Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector

Purpose: The goal of this study is to evaluate a new method based on a coded aperture mask combined with a digital x-ray imaging detector for measurements of the focal spot sizes of diagnostic x-ray tubes. Common techniques for focal spot size measurements employ a pinhole camera, a slit camera, or a star resolution pattern. The coded aperture mask is a radiation collimator consisting of a large number of apertures disposed on a predetermined grid in an array, through which the radiation source is imaged onto a digital x-ray detector. The method of the coded mask camera allows one to obtain a one-shot accurate and direct measurement of the two dimensions of the focal spot (like that for a pinhole camera) but at a low tube loading (like that for a slit camera). A large number of small apertures in the coded mask operate as a ''multipinhole'' with greater efficiency than a single pinhole, but keeping the resolution of a single pinhole. Methods: X-ray images result from the multiplexed output on the detector image plane of such a multiple aperture array, and the image of the source is digitally reconstructed with a deconvolution algorithm. Images of the focal spot of a laboratory x-ray tube (W anode: 35-80 kVp; focal spot size of 0.04 mm) were acquired at different geometrical magnifications with two different types of digital detector (a photon counting hybrid silicon pixel detector with 0.055 mm pitch and a flat panel CMOS digital detector with 0.05 mm pitch) using a high resolution coded mask (type no-two-holes-touching modified uniformly redundant array) with 480 0.07 mm apertures, designed for imaging at energies below 35 keV. Measurements with a slit camera were performed for comparison. A test with a pinhole camera and with the coded mask on a computed radiography mammography unit with 0.3 mm focal spot was also carried out. Results: The full width at half maximum focal spot sizes were obtained from the line profiles of the decoded images, showing a focal spot of 0.120 mmx0.105 mm at 35 kVp and M=6.1, with a detector entrance exposure as low as 1.82 mR (0.125 mA s tube load). The slit camera indicated a focal spot of 0.112 mmx0.104 mm at 35 kVp and M=3.15, with an exposure at the detector of 72 mR. Focal spot measurements with the coded mask could be performed up to 80 kVp. Tolerance to angular misalignment with the reference beam up to 7 deg. in in-plane rotations and 1 deg. deg in out-of-plane rotations was observed. The axial distance of the focal spot from the coded mask could also be determined. It is possible to determine the beam intensity via measurement of the intensity of the decoded image of the focal spot and via a calibration procedure. Conclusions: Coded aperture masks coupled to a digital area detector produce precise determinations of the focal spot of an x-ray tube with reduced tube loading and measurement time, coupled to a large tolerance in the alignment of the mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise reduction in spectral CT: Reducing dose and breaking the trade-off between image noise and energy bin selection

Purpose: Our purpose was to reduce image noise in spectral CT by exploiting data redundancies in the energy domain to allow flexible selection of the number, width, and location of the energy bins. Methods: Using a variety of spectral CT imaging methods, conventional filtered backprojection (FBP) reconstructions were performed and resulting images were compared to those processed using a Local HighlY constrained backPRojection Reconstruction (HYPR-LR) algorithm. The mean and standard deviation of CT numbers were measured within regions of interest (ROIs), and results were compared between FBP and HYPR-LR. For these comparisons, the following spectral CT imaging methods were used:(i) numerical simulations based on a photon-counting, detector-based CT system, (ii) a photon-counting, detector-based micro CT system using rubidium and potassium chloride solutions, (iii) a commercial CT system equipped with integrating detectors utilizing tube potentials of 80, 100, 120, and 140 kV, and (iv) a clinical dual-energy CT examination. The effects of tube energy and energy bin width were evaluated appropriate to each CT system. Results: The mean CT number in each ROI was unchanged between FBP and HYPR-LR images for each of the spectral CT imaging scenarios, irrespective of bin width or tube potential. However, image noise, as represented by the standard deviation of CT numbers in each ROI, was reduced by 36%-76%. In all scenarios, image noise after HYPR-LR algorithm was similar to that of composite images, which used all available photons. No difference in spatial resolution was observed between HYPR-LR processing and FBP. Dual energy patient data processed using HYPR-LR demonstrated reduced noise in the individual, low- and high-energy images, as well as in the material-specific basis images. Conclusions: Noise reduction can be accomplished for spectral CT by exploiting data redundancies in the energy domain. HYPR-LR is a robust method for reducing image noise in a variety of spectral CT imaging systems without losing spatial resolution or CT number accuracy. This method improves the flexibility to select energy bins in the manner that optimizes material identification and separation without paying the penalty of increased image noise or its corollary, increased patient dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction

