Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Scalable Preconditioning of Block-Structured Linear Algebra Systems using ADMM

In this paper, we study the solution of block-structured linear algebra systems arising in optimization by using iterative solution techniques. These systems are the core computational bottleneck of many problems of interest such as parameter estimation, optimal control, network optimization, and stochastic programming. Our approach uses a Krylov solver (GMRES) that is preconditioned with an alternating method of multipliers (ADMM). We show that this ADMM-GMRES approach overcomes well-known scalability issues of Schur complement decomposition in problems that exhibit a high degree of coupling. The effectiveness of the approach is demonstrated using linear systems that arise in stochastic optimal power flow problems and that contain up to 2 million total variables and 4,000 coupling variables. We find that ADMM-GMRES is nearly an order of magnitude faster than Schur complement decomposition. Moreover, we demonstrate that the approach is robust to the selection of the augmented Lagrangian penalty parameter, which is a key advantage over the direct use of ADMM.

97 MATHEMATICS AND COMPUTING↗

Laser-Assisted Synthesis of Monolayer 2D MoSe 2 Crystals with Tunable Vacancy Concentrations: Implications for Gas and Biosensing

We report tuning the structural and electronic properties of atomically thin two-dimensional (2D) materials via defect and vacancy engineering is the key to enabling their potential use in various applications, including electronics, energy, and sensing devices. Vacancies are, for instance, becoming highly promising for the enhanced interaction of gases and biomolecules with 2D materials in energy and sensing applications. However, the deterministic generation of desirable vacancies with tunable concentrations remains a challenge in 2D materials due to the limitations in the current growth methods, such as the complex reaction chemistries and gas flow dynamics. Therefore, engineering defects and vacancies in 2D materials have been mainly limited to destructive top-down processes such as heating, ion bombardments, and laser postprocessing. Here, we introduce a single-step bottom-up synthesis approach for the growth of monolayer MoSe 2 crystals with tunable vacancy concentrations. This method utilizes the spatiotemporal properties and adjustable power densities of the lasers to control the vaporization dynamics of the stoichiometric MoSe 2 powders. Such a mechanism in the vaporization allows us to grow tunable stoichiometry monolayer MoSe 2–x crystals on the substrates. The localized and time-controlled (250 ms to 2 s) vaporization of the MoSe 2 powder by a CO 2 laser enables the formation of monolayer crystals with controlled vacancy concentrations ranging from ~1 to 20%. The effects of laser power, laser irradiation time, and background pressure on the tuning range and subsequent properties of the crystals are investigated and quantified using Raman and photoluminescence spectroscopy, scanning transmission electron microscopy (STEM), and time-correlated single-photon counting (TCSPC). This bottom-up synthesis is a promising approach that allows the deterministic vacancy tuning for future electronics and, in particular, gas and biosensing applications without the need for further postprocessing and potential structural disruption of the crystals.

2D materials↗

Multi-Element Water Content System Instrument Handbook

The SEA Model WCM-2000 multi-element water content system was designed to provide aircraft and wind tunnel users with a single, rugged sensor to simultaneously measure liquid water content (LWC), total water content (TWC), and ice water content (IWC). The instrument consists of four heated stainless steel elements, each with a different shape or size. Each element is directly heated by low-voltage DC current flowing through the element. These elements are maintained at a constant temperature, typically 140°C, by a digital closed-loop control system. Three of the heated elements are exposed directly to the airstream and incoming cloud water. A fourth element, the reference/comp element, is arranged to be exposed to the airflow but not to incoming cloud water. This element is used to establish the “dry power term” that is subtracted from the other three elements’ power readings to establish the measured water content.

54 ENVIRONMENTAL SCIENCES↗

Full-Loop Simulation of the Combustion of Biomass in a Circulating Fluidized Bed Combustor

