Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability and Integrity Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Incentive-Based Control and Coordination of Distributed Energy Resources. Final Report

The rapid growth of low-inertia renewable energy resources represents an immense opportunity for the U.S. to minimize its carbon footprint, while presenting a challenge for system operators as traditional “spinning” generation resources are displaced. This transformation requires solutions to robustly and cost-effectively manage dynamic changes on the grid while ensuring quality of service. There is growing recognition that distributed energy resources (DERs – loads, distributed generation, storage, electric vehicles, etc.) represent a great potential to perform this function. This report details a scalable hierarchical control strategy for coordinating thousands of heterogeneous DERs in order to provide three ancillary gird services: 1) frequency response, a rapid (within 2 seconds) service used to maintain the grid at 60 Hz; 2) regulation response, a larger response used to balance on-going differences in supply and demand on the grid; and, 3) ramping reserve, used to bring on capacity to replace lost generation. The developed control architecture consists of 1) a Distribution Reliability Coordinator (DRC), 2) aggregator controllers, and finally, 3) DER controllers. The DRC coordinates all the flexible loads and distributed energy resources on the distribution system and bids the aggregate flexibility into the wholesale market. The DRC also performs resource allocation (deciding how the flexible devices on the distribution system will be dispatched) to meet the requirements for each of the three ancillary services. The aggregators control a collection of devices that are geographically co-located and provide a platform to aggregate their flexibility and mitigate uncertainty associated with a single flexible load by managing a large aggregation of similar loads (so that any stochastic effects average out). Finally, DER controllers (for example, thermostats for air conditioners, chargers for electric vehicles) adjust the power consumption of individual devices to ensure accurate and reliable delivery of the requested grid services. Evaluation and validation of this approach was conducted with a mixture of simulation and hardware testing for a range of DERs in residential (air conditioners and water heaters), commercial HVAC (ventilation fans and central chiller plants), and micro-grids (battery energy storage, solar PV etc.). This culminated in DER hardware and simulation models operating in conjunction with grid simulations as part of a large scale federated test-bed demonstration. Simulations of over 10,000 controllable residential devices (a combination of air conditioners, water heaters, batteries, and electric vehicles) demonstrated that this advanced control approach could simultaneously meet all three grid services. Furthermore, hardware-in-the-loop testing was performed with operational micro-grid and commercial building HVAC equipment. The micro-grid equipment (representing PV, battery storage, and back-up generators) demonstrated the ability to meet all frequency response requirements (except ramping time). The commercial building HVAC ventilation equipment successfully provided the regulating response service. An Industry Advisory Board (IAB) was formed and engaged throughout the project to get feed-back on project risks and potential commercialization barriers. Their input was invaluable in identify key risks stemming from regulatory and market access challenges, financial risks from under-performance, and competitive threats from utility-scale solutions such as integrated storage. A phased commercialization plan was developed that addresses continued risk reduction (value proposition refinement and performance uncertainty assessments), piloting through field demonstrations with key stakeholders, and finally, deployment as an emerging standard for DER control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Integrated Hydrological and Water Management Study of the Entire Nile River System - Lake Victoria to Nile Delta

The Nile basin River system spans 3 million km(exp 2) distributed over ten nations. The eight upstream riparian nations, Ethiopia, Eretria, Uganda, Rwanda, Burundi, Congo, Tanzania and Kenya are the source of approximately 86% of the water inputs to the Nile, while the two downstream riparian countries Sudan and Egypt, presently rely on the river's flow for most of the their needs. Both climate and agriculture contribute to the complicated nature of Nile River management: precipitation in the headwaters regions of Ethiopia and Lake Victoria is variable on a seasonal and inter-annual basis, while demand for irrigation water in the arid downstream region is consistently high. The Nile is, perhaps, one of the most difficult trans-boundary water issue in the world, and this study would be the first initiative to combine NASA satellite observations with the hydrologic models study the overall water balance in a to comprehensive manner. The cornerstone application of NASA's Earth Science Research Results under this project are the NASA Land Data Assimilation System (LDAS) and the USDA Atmosphere-land Exchange Inverse (ALEXI) model. These two complementary research results are methodologically independent methods for using NASA observations to support water resource analysis in data poor regions. Where an LDAS uses multiple sources of satellite data to inform prognostic simulations of hydrological process, ALEXI diagnoses evapotranspiration and water stress on the basis of thermal infrared satellite imagery. Specifically, this work integrates NASA Land Data Assimilation systems into the water management decision support systems that member countries of the Nile Basin Initiative (NBI) and Regional Center for Mapping of Resources for Development (RCMRD, located in Nairobi, Kenya) use in water resource analysis, agricultural planning, and acute drought response to support sustainable development of Nile Basin water resources. The project is motivated by the recognition that accurate, frequent, and spatially distributed estimates of the water balance are necessary for effective water management. This creates a challenge for watersheds that are large, include data poor regions, and/or span multiple nations. All of these descriptors apply to the Nile River basin, yet successful management of the Nile is critical for development and political stability in the region. For this reason, improved hydrological data to support cooperative water management in the Nile basin is a priority for USAID, the US State Department, the World Bank and other international organizations. In this project, the U.S. based research team is working with partners at RCMRD, Nile Basin Initiative (NBI), and their member national-level agencies to develop satellite-based land cover maps, satellite-derived evapotranspiration estimates (using the ALEXI algorithm), and NASA's Land Data Assimilation System (LDAS) customized to match identified information needs. The cornerstone applied sciences product of the project is the development of a customized "Nile LDAS" that will produce optimal estimates of hydrological states and fluxes, as vetted against the in situ observations of NBI and RCMRD member organizations and independent satellite-derived hydrological estimates. Nile LDAS will be applied to improve the reliability of emerging Decision Support Systems in applications that include drought monitoring, reservoir management, and irrigation planning. The end-users such as RCMRD, NBI, Ethiopian and Kenya Meteorological and Famine Early Warning System Network (FEWSNet) will be the eventual benefactors of this work. There will be a capacity building process involving the above end-user organizations and transfer the models and the results for these organizations to execute for future use. The team has already initiated this study and the early results of first years' work are shown. The plan is to complete this work by late 2013.

