IRMM) of the European Commission (EC). They are performed in response to the US Nuclear Criticality Safety Program (NCSP) data needs. In particular, the NCSP five-year plan encompasses a listing of elements that have been identified for measurements and evaluations to address issues on criticality safety applications. This listing is based on data deficiency concerns in practical applications that are conveyed by criticality safety practitioners. In general these deficiencies are obtained through the analysis of benchmark calculations. A wealth of evaluations in the main libraries were derived from results of measurements made with poor time-of-flight resolution, and also the description of some data in the neutron energy range above several tens of keV is crude. This impacts both the resolved and unresolved resonance region, and leads to bias effects when resonance structures play an important role. As a consequence only average corrections can be applied in calculations for nuclear criticality calculations where self-shielding, multiple scattering, or Doppler broadening are important. This can lead to erroneous results. Furthermore, many evaluations for nuclides having small neutron-capture cross sections show erroneously high cross sections because the influence of the neutron sensitivity of the old measurement systems was underestimated. Although their neutron capture cross sections are small, these nuclides, if occurring in large amounts, can be important absorbers in criticality calculations, so an accurate determination of these cross sections is required. Over the last seven years the JRC-IRMM/ORNL collaboration has produced many neutron induced cross section data using the Geel Electron Linear Accelerator (GELINA) neutron time-of-flight facility. This facility is ideally suited to measure total, fission and capture cross sections in the energy range from 1 eV to ∼600 keV, which is important for nuclear criticality calculations. In this paper the facility and experimental set-ups at GELINA will be described together with the data reduction and analysis procedures which result in experimental observables including their full covariance information. The importance of combining transmission and partial cross section data will be emphasized. We will give a list of the measured nuclides and discuss the impact of the resulting data and evaluations. (authors)

42 ENGINEERING↗

Sampling and Analysis Plan for USDOE/NNSA Pantex Plant Groundwater Remedial Action Progress

This Sampling and Analysis Plan (SAP) was originally developed as part of the Remedial Design Submittal Package required by the Interagency Agreement (IAG) for the United States Department of Energy/National Nuclear Security Administration (USDOE/NNSA) Pantex Plant. The SAP describes specifications for data collection, methods of sample collection and analysis, and requirements for quality assurance (QA) and quality control (QC) activities implemented during the life cycle of the program to ensure that data are of sufficient quality for their intended purpose (i.e., to support decision making regarding remediation of the groundwater beneath Pantex). The SAP was prepared according to United States Environmental Protection Agency (EPA) guidance on preparation of Quality Assurance Project Plans (QAPPs) QA/R-5 (EPA, 2001) and is designed to be a stand-alone document that describes both field sampling activities as well as QA/QC activities. The SAP is incorporated by reference to the compliance plan provisions of Hazardous Waste Permit No. 50284, issued by the Texas Commission on Environmental Quality, and was submitted as part of the Remedial Design/Remedial Action Work Plan submitted to EPA in accordance with the Interagency Agreement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Background investigation in EDELWEISS-III

Protection from and rejection of backgrounds is a key issue for the EDELWEISS-III direct dark matter detection experiment which aims at exploring the 10{sup −9} pb cross-section region for spin-independent WIMP-nucleon interaction. The detector is located in the low radioactivity environment of the Modane Underground Laboratory and consists of 36 advanced FID germanium detectors operating at 18 mK in a dilution refrigerator in order to identify eventual rare nuclear recoils induced by elastic scattering of WIMPs from our Galactic halo. I will discuss the background and the methods of rejecting it with the FID detectors. Detector performances and the first analysis of data acquired in a long-term campaign will be presented as well. The FID detector technology is not limited to EDELWEISS-III but can further be employed in the next generation of cryogenic detector experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Erratum to: Measurements of higher-order cumulants of multiplicity and net-electric charge distributions in inelastic proton-proton interactions by NA61/SHINE

This Erratum replaces, due to a discovery of coding mistakes, the following quantities: κ 3 /κ 1 of the h + − h − distribution presented in Fig. 6 and Table 6, κ 4 listed in Table 4, and $\hat{C}$ 4 presented in Fig. 7 and Table 5. All mentioned figures and tables were updated.

High-Energy Particle Collision Data Analysis↗

SCALE Code System 6.2.2

The SCALE Code System is a widely used modeling and simulation suite for nuclear safety analysis and design that is developed, maintained, tested, and managed by the Reactor and Nuclear Systems Division (RNSD) of Oak Ridge National Laboratory (ORNL). SCALE provides a comprehensive, verified and validated, user-friendly tool set for criticality safety, reactor physics, radiation shielding, radioactive source term characterization, and sensitivity and uncertainty analysis. Since 1980, regulators, licensees, and research institutions around the world have used SCALE for safety analysis and design. SCALE provides an integrated framework with dozens of computational modules including 3 deterministic and 3 Monte Carlo radiation transport solvers that are selected based on the desired solution strategy. SCALE includes current nuclear data libraries and problem-dependent processing tools for continuous-energy (CE) and multigroup (MG) neutronics and coupled neutron-gamma calculations, as well as activation, depletion, and decay calculations. SCALE includes unique capabilities for automated variance reduction for shielding calculations, as well as sensitivity and uncertainty analysis. SCALE’s graphical user interfaces assist with accurate system modeling, visualization of nuclear data, and convenient access to desired results. SCALE 6.2 represents one of the most comprehensive revisions in the history of SCALE, providing several new capabilities and significant improvements in many existing features.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE Code System