Purpose: The ionizing radiation imparted to patients during computed tomography exams is raising concerns. This paper studies the performance of a scheme called dose reduction using prior image constrained compressed sensing (DR-PICCS). The purpose of this study is to characterize the effects of a statistical model of x-ray detection in the DR-PICCS framework and its impact on spatial resolution. Methods: Both numerical simulations with known ground truth and in vivo animal dataset were used in this study. In numerical simulations, a phantom was simulated with Poisson noise and with varying levels of eccentricity. Both the conventional filtered backprojection (FBP) and the PICCS algorithms were used to reconstruct images. In PICCS reconstructions, the prior image was generated using two different denoising methods: a simple Gaussian blur and a more advanced diffusion filter. Due to the lack of shift-invariance in nonlinear image reconstruction such as the one studied in this paper, the concept of local spatial resolution was used to study the sharpness of a reconstructed image. Specifically, a directional metric of image sharpness, the so-called pseudopoint spread function (pseudo-PSF), was employed to investigate local spatial resolution. Results: In the numerical studies, the pseudo-PSF was reduced from twice the voxel width in the prior image down to less than 1.1 times the voxel width in DR-PICCS reconstructions when the statistical model was not included. At the same noise level, when statistical weighting was used, the pseudo-PSF width in DR-PICCS reconstructed images varied between 1.5 and 0.75 times the voxel width depending on the direction along which it was measured. However, this anisotropy was largely eliminated when the prior image was generated using diffusion filtering; the pseudo-PSF width was reduced to below one voxel width in that case. In the in vivo study, a fourfold improvement in CNR was achieved while qualitatively maintaining sharpness; images also had a qualitatively more uniform noise spatial distribution when including a statistical model. Conclusions: DR-PICCS enables to reconstruct CT images with lower noise than FBP and the loss of spatial resolution can be mitigated to a large extent. The introduction of statistical modeling in DR-PICCS may improve some noise characteristics, but it also leads to anisotropic spatial resolution properties. A denoising method, such as the directional diffusion filtering, has been demonstrated to reduce anisotropy in spatial resolution effectively when it was combined with DR-PICCS with statistical modeling.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-T-02: Exploring Radiation Acoustics CT Dosimeter Design Aspects for Proton Therapy

Purpose: Investigate the design aspects and imaging dose capabilities of the Radiation Acoustics Computed Tomography (RA CT) dosimeter for Proton induced acoustics, with the objective to characterize a pulsed pencil proton beam. The focus includes scanner geometry, transducer array, and transducer bandwidth on image quality. Methods: The geometry of the dosimeter is a cylindrical water phantom (length 40cm, radius 15cm) with 71 ultrasound transducers placed along the length and end of the cylinder to achieve a weighted set of projections with spherical sampling. A 3D filtered backprojection algorithm was used to reconstruct the dosimetric images and compared to MC dose distribution. First, 3D Monte Carlo (MC) Dose distributions for proton beam energies (range of 12cm, 16cm, 20cm, and 27cm) were used to simulate the acoustic pressure signal within this scanner for a pulsed proton beam of 1.8x107 protons, with a pulse width of 1 microsecond and a rise time of 0.1 microseconds. Dose comparison within the Bragg peak and distal edge were compared to MC analysis, where the integrated Gaussian was used to locate the 50% dose of the distal edge. To evaluate spatial fidelity, a set of point sources within the scanner field of view (15×15×15cm3) were simulated implementing a low-pass bandwidth response function (0 to 1MHz) equivalent to a multiple frequency transducer array, and the FWHM of the point-spread-function determined. Results: From the reconstructed images, RACT and MC range values are within 0.5mm, and the average variation of the dose within the Bragg peak are within 2%. The spatial resolution tracked with transducer bandwidth and projection angle sampling, and can be kept at 1.5mm. Conclusion: This design is ready for fabrication to start acquiring measurements. The 15 cm FOV is an optimum size for imaging dosimetry. Currently, simulations comparing transducer sensitivity, bandwidth, and proton beam parameters are being evaluated to assess signal-to-noise.