Habib, Shahid↗

Operational Probabilistic Tools for Solar Uncertainty (OPTSUN) (Final Project Report for DOE Solar Forecasting II Project)

Increasing levels of solar PV can challenge system operations and may require novel methods to operate the power system reliably and efficiently. Power system operating plans generally use deterministic forecasts, in which the variable energy resources are represented by the expected value for each interval of the decision horizon. Probabilistic forecasts are relatively new but have the potential to address the shortfalls of deterministic forecasts. However, understanding how best to use such forecasts is still a key gap in industry and was the focus of this project. The project had three workstreams. In a forecasting workstream, improvements were made to baseline probabilistic forecasts using a number of new approaches such as machine learning methods and improved input data. In a design workstream, advanced simulation tools used these forecasts to investigate newly proposed reserve determination methods. Lastly, in a demonstration workstream a scheduling management platform (SMP) was developed to leverage probabilistic forecasts in a modular and customizable manner. In order to study the benefits that could be accrued, the project team collaborated with three utility partners (Duke Energy, Southern Company and Hawaiian Electric) to deliver improved probabilistic forecasts for each region and to model each region in case studies using advanced production cost modeling tools. Different methods to determine operating reserve requirements from probabilistic forecasts were developed, simulated, and tested across each region. The benefits of using these newly proposed methods varied by utility, but, in general, using probabilistic forecasts as well as historical data to set the reserve requirements seems to improve reliability related results, with less risk of reserve or supply shortfalls. The cost implications were not always straightforward; in some cases the new methods could show a reduction in expected operating costs, but often the increase in reserves associated with better risk mitigation using probabilistic forecasts could result in an increase in operating costs in the simulations. The SMP tool was developed to process probabilistic forecasts from their initial receipt through to scheduling decisions. This open-source tool consists of several modules for scenario development, reserve requirements calculation, and visualization. The SMP tool was demonstrated to a wide range of operators and stakeholders at all three utilities and further improved based on their feedback. The tool will be available on www.epri.com/optsun. The proposed probabilistic information-based reserve determination approaches have the potential to be implemented by different regions to ensure an economic and reliable power system operation on power systems integrating increasing levels of variable renewable resources. The innovative yet practical methods developed in this project demonstrated tangible benefits from using probabilistic forecasts beyond just study-based assessments to include three unique balancing areas. The demonstrated benefits across the multiple utility environments, are expected to provide system operators in all regions the confidence required and a platform to adopt the new forecasting and operating methods.

14 SOLAR ENERGY↗

Reassessment of True Core Collapse Differential Pressure Values for Filter Elements in Safety Critical Environments - 13076

As the areas of application for diverse filter types increases, the mechanics and material sciences associated with the hardware and its relationship with more and more arduous process environments becomes critical to the successful and reliable operation of the filtration equipment. Where the filter is the last safe barrier between the process and the life environment, structural integrity and reliability is paramount in both the validation and the ethical acceptability of the designed equipment. Core collapse is a key factor influencing filter element selection, and is an extremely complex issue with a number of variables and failure mechanisms. It is becoming clear that the theory behind core collapse calculations is not always supported with real tested data. In exploring this issue we have found that the calculation method is not always reflective of the true as tested collapse value, with the calculated values being typically in excess or even an order of magnitude higher than the tested values. The above claim is supported by a case study performed by the author, which disproves most of what was previously understood to be true. This paper also aims to explore the various failure mechanisms of different configurations of filter core, comparing calculated collapse values against real tested values, with a view to understanding a method of calculating their true collapse value. As the technology is advancing, and filter elements are being used in higher temperature, higher pressure, more radioactive and more chemically aggressive environments, confidence in core collapse values and data is crucial. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design Description of the X-33 Avionics Architecture

