Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIXELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Target Optimal Aperture Selection

This document describes the computation of optimal pixels for planetary transit targets. The method we describe is based on that used in the End-to-End Model (ETEM), which simulates Kepler science output. An optimal aperture for a target is defined as the set of pixels which maximizes the signal-to-noise ratio (SNR) for that target. The optimal aperture for a target is determined by using catalog data to generate, for that target, a synthetic image with all background stars and signals and a second synthetic image with the target star's flux only. These images are incorporated into a noise model, from which the SNR of each pixel is computed. The pixels around a target are summed in an order that maximizes the SNR with each term. As dimmer and dimmer pixels contribute to this sum, the SNR reaches a maximum and further terms decrease the SNR. The set of pixels whose SNR sums to this maximum value defines the optimal aperture.

Bryson, Stephen↗

Measuring Electron Temperature Using a Linear Polarizer Versus a Polarization Camera

Polarized K-coronal brightness (pB) of the solar corona can be measured by taking four successive coronal brightness images through a linear polarizer, by turning it through four successive angles in intervals of 45∘ and using a standard formula to measure pB from the total coronal brightness (TB) that contains both the polarized K- and the unpolarized F-coronal brightness. The question is: will the time-dependent, highly dynamic corona illuminate each pixel with the same brightness during the time it takes to take the four successive images? To mitigate this problem we now have the polarization camera, in which, each super-pixel is made up of four sub-pixels, and built in to these four sub-pixels is a polarization mask that contains four linear polarizers orientated at four angles 45∘ apart. This allows the measurement of pB to be made in a single exposure. Here, the question is: will the variations of the coronal brightness in the four adjacent sub-pixels in a super-pixel be sufficiently negligible to assume that they observe the same part of the corona? This article looks for answers to these two questions by conducting two synthetic experiments to measure the electron temperature in the plane of the sky on a spherically asymmetric model (SAM) corona by first using a linear polarizer, and then replacing it with a polarization camera and use statistical analyses to determine how well the measured temperature matched the true temperature for the two cases.

Reginald, Nelson↗

Detecting Nighttime Fire Combustion Phase by Hybrid Application of Visible and Infrared Radiation from Suomi NPP VIIRS

An accurate estimation of biomass burning emissions is 1 partially limited by the lack of knowledge of fire burning phase (smoldering vs. flaming). In recent years, several fire detection products have been developed to provide information of fire radiative power (FRP), location, size, and temperature of fire pixels, but no information regarding fire burning phase is retrieved. The Day-Night band (DNB) aboard Visible Infrared Imaging Radiometer Suite (VIIRS) is sensitive to visible light from flaming fires in nighttime scenes. In contrast, VIIRS 4 m moderate resolution band #13 (M13), though capable of detecting fires at all phases, has no direct sensitivity for discerning fire phase. However, the hybrid usage of VIIRS DNB and M-bands data is hampered by their different scanning technology and spatial resolution. In this study, we present a novel method to rapidly and accurately resample DNB pixel radiances to the footprint of M-band pixels, accounting for onboard detector aggregation schemes and bowtie effect removals. The visible energy fraction (VEF) is subsequently introduced as an indicator of fire burning phase VEF is calculated as the ratio of visible light power (VLP) to FRP for each fire pixel retrieved from the VIIRS 750 m active fire product. A global distribution of VEF values, and thereby the fire phase, is quantitatively obtained, showing smaller VEF values in regions with mostly smoldering wildfires, such as peatland fires in Indonesia, larger VEF values in regions with flaming wildfires over grasslands and savannas in the sub-Sahelian region, and the largest VEF values associated with gas flaring in the Middle East. Mean VEF for different land cover types or regions is highly correlated with modified combustion efficiency (MCE). These results, together with a case study of the 2018 California Camp Fire, show that the VEF has the potential to be an indicator of fire combustion phase for each fire pixel, appropriate for estimating emission factors at the satellite pixel level.

