Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Development of Advanced Lightweight Polymeric Foam Thermal Protection for Space Launch Vehicles

Lightweight thermal protective materials are essential for temperature regulation during ascent of space launch vehicles, especially for expendable launch vehicles and cryogenic propellant tanks. Among the lightest thermal protective materials commonly in use is polymeric foam, in the form of pour foam or spray-on foam insulation (SOFI). Foam processing is rapid, can accommodate large-scale or small-scale challenging geometries easily, and can be used in a climate controlled or non-climate-controlled setting. Application systems can be fixed or portable. Use-temperatures of foam range from cryogenic to those that will ablate the material.

TPS↗

Modernization of Insulative Reusable Thermal Protection Systems (IRTPS)

Insulative thermal protection systems, such as Flexible Reusable Surface Insulation blankets and High Temperature Reusable Surface Insulation tiles, were developed for the Shuttle Orbiter to enable reuse of the vehicle for low-earth orbit missions. Since reusability is essential to many new industry launch and space vehicles, Shuttle-derived thermal protection materials (TPMs) are being sought for their flight proven performance. Alumina Enhanced Thermal Barrier (AETB) is the state-of-the-art tile material that was developed in the 90’s. AETB along with associated coatings, reaction cured glass (RCG) and Toughened Unipiece Fibrous Insulation (TUFI), are currently made by NASA using heritage raw materials derived from lifetime purchases. Finding viable replacements for raw materials that have changed in nature or are obsolete is important for continuation of these TPMs. In some cases, the use of modern raw materials has been shown to yield tile with reduced performance, most notably in mechanical properties. ​ In this work, the production of AETB will be discussed to better understand the process-structure-property relationships and for allowing use of these modern alternatives. A small-scale tile casting system was developed for rapid and efficient exploration of the manufacturing variables such raw material selection and pre-processing, casting process parameters, and billet firing protocols. An optical transmission defect characterization technique was implemented to correlate process variables to structure. Comparisons between TUFI/RCG coated AETB derived from heritage and modern raw materials will be shown including AHF arc jet test results completed under a collaboration with Stratolaunch.

thermal protection materials↗

A Physical Protection Systems Test Bed for International Counter-Trafficking System Development

Physical protection systems have a widespread impact on the nuclear industry in areas such as nuclear safeguards, arms control, and trafficking of illicit goods (e.g., nuclear materials) across international borders around the world. Many challenges must be overcome in design and deployment of foreign border security systems such as lack of infrastructure, extreme environmental conditions, limited knowledge of terrain, insider threats, and occasional cultural resistance. Successful security systems, whether it be a system designed to secure a single facility or a whole border security system, rely on the entire integrated system composed of multiple subsystems. This test bed is composed of many unique sensors and subsystems, including wireless unattended ground sensors, a buried fiber-optic acoustic sensor, a lossy coaxial distributed sensor, wireless links, pan-tilt-zoom cameras, mobile power generation systems, unmanned aerial vehicles, and fiber-optic-fence intrusion detection systems. A Common Operating Picture software architecture is utilized to integrate a number of these subsystems. We are currently performance testing each system for border security and perimeter security applications by examining metrics such as probability of sense and a qualitative understanding of the sensor s vulnerability of defeat. The testing process includes different soil conditions for buried sensors (e.g., dry, wet, and frozen) and an array of different tests including walking, running, stealth detection, and vehicle detection. Also, long term sustainability of systems is tested including performance differences due to seasonal variations (e.g. summer versus winter, while raining, in foggy conditions). The capabilities of the test bed are discussed. Performance testing results, both at the individual component level and integrated into a larger system for a specific deployment (in situ), help illustrate the usefulness and need for integrated testing facilities to carry out this mission. The test bed provides access to grassy fields, wooded areas, and a large waterway three distinct testing environments. The infrastructure supporting deployment of systems at the test bed includes grid power, renewable power systems, climate controlled enclosures, high bandwidth wireless links, and a fiber optic communications backbone. With over 10 acres of dedicated area and direct waterway access, the test bed is well suited for long term test and evaluation of physical protection and security systems targeting a wide range of applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operational Radiation Protection in High-Energy Physics Accelerators

An overview of operational radiation protection (RP) policies and practices at high-energy electron and proton accelerators used for physics research is presented. The different radiation fields and hazards typical of these facilities are described, as well as access control and radiation control systems. The implementation of an operational RP programme is illustrated, covering area and personnel classification and monitoring, radiation surveys, radiological environmental protection, management of induced radioactivity, radiological work planning and control, management of radioactive materials and wastes, facility dismantling and decommissioning, instrumentation and training.