In this paper, we provide a design description of the X-33 avionics architecture. The X-33 is an autonomous Single Stage to Orbit (SSTO) launch vehicle currently being developed by Lockheed Martin for NASA as a technology demonstrator for the VentureStar Reusable Launch Vehicle (RLV). The X-33 avionics provides autonomous control of die vehicle throughout takeoff, ascent, descent, approach, landing, rollout, and vehicle safing. During flight the avionics provides communication to the range through uplinked commands and downlinked telemetry. During pre-launch and post-safing activities, the avionics provides interfaces to ground support consoles that perform vehicle flight preparations and maintenance. The X-33 Avionics is a hybrid of centralized and distributed processing elements connected by three dual redundant Mil-Std 1553 data buses. These data buses are controlled by a central processing suite located in the avionics bay and composed of triplex redundant Vehicle Mission Computers (VMCs). The VMCs integrate mission management, guidance, navigation, flight control, subsystem control and redundancy management functions. The vehicle sensors, effectors and subsystems are interfaced directly to the centralized VMCs as remote terminals or through dual redundant Data Interface Units (DIUs). The DIUs are located forward and aft of the avionics bay and provide signal conditioning, health monitoring, low level subsystem control and data interface functions. Each VMC is connected to all three redundant 1553 data buses for monitoring and provides a complete identical data set to the processing algorithms. This enables bus faults to be detected and reconfigured through a voted bus control configuration. Data is also shared between VMCs though a cross channel data link that is implemented in hardware and controlled by AlliedSignal's Fault Tolerant Executive (FTE). The FTE synchronizes processors within the VMC and synchronizes redundant VMCs to each other. The FTE provides an output-voting plane to detect, isolate and contain faults due to internal hardware or software faults and reconfigures the VMCs to accommodate these faults. Critical data in the 1553 messages are scheduled and synchronized to specific processing frames in order to minimize data latency. In order to achieve an open architecture, military and commercial off-the-shelf equipment is incorporated using common processors, standard VME backplanes and chassis, the VxWorks operating system, and MartixX for automatic code generation. The use of off-the-shelf tools and equipment helps reduce development time and enables software reuse. The open architecture allows for technology insertion, while the distributed modular elements allow for expansion to increased redundancy levels to meet the higher reliability goals of future RLVs.

Reichenfeld, Curtis J.↗

Height Above Nearest Drainage (HAND) and Hydraulic Property Table for CONUS - Version 0.21 (20200601)

The continental flood inundation mapping (CFIM) framework is a high-performance computing (HPC)-based computational framework for the Height Above Nearest Drainage (HAND)-based inundation mapping methodology. Using the 10m Digital Elevation Model (DEM) data produced by U.S. Geological Survey (USGS) 3DEP (the 3-D Elevation Program) and the NHDPlus hydrography dataset produced by USGS and the U.S. Environmental Protection Agency (EPA), a hydrological terrain raster called HAND is computed for HUC6 units in the conterminous U.S. (CONUS). The value of each raster cell in HAND is an approximation of the relative elevation between the cell and its nearest water stream. Derived from HAND, a hydraulic property table is established to calculate river geometry properties for each of the 2.7 million river reaches covered by NHDPlus (5.5 million kilometers in total length). This table is a lookup table for water depth given an input stream flow value. Such lookup is available between water depth 0m and 25m at 1-foot interval. The flood inundation map is then computed by using HAND and this lookup table based on the near real-time water forecast from the National Water Model (NWM) at the National Oceanic and Atmospheric Administration (NOAA). HAND and the Hydraulic Property Table version v0.21 is an upgrade to v0.2. Version 0.21 applies NHD HR etching to DEMs for all HUC6 units before running the HAND workflow. This new version also fixed the issue of void areas along HUC boundary. This dataset comprises 331 HUC6 units for CONUS (excluding the five great lakes units), each is a downloadable zip file. Version 0.1 was computed at the National Center for Supercomputing Applications (NCSA) at the University of Illinois at Urban-Champaign in 2016 and is currently hosted at the Texas Advanced Computing Center (TACC). Please cite this data DOI and the following publications and data DOIs when you use HAND and the hydraulic property table: Liu, Yan Y. Height Above Nearest Drainage (HAND) and Hydraulic Property Table for CONUS - Version 0.2. (20200301). Oak Ridge Leadership Computing Facility. (2020). DOI: 10.13139/ORNLNCCS/1608331 Liu, Yan Y., David R. Maidment, David G. Tarboton, Xing Zheng, and Shaowen Wang. 'A CyberGIS integration and computation framework for high-resolution continental-scale flood inundation mapping.' JAWRA Journal of the American Water Resources Association 54, no. 4 (2018): 770-784. DOI: 10.1111/1752-1688.12660 Zheng, Xing, David G. Tarboton, David R. Maidment, Yan Y. Liu, and Paola Passalacqua. 'River channel geometry and rating curve estimation using height above the nearest drainage.' JAWRA Journal of the American Water Resources Association 54, no. 4 (2018): 785-806. DOI: 10.1111/1752-1688.12661 Liu, Y. (2018). Height Above Nearest Drainage (HAND) for CONUS, HydroShare, https://doi.org/10.4211/hs.69f7d237675c4c73938481904358c789 LICENSE FOR USE -- MAPS AND DATA DISCLAIMER This resource is shared under the Creative Commons Attribution CC BY, http://creativecommons.org/licenses/by/4.0/ MAPS AND DATA DISCLAIMER The Oak Ridge National Laboratory (ORNL) shall not be held liable for improper or incorrect use of the data described or information contained on this map or associated series of maps. The data and related map graphics are not legal, land survey or engineering documents and are not intended to be used as such. ORNL gives no warranty, express or implied, as to the accuracy, reliability, utility or completeness of this information. The user of these maps and data assumes all responsibility and risk for the use of the maps and data. ORNL disclaims all warranties, representations or endorsements either express or implied, with regard to the information contained in this map product, including, but not limited to, all implied warranties of merchantability, fitness for a particular purpose or non-infringement. This preliminary map product is for research and review purposes only. It is not intended to be used for emergency management operational or life safety decisions at the local or regional governmental level or by the general public. Users requiring information regarding hazardous conditions or meteorological conditions for specific geographic areas should consult directly with their city or county emergency management office.