Jun Wang↗

Sensor Chip Assembly (SCA) Test Report

This report summarizes the measured performance for the Sensor Chip Assembly (SCA), which is identified in Table 1. The SCA architecture is a substrate-removed HgCdTe detector with an area of 4096x4096 pixels (with a reference pixel area of four pixels deep around all four sides, available to substitute corresponding image pixels) and a pixel pitch of 10 μm. This SCA has been tested at the Goddard Space Flight Center (GSFC/NASA) Detector Characterization Laboratory (DCL). Teledyne (the vendor) classifies its detectors into different grades based on testing performed at its facility. The classification of this SCA and the tested dates are included in Table 1 below. The tests performed on this array are derived from the document WFIRST-PROC-09220_WFIRST-SCA-ATP_-.docx. A summary of the test parameters, requirements, and test results is presented in Table 2. The details of each test are subsequently described in the report. In the Summary (Table 2), SCA results are reported at an operating temperature of 95K, and 1.0 V bias voltage. In the detailed section of each test, the results for 90 K (1.0V bias voltage) and 95 K (0.5V bias voltage) are also reported. For all cases, the frame time used is 2.764 seconds. Reference pixel correction was applied to every raw frame.

WFIRST SCA TEST REPORT↗

SCA Test Report: H4RG-20828 WFIRST

This report summarizes the measured performance for the Sensor Chip Assembly (SCA), which is identified in Table 1. The SCA architecture is a substrate-removed HgCdTe detector with an area of4096x4096 pixels (with a reference pixel area of four pixels deep around all four sides, available to substitute corresponding image pixels) and a pixel pitch of 10 μm. This SCA has been tested at the Goddard Space Flight Center (GSFC/NASA) Detector Characterization Laboratory (DCL). Teledyne (the vendor) classifies its detectors into different grades based on testing performed at its facility. The classification of this SCA and the tested dates are included in Table 1 below.The tests performed on this array are derived from the document WFIRST-PROC-09220_WFIRST-SCA-ATP_-.docx. A summary of the test parameters, requirements, and test results is presented in Table 2. The details of each test are subsequently described in the report. In the Summary (Table 2), SCA results are reported at an operating temperature of 95K, and 1.0 V bias voltage. In the detailed section of each test, the results for 90 K (1.0V bias voltage) and 95 K (0.5V bias voltage) are also reported. For all cases, the frame time used is 2.764 seconds. Reference pixel correction was applied to every raw frame.

Laddawan Miko↗

SCA Test Report, H4RG-20829 WFIRST

This report summarizes the measured performance for the Sensor Chip Assembly (SCA), which is identified in Table 1. The SCA architecture is a substrate-removed HgCdTe detector with an area of 4096x4096 pixels (with a reference pixel area of four pixels deep around all four sides, available to substitute corresponding image pixels) and a pixel pitch of 10 μm. This SCA has been tested at the Goddard Space Flight Center (GSFC/NASA) Detector Characterization Laboratory (DCL). Teledyne (the vendor) classifies its detectors into different grades based on testing performed at its facility. The classification of this SCA and the tested dates are included in Table 1 below. The tests performed on this array are derived from the document WFIRST-PROC-09220_WFIRST-SCA-ATP_-.docx. A summary of the test parameters, requirements, and test results is presented in Table 2. The details of each test are subsequently described in the report. In the Summary (Table 2), SCA results are reported at an operating temperature of 95K, and 1.0 V bias voltage. In the detailed section of each test, the results for 90 K (1.0V bias voltage) and 95 K (0.5V bias voltage) are also reported. For all cases, the frame time used is 2.764 seconds. Reference pixel correction was applied to every raw frame.

Laddawan R Miko↗

SCA Test Report: H4RG-20833 WFIRST

This report summarizes the measured performance for the Sensor Chip Assembly (SCA), which is identified in Table 1. The SCA architecture is a substrate-removed HgCdTe detector with an area of 4096x4096 pixels (with a reference pixel area of four pixels deep around all four sides, available to substitute corresponding image pixels) and a pixel pitch of 10 μm. This SCA has been tested at the Goddard Space Flight Center (GSFC/NASA) Detector Characterization Laboratory (DCL). Teledyne (the vendor) classifies its detectors into different grades based on testing performed at its facility. The classification of this SCA and the tested dates are included in Table 1 below.The tests performed on this array are derived from the document WFIRST-PROC-09220_WFIRST-SCA-ATP_-.docx. A summary of the test parameters, requirements, and test results is presented in Table 2. The details of each test are subsequently described in the report. In the Summary (Table 2), SCA results are reported at an operating temperature of 95K, and 1.0 V bias voltage. In the detailed section of each test, the results for 90 K (1.0V bias voltage) and 95 K (0.5V bias voltage) are also reported. For all cases, the frame time used is 2.764 seconds. Reference pixel correction was applied to every raw frame.

