Field Performance of Heat Pump Water Heaters in the Northeast, Massachusetts and Rhode Island (Fact Sheet)

Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publicly available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring, A.O. Smith Voltex, and Stiebel Eltron Accelera 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Performance of Heat Pump Water Heaters in the Northeast

Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publically available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring(TM), A.O. Smith Voltex(R), and Stiebel Eltron Accelera(R) 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation of thermal hydraulic performance of multiple parallel micropin arrays for concentrating solar thermal applications with supercritical carbon dioxide

Concentrated solar power (CSP) plants have the potential to provide 24 h, renewable electricity. Current CSP systems have high capital and operational costs which makes the levelized cost of electricity uncompetitive with conventional techniques. Recent experimental research has shown the potential of small unit cells (up to 2 × 2 cm) containing micropin arrays (D H < 1 mm) to operate efficiently at high incident flux (>140 W cm -2 ) using supercritical carbon dioxide as the working fluid. Applying this technology to CSP systems would result in a smaller central receiver, which would reduce thermal losses, increase receiver efficiency and reduce the capital cost of the receiver component. This study investigates and addresses the practical thermal and hydraulic issues in numbering up these small unit cells into numerous parallel cells within an integrated module design. A thermal hydraulic network model is developed to quantify the distribution and the overall receiver efficiency of an integrated module. This model is used to specify maximum allowable unit cell size and header dimensions to maintain acceptable thermal performance and pressure loss. Once a module design was finalized, parametric studies were performed to study the effects of varying incident flux on flow distribution and thermal performance of the module. Finally, the results show that an integrated module design can be achieved with less than 5% flow maldistribution and a pressure drop acceptable to the remainder of the system.

14 SOLAR ENERGY↗

Integration of Variable Generation and Cost-Causation (Fact Sheet)

Variable renewable energy generation sources, such as wind and solar energy, provide benefits such as reduced environmental impact, zero fuel consumption, and low and stable costs. Advances in both technologies can reduce capital costs and provide significant control capabilities. However, their variability and uncertainty - which change with weather conditions, time of day, and season - cancause an increase in power system operating costs compared to a fully controllable power plant. Although a number of studies have assessed integration costs, calculating them correctly is challenging because it is difficult to accurately develop a baseline scenario without variable generation that properly accounts for the energy value. It is also difficult to appropriately allocate costs giventhe complex, nonlinear interactions between resources and loads.

14 SOLAR ENERGY↗

Strategy for Safety-Related Digital I&C Qualification

Digital I&C qualification continues to be a major impediment to addressing the reliability and obsolescence issues of the legacy analog I&C systems of the operating LWR fleet. In particular, the issue of digital common cause failure (CCF) has been difficult to address and has been the reason that some nuclear plant licensees have deferred upgrades of these critical plant systems and have rather opted to maintain them with considerable engineering and maintenance efforts. This is getting more and more difficult in the face of declining analog technology suppliers and dwindling supplies of spare parts and support for many critical components. To remain a viable energy source for the nation, the nuclear fleet must reduce its operating costs to a competitive level. Digital technology is the foremost means of implementing performance improvements and cost reductions for this purpose. This has been demonstrated over and over again in other industry sectors, as well as in conventional generation facilities. However, due to the special nature of nuclear energy, these digital I&C qualification barriers remain and must be resolved in order to modernize these plants and transform the business model to one that is competitive. The purpose of this report is to present an assessment of digital I&C qualification issues and address gaps in qualification methods and processes that would potentially benefit from Department of Energy (DOE)-sponsored research and development. Two new qualification methods are described that are recommended for further Department of Energy-sponsored research and development. They are 1) Testability – the exhaustive (100%) testing of certain digital devices addressing all combinations of inputs and internal states, and 2) Elimination of CCF triggers – ensuring that any latent digital defects are not concurrently triggered in redundant and back-up safety systems. In addition this report presents a strategy for full nuclear plant modernization based on four interrelated elements that together address the remaining barriers to prudent implementation. These four elements are 1) End-State Architecture, 2) Cost-Benefit Analysis, 3) Regulatory Approval, and 4) Implementation Sequence Plan.

42 ENGINEERING↗

An economic model for evaluating high-speed aircraft designs

A Class 1 method for determining whether further development of a new aircraft design is desirable from all viewpoints is presented. For the manufacturer the model gives an estimate of the total cost of research and development from the preliminary design to the first production aircraft. Using Wright's law of production, one can derive the average cost per aircraft produced for a given break-even number. The model will also provide the airline with a good estimate of the direct and indirect operating costs. From the viewpoint of the passenger, the model proposes a tradeoff between ticket price and cruise speed. Finally all of these viewpoints are combined in a Comparative Aircraft Seat-kilometer Economic Index.