43 PARTICLE ACCELERATORS↗

Game theoretic analysis of physical protection system design

The physical protection system (PPS) of a fictional small modular reactor (SMR) facility have been modeled as a platform for a game theoretic approach to security decision analysis. To demonstrate the game theoretic approach, a rational adversary with complete knowledge of the facility has been modeled attempting a sabotage attack. The adversary adjusts his decisions in response to investments made by the defender to enhance the security measures. This can lead to a conservative physical protection system design. Since defender upgrades were limited by a budget, cost benefit analysis may be conducted upon security upgrades. One approach to cost benefit analysis is the efficient frontier, which depicts the reduction in expected consequence per incremental increase in the security budget.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The safety improvement of Romanian radioactive waste facilities as an example for human and environmental protection

According to IAEA classification, Romania with two nuclear research centres, with 2 Nuclear Power Units in operation at Cernavoda Town and with 2 new Units envisaged to be in operation soon, can be considered as a country with an average nuclear activity. In Romania there was an extensive interest in management of radioactive wastes generated by the use of nuclear technology in industry and research. Using the most advanced technologies in the mentioned time periods, Romania successfully accomplished to solve all management issues related to radioactive wastes being addressed all safety concerns. Every step of nuclear activity development was accompanied by the suitable waste management facilities. So that, in order to improve the existing treatment and disposal capacities for institutional waste, the existing Radioactive Waste Treatment Facility (STDR) and the National Repository Radioactive Wastes (DNDR) at Baita, Bihor, will be improved to actual requirements on the occasion of VVR-S Research Reactor decommissioning. This activity is in development into the frame of a National funded project related to disposal galleries filling improvement and repository closure for DNDR Baita, Bihor. All improvements will be approved by Environmental Protection Authority and Regulatory Body, being a guaranty of human and environmental protection. Also, in accordance with national specific and international policies and taking into account decommissioning activities related to the present operating NPPs, all necessary measures were considered in order to avoid unnecessary generation of radioactive wastes, to minimize, as much as possible, waste production and accumulation and the necessity to develop optimum solutions for a new repository with the assurance of improved nuclear safety. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Retrospective Assessment of Correlation between Occupational and Public Radiation Protection Programs Performance Metrics at a FUSRAP Site - 17546

A retrospective assessment of the occupational and environmental radiation protection programs includes the consideration of performance metrics at the qualitative and quantitative level. When key radiation protection (RP) program metrics are tracked over the course of several years, correlations may present themselves. Strong correlations between variables may be considered when establishing or validating baseline RP Program elements (i.e., controls, monitoring regimes, and additional ALARA measures) for the safe excavation and handling of naturally occurring radioactive materials comingled in soil-like wastes at FUSRAP sites. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Port Hope Area Initiative - Port Granby Project: Effectiveness of the Radiation Protection Program - 18595

The Port Granby Project is large remediation project currently underway. It is approximately 50% complete. A comprehensive and effective radiation protection program has been developed and implemented for the Port Granby Project. The potential radiation hazards associated with this project include: external (gamma) radiation, radon, inhalation, contamination and ingestion. The radiation protection program is highly effective and has succeeded in managing the significant radiation hazards associated with this remediation project. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Protection factors for French dwellings - 25573

IRSN's current method of assessment of public exposure from atmospheric releases of radioactivity from nuclear installations assumes an exposed person outside of any building; even though the majority of time is spent inside. A more realistic assessment would take into account the protection from atmospheric contamination and deposits provided by dwellings. Therefore, IRSN carried out a study to estimate protection factors for gamma ray emitting radionuclides. This was done with the MCNP calculation code and assumed several French dwelling types. Air contamination (outside and inside) and deposits on soil (outside and inside) and on a roof are considered. Method and results are set out for a few radionuclides. The results show the influence of dwelling type, and also of room sealing (considering inner contamination or not) in case of radiological emergency. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Protection for the First Korea Heavy-ion Medical Accelerator (KHIMA) Facility - Paper 7