54 ENVIRONMENTAL SCIENCES↗

Integrated Systems Health Management for Space Exploration

Integrated Systems Health Management (ISHM) is a system engineering discipline that addresses the design, development, operation, and lifecycle management of components, subsystems, vehicles, and other operational systems with the purpose of maintaining nominal system behavior and function and assuring mission safety and effectiveness under off-nominal conditions. NASA missions are often conducted in extreme, unfamiliar environments of space, using unique experimental spacecraft. In these environments, off-nominal conditions can develop with the potential to rapidly escalate into mission- or life-threatening situations. Further, the high visibility of NASA missions means they are always characterized by extraordinary attention to safety. ISHM is a critical element of risk mitigation, mission safety, and mission assurance for exploration. ISHM enables: In-space maintenance and repair; a) Autonomous (and automated) launch abort and crew escape capability; b) Efficient testing and checkout of ground and flight systems; c) Monitoring and trending of ground and flight system operations and performance; d) Enhanced situational awareness and control for ground personnel and crew; e) Vehicle autonomy (self-sufficiency) in responding to off-nominal conditions during long-duration and distant exploration missions; f) In-space maintenance and repair; and g) Efficient ground processing of reusable systems. ISHM concepts and technologies may be applied to any complex engineered system such as transportation systems, orbital or planetary habitats, observatories, command and control systems, life support systems, safety-critical software, and even the health of flight crews. As an overarching design and operational principle implemented at the system-of-systems level, ISHM holds substantial promise in terms of affordability, safety, reliability, and effectiveness of space exploration missions.

Uckun, Serdar↗

Reducing Thermal Degradation of Perovskite Solar Cells during Vacuum Lamination by Internal Diffusion Barriers

Current photovoltaic (PV) panels typically contain interconnected solar cells that are vacuum laminated with a polymer encapsulant between two pieces of glass or glass with a polymer backsheet. This packaging approach is ubiquitous in conventional photovoltaic technologies such as silicon and thinfilm solar modules, contributing to thermal management, mechanical reinforcement, and environmental protection to enable the long lifetimes necessary to become financially acceptable. Commercial vacuum lamination processes typically occur at 150 °C to ensure cross-linking and/or glass bonding of the encapsulant to the glass and PV cells. Perovskite solar cells (PSCs) have emerged as a promising next-generation PV technology that is known to degrade under thermal stresses, especially at temperatures above 100 °C. In this study, we determine degradation modes during lamination and engineer internal diffusion barriers within the PSC to withstand the harsh thermal conditions of vacuum lamination. PSCs with self-assembled monolayers at the ITO interface and SnO X layers deposited by atomic layer deposition at the electron extraction side of the device endured vacuum lamination at conditions typical of commercial PV processes (150 °C) without degradation. This work demonstrates that perovskite PV can be integrated into the existing module lamination process, enabling future single- and multijunction modules utilizing perovskite absorbers.