Interest in circulating fluidized bed (CFB) boilers as a power generation technology has skyrocketed in recent years because of several advantages this technology offers over conventional boilers, such as increased gas-solid mixing, which results in higher combustion efficiency, and the ability to use lower rank fuels. CFB combustors are operated at lower temperatures than conventional thermal power generation combustors, thus reducing NO x emissions, while SO 2 emissions can be conveniently controlled through the addition of Ca-based sulfur sorbents within the combustor. This report summarizes the development of a comprehensive computational fluid dynamics (CFD) model for biomass combustion in a 50 kW th CFB combustor employing the multiphase particle-in-cell (PIC) approach in the open-source Multiphase Flow with Interphase eXchanges (MFiX) Software Suite at the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL). The experimental combustor was designed, built, and operated at CanmetENERGY, Natural Resources Canada in Ottawa, Canada. This work is the culmination of a multi-year collaboration between NETL and CanmetENERGY. The hydrodynamics in the full loop are validated against cold-flow experiments conducted at CanmetENERGY. To mimic the dense packing in the standpipe in the absence of a collisional model in the MFiX-PIC approach, the ram valve in the return leg is partially closed to obstruct the flow. A combustion reaction scheme was developed that considers the volatiles released by the fuel as a lumped species that fully converts to CO 2 and H 2 O. The so-called enhanced simplified combustion scheme produces an excellent match with experimental data in terms of the species concentrations of CO 2 and O 2 at the outlet and the freeboard, demonstrating the utility of the comprehensive model for a range of flow conditions and operating temperatures. Furthermore, the model can be readily adapted to simulate combustion of a variety of biomass fuels as well as co-fired systems under air and oxy-fuel conditions.

09 BIOMASS FUELS↗

Dynamic simulation and load-following control of an integrated gasification combined cycle (IGCC) power plant with CO{sub 2} capture

Load-following control of future integrated gasification combined cycle (IGCC) plants with pre-combustion CO{sub 2} capture is expected to be far more challenging as electricity produced by renewable energy is connected to the grid and strict environmental limits become mandatory requirements. To study control performance during load following, a plant-wide dynamic simulation of a coal-fed IGCC plant with CO{sub 2} capture has been developed. The slurry-fed gasifier is a single-stage, downward-fired, oxygen-blown, entrained-flow type with a radiant syngas cooler (RSC). The syngas from the outlet of the RSC goes to a scrubber followed by a two-stage sour shift process with inter-stage cooling. The acid gas removal (AGR) process is a dual-stage physical solvent-based process for selective removal of H{sub 2}S in the first stage and CO{sub 2} in the second stage. Sulfur is recovered using a Claus unit with tail gas recycle to the AGR. The recovered CO{sub 2} is compressed by a split-shaft multistage compressor and sent for sequestration after being treated in an absorber with triethylene glycol for dehydration. The clean syngas is sent to two advanced “F”-class gas turbines (GTs) partially integrated with an elevated-pressure air separation unit. A subcritical steam cycle is used for heat recovery steam generation. A treatment unit for the sour water strips off the acid gases for utilization in the Claus unit. The steady-state model developed in Aspen Plus® is converted to an Aspen Plus Dynamics® simulation and integrated with MATLAB® for control studies. The results from the plant-wide dynamic model are compared qualitatively with the data from a commercial plant having different configuration, operating condition, and feed quality than what has been considered in this work. For load-following control, the GT-lead with gasifier-follow control strategy is considered. A modified proportional–integral–derivative (PID) control is considered for the syngas pressure control. For maintaining the desired CO{sub 2} capture rate while load-following, a linear model predictive controller (LMPC) is implemented in MATLAB®. A combined process and disturbance model is identified by considering a number of model forms and choosing the final model based on an information-theoretic criterion. The performance of the LMPC is found to be superior to the conventional PID control for maintaining CO{sub 2} capture rates in an IGCC power plant while load following.

01 COAL, LIGNITE, AND PEAT↗

Light-triggered electrochemical biosensor using singlet oxygen for self-powered operation and glucose detection

This study introduces a light-activated sensing strategy that integrates photosensitization with electrochemical detection. The sensor employs Eosin Y, a photosensitizer that generates singlet oxygen ( 1 O 2 ) via type II photosensitization. Immobilized within a thin polymer matrix on a carbon working electrode, Eosin Y produces 1 O 2 , under green light (520 nm) illumination, initiating a redox process that yields a measurable current. To incorporate biosensing capabilities and enable self-powered operation, this 1 O 2 – mediated process was coupled with glucose oxidase (GOx) to construct a fully operational glucose biosensor. The addition of glucose reverses the current flow by causing GOx to compete for electrons, with the resulting current magnitude correlating with glucose concentration providing a sensitive measure of glucose. The biosensor, as proof-of-principle, demonstrated excellent performance over a range of glucose concentrations (0–73 mM), achieving a detection limit (LOD) of 2.8 mM for steady state photocurrent under oxygen-saturated conditions. This platform leverages light and 1 O 2 as stimuli for tunable, on-demand signal control, offering a novel approach for adaptive, real-time biosensing technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of an urea decomposition chamber using CFD and VR