07 ISOTOPE AND RADIATION SOURCES↗

WE-EF-207-04: An Inter-Projection Sensor Fusion (IPSF) Approach to Estimate Missing Projection Signal in Synchronized Moving Grid (SMOG) System

Purpose: A synchronized moving grid (SMOG) has been proposed to reduce scatter and lag artifacts in cone beam computed tomography (CBCT). However, information is missing in each projection because certain areas are blocked by the grid. A previous solution to this issue is acquiring 2 complimentary projections at each position, which increases scanning time. This study reports our first Result using an inter-projection sensor fusion (IPSF) method to estimate missing projection in our prototype SMOG-based CBCT system. Methods: An in-house SMOG assembling with a 1:1 grid of 3 mm gap has been installed in a CBCT benchtop. The grid moves back and forth in a 3-mm amplitude and up-to 20-Hz frequency. A control program in LabView synchronizes the grid motion with the platform rotation and x-ray firing so that the grid patterns for any two neighboring projections are complimentary. A Catphan was scanned with 360 projections. After scatter correction, the IPSF algorithm was applied to estimate missing signal for each projection using the information from the 2 neighboring projections. Feldkamp-Davis-Kress (FDK) algorithm was applied to reconstruct CBCT images. The CBCTs were compared to those reconstructed using normal projections without applying the SMOG system. Results: The SMOG-IPSF method may reduce image dose by half due to the blocked radiation by the grid. The method almost completely removed scatter related artifacts, such as the cupping artifacts. The evaluation of line pair patterns in the CatPhan suggested that the spatial resolution degradation was minimal. Conclusion: The SMOG-IPSF is promising in reducing scatter artifacts and improving image quality while reducing radiation dose.

60 APPLIED LIFE SCIENCES↗

SU-F-T-664: The Efficacy of Gold Nanoparticles as Contrast Agents in Mice

Purpose: Micro-Computed Tomography (micro-CT) has been widely used as a non-invasive, high-resolution imaging modality in preclinical research. However, tumors cannot be well distinguished, since their density are similar to those of surrounding tissues, and the tumors’ natural contrast is very low. The benefits of using Gold Nanoparticles (AuNPs) as a promising high atomic weight contrast agent have been published in recent years. The aim of this study is to investigate the efficacy of AuNPs as contrast agents using different energy x-rays. Methods: The left flank of an immune-compromised athymic nude mouse was implanted with subcutaneous xenograft model of human lung cancer line, A549 cells (from ATCC). After 14 days, this mouse was imaged with dual energy cone-beam micro-CT. The selected energies were 45 kVp and 65 kVp. 10µg AuNPs (200 µg/ml concentration) approximately 12 nm in size were injected subcutaneously into the tumor. The mouse was imaged 0, 3 and 24 hours post-injection. During scanning, this mouse was anesthetized. All projection raw data have been optimized and then images were reconstructed with the FDK Algorithm. Results: Based on images, at 0 hour, AuNPs provided obvious contrast no matter which energy selected, 45 kVp or 65 kVp; and using 45 kVp X-ray, AuNps showed greater contrast. After 3 hours or evenand longer, AuNPs distributed throughout the whole body of mouse, and they were not shown clearly shown in the images. Conclusion: In this study, we investigated the efficacy of AuNPs as image contrast agents at different energies with dual-energy micro-CT, using 200µg/mL of AuNPs. Sufficiently high concentrations of AuNPs are needed to be able to track intratumoral distribution. Images showed good contrast immediately following the administration of the agent but results were poor after 3 hours.