14 SOLAR ENERGY↗

Height Above Nearest Drainage (HAND) and Hydraulic Property Table for CONUS

The continental flood inundation mapping (CFIM) framework is a high-performance computing (HPC)-based computational framework for the Height Above Nearest Drainage (HAND)-based inundation mapping methodology. Using the 10m Digital Elevation Model (DEM) data produced by U.S. Geological Survey (USGS) 3DEP (the 3-D Elevation Program) and the NHDPlus hydrography dataset produced by USGS and the U.S. Environmental Protection Agency (EPA), a hydrological terrain raster called HAND is computed for HUC6 units in the conterminous U.S. (CONUS). The value of each raster cell in HAND is an approximation of the relative elevation between the cell and its nearest water stream. Derived from HAND, a hydraulic property table is established to calculate river geometry properties for each of the 2.7 million river reaches covered by NHDPlus (5.5 million kilometers in total length). This table is a lookup table for water depth given an input stream flow value. Such lookup is available between water depth 0m and 25m at 1-foot interval. The flood inundation map is then computed by using HAND and this lookup table based on the near real-time water forecast from the National Water Model (NWM) at the National Oceanic and Atmospheric Administration (NOAA). HAND and the Hydraulic Property Table version 0.2. is created to correspond to data updates in the USGS 1/3 arcsec DEM, the USGS National Hydrography Dataset, including its Water Boundary Dataset, and the NHDPlus medium resolution dataset. This dataset comprises 331 HUC6 units for CONUS (excluding the five great lakes units), each is a downloadable zip file. Version 0.1 was computed at the National Center for Supercomputing Applications (NCSA) at the University of Illinois at Urban-Champaign in 2016 and is currently hosted at the Texas Advanced Computing Center (TACC). Please cite this data DOI and the following publications and data DOIs when you use HAND and the hydraulic property table: Liu, Yan Y., David R. Maidment, David G. Tarboton, Xing Zheng, and Shaowen Wang. 'A CyberGIS integration and computation framework for high-resolution continental-scale flood inundation mapping.' JAWRA Journal of the American Water Resources Association 54, no. 4 (2018): 770-784. DOI: 10.1111/1752-1688.12660 Zheng, Xing, David G. Tarboton, David R. Maidment, Yan Y. Liu, and Paola Passalacqua. 'River channel geometry and rating curve estimation using height above the nearest drainage.' JAWRA Journal of the American Water Resources Association 54, no. 4 (2018): 785-806. DOI: 10.1111/1752-1688.12661 Liu, Y. (2018). Height Above Nearest Drainage (HAND) for CONUS - v0.1, HydroShare, https://doi.org/10.4211/hs.69f7d237675c4c73938481904358c789 LICENSE FOR USE -- MAPS AND DATA DISCLAIMER This resource is shared under the Creative Commons Attribution CC BY, http://creativecommons.org/licenses/by/4.0/ MAPS AND DATA DISCLAIMER The Oak Ridge National Laboratory (ORNL) shall not be held liable for improper or incorrect use of the data described or information contained on this map or associated series of maps. The data and related map graphics are not legal, land survey or engineering documents and are not intended to be used as such. ORNL gives no warranty, express or implied, as to the accuracy, reliability, utility or completeness of this information. The user of these maps and data assumes all responsibility and risk for the use of the maps and data. ORNL disclaims all warranties, representations or endorsements either express or implied, with regard to the information contained in this map product, including, but not limited to, all implied warranties of merchantability, fitness for a particular purpose or non-infringement. This preliminary map product is for research and review purposes only. It is not intended to be used for emergency management operational or life safety decisions at the local or regional governmental level or by the general public. Users requiring information regarding hazardous conditions or meteorological conditions for specific geographic areas should consult directly with their city or county emergency management office.

