Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pumped Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

ENERGY STAR Residential Water Heater Specification and Test Method for Connected Residential Water Heaters

Electric water heaters have long been used as a tool for demand response due to their inherent thermal storage and large electric load. Traditionally, electric water heaters have been controlled by external load control switches, but that type of control does not work well with more efficient heat pump water heaters and cannot ensure that consumers have adequate hot water. Water heater manufacturers are adding more sophisticated controls that allow utilities or consumers to control their water heaters in new ways that can provide demand response without impacting consumer comfort. Further, the electric utility grid has seen a rapid increase the availability of renewable energy, which, depending on the type of renewable energy, can provide large amounts of energy for a portion of the day, but reduced or no energy at other times. In response to these advances in controls, availability of periodic renewable energy, and in an effort to have a standard which can be applied at a national level, ENERGY STAR and the Department of Energy have developed a Product Specification and Test Method for Connected Residential Water Heaters. In this session, we will discuss the new specification and test method, as well as show some initial results from running the new test method with two different HPWHs at NREL.

connected water heater↗

Advanced low-cost intermetallic coatings for molten salt pump impeller. Final report

1.0 INTRODUCTION The use of solar energy to produce steam for the generation of electricity is an established technology, with multiple designs for concentrating solar power (CSP) steam generators available commercially and a number of such units currently operating. As part of the effort to improve the overall efficiency of this technology, designers have developed thermal energy storage (TES) mechanisms that employ molten salt to capture a portion of the solar energy available during the day-time hours and make that energy available for steam generation during periods when the sun’s energy is not available. In current TES systems, nitrate salts are used extensively as the medium of energy exchange. However, due to the chemical instability of these salts at temperatures above 600ºC, they are not being considered for use in the next more efficient generation of CSP plants, in which the energy exchange fluids will be required to operate in the range 600ºC to 800ºC. At these higher temperatures, molten chloride salts, such as KCl-MgCl2, are viewed as promising alternatives to the nitrate salts, but, of course, these chloride-based salts are highly corrosive to the engineering alloys commonly used in the construction of pressure vessels, heat exchangers, pumps and piping at high temperatures. Hence, a solution to the problem of material degradation is essential if the next generation of CSP plants is to be commercially viable (Ref 1). In order to effectively address the problem of molten chloride salt corrosion at high temperatures (≥ 750ºC) and thereby to reduce the cost of molten salt tanks and related apparatus, various options have been considered, with one of the most promising being an innovative coatings system developed and applied onto low alloy ferritic or austenitic stainless material. Development of such a coating system would reduce the capital costs of thermal energy storage (TES) and increase the overall efficiency of the concentrating solar power (CSP) system. Although high strength nickel base alloys are well suited for many high temperature applications, they have significant limitations when exposed to molten chloride salt conditions and they are very expensive. Monolithic materials such as the austenitic stainless steels (e.g., SS310 and SS347) and the more common nickel base alloys (e.g., IN625 and IN800H) have exhibited high corrosion rates in molten chloride salt environments (Ref1). Molten salt corrosion of IN625 in salts containing chlorides showed a catastrophic corrosion rate of 1.111”/year at 800ºC (Ref1). Hence, an innovative coatings solution to mitigate molten chloride salt corrosion is needed. Of the many coating techniques available in the market, no one technique appears to be capable of producing effective protection from molten salt corrosion at a relatively low cost. There are thermal spray coating techniques, in particular the twin wire-arc technology, that are attractive when considering the coating of large molten salt tanks because the coatings application rate is high, the overall