60 APPLIED LIFE SCIENCES↗

Sci-Thur AM: YIS – 02: Imaging dose distributions through the detection of radiation-induced acoustic waves

Purpose: X-ray acoustic computed tomography (XACT) is an emerging technique that images the dose deposited within an object following linac irradiation by detecting acoustic waves induced via the photoacoustic effect. This work shows that XACT images can be formed in soft-tissue equivalent material and that dosimetric information can be extracted from such images. Methods: Acoustic waves induced in a water tank following irradiation by a 10 MV flattening filter free photon beam were detected with an immersion ultrasound transducer at 60 angles surrounding the radiation field. A back-projection algorithm was used to reconstruct an XACT image from the detected transducer signals. Profiles extracted from XACT images were compared to profiles measured with ion chambers as per the current clinical protocol. Results: XACT images were successfully formed of simple 4 cm × 4 cm and 6 cm × 3 cm fields, as well as of more complicated multi-leaf collimator defined fields. For the 6 cm × 3 cm field, 74% and 87% of the XACT profile points in the 6 cm and 3 cm dimensions, respectively, passed a 7% / 4 mm gamma test when compared to ion chamber measurements. In a complicated puzzle piece shaped field, 86% of the pixels in an extracted profile passed a 7% / 4 mm gamma test. Conclusions: XACT is capable of imaging the dose distribution delivered by a variety of field sizes and shapes in water, and is a viable technique for both water tank and in vivo dosimetry.

60 APPLIED LIFE SCIENCES↗

Real-time High-resolution X-Ray Computed Tomography

Computed Tomography (CT) serves as a key imaging technology that relies on computationally intensive filtering and back-projection algorithms for 3D image reconstruction. While conventional high-resolution image reconstruction (> 2K3) solutions provide quick results, they typically treat reconstruction as an offline workload to be performed remotely on large-scale HPC systems. The growing demand for post-construction AI-driven analytics and the need for real-time adjustments call for high-resolution reconstruction solutions that are feasible on local computing resources, i.e. a multi-GPU server at most. In this paper, we propose a novel approach that utilizes Tensor Cores to optimize image reconstruction without sacrificing precision. We also introduce a framework designed to enable real-time execution of end-to-end distributed image reconstruction in a multi-GPU environment. Evaluations conducted on a single Nvidia A100 and H100 GPU show performance improvements of 1.91 × and 2.15 × compared to highly optimized production libraries. Furthermore, our framework, when deployed on 8-card Nvidia A100 GPU system, demonstrates the ability to reconstruct real-world datasets into 20483 volumes (32 GB) in slightly more than one minute and 40963 volumes (256 GB) in 7 minutes.

Wu, Du↗

Direct coupling of tomography and ptychography

We present a generalization of the ptychographic phase problem for recovering refractive properties of a three-dimensional object in a tomography setting. Our approach, which ignores the lateral overlapping probe requirements in existing ptychography algorithms, can enable the reconstruction of objects using highly flexible acquisition patterns and pave the way for sparse and rapid data collection with lower radiation exposure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Developing a data-driven method to constrain the antiproton background in the Mu2e experiment

The Mu2e experiment will search for CLFV neutrinoless coherent muon to electron conversion in the field of an Al nucleus. The expected signal is a 104.97 MeV/c monochromatic $e^-$ (CE). CE-like $e^-$’s could also come from $\bar{p}$’s annihilating in the Stopping Target (ST). The background induced by $\bar{p}$’s is expected to be low but has a large systematic uncertainty. It cannot be suppressed by the time window cut used to reduce the prompt background. However, $p\bar{p}$ annihilation in the ST is the only source of events in the Mu2e detector with multiple tracks coming from the ST, simultaneous in time, each with a momentum in the signal window region. We exploited this unique feature and developed algorithms to identify and reconstruct multi-track events. This paper discusses the status and prospects of this data-driven method to constrain the $\bar{p}$ background at Mu2e.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of $Z/\gamma^* + b$-jet Production Cross section in $p\bar{p}$ collisions at $\sqrt{s}= 1.96$ TeV with the CDF detector