54 ENVIRONMENTAL SCIENCES↗

Indoor Occupant Counting by RF Backscattering

Building HVAC (heating, ventilation and air conditioning) consumes approximately 13% of all energy consumption in USA. Motion detectors, cameras and user programmable thermostats have been shown to be ineffective for HVAC controls to save energy, mostly due to the user concerns of comfort, reliability and privacy. A new HVAC control system based on real-time occupant counting that is fully automated, highly accurate, economically sensible and preserving privacy and aesthetics can thus bring forth a disruptive impact to this large energy sector. Our indoor occupant monitoring technology is based on the radio-frequency identification system (RFID), deployed in the room, not on the occupants. One reader with four antennas can be deployed on the ceiling or behind the ceiling panels for every thousand square feet in home, office and assisted living, with or without room partitions. The sticker-like passive tag, 10 cents each and maintenance-free, are profusely hidden on the wall or inside the furniture at arbitrary position, preserving privacy and aesthetics. The large number of tags can realize diverse observation points to accommodate arbitrary room layouts, which is impractical by other active units of camera, infrared, radar or lidar. With 20 tags, the system can reliably detect the number of occupants. For 100 tags, occupant posture and location can be known. The technology has been verified in the research labs and test buildings with very high accuracy. When the real-time occupant number can be accurately known without assuming devices on occupants or occupant motion, the building HVAC system can be automated to achieve building energy saving without sacrificing occupant comfort. According to our limited testing in a few types of building models and the simplified cost calculation, the RFID system has low overall cost in production, deployment, operation and maintenance. The signal processing algorithm based on machine learning requires very small number of training cases as most learning is transferrable for various layouts, and very low computational needs during operation, according to our testing in four different room sizes and layouts. In our preliminary estimate from HVAC saving alone, the RFID system can potentially pay for itself within 1.5 years, in addition to the other enhancement in building automation systems (BAS). Our commercialization strategy and business pitch deck focus on venturing this Cornell occupant monitoring technology into BAS and energy management markets. We have identified three broad BAS market segments of senior living, residential buildings, and office buildings. We have put together the minimum viable product characteristics for these identified segments, including analyses on total cost and competing technologies, as well as the fit and technical gaps for these market segments. We intend to bring the technology to market by licensing or partnering with existing BAS vendors. A list of potential collaborators and licensing partner candidates was assembled for different aspects of integrating our technology into a potential product that can be used with BAS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Validation Approach for an Integrated Waste Glass Melter Model

Integrated models are being developed to represent the physics occurring within the high-level and low-activity waste melters that will be used to vitrify legacy tank waste at the Hanford site. These models couple the melt pool, cold cap, and plenum region within a single computational domain. Validation of the models is essential to ensure the reliability of the numerical predictions of the operational melters. Experimental data from laboratory- and pilot-scale tests are thus being used to inform and validate various aspects of the melter model. This study presents a tiered approach to model validation consisting of a series of progressively more complex test cases designed to model the physics occurring in the full-scale system. A hierarchical methodology has been developed to segregate and simplify the physical phenomena affecting the multiphase flow and heat transfer within a waste glass melter. Finally, four hierarchical levels are defined in a validation pyramid and built up in levels of increasing complexity from unit problems to subsystem cases, to pilot-scale systems, and then to the full-scale system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exe-Guard Project

The exe-Guard Project is an alliance between Dominion Virginia Power (DVP), Sandia National Laboratories (SNL), Dartmouth University, and Schweitzer Engineering Laboratories (SEL). SEL is primary recipient on this project. The exe-Guard project was selected for award under DE-FOA-0000359 with CFDA number 81.122 to address Topic Area of Interest 4: Hardened platforms and Systems. The exe-Guard project developed an antivirus solution for control system embedded devices to prevent the execution of unauthorized code and maintain settings and configuration integrity. This project created a white list antivirus solution for control systems capable of running on embedded Linux® operating systems. White list antivirus methods allow only credible programs to run through the use of digital signatures and hash functions. Once a system’s secure state is baselined, white list antivirus software denies deviations from that state because of the installation of malicious code as this changes hash results. Black list antivirus software has been effective in traditional IT environments but has negative implications for control systems. Black list antivirus uses pattern matching and behavioral analysis to identify system threats while relying on regular updates to the signature file and recurrent system scanning. Black list antivirus is vulnerable to zero day exploits which have not yet been incorporated into a signature file update. System scans hamper the performance of high availability applications, as revealed in NIST special publication 1058 which summarizes the impact of blacklist antivirus on control systems: Manual or “on-demand” scanning has a major effect on control processes in that they take CPU time needed by the control process (Sometimes close to 100% of CPU time). Minimizing the antivirus software throttle setting will reduce but not eliminate this effect. Signature updates can also take up to 100% of CPU time, but for a much shorter period than a typical manual scanning process. Control systems are vulnerable to performance losses if off-the-shelf blacklist antivirus solutions aren’t implemented with care. This investment in configuration in addition to constant decommissioning to perform manual signature file updates is unprecedented and impractical. Additionally, control systems are often disconnected or islanded from the network making the delivery of signature updates difficult. Exe-Guard project developed a white list antivirus solution that mitigated the above drawbacks and allows control systems to cost-effectively apply malware protection while maintaining high reliability. The application of security patches can also be minimized since white listing maintains constant defense against unauthorized code execution. Security patches can instead be applied in less frequent intervals where system decommissioning can be scheduled and planned for. Since control systems are less dynamic than IT environments, the feasibility of maintaining a secure baselined state is more practical. Because upgrades are performed in infrequent, calculated intervals, it allows a new security baseline to be established before the system is returned to service. Exe-Guard built on the efforts of SNL under the Code Seal project. SNL demonstrated prototype Trust Anchors on the project which are independent monitoring and control devices that can be integrated into untrustworthy components. The exe-Guard team started with the lessons learned under this project then designed commercial solution for white list malware protection. Malware is a real threat, even on islanded or un-networked installations, since operators can unintentionally install infected files, plug in infected mass storage devices, or infect a piece of equipment on the islanded local area network that can then spread to other connected equipment. Protection at the device level is one of the last layers of defense in a security-in-depth defense model before an asset becomes compromised. This project provided non-destructive intrusion, isolation and automated response solution, achieving a goal of the Department of Energy (DOE) Roadmap to Secure Control Systems. It also addressed CIP-007-R4 which requires asset owners to employ malicious software prevention tools on assets within the electronic security perimeter. In addition, the CIP-007-R3 requirement for security patch management is minimized because white listing narrows the impact of vulnerabilities and patch releases. The exe-Guard Project completed all tasks identified in the statement of project objective and identified additional tasks within scope that were performed and completed within the original budget. The cost share was met and all deliverables were successfully completed and submitted on time. Most importantly the technology developed and commercialized under this project has been adopted by the Energy sector and thousands of devices with exe-Guard technology integrated in them have now been deployed and are protecting our power systems today