application cost is low and repairs to the coating can readily be made either in the shop or in the field. However, the twin wire arc coating materials currently available in the market have certain inherent limitations, including porosity and mechanical bonding to the substrate, which limit their effectiveness in providing protection against molten chloride salt corrosion at high temperatures. What is required is an approach that combines the economy and versatility of thermal spray wire-arc technology with the superior resistance of advanced alloys to effectively combat molten chloride salt corrosion at elevated temperatures. Applied Thermal Coatings, Inc. (ATC) has investigated an innovative coatings technology to produce dual layer cermet/ceramic coatings that will be dense and impervious to any corrosive molten salts/fluids, thereby resisting the effects of molten salt corrosion. Development of coatings using this technology will make it possible to fabricate the molten salt systems using a relatively low-cost base material, which will reduce the overall cost of the power generating system and enhance the commercial viability of solar power. 2.0 PROJECT OVERVIEW Of the coating technologies available for the production of a cost-effective method of protection from the effects of high-temperature chloride attack, there are two that offer specific advantages for the CSP/TES application, particularly when used in a way that effectively complements the strengths of each coating method. The first of these is electroless nickel plating, through which a nickel-rich layer is produced on the surface of a component through chemical reduction. The second coating technology is aluminizing, in which aluminum is diffused into the surface of a component and, depending on the composition of the substrate, aluminides are formed. The objective of this project has been to demonstrate the feasibility of a low- cost coating for the protection of pump impellers used for the inductive transport of molten salts. Initial interest focused on an inter-metallic nickel aluminide coating and subsequently, for economic reasons, consideration also was given to a coating composed of iron aluminides. Applying such coatings to low alloy or austenitic stainless-steel substrates will provide the superior resistance to molten chloride salt corrosion and blade tip erosion that normally can be achieved only through the use of more highly alloyed – and, therefore, more expensive - nickel-base materials and it will do so at a substantially lower cost. The coating systems evaluated were designed to take advantage either of the combined strengths of the electroless nickel plating process and the aluminizing process to produce a nickel-aluminide intermetallic coating or to rely solely on the aluminizing process to produce, in conjunction with iron from the substrate, a protective layer consisting of iron aluminides. With respect to the nickel aluminide protection, this has been achieved by first depositing a layer of nickel-rich alloy onto an austenitic stainless substrate using the electroless nickel plating process and then aluminizing the nickel- coated surface to produce the nickel aluminide coating. With respect to the iron aluminide protection, this has been achieved by aluminizing bare austenitic stainless steel. Testing has supported the conclusion that the developed coatings will resist attack by molten chloride salts at high temperatures (550°C to 750°C) and have sufficient hardness to resist blade tip erosion.The steps taken to develop either a low-cost intermetallic nickel aluminide coating using electroless nickel plating and aluminizing or a low-cost iron aluminide coating using aluminizing only, and to demonstrate the quality of the coatings and their effectiveness against molten chloride salt corrosion and erosion at high temperatures (≤ 750ºC) have been as follows: 1. Design of the optimum electroless nickel plating and aluminizing mixtures using advanced thermodynamic analysis; 2. Development of processing parameters for the electroless nickel plating and aluminizing processes, to be used either together or separately; 3. Production of specimens coated using the designated electroless nickel plating process; 4. Production of samples with intermetallic nickel aluminide coating or iron aluminide coating; 5. Investigation of the performance of the intermetallic nickel aluminide coating and the iron aluminide coating when subjected to molten chloride salts corrosion at high temperatures (≥ 750ºC); and, 6. Metallurgical characterization of the microstructure of the coatings, both prior to and after exposure to molten salt environments at elevated temperatures.