Laddawan Miko↗

SCA Test Report: H4RG-20849 WFIRST

This report summarizes the measured performance for the Sensor Chip Assembly (SCA), which is identified in Table 1. The SCA architecture is a substrate-removed HgCdTe detector with an area of 4096x4096 pixels (with a reference pixel area of four pixels deep around all four sides, available to substitute corresponding image pixels) and a pixel pitch of 10 μm. This SCA has been tested at the Goddard Space Flight Center (GSFC/NASA) Detector Characterization Laboratory (DCL). Teledyne (the vendor) classifies its detectors into different grades based on testing performed at its facility. The classification of this SCA and the tested dates are included in Table 1 below. The tests performed on this array are derived from the document WFIRST-PROC-09220_WFIRST-SCA-ATP_-.docx. A summary of the test parameters, requirements, and test results is presented in Table 2. The details of each test are subsequently described in the report. In the Summary (Table 2), SCA results are reported at an operating temperature of 95K, and 1.0 V bias voltage. In the detailed section of each test, the results for 95 K and 0.5V bias voltage is also reported. For all cases, the frame time used is 2.764 seconds. Reference pixel correction was applied to every raw frame.

Laddawan Miko↗

Fine Optimization of TES Design for the X-IFU Instrument on ATHENA

The X-ray Integral Field Unit (X-IFU) instrument on the Advanced Telescope for High ENergy Astrophysics (ATHENA) is baselined to have 3168 transition-edge sensor (TES) microcalorimeter pixels. These pixels will be DC biased and readout using time division multiplexing. We recently reported a demonstration of the required pixel and readout performance in 252 pixels from a 1 kilo-pixel array (e.g. 2.16 eV resolution for 6.9 keV X-rays). Having achieved the required performance, the 50um square TES design in this demonstration array is considered the baseline pixel design for X-IFU. However, by making small adjustments to the TES design, we may be able to make small but consequential improvements to the instrument performance, while staying within the many constraints of the X-IFU requirements. In this presentation, we will show results from newly fabricated devices with subtle changes from the baseline TES design to further optimize the performance for X-IFU. We will discuss optimizing the TES sheet resistance, normal metal features, X-ray absorber attachment points, TES aspect ratio, and heat capacity. These minor design changes can have significant effects on thermo-electric time constants, thermal fluctuation noise, resistive transition shape and uniformity, and non-linearity of X-ray event pulses. In addition, full characterization of these new TES designs allows greater understanding of the relevant physics within the TES and gives routes for further optimization.

Nick Wakeham↗

Probabilistic Processing of Asynchronous Geiger-Mode Avalanche Photodiode Arrays for Background Rate Measurements

A system-level performance evaluation of Geiger-mode avalanche photodiode (GmAPD) arrays requires accurate measurement and prediction of the background rate of the device due to dark counts and other spurious detection events. Since a GmAPD detector reports only a binary value and timestamp associated with an avalanche event, dark count rates are typically measured by averaging thousands of frames to support a statistically significant measurement. For both synchronous and asynchronous detector, the Poisson distributed background rates are referenced to the time each pixel is armed. Unlike for synchronous GmAPD imagers where all the pixels are armed to an array-wide arm signal, an asynchronous pixel operates independently from its neighboring pixels; requiring the background rates to be calculated using an interarrival histogram. For both types of imagers, the background rate is typically evaluated by fitting an exponential distribution to a fixed window within a measured histogram of time intervals between detection events However, if the statistics of the background rate are insufficient – whether that is due to low population sizes, saturation, or a large dynamic range of population size across the array, the pixel, or array-wide, performance metrics may report results with varying accuracy. This paper reports on an implementation of an algorithm that evaluates GmAPD background rates based on statistical metrics rather than fixed windows. The algorithm functions by determining the appropriate integration window within the interarrival time histogram based on a per-pixel count rate set by a predetermined tolerable measurement error. The implementation of the algorithm allows us to characterize GmAPD arrays with orders of magnitude spread in background rates across the detector using common statistical parameters.