24 POWER TRANSMISSION AND DISTRIBUTION↗

Igiugig Site Visit Report

The National Renewable Energy Laboratory (NREL) team conducted a site visit during January 23-25, 2019 with the Igiugig Village Council (IVC) and other stakeholders to assist the community of Igiugig in refining their long-term energy strategy. The agenda included a tour of the village, data collection, presentations, long-term visioning exercises, identification of energy scenarios, and a school presentation. Participants in the site visit activities spanned a range of local, regional, government, and industry participation. There were 24 attendees at the all-day community workshop on Thursday, January 24th, with participants from the IVC, NREL, Bristol Bay Native Association (BBNA), Bristol Bay Native Corporation (BBNC), Lake and Peninsula Borough, Alaska Energy Authority, Intergrid, ORPC, Deer Stone Consulting, the Southwest Alaska Municipal Conference, and University of Alaska Fairbanks - Alaska Center for Energy and Power. Igiugig is a well-organized rural Alaskan community, with a leadership team that appears to have broad community support. The use of consensus-based decision making is one tangible example of how the leadership team actively invokes and promotes community-focused thinking. The NREL team observed anecdotal evidence of how this approach seems to be strengthening the community: active participation in the visioning exercise, a student hosted fund-raiser dinner at the school, a clean and organized landfill, and well-maintained roads and buildings. Igiugig has wind, solar, and river hydrokinetic resources readily available within the community. Wind has shown to be a promising resource in the region, and has been integrated into microgrids around the state, but the community has had mixed success with wind technologies: some devices failed quickly and others continue to operate. The economics of solar energy are improving in Alaska, and economical solar projects are being installed around the state. Considering that economic activity in Igiugig peaks during the summer sport fishing season, solar could prove to be a valuable supplement to the electrical system. Igiugig has been a test site for two different river hydrokinetic devices, and they have began a third project to operate ORPC's RivGen device, which is delivering valuable device performance data, operations and maintenance experience, and design refinement information. Already, this device has made over 7-million revolutions, and delivered over 8 MWh of power to the community. Igiugig's river resource is fairly unique because it is available year-round and has the potential to provide reliable base-load power for months at a time. A preliminary investigation of this diverse resource mix suggests that Igiugig could achieve very high levels (70% or more) of annual renewable generation contributions. A critical step in pursuing this path is identifying the mix of energy assets (generation and storage) that best meets the community's budget, needs, and goals. The assets that a community installs early in their grid-modernization initiative can constrain the options that are economical at later stages, which may lead to sub-optimal solutions. This is where technical and economic analysis of potential scenarios (i.e., distinct mixes of energy assets) can be useful in identifying the most promising pathways so that a community can make informed and strategic decisions about the assets they install. These analyses are most accurate and informative when they are based on actual technology performance and cost data. As the RivGen project continues to operate and generate this data, we will be better prepared to evaluate the technology's long-term viability and to identify research areas that would improve it. Igiugig's energy projects are at the cutting edge of two intersecting technology areas: 1) deploying an operational river hydrokinetic turbine, and 2) integrating renewable energy sources to achieve very high percent renewables. If these projects are successful, the lessons learned and technologies developed could be valuable for other microgrids around the world. Igiugig's unique resource mix make it an ideal location for this work, and the community's organizational strength make it an ideal partner in this ground-breaking work. Ongoing support for technical assistance to manage and address technical challenges along the way will maximize the probability of project success.