14 SOLAR ENERGY↗

Geological Thermal Energy Storage Using Solar Thermal and Carnot Batteries: Techno-Economic Analysis: Preprint

Energy storage is increasingly necessary as Variable Renewable Energy (VRE) technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological Thermal energy storage (GeoTES) is proposed as a solution for long-term energy storage. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. In this article, we describe a techno-economic model that has been developed to evaluate GeoTES systems. The models are developed by combining the output of specialist models which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models are developed so that the performance can be evaluated at each hour of the year. GeoTES can be charged with two different energy sources: (1) concentrating solar thermal and (2) renewable electricity using heat pumps (henceforth known as a "Carnot Battery"). The stored thermal energy can be used to generate electricity and - uniquely - also directly produce heat that can be used by industrial processes. Furthermore, Carnot-Battery-GeoTES can also be used to form a cold storage reservoir. Preliminary results that quantify the technical and economic performance of these two GeoTES systems are presented.

carnot battery↗

SAVANNAH RIVER SITE INCIPIENT SLUDGE MIXING IN RADIOACTIVE LIQUID WASTE STORAGE TANKS DURING SALT SOLUTION BLENDING

This paper is the second in a series of four publications to document ongoing pilot scale testing and computational fluid dynamics (CFD) modeling of mixing processes in 85 foot diameter, 1.3 million gallon, radioactive liquid waste, storage tanks at Savannah River Site (SRS). Homogeneous blending of salt solutions is required in waste tanks. Settled solids (i.e., sludge) are required to remain undisturbed on the bottom of waste tanks during blending. Suspension of sludge during blending may potentially release radiolytically generated hydrogen trapped in the sludge, which is a safety concern. The first paper (Leishear, et. al. [1]) presented pilot scale blending experiments of miscible fluids to provide initial design requirements for a full scale blending pump. Scaling techniques for an 8 foot diameter pilot scale tank were also justified in that work. This second paper describes the overall reasons to perform tests, and documents pilot scale experiments performed to investigate disturbance of sludge, using non-radioactive sludge simulants. A third paper will document pilot scale CFD modeling for comparison to experimental pilot scale test results for both blending tests and sludge disturbance tests. That paper will also describe full scale CFD results. The final paper will document additional blending test results for stratified layers in salt solutions, scale up techniques, final full scale pump design recommendations, and operational recommendations. Specifically, this paper documents a series of pilot scale tests, where sludge simulant disturbance due to a blending pump or transfer pump are investigated. A principle design requirement for a blending pump is UoD, where Uo is the pump discharge nozzle velocity, and D is the nozzle diameter. Pilot scale test results showed that sludge was undisturbed below UoD = 0.47 ft{sup 2}/s, and that below UoD = 0.58 ft{sup 2}/s minimal sludge disturbance was observed. If sludge is minimally disturbed, hydrogen will not be released. Installation requirements were also determined for a transfer pump which will remove tank contents, and which is also required to not disturb sludge. Testing techniques and test results for both types of pumps are presented.

08 HYDROGEN↗

INNOVATIVE TECHNIQUES AND TECHNOLOGY APPLICATION IN MANAGEMENT OF REMOTE HANDLED AND LARGE SIZED MIXED WASTE FORMS

CH2M HILL Hanford Group, Inc. (CH2M HILL) plays a critical role in Hanford Site cleanup for the U. S. Department of Energy, Office of River Protection (ORP). CH2M HILL is responsible for the management of 177 tanks containing 53 million gallons of highly radioactive wastes generated from weapons production activities from 1943 through 1990. In that time, 149 single-shell tanks, ranging in capacity from 50,000 gallons to 500,000 gallons, and 28 double-shell tanks with a capacity of 1 million gallons each, were constructed and filled with toxic liquid wastes and sludges. The cleanup mission includes removing these radioactive waste solids from the single-shell tanks to double-shell tanks for staging as feed to the Waste Treatment Plant (WTP) on the Hanford Site for vitrification of the wastes and disposal on the Hanford Site and Yucca Mountain repository. Concentrated efforts in retrieving residual solid and sludges from the single-shell tanks began in 2003; the first tank retrieved was C-106 in the 200 East Area of the site. The process for retrieval requires installation of modified sluicing systems, vacuum systems, and pumping systems into existing tank risers. Inherent with this process is the removal of existing pumps, thermo-couples, and agitating and monitoring equipment from the tank to be retrieved. Historically, these types of equipment have been extremely difficult to manage from the aspect of radiological dose, size, and weight of the equipment, as well as their attendant operating and support systems such as electrical distribution and control panels, filter systems, and mobile retrieval systems. Significant effort and expense were required to manage this new waste stream and resulted in several events over time that were both determined to be unsafe for workers and potentially unsound for protection of the environment. Over the last four years, processes and systems have been developed that reduce worker exposures to these hazards, eliminate violations of RCRA storage regulations, reduce costs for waste management by nearly 50 percent, and create a viable method for final treatment and disposal of these waste forms that does not impact retrieval project schedules. This paper is intended to provide information to the nuclear and environmental clean-up industry with the experience of CH2M HILL and ORP in managing these highly difficult waste streams, as well as providing an opportunity for sharing lessons learned, including technical methods and processes that may be applied at other DOE sites.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Investigation of Waste Feed Delivery Tank Mixing and Sampling Issues