Selective Catalytic Reduction (SCR) is an important air pollution control process that consists of injecting ammonia (NH 3 ) into the boiler flue gas and passing the flue gas through a catalyst bed where the NO x and NH 3 react to form nitrogen gas (N 2 ) and water vapor (H 2 O). At a coal-fired power station, a decomposition chamber uses combustion air and a natural gas burner to provide the necessary temperature, air flow and pressure to convert the injected urea solution into ammonia gas. Inspections of this decomposition chamber indicate debris formations occurring at the burner/roof prevent the chamber from achieving proper temperature for conversion and redirect the burner flame/flow, which can potentially shift the flow pattern in the chamber. In order to identify the cause of this debris formation, Computational Fluid Dynamics (CFD) and Virtual Reality (VR) have been employed to simulate and visualize the flow distribution and species concentration inside this decomposition chamber. Furthermore, by analyzing the simulation data, excessive ammonia recirculation have been identified as the cause of the debris formation at the top of the chamber. We have also conduced the parametric studies in order to optimize the existing chamber design by introducing multiple baffles to eliminate the excessive recirculation, thus minimizing debris formation.

42 ENGINEERING↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Experimental characterization of a triply periodic minimal surface PCM-to-air thermal energy storage device

Here, the expansion of energy production has intensified research into thermal energy storage (TES) to manage variability and improve system efficiency. Heat exchanger design is critical to achieving high power densities in TES systems. This study presents a high-surface-area phase change material (PCM)-to-air heat exchanger fabricated via resin-based stereolithography with a novel gyroid-based geometry tailored for enhanced performance. Material properties of the commercial PCM and resin were characterized using analytical techniques. A controlled air loop was used to evaluate heat transfer and pressure drop at various flow rates and inlet temperatures. Results show a strong dependence on the inlet temperature difference (ΔT) relative to the PCM melting point. During charging at the highest flow rate, increasing the inlet air temperature from ΔT = 5 °C to 20 °C above the melting point increased the average heat transfer rate by 187%. During discharging, decreasing the inlet temperature by the same ΔT below the melting point led to a 232% increase. Notably, the high-surface-area design enabled nearly symmetric charging and discharging behavior, a novel result for PCM-based TES systems which are often restricted by natural convection and other effects. The overall heat transfer coefficient was calculated and compared to values from standard design correlations. The maximum thermal effectiveness reached 95% at ΔT = 20 °C and a moderate flow rate of 34 m 3 /h. Peak coefficients of performance (COP) of 7 during charging and 6.4 during discharging were observed at ΔT = 20 °C and a low flow rate of 20 m 3 /h. These results demonstrate the viability of additively manufactured geometries for advanced TES applications.

25 ENERGY STORAGE↗

Aqueous Bromide Discharges from U.S. Coal-Fired Power Plants: Points of Origin, Concentration Ranges, and Effluent Treatment Costs

Bromide discharges from coal-fired power plants have received increased attention from regulatory bodies due to their contribution to the formation of disinfection byproducts (DBPs) in downstream drinking water treatment plants. Here, this paper characterizes the relative contributions of bromide from coal feedstocks and bromine-based mercury control processes, estimates the distribution of bromide concentrations at 85 active coal-fired power plants across the United States (U.S.) with wet flue gas desulfurization units, and estimates the cost of bromide removal from wastewater discharge using year 2020 data. Bromide discharges are estimated at the plant level using a combination of the reported coal rank and composition combusted, estimates of bromide addition in mercury control techniques under multiple halogen addition scenarios, and the estimated flue gas desulfurization (FGD) wastewater flow rate. The median, simulated plant-level estimation of total FGD wastewater flow is 18.3 gallons/min at a bromide concentration of 319 mg/L, equivalent to ~11.6 tonnes/year of bromide discharges to the environment. Next, we evaluated the expected cost of employing the best available technology (BAT) to control bromide discharges in FGD wastewater to prevent contributions to DBP formation. Treatment would need to remove more than 99.8% of bromide to reach the 0.2 mg/L voluntary incentive program (VIP) limit. The total cost of treatment depends on whether disposal is on- or off-site; the average costs for all plants combined come to an average of $110 million ($95.2/kgal) in 2021 U.S. dollars for on-site disposal, or $134 million ($115/kgal) for off-site disposal.