Mumolo, J.↗

A New Machine Learning Based Analysis for Improving Satellite Retrieved Atmospheric Composition Data: OMI SO2 as an Example

Despite recent progress, satellite retrievals of anthropogenic SO2 still suffer from relatively low signal-tonoise ratios. In this study, we demonstrate a new machine learning data analysis method to improve the quality of satellite SO2 products. In the absence of large ground-truth datasets for SO2, we start from SO2 slant column densities (SCDs) retrieved from the Ozone Monitoring Instrument (OMI) using a data-driven, physically based algorithm and calculate the ratio between the SCD and the root mean square (rms) of the fitting residuals for each pixel. To build the training data, we select presumably clean pixels with small SCD / rms ratios (SRRs) and set their target SCDs to zero. For polluted pixels with relatively large SRRs, we set the target to the original retrieved SCDs. We then train neural networks (NNs) to reproduce the target SCDs using predictors including SRRs for individual pixels, solar zenith, viewing zenith and phase angles, scene reflectivity, and O3 column amounts, as well as the monthly mean SRRs. For data analysis, we employ two NNs: (1) one trained daily to produce analyzed SO2 SCDs for polluted pixels each day and (2) the other trained once every month to produce analyzed SCDs for less polluted pixels for the entire month. Test results for 2005 show that our method can significantly reduce noise and artifacts over background regions. Over polluted areas, the monthly mean NN-analyzed and original SCDs generally agree to within ±15 %, indicating that our method can retain SO2 signals in the original retrievals except for large volcanic eruptions. This is further confirmed by running both the NN-analyzed and original SCDs through a topdown emission algorithm to estimate the annual SO2 emissions for ∼ 500 anthropogenic sources, with the two datasets yielding similar results. We also explore two alternative approaches to the NN-based analysis method. In one, we employ a simple linear interpolation model to analyze the original SCD retrievals. In the other, we develop a PCA–NN algorithm that uses OMI measured radiances, transformed and dimension-reduced with a principal component analysis (PCA) technique, as inputs to NNs for SO2 SCD retrievals. While the linear model and the PCA–NN algorithm can reduce retrieval noise, they both underestimate SO2 over polluted areas. Overall, the results presented here demonstrate that our new data analysis method can significantly improve the quality of existing OMI SO2 retrievals. The method can potentially be adapted for other sensors and/or species and enhance the value of satellite data in air quality research and applications.

Can Li↗

Geometric Assessment of PlanetScope Imagery

Commercial companies such as Maxar, Planet Labs, and BlackSky have built large archives of high resolution (1-3 m) Earth observing data. The high temporal resolution and global coverage of these satellites makes commercial satellite images ideal for scientists studying rapidly changing processes such as flooding and fires. The high spatial resolution allows scientists to push studies to a fine scale such as monitoring agricultural growth experiments or detecting vehicles for traffic management. Scientists using these data need to know geolocation accuracy, band-to-band registration (BBR), and pixel footprint size to best determine appropriate applications as well as what extra steps they will need to take to use the data. Here, we find those key geometric properties for images from Planet Labs’ SuperDove constellation. Geolocation accuracy is assessed relative to WorldView images at globally distributed cities, band-to-band registration (BBR) is examined for every image we acquired (200+ images), and pixel footprint sizes are calculated from edge responses of the images over Cal/Val sites in China, India, or USA both near launch time and 1+ years after launch. We find that SuperDove geolocation is highly self-consistent with average global offsets among SuperDove images of 3.80 m (1.27 pixels). Despite this self-consistency, relative geolocation accuracy (with WorldView images as reference) varies by location from 3.20 m – 28.09 m mean offset. SuperDove BBR is sub-pixel and varies by band, with a mean radial offset relative to red band varying from 0.39 - 1.13 m. SuperDove image footprint size improves after 1+ years in orbit, with an average footprint size of 3.41 pixels (10.24 m) soon after launch and 3.23 pixels (9.7 m) 1+ years after launch. The BBR and self-consistency offsets are relatively small, given the large footprint sizes. A similarly extensive investigation is in progress for Planet Labs’ Dove-R series.