The Hanford tank farms contractor will deliver waste to the Waste Treatment Plant (WTP) from a staging double-shell tank. The WTP broadly classifies waste it receives in terms of “Envelopes,” each with different limiting properties and composition ranges. Envelope A, B, and C wastes are liquids that can include up to 4% entrained solids that can be pumped directly from the staging DST without mixing. Envelope D waste contains insoluble solids and must be mixed before transfer. The mixing and sampling issues lie within Envelope D solid-liquid slurries. The question is how effectively these slurries are mixed and how representative the grab samples are that are taken immediately after mixing. This report summarizes the current state of knowledge concerning jet mixing of wastes in underground storage tanks. Waste feed sampling requirements are listed, and their apparent assumption of uniformity by lack of a requirement for sample representativeness is cited as a significant issue. The case is made that there is not an adequate technical basis to provide such a sampling regimen because not enough is known about what can be achieved in mixing and distribution of solids by use of the baseline submersible mixing pump system. A combined mixing-sampling test program is recommended to fill this gap. Historical Pacific Northwest National Laboratory project and tank farms contractor documents are used to make this case. A substantial investment and progress are being made to understand mixing issues at the WTP. A summary of the key WTP activities relevant to this project is presented in this report. The relevant aspects of the WTP mixing work, together with a previously developed scaled test strategy for determining solids suspension with submerged mixer pumps (discussed in Section 3) provide a solid foundation for developing a path forward.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Behavior of fluids in a weightless environment

Fluid behavior in a low-g environment is controlled primarily by surface tension forces. Certain fluid and system characteristics determine the magnitude of these forces for both a free liquid surface and liquid in contact with a solid. These characteristics, including surface tension, wettability or contact angle, system geometry, and the relationships governing their interaction, are discussed. Various aspects of fluid behavior in a low-g environment are then presented. This includes the formation of static interface shapes, oscillation and rotation of drops, coalescence, the formation of foams, tendency for cavitation, and diffusion in liquids which were observed during the Skylab fluid mechanics science demonstrations. Liquid reorientation and capillary pumping to establish equilibrium configurations for various system geometries, observed during various free-fall (drop-tower) low-g tests, are also presented. Several passive low-g fluid storage and transfer systems are discussed. These systems use surface tension forces to control the liquid/vapor interface and provide gas-free liquid transfer and liquid-free vapor venting.

Fester, D. A.↗

Field Performance of Heat Pump Water Heaters in the Northeast

Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel artificial neural network model for instantaneous power losses and operational efficiency mapping of MW-scale vanadium redox flow battery for improved technoeconomic analysis

A novel data-driven, machine-learning-based method for modeling the instantaneous power losses of a distribution-sited 2 MW/8MWh vanadium redox flow battery (VRFB), a grid-scale electrochemical storage technology, is introduced and compared against benchmark empirical modeling approaches, including symmetric and asymmetric models, as well as a recent convex hull modeling approach. The novel loss modeling method introduces several advantages over the benchmark models and over simplistic efficiency estimates, the most significant of which is that the model can accurately reflect the stepwise and non-linear parasitic losses associated with the duty cycles of mechanical auxiliary systems like pump motor drives and blower fans. Residuals of the models are compared; the proposed data driven model features significantly improved accuracy over the benchmark models. The model's coefficient of determination is also improved relative to that of the benchmark models. Furthermore, a novel method for visualization of operational efficiency of the grid-scale storage technology is introduced. To demonstrate the benefits of the novel data-driven method for modeling the VRFB, the benchmark models and the proposed models are embedded into an Open DSS distribution network model to study two applications of the grid-scale electrical storage system: load leveling for grid support and energy arbitrage. This article demonstrates that the accuracy of the instantaneous power loss model significantly impacts the understanding of the state of charge of the VRFB. In turn, the accuracy of the efficiency modeling of the VRFB impacts the understanding of the potential economic value and technical benefits to the distribution network operators. In conclusion, the presented power loss modeling approach is, therefore, highly relevant for utility-stakeholders, battery asset owners, system engineers, system designers, and financial planners interested in evaluating or optimizing the operation of grid-scale VRFBs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nanowire liquid pumps

Explore the source record for details and available documents.