The number of particle therapy facilities is increasing worldwide due to the encouraging results obtained at research facilities such as the Lawrence Berkeley National Laboratory (USA), the Helmholtz Center for Heavy Ion Research GSI (Germany), and the Heavy Ion Medical Accelerator (HIMAC) in Chiba (Japan). The first hospital-based heavy-ion therapy facility is under construction in Busan, Korea, at the Korea Institute of Radiological and Medical Sciences [KIRAMS]. The project was originally designed to develop a compact superconducting cyclotron for hadron therapy able to deliver forefront beams of heavier ions, essentially carbon ions of energy, 430 MeV/u. Radiation protection issues play an important role in every stage of the project such as civil construction planning, control system design, and special technological plants. Monte Carlo transport codes are the best tools to solve these issues and the FLUKA2011 and MCNPX2.7.0 codes are used in this work. Beam loss distributions of cyclotron installations in combination with passive or active beam shaping methods have a particularly high implication on the protection layout of the facility. Methods for shielding and activation calculations are described with an emphasis on carbon ion beams. All the tools and databases require verification. Benchmarking is an instrumental process for verification. An overview of benchmarking efforts will also be given and the need for further benchmarks is discussed. (authors)

43 PARTICLE ACCELERATORS↗

High Current-Density-Charging Lithium Metal Batteries Enabled by Double-Layer Protected Lithium Metal Anode

The practical application of lithium (Li) metal anode (LMA) is still hindered by non-uniformity of solid electrolyte interphase (SEI), formation of "dead" Li, and continuous consumption of electrolyte although LMA has an ultrahigh theoretical specific capacity and a very low electrochemical redox potential. Herein, we report a facile protection strategy for LMA using a double layer (DL) coating that consists of a polyethylene oxide (PEO)-based bottom layer which is highly stable with LMA and promotes uniform ion flux, and a cross-linked polymer-based top layer which prevents solvation of PEO layer in electrolytes. Li deposited on DL-coated Li (DL@Li) exhibits a smoother surface and much larger size than that deposited on bare Li. The LiF/Li 2 O enriched SEI layer generated by the salt decomposition on top of DL@Li further suppresses the side reactions between Li and electrolyte. Driven by the abovementioned advantageous features, the DL@Li||LiNi 0.6 Mn 0.2 Co 0.2 O 2 cells demonstrate capacity retention of 92.4% after 220 cycles at a current density of 2.1 mA cm -2 (C/2 rate) and stability at a high charging current density of 6.9 mA cm -2 (1.5C rate). These results indicate that the DL protection is promising to overcome the rate limitation of LMAs and high energy-density Li metal batteries.

25 ENERGY STORAGE↗

Indicator W{sub so}: A New Parameter for Characterization of Protective Coating Efficiency Against Humidity

This paper concerns the development of W{sub so,} an indicator of the efficient protection against humidity, as a new parameter characterizing protective coatings. This indicator determines to what degree the covering of cores and sand molds influences, advantageously or disadvantageously, the humidity absorption from surroundings into surface layers, in comparison with layers without covering, which absorb the moisture at high-humidity conditions of atmospheric air. Simultaneously, this indicator will allow for an efficient comparison of tendencies of individual coatings for moisture sorption depending on the number of their layers. Thus, it can serve as a guideline in selecting the coating type for the molding sand on which it will be deposited, while taking into account the time of waiting—of molds and cores covered with coatings—on pouring with liquid metal and the atmospheric conditions to which they will be exposed.

36 MATERIALS SCIENCE↗

Influence of Temperature Variation on the Formation and Corrosion Protective Performance of Calcium Carbonate Deposits in Artificial Seawater

The aim of this research was to investigate the influence of temperature variation on the formation and protective behavior of calcium carbonate scale deposited on steel electrodes in artificial seawater. Chronoamperometry measurement, electrochemical impedance spectroscopy (EIS), scanning electron microscope (SEM) and x-ray diffraction (XRD) were employed for analysis. An increase in temperature from 20 to 50 °C accelerated the oxygen reduction reaction, which increased the nucleation/deposition rate. The chronoamperometry, SEM and XRD results indicated that complete coverage of the electrode surface was achieved at higher temperatures because a denser layer of scale deposits covered the entire surface of the metal and acted as a barrier against the passage of oxygen. The EIS results showed that better corrosion protection was obtained after deposition that included a stepwise decrease in temperature, indicating fewer pathways through the deposited layer onto the electrode surface.