Vandervelden, Alexander J. M.↗

DSN co-observing operations to support space VLBI missions

Reliable radio astronomy support of space very long baseline interferometry (VLBI) missions by ground radio telescopes is mandatory in order to achieve a high scientific return from the missions. The 70 m DSN antennas along with other ground radio telescopes will perform as the ground segment of the earth-space interferometer. Improvements of radio astronomy VLBI operations at the DSN to achieve higher reliability, efficiency, flexibility, and lower operations costs is a major goal in preparing for radio astronomy support of SVLBI. To help realize this goal, a remote control and monitoring mode for radio astronomy operations at the DSN has been developed.

Altunin, Valery I.↗

Integrating Automation into a Multi-Mission Operations Center

NASA Goddard Space Flight Center's Space Science Mission Operations (SSMO) Project is currently tackling the challenge of minimizing ground operations costs for multiple satellites that have surpassed their prime mission phase and are well into extended mission. These missions are being reengineered into a multi-mission operations center built around modern information technologies and a common ground system infrastructure. The effort began with the integration of four SMEX missions into a similar architecture that provides command and control capabilities and demonstrates fleet automation and control concepts as a pathfinder for additional mission integrations. The reengineered ground system, called the Multi-Mission Operations Center (MMOC), is now undergoing a transformation to support other SSMO missions, which include SOHO, Wind, and ACE. This paper presents the automation principles and lessons learned to date for integrating automation into an existing operations environment for multiple satellites.

Surka, Derek M.↗

A Robust Load Shedding Strategy for Microgrid Islanding Transition

A microgrid is a group of interconnected loads and distributed energy resources. It can operate in either gridconnected mode to exchange energy with the main grid or run autonomously as an island in emergency mode. However, the transition of microgrid from grid-connected mode to islanded mode is usually associated with excessive load (or generation), which should be shed (or spilled). Under this condition, this paper proposes an robust load shedding strategy for microgrid islanding transition, which takes into account the uncertainties of renewable generation in the microgrid and guarantees the balance between load and generation after islanding. A robust optimization model is formulated to minimize the total operation cost, including fuel cost and penalty for load shedding. The proposed robust load shedding strategy works as a backup plan and updates at a prescribed interval. It assures a feasible operating point after islanding given the uncertainty of renewable generation. The proposed algorithm is demonstrated on a simulated microgrid consisting of a wind turbine, a PV panel, a battery, two distributed generators (DGs), a critical load and a interruptible load. Numerical simulation results validate the proposed algorithm.

Liu, Guodong↗

INL High-Performance and Sustainable Building Strategy

High-performance buildings are reliable, cost-effective, and sustainable structures that minimize energy and water use, reduce solid waste and pollutant emissions, and limit the depletion of natural resources while also providing a thermally and visually comfortable working environment that increases productivity for building occupants. As Idaho National Laboratory (INL) is the nation’s premier nuclear energy research laboratory, the physical infrastructure requires continual updating and re-purposing to help accomplish that mission. INL’s infrastructure must incorporate high-performance sustainable design features to be fiscally responsible and reflect an image of innovation to the public and prospective employees. INL is a large consumer of energy with annual energy costs exceeding $9M. In the current fiscal reality and with energy costs constantly increasing, this High-Performance and Sustainable Building Strategy will help engineering and construction project teams design facilities that are sustainable and will help to reduce life-cycle operating costs while providing INL employees with a safe and healthy working environment. With these goals in mind, the recommendations described in this document are intended to form INL’s foundation for sustainable and high-performance building standards. This strategy incorporates the latest federal and Department of Energy (DOE) orders and directives including Executive Order (EO) 13834, “Efficient Federal Operations” and its associated implementing instructions, DOE Order 436.1, “Departmental Sustainability,” the DOE Sustainability Report and Implementation Plan (SRIP), the INL Site Sustainability Plan (SSP), and Code of Federal Regulations (CFR). This document identifies the requirements of the Guiding Principles for Sustainable Federal Buildings (Guiding Principles) and briefly highlights the requirements of Leadership in Energy and Environmental Design (LEED®) Gold certification. LEED Gold certification, while optional, can be used to meet many of the requirements of the Guiding Principles.