bio-inspired, energy storage (including batteries ↗

Tribological behavior of ceramic-alloy bearing contacts in molten salt lubrication for concentrating solar power

Molten salts are considered as candidate heat transfer fluids and thermal energy storage media for next generation concentrating solar power (CSP). A molten salt circulates inside the piping and heat exchanger and also functions as a lubricant for the sleeve bearings of the CSP pump. Furthermore, wear- and corrosion-resistant high-temperature bearing materials are critical for the pump efficiency and durability. This study evaluated the tribological performance of candidate bearing materials in lubrication of a molten chloride salt mixture (20% NaCl + 40% MgCl 2 + 40% KCl) at 750 °C in an inert argon gas (a simulative CSP pump environment). Six ceramic-alloy pairs were tested, zirconia and silicon nitride against Haynes 244, Hastelloy C276, and Tribaloy T900 alloy, and ranked by the friction coefficient and wear loss. Characterization of worn surfaces suggested the wear mechanism as a combination of abrasion, adhesion, and tribocorrosion. Results from this study provide fundamental insight for the development and selection of bearing materials for molten salt powered CSP pumps.

14 SOLAR ENERGY↗

Blue emission from Eu{sup 2+}-doped high silica glass by near-infrared femtosecond laser irradiation

Eu{sup 2+}-doped high silica glass (HSG) is fabricated by sintering porous glass which is impregnated with europium ions. Eu{sup 2+}-doped HSG is revealed to yield intense blue emission excited by ultraviolet (UV) light and near-infrared femtosecond laser. The emission profile obtained by UV excitation can be well traced by near-infrared femtosecond laser. The upconversion emission excited by 800 nm femtosecond laser is considered to be related to a two-photon absorption process from the relationship between the integrated intensity and the pump power. A tentative scheme of upconverted blue emission from Eu{sup 2+}-doped HSG was also proposed. The HSG materials presented herein are expected to find applications in high density optical storage and three-dimensional color displays.

36 MATERIALS SCIENCE↗

Impact analysis of heating electrification in US buildings with geothermal heat pumps

Few studies have investigated the impacts of large-scale deployment of geothermal heat pumps (GHPs, also called ground source heat pumps) on the electric grid. GHPs utilize the ground as a heat source to warm buildings more efficiently than other space-heating systems. The coupling with the ground offers seasonal thermal storage so that GHPs can also cool buildings in summer more efficiently than other space-cooling systems. This study simulated the performance of GHP systems for various commercial and residential buildings in 15 climate zones in the United States. Combined with the latest End-Use Load Profiles of the US building stock and grid modeling, this study aims to assess the impacts of a national deployment of GHP systems on the US electric grid in terms of energy consumption, emissions, and operational resilience. The preliminary results show that the GHP deployment can save 429 billion kWh of electricity (a 19% reduction from baseline) and reduce carbon emissions by 496 million tons per year (a 31 % reduction from baseline). A geographical view of the results indicates that retrofitting existing HVAC systems with new GHP systems can lead to further reductions in annual electricity consumption and peak electricity demand in the southern regions of the United States than in other parts of the country. On the other hand, GHP retrofits result in higher percentages of site energy savings and carbon emission reduction in the north (cold climates) than in the south (warm climates).

Liu, Xiaobing↗

An HPC-Based Hydrothermal Finite Element Simulator for Modeling Underground Response to Community-Scale Geothermal Energy Production

Geothermal heat, as renewable energy, shows great advantage with respect to its environmental impact due to its significantly lower CO2 emissions than conventional fossil fuel. Open and closed-loop geothermal heat pumps, which utilize shallow geothermal systems, are an efficient technology for cooling and heating buildings, especially in urban areas. Integrated use of geothermal energy technologies for district heating, cooling, and thermal energy storage can be applied to optimize the subsurface for communities to provide them with multiple sustainable energy and community resilience benefits. The utilization of the subsurface resources may lead to a variation in the underground environment, which might further impact local environmental conditions. However, very few simulators can handle such a highly complex set of coupled computations on a regional or city scale. We have developed high-performance computing (HPC) based hydrothermal finite element (FE) simulator that can simulate the subsurface and its hydrothermal conditions at a scale of tens of km. The HPC simulator enables us to investigate the subsurface thermal and hydrologic response to the built underground environment (such as basements and subways) at the community scale. In this study, a coupled hydrothermal simulator is developed based on the open-source finite element library deal.II. The HPC simulator was validated by comparing the results of a benchmark case study against COMSOL Multiphysics, in which Aquifer Thermal Energy Storage (ATES) is modeled and a process of heat injection into ATES is simulated. The use of an energy pile system at the Treasure Island redevelopment site (San Francisco, CA, USA) was selected as a case study to demonstrate the HPC capability of the developed simulator. The simulator is capable of modeling multiple city-scale geothermal scenarios in a reasonable amount of time.