36 MATERIALS SCIENCE↗

Few-Layers Graphene Film and Copper Surface Morphology for Improved Corrosion Protection of Copper

Graphene has shown excellent corrosion protection of copper (Cu). The corrosion protection of Cu is governed by the characteristics of the deposited graphene and Cu surface morphology underneath. In this work, graphene films (1-2, 4-5 layers) were deposited on Cu using a chemical vapor deposition by changing hydrogen (H{sub 2}) concentration during the annealing stage. The chemical structure and surface microstructural features of graphene/Cu were inspected by Raman spectroscopy, scanning electron microscopy, transmission electron microscopy, and atomic force microscopy. The electrochemical corrosion performance of graphene/Cu was studied in 0.5 M sodium chloride solution using potentiodynamic polarization and electrochemical impedance spectroscopic measurements. The 1-2 layers of graphene and rough Cu surface were obtained for low H{sub 2} concentrations (0 and 2.5%), whereas high H{sub 2} concentrations, 20 and 50%, resulted in a smooth Cu surface and 4-5 layers of graphene. Our results showed that Cu with a smooth surface and multilayer graphene film exhibited the best corrosion resistance against electrochemical degradation. Tafel analysis revealed that Cu with 4-5 layers of graphene coating corroded nearly three orders of magnitude slower than the annealed Cu, without graphene coating. The results of this study can be useful for several applications where Cu is in close contact with salt species.

36 MATERIALS SCIENCE↗

Polyaniline-based all-polymeric adhesive layer: An effective lightning strike protection technology for high residual mechanical strength of CFRPs

Carbon fiber reinforced plastics (CFRPs) are vulnerable to lightning strikes due to their low electrical conductivity and low heat resistance. A lightning strike can damage CFRP structure catastrophically. Most common lightning strike protection (LSP) technology, consists of expanded metal foils/films on top of composite structures. This technology possesses disadvantages such as increased weight, galvanic corrosion, expensive integration and repair costs. In the present study, authors introduce a novel, easy to apply and all-polymeric LSP material. A doped intrinsic conductive polymer i.e. Polyaniline (PANI) dispersed in a thermosetting cross-linking polymer divinylbenzene (DVB) has been used to prepare an adhesive layer of 0.25–0.4 mm thickness. CFRP structure coated with PANI-based LSP layer, when tested against simulated lightning impulse current of 100 kA, demonstrated effective dissipation of the current, rendering almost 100% safety to the CFRP structure. PANI showed the capability to create a 3-D conductive network due to its self-assembling property, which makes it superior compared to its counterpart carbon/metal nano-filler based LSP technologies. Almost 100% residual strength of PANI-LSP protected CFRPs is reported in this work.

42 ENGINEERING↗

Thickness threshold study of polyaniline-based lightning strike protection coating for carbon/glass fiber reinforced polymer composites

Different polyaniline (PANI) based lightning strike protection (LSP) coating thicknesses were tested against simulated lightning strike tests to evaluate the threshold thickness of the coating. A series of lightning strike tests were performed on carbon/glass fiber reinforced polymer (CFRP/GFRP) composites subjected to simulated lightning currents ranging from 40 to 100 kA. Five LSP-coated specimens were considered herein: two CFRP and three GFRP composites. A minimum of ~ 345 μm thick PANI-based LSP coating on CFRP and GFRP composites under a 40 kA peak current retained 83 % and 100 % residual strength, respectively. Additionally, GFRP specimens tested against 60 and 100 kA peak currents exhibited 100 % residual strength. Finally, this study proposes that a PANI-based LSP coating is suitable for protecting GFRP composites, while the careful design is necessary for CFRP composites to avoid any catastrophic failure.