Processes at hadron colliders, such as the production of jets, are described by the Quantum Chromodynamics theory (QCD). Precise descriptions of processes involving jets in association with a vector boson have nowadays large relevance as they represent irreducible background to other Standard Model (SM) processes and searches for new physics. The experimental study and understanding of the b-jet production in association with a Z boson are crucial for many reasons. For one side, it is the most important background for a light Higgs boson decaying into a bottom-antibottom quark pair and produced in the ZH mode.This is one of the most promising channels for the Higgs search at Tevatron in particular since the latest results have excluded the high mass region (MH > 127 GeV/c 2 ). For another side the signature of b-jets and a Z boson is also background to new physics searches, such as supersymmetry, where a large coupling of the Higgs boson to bottom quarks is allowed. The produ ction cross section measurement of b-jets in events with a Z boson has already been performed at hadron colliders, at the Tevatron by CDF and D0 experiments and are now pursued at the LHC by ATLAS and CMS. In particular the CDF measurement was performed with only 2 fb -1 and was limited by the statistical uncertainty. This PhD thesis presents a new measurement of the $Z/\gamma^* + b$-jet production cross section using the complete dataset collected by CDF during the Run II. $Z/\gamma^*$ bosons are selected in the electron and muon decay modes and are required to have 66 < MZ < 116 GeV/c 2 while jets, reconstructed with the MidPoint algorithm, have to be central (|Y| < 1.5) with pT > 20 GeV/c . The per jet cross section is measured with respect to the $Z/\gamma^*$ inclusive and the $Z/\gamma^* +$ jets cross sections. Results are compared to leading order (LO) event generator plus parton shower and next-to-leading order (NLO) predictions corrected for non perturbative effects such as hadronizat ion and underlying event. Differential distributions as a fu! nction of jet transverse moment and jet rapidity are also presented together with the comparison to NLO pQCD predictions for different renormalization and factorization scales and various PDF sets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the ratio $B(t \to W b)/B(t \to W q)$ in $t\bar{t}$ dilepton channel at CDF

My analysis is based on the number of b-jets found in t¯t events using the dilepton sample with at least 2 jets in the final state. The charged leptons could be either electrons or muons. Tau leptons are not included. We use SecVtx algorithm, based on the reconstruction of a secondary vertex in the event, in order to identify a jet coming from b-quark fragmentation (b-tagging). Due to the high purity of the t¯t signal in dilepton events it is possible to perform a kinematic measurement of the t¯t cross section. Our strategy is to use this result to make prediction on the number of t¯t events. We divide our sample in subsets according to dilepton type (combination of the lepton type), number of jets in the final states and events with zero, one or two tags. The comparison between events and the prediction, given by the sum of the expected t¯t estimate and the background yield, in each subsample is made using a Likelihood function. Our measured value for R is the one which maximizes the Likelihood, i.e. gives the best match between our expectation and the observed data. We measure: p¯p!t¯t = 7.05±0.53stat±0.42lumi , R= 0.86±0.06 (stat+syst) and, in the hypothesis of CKM matrix unitarity with three quark generations, | Vtb | = 0.93 ± 0.03. Our analysis on the p¯p!t¯t was performed independently of the official dilepton analisys on the t¯t production cross section. So it represents also a valuable crosscheck for the official analysis. In chapter 1, a brief introduction to the theoretical framework is given. The standard model of elementary particles and the Quantum Cromodynamic theories are introduced. Then the top quark is presented, with a short descpription of its properties, as its mass, its production mode and its cross section. Some previous results on R are listed as well. Later we present the experiment that collected our data, both the collider (chapter 2) and the detector (CDF)(chapter 3). In chapter 4 we describe the physics object reconstruction, so how we collect the detector signals and translate those into physical particles traversing our detector. The event selection is described in chapter 5, where we report the complete list of the selection requirements and we estimate our sample composition. In chapters 6 and 7 we report our results for the t¯t production cross section and R. An indirect measurement for |Vtb| is given as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LArIAT In 10 Minutes [Slides]