01 COAL, LIGNITE, AND PEAT↗

Using high-fidelity computational fluid dynamics to help design a wind turbine wake measurement experiment

Here, we describe the process of using large-eddy simulations of wind turbine wake flow to help design a wake measurement campaign. The main goal of the experiment is to measure wakes and wake deflection that result from intentional yaw misalignment under a variety of atmospheric conditions at the Scaled Wind Farm Technology facility operated by Sandia National Laboratories in Lubbock, Texas. Prior simulation studies have shown that wake deflection may be used for wind-plant control that maximizes plant power output. In this study, simulations are performed to characterize wake deflection and general behavior before the experiment is performed to ensure better upfront planning. Beyond characterizing the expected wake behavior, we also use the large-eddy simulation to test a virtual version of the lidar we plan to use to measure the wake and better understand our lidar scan strategy options. This work is an excellent example of a 'simulation-in-the-loop' measurement campaign.

17 WIND ENERGY↗

Evaluation of bio-inspired flow fields in a mediated Li-S flow battery for grid energy storage

Lithium-sulfur is a redox flow battery with high energy density for applications in safe, reliable, and lasting scaling of energy. However, lithium-based batteries often encounter platting as a problem thanks to poor Li-ions deposition after cycling. Aiming to reduce this impact, a uniform and continuous flow of ions is needed. On this work, novel bio-inspired flow fields in the electrochemical cell were tested to improve ions flowability and lithium platting control, ultimately enhancing battery performance and life. To secure Li-S efficient, low-cost, and secure energy storage capabilities, we chose a configuration with decamethylferrocene and cobaltocene acting as redox mediators, Li metal as anode and sulfur kept in a separate catholyte reservoir. Flow test and battery results insinuated a beneficial influence of bio-inspired designs in flowing electrolyte uniformly with less pressure and pump power in comparison to other conventional designs used in the industry, with an encouraging ability to approach a cheap, safe, and reliable Li-S grid energy storage.

25 ENERGY STORAGE↗

ACHILLES: Heat Transfer in PWR Core During LOCA Reflood Phase

1. NAME AND TITLE OF DATA LIBRARY ACHILLES -Heat Transfer in PWR Core During LOCA Reflood Phase. 2. NAME AND TITLE OF DATA RETRIEVAL PROGRAMS N/A 3. CONTRIBUTOR AEA Technology, Winfrith Technology Centre, Dorchester DT2 8DH United Kingdom through the OECD Nuclear Energy Agency Data Bank, Issy-les-Moulineaux, France. 4. DESCRIPTION OF TEST FACILITY The most important features of the Achilles rig were the shroud vessel, which contained the test section, and the downcomer. These may be thought of as representing the core barrel and the annular downcomer in the reactor pressure vessel. The test section comprises a cluster of 69 rods in a square array within a circular shroud vessel. The rod diameter and pitch (9.5 mm and 12.6 mm) were typical of PWR dimensions. The internal diameter of the shroud vessel was 128 mm. Each rod was electrically heated over a length of 3.66 m, which is typical of the nuclear heated length in a PWR fuel rod, and each contained 6 internal thermocouples. These were arranged in one of 8 groupings which concentrated the thermocouples in different axial zones. The spacer grids were at prototypic PWR locations. Each grid had two thermocouples attached to its trailing edge at radial locations. The axial power profile along the rods was an 11 step approximation to a "chopped cosine". The shroud vessel had 5 heating zones whose power could be independently controlled. 5. DESCRIPTION OF TESTS The Achilles experiments investigated the heat transfer in the core of a Pressurized Water Reactor during the re-flood phase of a postulated large break loss of coolant accident. The results provided data to validate codes and to improve modeling. Different types of experiments were carried out which included single phase cooling, re-flood under low flow conditions, level swell and re-flood under high flow conditions. Three series of experiments were performed. The first and the third used the same test section but the second used another test section, similar in all respects except that it contained a partial blockage formed by attaching sleeves (or "balloons") to some of the rods. 6. SOURCE AND SCOPE OF DATA Phenomena Tested - Heat transfer in the core of a PWR during a re-flood phase of postulated large break LOCA. Test Designation - Achilles Rig. The programme includes the following types of experiments: - on an unballooned cluster: -- single phase air flow -- low pressure level swell -- low flooding rate re-flood -- high flooding rate re-flood - on a ballooned cluster containing 80% blockage formed by 16 balloon sleeves -- single phase air flow -- low flooding rate re-flood 7. DISCUSSION OF THE DATA RETRIEVAL PROGRAM N/A 8. DATA FORMAT AND COMPUTER Many Computers (M00019MNYCP00). 9. TYPICAL RUNNING TIME N/A 11. CONTENTS OF LIBRARY The ACHILLES package contains test data and associated data processing software as well as the documentation listed above. 12. DATE OF ABSTRACT November 2013. KEYWORDS: DATABASES, BENCHMARKS, HEAT TRANSFER, LOSS-OF-COLLANT ACCIDENT, PWR REACTORS, REFLOODING