The SCALE Code System is a widely-used modeling and simulation suite for nuclear safety analysis and design that is developed, maintained, tested, and managed by the Reactor and Nuclear Systems Division (RNSD) of Oak Ridge National Laboratory (ORNL). SCALE provides a comprehensive, verified and validated, user-friendly tool set for criticality safety, reactor and lattice physics, radiation shielding, spent fuel and radioactive source term characterization, and sensitivity and uncertainty analysis. Since 1980, regulators, licensees, and research institutions around the world have used SCALE for safety analysis and design. SCALE provides an integrated framework with dozens of computational modules including three deterministic and three Monte Carlo radiation transport solvers that are selected based on the desired solution strategy. SCALE includes current nuclear data libraries and problem-dependent processing tools for continuous-energy (CE) and multigroup (MG) neutronics and coupled neutron-gamma calculations, as well as activation, depletion, and decay calculations. SCALE includes unique capabilities for automated variance reduction for shielding calculations, as well as sensitivity and uncertainty analysis. SCALE’s graphical user interfaces assist with accurate system modeling, visualization of nuclear data, and convenient access to desired results.

97 MATHEMATICS AND COMPUTING↗

SCALE Code System

The SCALE Code System is a widely used modeling and simulation suite for nuclear safety analysis and design that is developed, maintained, tested, and managed by the Reactor and Nuclear Systems Division (RNSD) of Oak Ridge National Laboratory (ORNL). SCALE provides a comprehensive, verified and validated, user-friendly tool set for criticality safety, reactor and lattice physics, radiation shielding, spent fuel and radioactive source term characterization, and sensitivity and uncertainty analysis. Since 1980, regulators, licensees, and research institutions around the world have used SCALE for safety analysis and design. SCALE provides an integrated framework with dozens of computational modules, including three deterministic and three Monte Carlo radiation transport solvers that are selected based on the desired solution strategy. SCALE includes current nuclear data libraries and problem-dependent processing tools for continuous-energy (CE) and multigroup (MG) neutronics and coupled neutron-gamma calculations, as well as activation, depletion, and decay calculations. SCALE includes unique capabilities for automated variance reduction for shielding calculations, as well as sensitivity and uncertainty analysis. SCALE’s graphical user interfaces assist with accurate system modeling, visualization of nuclear data, and convenient access to desired results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Use of limited data to construct Bayesian networks for probabilistic risk assessment.

Probabilistic Risk Assessment (PRA) is a fundamental part of safety/quality assurance for nuclear power and nuclear weapons. Traditional PRA very effectively models complex hardware system risks using binary probabilistic models. However, traditional PRA models are not flexible enough to accommodate non-binary soft-causal factors, such as digital instrumentation&control, passive components, aging, common cause failure, and human errors. Bayesian Networks offer the opportunity to incorporate these risks into the PRA framework. This report describes the results of an early career LDRD project titled %E2%80%9CUse of Limited Data to Construct Bayesian Networks for Probabilistic Risk Assessment%E2%80%9D. The goal of the work was to establish the capability to develop Bayesian Networks from sparse data, and to demonstrate this capability by producing a data-informed Bayesian Network for use in Human Reliability Analysis (HRA) as part of nuclear power plant Probabilistic Risk Assessment (PRA). This report summarizes the research goal and major products of the research.

Groth, Katrina M.↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

42 ENGINEERING↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Performing k eff Validation of As-Loaded Criticality Safety Calculations Using UNF-ST&DARDS: Applicable Experiment Selection

The general method for performing validation of as loaded criticality safety calculations using UNF ST&DARDS is presented in a paper by Clarity, which includes a description of the UNF-ST&DARDS system. Proof-of-principle analyses were performed in the summer of 2019 for MPC-32 dual purpose canisters (DPCs) containing pressurized water reactor (PWR) fuel assemblies. Summaries of these results are presented in this and a companion paper for this conference. The current paper describes the TSUNAMI-IP calculations performed to select applicable experiments for validation of 11 MPC-32 DPCs. The companion paper discusses the TSUNAMI-3D calculations used to generate sensitivity data to support the experiment selections discussed here. Experiment selection is based on the sensitivity/uncertainty (S/U) methods used to validate criticality safety calculations of as-loaded DPCs containing pressurized water reactor (PWR) spent nuclear fuel (SNF). This process has been demonstrated and is summarized in this paper. The approach is similar to that used in NUREG/CR-7109, which provides an approach for validation of PWR burnup credit (BUC), including major and minor actinides and major fission products. The premise of S/U-based validation is that applicable experiments—those having a similar bias to a given application system—will have similar sensitivities for each isotope and reaction in the two systems. It is assumed that cross sections with larger uncertainties are more likely to contain data errors which contribute to the bias. The integral index c k thus propagates the system sensitivities with the nuclear covariance data to calculate a correlation coefficient representing the similarity of the two systems. In this work, a c k value of 0.8 or higher is interpreted as identifying an experiment with sufficient similarity for use in validation. This paper presents a brief summary of the characteristics of the 11 MPC-32 DPCs used in the proof of-principle analysis for as-loaded criticality safety calculation validation and an overview of the critical experiment suite with which each of these DPC models was compared. A summary and discussion of c k results is also presented, followed by conclusions and a discussion of future work to be performed for validation of UNF ST&DARDS as-loaded criticality safety calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automation of Data Collection Methods for Online Monitoring of Nuclear Power Plants