13 HYDRO ENERGY↗

RANGERS: Methodology for Design and Performance Assessment of Engineered Barrier Systems in a Salt Repository for HLW/SNF: Synthesis Report

Salt formations have long been recognized as a highly favorable host rock for the final disposal of high-level radioactive waste (HLW) in deep geological repositories. Their unique properties, including exceptional impermeability, self-healing capabilities, and thermal conductivity, make them a reliable natural barrier for the deep disposal of radioactive waste. This report focuses on the development and application of a methodology for assessing the integrity and per formance of the Engineered Barrier System (EBS) within salt-based repositories, a critical component of the multi-barrier system ensuring safe radioactive waste disposal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interconnection Assessment Methodology and Cost Benefit Analysis for High-Penetration PV Deployment in the Arizona Public Service System

In an effort to better understand the impacts of high penetrations of photovoltaic (PV) generators on distribution systems, Arizona Public Service and its partners completed a multi-year project to develop the tools and knowledge base needed to safely and reliably integrate high penetrations of utility- and residential-scale PV. Building upon the APS Community Power Project-Flagstaff Pilot, this project investigates the impact of PV on a representative feeder in northeast Flagstaff. To quantify and catalog the effects of the estimated 1.3 MW of PV that will be installed on the feeder (both smaller units at homes and large, centrally located systems), high-speed weather and electrical data acquisition systems and digital 'smart' meters were designed and installed to facilitate monitoring and to build and validate comprehensive, high-resolution models of the distribution system. These models are being developed to analyze the impacts of PV on distribution circuit protection systems (including coordination and anti-islanding), predict voltage regulation and phase balance issues, and develop volt/VAr control schemes. This paper continues from a paper presented at the 2014 IEEE PVSC conference that described feeder model evaluation and high penetration advanced scenario analysis, specifically feeder reconfiguration. This paper presents results from Phase 5 of the project. Specifically, the paper discusses tool automation; interconnection assessment methodology and cost benefit analysis.

14 SOLAR ENERGY↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Achieving Economy-wide Net-Zero Solutions: The Essential Role of Nuclear Energy

The Biden administration has committed to full decarbonization of the U.S. electricity grid by 2035 and economy-wide net zero emissions by 2050. These aggressive goals demand immediate action if we are to be successful, and they require us to think more holistically about our clean energy options. Programs within the Department of Energy are addressing these holistic solutions. Traditionally, electricity generation and management and meeting energy demands for industry and transportation are considered independently. As we seek to achieve net zero, we need to reassess our energy demands. When we consider overall energy use, only one-third is in the form of electricity. Additional energy demands are in the form of heat or steam for industrial processes, as well as transportation. These sectors are much harder to abate, and electrification may not be the best option. Reducing environmental emissions at an affordable cost, while maintaining grid reliability and resilience, will require us to use all of the clean energy resources that we have available. That means coordinating the use of nuclear, renewables, and fossil fuels with carbon capture to meet growing demands for electricity, industrial applications, and mobility. Various energy applications and product streams beyond electricity are being evaluated, ranging from generation of potable water to production of hydrogen, fertilizers, synthetic fuels, and various chemicals. This presentation will highlight advanced nuclear technologies under development today and will provide a glimpse into the wide array of R&D being conducted across multiple DOE-funded programs.

08 HYDROGEN↗

State Performance-Based Regulation Using Multiyear Rate Plans for U.S. Electric Utilities

Electric utilities today must contain costs at a time when many need to modernize aging systems and all face major changes in technologies, customer preferences and competitive pressures.Most U.S. electric utility facilities are investor-owned, subject to rate and service regulation by state public utility commissions. Regulatory systems under which these utilities operate affect their performance and ability to meet these challenges. In this business environment, multiyear rate plans have some advantages over traditional rate regulation.The report focuses on key design issues and provides case studies of the multiyear rate plan approach, applicable to both vertically integrated and restructured states. Mark Newton Lowry and Matt Makos of Pacific Energy Group Research and Jeff Deason of Berkeley Lab authored the report; Lisa Schwartz, Berkeley Lab, was project manager and technical editor.The report is aimed primarily at state utility regulators and stakeholders in the state regulatory process. The multiyear rate approach also provides ideas on how to streamline oversight of public power utilities and rural electric cooperatives for their governing boards.Two key provisions of multiyear rate plans strengthen cost containment incentives and streamline regulation: 1. Reducing frequency of rate cases, typically to every four or five years 2. Using an attrition relief mechanism to escalate rates or revenue between rate cases to address cost pressures such as inflation and growth in number of customers, independently of the utility’s own cost Better utility performance can be achieved under well-designed multiyear rate plans while achieving lower regulatory costs. Benefits can be shared between utilities and their customers. But plans can be complex and involve significant changes in the regulatory system. Designing plans that stimulate utility performance without undue risk and share benefits fairly can be challenging.This report discusses the rationale for multiyear rate plans and their usefulness under modern business conditions. It then explains critical plan design issues and challenges and presents results from numerical research that considers the extra incentive power achieved under different plan provisions. Next, the report presents several case studies of utilities that have operated under formal multiyear rate plans or, for various reasons, have stayed out of rate cases for more than a decade. These studies consider the effect of multiyear rate plans and rate case frequency on utility cost, reliability and other performance dimensions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