Sun, Xiang↗

Design considerations for concentrating solar power tower systems employing molten salt.

The Solar Two Project was a United States Department of Energy sponsored project operated from 1996 to 1999 to demonstrate the coupling of a solar power tower with a molten nitrate salt as a heat transfer media and for thermal storage. Over all, the Solar Two Project was very successful; however many operational challenges were encountered. In this work, the major problems encountered in operation of the Solar Two facility were evaluated and alternative technologies identified for use in a future solar power tower operating with a steam Rankine power cycle. Many of the major problems encountered can be addressed with new technologies that were not available a decade ago. These new technologies include better thermal insulation, analytical equipment, pumps and values specifically designed for molten nitrate salts, and gaskets resistant to thermal cycling and advanced equipment designs.

25 ENERGY STORAGE↗

Risk Management of NPP Incidents

A diagnostic model for managing the risk of NPP incidents attending different irregularities of equipment operation is examined for the example of the oil delivery system of the main circulation pump. The model includes the construction of a graph of the operation of the oil system and ranking in order to obtain indices of priority for monitoring information flow that reflect the actuation probability of each form of protection. The results of the analysis can used as input data for predicting the duration of a stable state of a technological system in the course of operation on the basis of stochastic extrapolation of the parameters by means of single-channel queuing systems with finite storage – technological protection and blocking.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Solid-State Thermodynamic Vent System for Control of Cryogenic Propellants

A Solid-State Thermodynamic Vent System (STVS) is a novel Cryogenic Fluid Management (CFM) technology for spacecraft cryogenic propellant tanks that may reduce boiloff while providing greater control over the propellent condition. By exploiting the vacuum-induced cryocooling potential of cryogen-saturated silica aerogel material, an internal STVS heat exchanger expels some sacrificial cryogenic propellant to the vacuum of space to produce cooling within the storage tank. This cooling is transferred directly to the stored fluid, thereby reducing boiloff and increasing hold times. The primary STVS project objective was to design and build a bespoke STVS heat exchanger that employed aerogel blanket material and perform a ground demonstration of the technology using liquid nitrogen (LN2) as the cryogenic propellant. This demonstration aimed to prove that an STVS can have a positive influence on the tank boiloff, shown through a reduction in mass flow rate out of the system during operation, and exercise control over the tank pressure. Testing proved the effectiveness of the concept by reducing the LN2 boiloff rate and tank pressure by roughly 70% and 77% respectively during a single pump-down cycle, which sacrificed around 1.8 kg of propellant.

Propellant Production↗

Cryogenic System for the Cryomodule Test Facility at Fermilab

This paper provides an overview of the current progress and near-future plans for the cryogenic system at the new Cryomodule Test Facility (CMTF) at Fermilab, which includes the helium compressors, refrigerators, warm vacuum compressors, gas and liquid storage, and a distribution system. CMTF will house the Project X Injector Experiment (PXIE), which is the front end of the proposed Project X. PXIE includes one 162.5 MHz half wave resonator (HWR) cryomodule and one 325 MHz single spoke resonator (SSR) cryomodule. Both cryomodules contain superconducting radio-frequency (SRF) cavities and superconducting magnets operated at 2.0 K. CMTF will also support the Advanced Superconducting Test Accelerator (ASTA), which is located in the adjacent New Muon Lab (NML) building. A cryomodule test stand (CMTS1) located at CMTF will be used to test 1.3 GHz cryomodules before they are installed in the ASTA cryomodule string. A liquid helium pump and transfer line will be used to provide supplemental liquid helium to ASTA.

White, Michael↗