Alana G. Semple↗

Method to improve cancerous lesion detection sensitivity in a dedicated dual-head scintimammography system

An improved method for enhancing the contrast between background and lesion areas of a breast undergoing dual-head scintimammographic examination comprising: 1) acquiring a pair of digital images from a pair of small FOV or mini gamma cameras compressing the breast under examination from opposing sides; 2) inverting one of the pair of images to align or co-register with the other of the images to obtain co-registered pixel values; 3) normalizing the pair of images pixel-by-pixel by dividing pixel values from each of the two acquired images and the co-registered image by the average count per pixel in the entire breast area of the corresponding detector; and 4) multiplying the number of counts in each pixel by the value obtained in step 3 to produce a normalization enhanced two dimensional contrast map. This enhanced (increased contrast) contrast map enhances the visibility of minor local increases (uptakes) of activity over the background and therefore improves lesion detection sensitivity, especially of small lesions.

60 APPLIED LIFE SCIENCES↗

Variable waveband infrared imager

A waveband imager includes an imaging pixel that utilizes photon tunneling with a thermally actuated bimorph structure to convert infrared radiation to visible radiation. Infrared radiation passes through a transparent substrate and is absorbed by a bimorph structure formed with a pixel plate. The absorption generates heat which deflects the bimorph structure and pixel plate towards the substrate and into an evanescent electric field generated by light propagating through the substrate. Penetration of the bimorph structure and pixel plate into the evanescent electric field allows a portion of the visible wavelengths propagating through the substrate to tunnel through the substrate, bimorph structure, and/or pixel plate as visible radiation that is proportional to the intensity of the incident infrared radiation. This converted visible radiation may be superimposed over visible wavelengths passed through the imaging pixel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System and method for detecting high-energy photons

A system for detecting high-energy photons includes a pixelated image detector exposed to visible light and high-energy photons, and the pixelated image detector generates one or more images from the exposure to the visible light and high-energy photons. The system further includes one or more processors operably connected to the pixelated image detector and configured to perform operations on the one or more images to discriminate between visible light and high-energy photons. A method for detecting high-energy photons includes exposing a pixelated image detector to visible light and high-energy photons and discriminating between the visible light that interacts with the pixelated image detector and the high-energy photons that interact with the pixelated image detector.

Gibbs, Kenneth M.↗

Method to improve cancerous lesion detection sensitivity in a dedicated dual-head scintimammography system

An improved method for enhancing the contrast between background and lesion areas of a breast undergoing dual-head scintimammographic examination comprising: 1) acquiring a pair of digital images from a pair of small FOV or mini gamma cameras compressing the breast under examination from opposing sides; 2) inverting one of the pair of images to align or co-register with the other of the images to obtain co-registered pixel values; 3) normalizing the pair of images pixel-by-pixel by dividing pixel values from each of the two acquired images and the co-registered image by the average count per pixel in the entire breast area of the corresponding detector; and 4) multiplying the number of counts in each pixel by the value obtained in step 3 to produce a normalization enhanced two dimensional contrast map. This enhanced (increased contrast) contrast map enhances the visibility of minor local increases (uptakes) of activity over the background and therefore improves lesion detection sensitivity, especially of small lesions.

60 APPLIED LIFE SCIENCES↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Texture analysis of placental MRI: can it aid in the prenatal diagnosis of placenta accreta spectrum?

Purpose: To determine if texture analysis can differentiate placenta accreta spectrum (PAS) from normal placenta on MRI. Methods: We performed retrospective image analysis of 80 patients, comprised of 46 patients with PAS and 34 patients without PAS. Histopathology was used as the reference standard. Sagittal single shot fast spin echo T2-weighted MRI sequences acquired from a single institution were analyzed. Placental heterogeneity was quantified using in-house software on a Matlab platform, including the standard deviation of pixel intensity, coefficient of variation, gray-level co-occurrence matrices (GLCM), histogram-oriented gradients (HOG), and fractal analysis with box sizes from 2 to 512. Two-tailed unpaired Student’s t test was used with statistical significance of p < 0.05. Results: PAS was associated with higher values for standard deviation of pixel intensity and fractal analysis at every box size. Fractal analysis at box sizes 256 (p = 0.011) and 32 (p = 0.021), and standard deviation of pixel intensity (p = 0.023) were the most statistically significant. Fractal values at box size 256 for PAS was 0.13 versus 0.090 for patients without PAS, while standard deviation of pixel intensity was 3.7 for PAS versus 2.5 for patients without PAS. No statistically significant association between PAS and GLCM, coefficient of variation, and HOG was found. Conclusion: Statistically significant differences were found between normal and abnormal groups using standard deviation of pixel intensity and fractal analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