Maintenance activities in the United States nuclear power industry are mainly centered on preventive and corrective maintenance. Predictive maintenance, which is a variable time basis maintenance strategy that is dependent on the condition of the equipment, is less utilized but potentially more effective. In the current maintenance practices, the nuclear power plants rely on manual processes to supply information to a human decision making process. The plants have several processes that generate information that is not typically used beyond the intended target for collecting that information. This information is a source of data that is manually collected by labor intensive tasks. The data is therefore expensive to collect, yet limited in use. The industry has realized the opportunity present in reducing the labor intensive tasks by automating them and increasing the uses of the data collected by either developing advanced predictive maintenance methods using data-driven decision making that could span from trending to machine learning and artificial intelligence. This shift in maintenance strategy may result in high cost saving impact. In addition to reducing labor requirements and frequency of maintenance activities, this shift in strategy will reduce the materials portion of the operations and maintenance cost as well. The aim of this specific effort is to focus on the automation of data collection process. It is part of a series of planned efforts to target multiple elements of migrating the current preventive maintenance approach in nuclear power plants to a data-driven approach. These elements include data collection, management, analysis, visualization, in addition to value analysis and change enabling. The other five elements of migration were not considered because they are planned to be explicitly studied in multiple parallel efforts. Challenges including regulations requirements or limitations are planned in a future effort that focuses on change enabling. The risk and benefit/cost of the approach shift is planned in another effort targeted towards value. The storage, communication, computational power, data architecture, and protection are part of the information infrastructure and are planned in dedicated data management effort. The best means to present the data for assisted human decision making is planned in a data visualization effort. The data interpretation and patterns recognition for machine decision making is planned through multiple efforts in data analytics over the following years. This work identified seventeen data sources collection methods in nuclear power plants that could be automated for an integrated data platform that enables comprehensive and informed decision making. For each of the identified seventeen data sources, the base, modern, and state of the art states were described. The current state of data collection used by most utilities was identified as the "base state". The current achievable state was identified as the "modern state", a state that has either been achieved by at least some US utilities or in other industries. The future state that requires research and development to reach was identified as the "state of the art" state. The described states used an out-of-the-box thinking approach. This effort found that there is a hug potential for task automation and data fidelity improvements by evolving the current industry data collection methods. The majority of the processes analyzed were found to be manual and labor intensive and fell in the base state. As a result, the modern state often targeted reducing the manual logging efforts by using electronic and semi-intelligent means or complementing the work with sensors and mobile or fixed technologies that can reduce the demand of labor activities. The state of the art state involved applications advanced methods of data correlation, data mining, and machine learning along with increasing the spatial distribution and fidelity of data, coupling multiple data sources, and enabling the use of sophisticated mobile devices and machine comprehension methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantization effects in radiation spectroscopy based on digital pulse processing

Radiation spectra represent inherently quantization data in the form of stacked channels of equal width. The spectrum is an experimental measurement of the discrete probability density function (PDF) of the detector pulse heights. The quantization granularity of the spectra depends on the total number of channels covering the full range of pulse heights. In analog pulse processing the total number of channels is equal to the total digital values produced by a spectroscopy analog-to-digital converter (ADC). In digital pulse processing each detector pulse is sampled and quantized by a fast ADC producing certain number of quantized numerical values. These digital values are linearly processed to obtain a digital quantity representing the peak of the digitally shaped pulse. Using digital pulse processing it is possible to acquire a spectrum with the total number of channels greater than the number of ADC values. Noise and sample averaging are important in the transformation of ADC quantized data into spectral quantized data. Analysis of this transformation is performed using an area sampling model of quantization. Spectrum differential nonlinearity (DNL) is shown to be related to the quantization at low noise levels and small number of averaged samples. Theoretical analysis and experimental measurements are used to obtain the condition to minimize the DNL due to quantization. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary cost and mission value comparisons for planetary probes delivered by advanced propulsion systems

The three advanced propulsion systems analyzed are an advanced chemical system, an improved solid-core nuclear rocket engine with a 25-kilowatt auxiliary powerplant, and a nuclear-electric system. The comparison of these systems is made on the basis of transportation cost divided by the expected value of the data returned to earth. The analysis shows that for the Mercury Orbiter mission and for missions to the outer planets with a high data requirement, the nuclear-electric system emerges as the best system. For the Venus Orbiter mission, the advanced chemical propulsion system is best.

Hrach, F. J.↗