36 MATERIALS SCIENCE↗

Environmental assessment in The Netherlands: Effectively governing environmental protection? A discourse analysis

Environmental assessment (EA) aims to enhance environmental awareness and to ensure that environmental values are fully considered in decision-making. In the EA arena, different discourses exist on what EA should aim for and how it functions. We hypothesise that these discourses influence its application in practice as well as its effectiveness in terms of achieving the above goals. For instance, actors who consider EA as a hindrance to fast implementation of their projects will probably apply it as a mandatory checklist, whereas actors who believe that EA can help to develop more environmentally sound decisions will use EIA as a tool to design their initiatives. In this paper we explore discourses on EA in The Netherlands and elaborate on their implications for EA effectiveness. Based on an innovative research design comprising an online survey with 443 respondents and 20 supplementary semi-structured interviews we conclude that the dominant discourse is that EA is mainly a legal requirement; EAs are conducted because they have to be conducted, not because actors choose to do so. EA effectiveness however seems reasonably high, as a majority of respondents perceive that it enhances environmental awareness and contributes to environmental protection. However, the 'legal requirement' discourse also results in decision-makers seldom going beyond what is prescribed by EA and environmental law. Despite its mandatory character, the predominant attitude towards EA is quite positive. For most respondents, EA is instrumental in providing transparency of decision-making and in minimising the legal risks of not complying with environmental laws. Differences in discourses seldom reflect extreme opposites. The 'common ground' regarding EA provides a good basis for working with EA in terms of meeting legal requirements but at the same time does not stimulate creativity in decision-making or optimisation of environmental values. In countries characterised by less consensual political cultures we may expect more extreme discourses on EA, the consequences of which are reflected upon in this paper. - Highlights: Black-Right-Pointing-Pointer The effectiveness of environmental assessment (EA) depends in part on meanings associated with EA (i.e., discourse). Black-Right-Pointing-Pointer Our results suggest that the general discourse in The Netherlands is that EA is a legal requirement, nothing more. Black-Right-Pointing-Pointer This discourse makes EA effective in protecting the environment, but not in the optimisation of environmental values. Black-Right-Pointing-Pointer EA has a limited contribution to the development of policy alternatives or innovative solutions to environmental problems. Black-Right-Pointing-Pointer There is a high consensus among EA professionals, providing a common ground for working with EA.

54 ENVIRONMENTAL SCIENCES↗

Stakeholder perceptions of Environmental Management Plans as an environmental protection tool for major developments in the UK

Insufficient implementation and the lack of legislative requirements for follow-up measures following the approval of projects are consistently highlighted as major shortcomings of Environmental Impact Assessment (EIA). Although adopted over 15 years ago by the World Bank, Environmental Management Plans (EMPs) were only semi-formalised in the UK in 2008 and arguably provide a continuous link or ‘bridge’ between the EIA process pre-consent and an Environmental Management System (EMS) post-consent. Drawing on twenty-one semi-structured interviews with stakeholders and thematic analysis of their responses, and a broad-scale practitioner survey, this study aimed to assess the effectiveness of EMPs as an environmental protection tool across the project lifecycle for major developments. The findings revealed a mixed picture of EMP effectiveness in practice, with EMPs only partially fulfilling a bridging role between EIA and EMS. There is no ‘gold standard’ terminology for EMPs, all having slightly different uses, thus presenting different focuses to different stakeholders and further enhancing variation in practice. For many stakeholders, the effectiveness was simply not known, due to the lack of communication and follow-up that still exists. EMP–EMS linkages were shown to be effective from the developer's perspective when a single organisation has involvement across all project phases, though weaknesses occur when multiple parties are involved. Among other stakeholders, knowledge varied significantly; whilst some were in agreement that the linkages worked, many were unaware of the connections and thought of them as two quite separate tools. Stakeholders advocated for the need to make EMPs a legal requirement; for improved communication between stakeholders during EMP implementation and increased documentation of project outcomes; and for EMPs to be consistently written by environmental professionals. Furthermore, weak links in the current process may be improved by providing detailed guidance for organisations on the potential for EMP–EMS linkages, with the additional aim of encouraging stakeholders to broaden their current specialist knowledge on environmental protection tools. - Highlights: • We assessed the effectiveness of Environmental Management Plans (EMPs) for major developments, focusing on delivery of mitigation and monitoring. • EIA and Environmental Management Systems (EMS) post-consent are weakly linked. • The use of EMPs varies significantly in practise, partly due to the range of terminology used. • Linkages are hampered by poor communication and follow-up • More detailed guidance on how EMPs can successfully link with EMS is required.

54 ENVIRONMENTAL SCIENCES↗