13834↗

Techno-Economic Assessments of Second-Life Batteries for Electric Vehicle Charging Stations

When electric vehicle (EV) batteries degrade below a certain capacity, they may no longer be suitable for automotive use but can be repurposed as second-life batteries (SLBs) for other applications, such as EV charging stations. When integrated with photovoltaic (PV) systems, SLB can store surplus solar energy, reducing reliance on the grid and lowering operational costs. This paper presents a novel techno-economic assessment framework for deploying SLBs in combination with PV in grid-connected EV charging stations. The proposed framework integrates the value proposition, charging station operation, optimal dispatch strategies, battery degradation modeling, input data requirements, and detailed procedures for generating key economic performance metrics. Insightful analyses are performed to assess the performance of SLBs in comparison to new batteries across various cost scenarios. The results indicate that SLBs become financially attractive when their cost is 40% or lower than new batteries.

energy storage↗

Build-to-Replace Strategy to Reduce Operations and Maintenance Costs for Advanced Reactors

This paper targets the reduction of fixed operations and maintenance (O&M) costs for advanced reactor (AR) designs. This goal will be severely constrained if the underlying assumptions of O&M approaches and practices are not questioned and reexamined, especially today when changes can be implemented effectively and efficiently. Achieving a reduction in AR O&M costs requires a completely new way of thinking -a paradigm shift- not through incremental, technology-focused approaches alone. Here, we address this challenge by evaluating the impact of moving to a shorter design life for major structures, systems, and components and shorter, more predictable refurbishment cycles as modeled by the commercial airline industry: the build-to-replace approach. This paper provides a brief overview of this different mindset to O&M applied to ARs and it provided a set of analytical tools based on multi-objective optimization to identify the benefits of such an approach. In conclusion, we provide a direct example analysis of a build-to-replace scenario by identifying and evaluating scenarios for reduced system and component lifetimes and associated replacement and refurbishment schedules to evaluate impacts on O&M costs and other lifecycle elements, such as structure, system, and component reliability.

97 - MATHEMATICS AND COMPUTING↗

Torrefaction of almond shell as a renewable reinforcing agent for plastics: techno-economic analyses and comparison to bioethanol process

Abstract In 2016, the US state of California alone produced nearly 3.5 billion kilograms of almonds, accounting for approximately 84% of the world’s almond production. This generated about 2.58 million metric tons (MTs) of almond residues. Almond shells are currently either burned to generate power or disposed of in landfill. Valorizing almond shells and hulls provides an opportunity to replace petroleum-derived products and divert organic material from landfill. Here we demonstrate a detailed techno-economic analysis (TEA) of an almond shell torrefaction process capable of utilizing the 520 000 MTs of almond shells produced annually in California. Our process also includes preprocessing the torrefied biomass to exploit it as a reinforcing agent for plastics. We further compared the revenue generated from the torrefied biomass and bioethanol derived from the same quantity of almond shells. We considered three different torrefaction facility scales to evaluate trade-offs between economies of scale at the facility and trucking costs to deliver almond shells. A facility that takes in 200 000 MT yr –1 of almond shells results in lower per-unit-output basis capital and operating cost relative to other smaller-scale torrefaction facilities, including 10 000 MT yr –1 and 50 000 MT yr –1 , considered for analysis in this study. The large-sale facility results in a minimum selling price (MSP) of the torrefied biomass of $311.4 MT –1 . An analogous TEA on converting almond residues into bioethanol is also investigated. The MSP of almond shell derived ethanol ($1.71 kg −1 ) is higher than that of corn ($0.48 kg −1 ) or cellulosic biomass ($0.88 kg −1 ) derived ethanol. Compared with the bioethanol route, the torrefied almond shells result in three times more revenue if utilized as a reinforcing agent for plastics.

Liu, Dupeng (ORCID:0000000269514064)↗

Status Report on the Development of Micro-Scheduling Software for the Advanced Outage Control Center Project

The long-term viability of existing nuclear power plants (NPPs) in the United States (U.S.) is dependent upon a number of factors, including maintaining high capacity factors, maintaining nuclear safety, and reducing operating costs, particularly those associated with refueling outages. Refueling outages typically take 20-30 days, and for existing light water NPPs in the U.S., the reactor cannot be in operation during the outage. Furthermore, given that many NPPs generate between $1-1.5 million/day in revenue when in operation, there is considerable interest in shortening the length of refueling outages. Yet, refueling outages are highly complex operations, involving multiple concurrent and dependent activities that are difficult to coordinate. Finding ways to improve refueling outage performance while maintaining nuclear safety has proven to be difficult. The Advanced Outage Control Center project is a research and development (R&D) demonstration activity under the Light Water Reactor Sustainability (LWRS) Program. LWRS is a R&D program which works with industry R&D programs to establish technical foundations for the licensing and managing of long-term, safe, and economical operation of current NPPs. The Advanced Outage Control Center project has the goal of improving the management of commercial NPP refueling outages. To accomplish this goal, this INL R&D project is developing an advanced outage control center (OCC) that is specifically designed to maximize the usefulness of communication and collaboration technologies for outage coordination and problem resolution activities. This report describes specific recent efforts to develop a capability called outage Micro-Scheduling. Micro-Scheduling is the ability to allocate and schedule outage support task resources on a sub-hour basis. Micro-Scheduling is the real-time fine-tuning of the outage schedule to react to the actual progress of the primary outage activities to ensure that support task resources are optimally deployed with the least amount of delay and unproductive use of resources. The remaining sections of this report describe in more detail the scheduling challenges that occur during outages, how a Micro-Scheduling capability helps address those challenges, and provides a status update on work accomplished to date and the path forward.