The LArIAT (Liquid Argon In A Test Beam) experiment at Fermilab's Test Beam Facility exposes a Liquid Argon Time Projection Chamber (LArTPC) to a charged particle test beam in order to calibrate and characterize LArTPCs response. This is a perfect environment in that particle species and momentum can be preselected while event reconstruction tools, particle identification algorithms, and new detector technologies can be tested. The LArIAT exploration of LArTPC capabilities will provide critical input to existing liquid argon neutrino experiments and will help to improve future precision neutrino oscillation measurements such as the Deep Underground Neutrino Experiment (DUNE). The work presented here will give an overview of the experiment and highlight recent results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using Deep Learning Techniques to Search for the MiniBooNE Low Energy Excess in MicroBooNE with > 3$\sigma$ Sensitivity

This thesis describes an analysis developed for the MicroBooNE experiment to investigate an anomalous excess of electron-like events observed in the MiniBooNE detector. The hypothesis investigated here is that the MiniBooNE anomaly represents appearance of electron neutrinos. Using an amalgam of novel Deep Learning and standard algorithmic techniques this analysis reconstructs and identifies a highly pure sample of charged current quasi-elastic muon neutrino and electron neutrino interactions. This thesis describes the steps in the analysis chain and provides data-to-simulation comparisons for each step that establish confidence in the final prediction. When interpreted in the context of a $\nu e$ appearance like model, this analysis predicts a 3.2$\sigma$ sensitivity to exclude a standard model fluctuation which would appear as a MiniBooNE like anomaly using $7\times10^{20}$ protons on target of MicroBooNE Data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components. Third Annual Progress Report

Additive manufacturing (AM) of high-strength corrosion resistance alloys for nuclear energy applications, such as stainless steel and Inconel, is currently based on laser powder bed fusion (LPBF) process. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Probability of crack initiation at the pore depends on size, shape, and orientation of the defect. Pulsed Infrared Thermography Imaging (PIT) provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PIT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PIT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. Following initial qualification of an AM component for deployment in a nuclear reactor, a PIT system can also be used for in-service nondestructive evaluation (NDE) applications. In this report, we describe recent progress in enhancing PIT capabilities in detecting microscopic subsurface defects in metals, and classifying shapes and orientation of pores in thermal images. For detection of microscopic defects in PIT imaging data, we have developed Spatial Temporal Denoised Thermal Source Separation (STDTSS) unsupervised machine learning (ML) image processing algorithm. We show that flat bottom hole (FBH) defects as small as 200µm in SS316 and IN718 specimens, can be detected with STDTSS algorithm. To the best of our knowledge, these are the smallest detected defects which are reported in literature. For classification of defects shapes, we have previously developed thermal tomography (TT) algorithm to obtain depth reconstructions of material defects from data cube of sequentially recorded surface temperatures. However, interpretation of TT images is non-trivial because of blurring with increasing depth. To address this challenge, we have developed a deep learning convolutional neural network (CNN) to classify size and orientation subsurface defects in simulated TT images.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Start of Combustion Sensor Phases I and II-A: Feasibility Demonstration, Design and Optimization