Source record↗

The Flow Visualization for the Separation of Air-water Bubbly Two-phase Flow Through a Vertical T-junction

T-junction is a typical structure in many industrial systems such as power plants, chemical process, and hydrocarbon production industries. The separation of two-phase flow passing through T-junction is a common flow phenomenon. There are lots of investigations regarding two-phase flow separation in branching tees and wyes tees. The characteristic of the two-phase flow between the two outlets are always non-uniform, and this kind of fluid status may contribute to the unpredictable damage of downstream facilities. For the nuclear power plants, severe accidents analysis is important especially for Light-Water Reactors (LWR) when Loss of Coolant Accident (LOCA) occurs. The small break of the pipe may cause the coolant become two-phase flow due to the pressure drop. Under certain conditions, the behavior of T-junction is similar to a gas-liquid separator, as a result of the gas enters the side arm and the liquid flows straight along the run arm. The partial separation of gas-liquid mixtures can reduce the load on the main separator, probably leading to smaller units. The study aims to establish complete visual observations for the benchmark of Computational Fluid Dynamics (CFD) model. As a consequence, a vertical T-junction (D = 26 mm) experimental loop was set up for the purpose of elaborating the complex two-phase fluid phenomena. In this experiment, variables were manipulated under highly controlled conditions and a photographic method was proposed to analyze the images of phase separation. Furthermore, the images obtained by camera have been discussed to receive valuable information about the two phase flow behavior around the T-junction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Land subsidence in the Cerro Prieto Geothermal Field, 1 Baja California, Mexico, from 1994 to 2005. An integrated analysis of DInSAR, levelingand geological data.

Cerro Prieto is the oldest and largest Mexican geothermal field in operation and has been producing electricity since 1973. The large amount of geothermal fluids extracted to supply steam to the power plants has resulted in considerable deformation in and around the field. The deformation includes land subsidence and related ground fissuring and faulting. These phenomena have produced severe damages to infrastructure such as roads, irrigation canals and other facilities. In this paper, the technique of Differential Synthetic Aperture Radar Interferometry (DInSAR) is applied using C-band ENVISAR ASAR data acquired between 2003 and 2006 to determine the extent and amount of land subsidence in the Mexicali Valley near Cerro Prieto Geothermal Field. The DInSAR results were compared with published data from precise leveling surveys (1994- 1997 and 1997-2006) and detailed geological information in order to improve the understanding of temporal and spatial distributions of anthropogenic subsidence in the Mexicali Valley. The leveling and DInSAR data were modeled to characterize the observed deformation in terms of fluid extraction. The results confirm that the tectonic faults control the spatial extent of the observed subsidence. These faults likely act as groundwater flow barriers for aquifers and reservoirs. The shape of the subsiding area coincides with the Cerro Prieto pull-apart basin. In addition, the spatial pattern of the subsidence as well as changes in rate are highly correlated with the development of the Cerro Prieto Geothermal Field.

58 GEOSCIENCES↗

CHP Integrated with Burners for Packaged Boilers (Final Report)