99 GENERAL AND MISCELLANEOUS↗

Development of Improved Graphical Displays for an Advanced Outage Control Center, Employing Human Factors Principles for Outage Schedule Management

The long-term viability of existing nuclear power plants in the United States (U.S.) is dependent upon a number of factors, including maintaining high capacity factors, maintaining nuclear safety, and reducing operating costs, particularly those associated with refueling outages. Refueling outages typically take 20-30 days, and for existing light water NPPs in the U.S., the reactor cannot be in operation during the outage. Furthermore, given that many NPPs generate between $1-1.5 million/day in revenue when in operation, there is considerable interest in shortening the length of refueling outages. Yet refueling outages are highly complex operations, involving multiple concurrent and dependent activities that are somewhat challenging to coordinate; therefore, finding ways to improve refueling outage performance, while maintaining nuclear safety has proven to be difficult. The Advanced Outage Control Center (AOCC) project is a research and development (R&D) demonstration activity under the LWRS Program. LWRS is an R&D program that works closely with industry R&D programs to establish technical foundations for the licensing and managing of long-term, safe, and economical operation of current fleet of NPPs. As such, the LWRS Advanced Outage Control Center project has the goal of improving the management of commercial NPP refueling outages. To accomplish this goal, INL is developing an advanced outage control center (OCC) that is specifically designed to maximize the usefulness of communication and collaboration technologies for outage coordination and problem resolution activities. The overall focus is on developing an AOCC with the following capabilities that enables plant and OCC staff to; Collaborate in real-time to address emergent issues; Effectively communicate outage status to all workers involved in the outage; Effectively communicate discovered conditions in the field to the OCC; Provide real-time work status; Provide automatic pending support notifications; Provide real-time requirements monitoring; Maximize their collective situational awareness to improve decision-making; and Leverage macro data to better support resource allocation. INL has partnered with several commercial NPP utilities to develop a number of advanced outage management technologies. These outage management technologies have focused on both collaborative technologies for control centers and developing mobile technologies for NPP field workers. This report describes recent efforts made in developing a suite of outage technologies to support more effective schedule management. Currently, a master outage schedule is created months in advance using the plant’s existing scheduling software (e.g., Primavera P6). Typically, during the outage, the latest version of the schedule is printed at the beginning of each shift. INL and its partners are developing technologies that will have capabilities such as Automatic Schedule Updating, Automatic Pending Support Notifications, and the ability to allocate and schedule outage support task resources on a sub-hour basis (e.g., outage Micro-Scheduling). The remaining sections of this report describe in more detail the scheduling challenges that occur during outages, how the outage scheduling technologies INL is developing helps address those challenges, and the latest developments on this task (e.g., work accomplished to date and the path forward)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Prototype Ceramic High Efficiency Particulate Air Filter Testing and Filter Media Development for Nuclear Facility Ventilation

This report summarizes recent and past related Ceramic HEPA Filter activity for this NNSA NSR&D project and on-going plans for FY18 and FY19 work as presently planned. Prior work has evaluated concepts for a ceramic HEPA filter including ceramic support materials, filter media including electrospun filter media, and metal housing designs to accommodate the conservative temperature performance target of up to 500°C. This has been supported by modelling efforts discussed with nuclear facility system engineers and their management. The temperature and time-at-temperature are based on conservative, bounding temperatures from fire analysis presented as a draft EFCOG best practice paper for nuclear facility safety analysis. The overall goal is to improve safety of DOE nuclear facilities during fire scenarios by developing improved filtration technology including increasing performance while reducing pressure drop. Ceramic filtration technology can provide robust, passive mitigation against radiological releases. The goal of the ceramic HEPA filter is to provide a robust HEPA filter that provides increased temperature performance in an equivalent form factor (size and shape) that is similar to existing conventional HEPA filters used in facilities. Once qualified for use in facilities, the benefit of a ceramic HEPA filters could simplify and reduce safety and support system costs, as well as considerably lower life-cycle costs. Installation, monitoring, and maintenance of active fire suppression systems, as well as other related systems, are a considerable on-going cost to nuclear facilities. Reducing the level of dependence on Safety Class and Safety Significant fire alarm and fire suppression systems could allow significant cost savings. At present we are continuing research and development efforts towards the goal of a ceramic filter design, including improved ceramic filter media, that could reduce total operation cost for facilities utilizing HEPA filters.

42 ENGINEERING↗