Homogeneous Compressed Charge Ignition (HCCI) has elevated the need for Start of Combustion (SOC) sensors. HCCI engines have been the exciting focus of engine research recently, primarily because HCCI offers higher thermal efficiency than the conventional Spark Ignition (SI) engines and significantly lower NOx and soot emissions than conventional Compression Ignition (CI) engines, and could be fuel neutral. HCCI has the potential to unify all the internal combustion engine technology to achieve the high-efficiency, low-emission goal. However, these advantages do not come easy. It is well known that the problems encountered with HCCI combustion center on the difficulty of controlling the Start of Combustion. TIAX has an SOC sensor under development which has shown promise. In previous work, including a DOE-sponsored SBIR project, TIAX has developed an accelerometer-based method which was able to determine SOC within a few degrees crank angle for a range of operating conditions. A signal processing protocol allows reconstruction of the combustion pressure event signal imbedded in the background engine vibration recorded by the accelerometer. From this reconstructed pressure trace, an algorithm locates the SOC. This SOC sensor approach is nonintrusive, rugged, and is particularly robust when the pressure event is strong relative to background engine vibration (at medium to high engine load). Phase I of this project refined the previously developed technology with an engine-generic and robust algorithm. The objective of the Phase I research was to answer two fundamental questions: Can the accelerometer-based SOC sensor provide adequate SOC event capture to control an HCCI engine in a feedback loop? And, will the sensor system meet cost, durability, and software efficiency (speed) targets? Based upon the results, the answer to both questions was 'YES'. The objective of Phase II-A was to complete the parameter optimization of the SOC sensor prototype in order to reach a juncture where plans can be and are discussed with an industry partner for how best to perform a more detailed implementation of the TIAX SOC technology on an HCCI engine system. This occurred, as evidenced the number of potential commercialization partners shown in Table 4. Potential Commercialization Partners Contacted (up to date as of January 31, 2010). During the two phases, a robust, engine-generic algorithm was developed that met the desired targets and was shown to work extremely well for HCCI engine operation.

33 ADVANCED PROPULSION SYSTEMS↗

Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics

The Large Hadron Collider (LHC) at CERN promises a major step forward in the understanding of the fundamental nature of matter. The ATLAS experiment is a general-purpose detector for the LHC, whose design was guided by the need to accommodate the wide spectrum of possible physics signatures. The major remit of the ATLAS experiment is the exploration of the TeV mass scale where groundbreaking discoveries are expected. In the focus are the investigation of the electroweak symmetry breaking and linked to this the search for the Higgs boson as well as the search for Physics beyond the Standard Model. In this report a detailed examination of the expected performance of the ATLAS detector is provided, with a major aim being to investigate the experimental sensitivity to a wide range of measurements and potential observations of new physical processes. An earlier summary of the expected capabilities of ATLAS was compiled in 1999 [1]. A survey of physics capabilities of the CMS detector was published in [2]. The design of the ATLAS detector has now been finalised, and its construction and installation have been completed [3]. An extensive test-beam programme was undertaken. Furthermore, the simulation and reconstruction software code and frameworks have been completely rewritten. Revisions incorporated reflect improved detector modelling as well as major technical changes to the software technology. Greatly improved understanding of calibration and alignment techniques, and their practical impact on performance, is now in place. The studies reported here are based on full simulations of the ATLAS detector response. A variety of event generators were employed. The simulation and reconstruction of these large event samples thus provided an important operational test of the new ATLAS software system. In addition, the processing was distributed world-wide over the ATLAS Grid facilities and hence provided an important test of the ATLAS computing system - this is the origin of the expression 'CSC studies' ('computing system commissioning'), which is occasionally referred to in these volumes. The work reported does generally assume that the detector is fully operational, and in this sense represents an idealised detector: establishing the best performance of the ATLAS detector with LHC proton-proton collisions is a challenging task for the future. The results summarised here therefore represent the best estimate of ATLAS capabilities before real operational experience of the full detector with beam. Unless otherwise stated, simulations also do not include the effect of additional interactions in the same or other bunch-crossings, and the effect of neutron background is neglected. Thus simulations correspond to the low-luminosity performance of the ATLAS detector. This report is broadly divided into two parts: firstly the performance for identification of physics objects is examined in detail, followed by a detailed assessment of the performance of the trigger system. This part is subdivided into chapters surveying the capabilities for charged particle tracking, each of electron/photon, muon and tau identification, jet and missing transverse energy reconstruction, b-tagging algorithms and performance, and finally the trigger system performance. In each chapter of the report, there is a further subdivision into shorter notes describing different aspects studied. The second major subdivision of the report addresses physics measurement capabilities, and new physics search sensitivities. Individual chapters in this part discuss ATLAS physics capabilities in Standard Model QCD and electroweak processes, in the top quark sector, in b-physics, in searches for Higgs bosons, supersymmetry searches, and finally searches for other new particles predicted in more exotic models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