The objective of this project was to engineer, design, fabricate, and field demonstrate a Boiler Burner Energy System Technology (BBEST) that integrates a low-cost, clean burning, gas-fired simple-cycle (unrecuperated) 100 kWe (net) microturbine (SCMT) with a new ultra low-NOx gas-fired burner (ULNB) into one compact Combined Heat and Power (CHP) product that can be retrofit on new and existing industrial and commercial boilers in place of conventional burners. The Scope of Work for this project was segmented into two principal phases: (Phase I) Hardware development, assembly and pre-test and (Phase II) Field installation and demonstration testing. Phase I was divided into five technical tasks (Task 2 to 6). These tasks covered the engineering, design, fabrication, testing and optimization of each key component of the CHP system principally, ULNB, SCMT, assembly BBEST CHP package, and integrated controls. Phase I work culminated with the laboratory testing of the completed BBEST assembly prior to shipment for field installation and demonstration. Phase II consisted of two remaining technical tasks (Task 7 and 8), which focused on the installation, startup, and field verification tests at a pre-selected industrial plant to document performance and attainment of all project objectives. Technical direction and administration was under the management of CMCE, Inc. Altex Technologies Corporation lead the design, assembly and testing of the system. Field demonstration was supported by Leva Energy, the commercialization firm founded by executives at CMCE and Altex. Leva Energy has applied for patent protection on the BBEST process under the trade name of Power Burner and holds the license for the burner currently used in the product. The commercial term Power Burner is used throughout this report to refer to the BBEST technology proposed for this project. The project was co-funded by the California Energy Commission and the Southern California Gas Company (SCG), a division of Sempra Energy. These match funds were provided via concurrent contracts and investments available via CMCE, Altex, and Leva Energy The project attained all its objectives and is considered a success. CMCE secured the support of GI&E from Italy to supply 100 kW Turbec T-100 microturbines for the project. One was purchased by the project’s subcontractor, Altex, and a second spare was purchased by CMCE under this project. The microturbines were then modified to convert from their original recuperated design to a simple cycle configuration. Replacement low-NOx silo combustors were designed and bench tested in order to achieve compliance with the California Air Resources Board (CARB) 2007 emission limits for NOx and CO when in CHP operation. The converted microturbine was then mated with a low NOx burner provided by Altex via an integration section that allowed flow control and heat recovery to minimize combustion blower requirements; manage burner turndown; and recover waste heat. A new fully integrated control system was designed and developed that allowed one-touch system operation in all three available modes of operation: (1) CHP with both microturbine and burner firing for boiler heat input greater than 2 MMBtu/hr; (2) burner head only (BHO) when the microturbine is under service; and (3) microturbine only when boiler heat input requirements fall below 2 MMBtu/hr. This capability resulted in a burner turndown performance of nearly 10/1, a key advantage for this technology over conventional low NOx burners. Key components were then assembled into a cabinet with additional support systems for generator cooling and fuel supply. System checkout and performance tests were performed in the laboratory. The assembled system and its support equipment were then shipped and installed at a host facility where final performance tests were conducted following efforts to secure fabrication, air, and operating permits. The installed power burner is now in commercial operation and has achieved all the performance goals.

20 FOSSIL-FUELED POWER PLANTS↗

K-1435 Wastewater Treatment System for the Toxic Substances Control Act Incinerator Wastewater at the East Tennessee Technology Park, Oak Ridge, TN

This paper discusses the design and performance of a wastewater treatment system installed to support the operation of a hazardous waste incinerator. The Oak Ridge Toxic Substances Control Act Incinerator (TSCAI), located at the East Tennessee Technology Park (ETTP), is designed and permitted to treat Resource ConservatioN and Recovery Act (RCRA) wastes including characteristic and listed wastes and polychlorinated biphenyl (PCB)-contaminated mixed waste. the incinerator process generates acidic gases and particulates which consist of salts, metals, and radionuclides. These off-gases from the incinerator are treated with a wet off-gas scrubber system. The recirculated water is continuously purged (below down), resulting in a wastewater to be treated. Additional water sources are also collected on the site for treatment, including storm water that infiltrates into diked areas and fire water from the incinerator's suppression system. To meet regulatory requirements for discharge, a wastewater treatment system (WWTS) was designed, constructed, and operated to treat these water sources. The WWTS was designed to provide for periodic fluctuation of contaminant concentrations due to various feed streams to the incinverator. Blow down consists of total suspended solids (TSS) and total dissolved solids (TDS), encompassing metals, radionuclide contamination and trace organics. The system design flow rate range is 35 to 75 gallons per minute (gpm). The system is designed with redundancy to minimize time off-line and to reduce impacts to the TSCAI operations. A novel treatment system uses several unit operations, including chemical feed systems, two-stage chemical reaction treatment, microfiltration, sludge storage and dewatering, neutralization, granular activated carbon, effluent neutralization, and a complete programmable logic controller (PLC) and human-machine interface (HMI) control system. To meet the space requirements and to provide portability of the WWTS to other applications, the system was installed in three, over-the-road semi trailers, and interconnected with piping and power. Trailers were oriented on a small site footprint to facilitate ease of installation. A remote sump pump skid was provided to convey water from two holding sumps adjacent to the treatment process. An accumulation tank and pump were also provided to receive miscellaneous wastewaters for treatment if they meet the waste acceptance criteria. The paper includes details of the technology used in the design, the requirements for compliance, and the initial performance demonstration and jar testing results. The WWTS successfully allowed for highly efficient, high-volume treatment with compliant discharge to off-site surface water.