Search NASA⌕ Search

SEARCH · Search NASA

Results for “Resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Edge magnetoplasmon dispersion and time-resolved plasmon transport in a quantum anomalous Hall insulator

A quantum anomalous Hall (QAH) insulator breaks reciprocity by combining magnetic polarization and spin-orbit coupling to generate a unidirectional transmission of signals in the absence of an external magnetic field. Such behavior makes QAH materials a good platform for the innovation of circulator technologies. However, it remains elusive as to how the wavelength of the chiral edge plasmon relates to its frequency and how the plasmon wave packet is excited in the time domain in a QAH insulator. Here, we investigate the edge magnetoplasmon (EMP) resonances in Cr-(Bi,Sb) 2 Te 3 by frequency and time domain measurements. From disk shaped samples with various dimensions, we obtain the dispersion relation of EMPs and extract the drift velocity of the chiral edge state. From the time-resolved transport measurements, we identify the velocity of the plasmon wave packet and observe a transition from the edge to bulk transport at an elevated temperature. We show that the frequency and time domain measurements are well modeled by loss from the microwave induced dissipative channels in the bulk area. Our results demonstrate that the EMP decay rate can be significantly reduced by applying a low microwave power and fabricating devices of larger diameter ≥ 100 µ m . In a R = 125 µ m sample, a nonreciprocity of 20 dB has been realized at 1.3 GHz, shining light on using QAH insulators to develop on-chip nonreciprocal devices. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hybridized kagome bands and induced Ti magnetism in RTi3Bi4 (R = Nd, Sm, Gd) kagome metals studied using angle-resolved photoemission spectroscopy and x-ray magnetic circular dichroism

Kagome materials are known for hosting emergent quantum phenomena driven by the interaction between different lattice, charge and spin orders. Here, we present a detailed angle resolved photoemission (ARPES), density functional theory (DFT) and x-ray magnetic circular dichroism (XMCD) study of the electronic and magnetic structure of RTi3Bi4 (R = Nd, Sm, Gd). ARPES and DFT demonstrate that the bulk electronic band structure is dominated by the hybridization of the Ti bands, and the weak electron-like pocket at Γ is identified as a surface state. The isotropic XAS profile of the M 4,5-edge of the rare earth is consistent with the presence of R 3+ oxidation state. Using the XMCD sum rules, backed by the atomic multiplet theory calculations, we obtain the spin and orbital magnetic moments. The Ti L2,3-edge XMCD reveals the presence of a small magnetic moment in GdTi3Bi4, presumably driven by the proximity of the Ti kagome layers to the zigzag chains of Gd, while the total magnetic moment of Gd is shared by the f and d electrons. Our combined XMCD, ARPES and DFT study brings an important piece of information to understand the spin flip transitions and anomalous Hall effect observed in the RTi3Bi4 kagome metals.

Lim, C.↗

Angle-resolved photoemission studies of quantum materials

The physics of quantum materials is dictated by many-body interactions and mathematical concepts such as symmetry and topology that have transformed our understanding of matter. Angle-resolved photoemission spectroscopy (ARPES), which directly probes the electronic structure in momentum space, has played a central role in the discovery, characterization, and understanding of quantum materials ranging from strongly correlated states of matter to those exhibiting nontrivial topology. Over the past two decades, ARPES as a technique has matured dramatically with ever-improving resolution and continued expansion into the space, time, and spin domains. Simultaneously, the capability to synthesize new materials and apply nonthermal tuning parameters in situ has unlocked new dimensions in the study of all quantum materials. These developments are reviewed, and the scientific contributions they have enabled in contemporary quantum materials research are surveyed.

36 MATERIALS SCIENCE↗

Search for nonvirialized axions with 3.3 − 4.2 μ ⁢eV mass at selected resolving powers

The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth’s motion. Here, we report an exclusion on the local axion dark matter density in narrow flows of ρ a ≳ 0.03 GeV/cm 3 and ρ a ≳ 0.004 GeV/cm 3 for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range 3.3−4.2 μeV. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Depth-resolved Laue microdiffraction with coded apertures

A rapid data acquisition and reconstruction method is introduced to image the crystalline structure of materials and the associated strain and orientations at micrometre resolution using Laue diffraction. The method relies on scanning a coded aperture across the diffracted X-ray beam from broadband illumination and a reconstruction algorithm to resolve Laue microdiffraction patterns as a function of depth along the incident illumination path. It provides rapid access to full diffraction information for sub-micrometre volume elements in bulk materials. Both the theory and the experimental validation of this imaging approach are presented in this report.

36 MATERIALS SCIENCE↗

Pulse-resolved intensity measurements at a hard X-ray FEL using semi-transparent diamond detectors

Solid-state ionization chambers are presented based on thin diamond crystals that allow pulse-resolved intensity measurements at a hard X-ray free-electron laser (FEL), up to the 4.5 MHz repetition rate that will become available at the European XFEL. Due to the small X-ray absorption of diamond the thin detectors are semi-transparent which eases their use as non-invasive monitoring devices in the beam. FELs are characterized by strong pulse-to-pulse intensity fluctuations due to the self-amplified spontaneous emission (SASE) process and in many experiments it is mandatory to monitor the intensity of each individual pulse. Two diamond detectors with different electrode materials, beryllium and graphite, were tested as intensity monitors at the XCS endstation of the Linac Coherent Light Source (LCLS) using the pink SASE beam at 9 keV. The performance is compared with LCLS standard monitors that detect X-rays backscattered from thin SiN foils placed in the beam. In conclusion, the graphite detector can also be used as a beam position monitor although with rather coarse resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The time-resolved atomic, molecular and optical science instrument at the Linac Coherent Light Source

The newly constructed time-resolved atomic, molecular and optical science instrument (TMO) is configured to take full advantage of both linear accelerators at SLAC National Accelerator Laboratory, the copper accelerator operating at a repetition rate of 120 Hz providing high per-pulse energy as well as the superconducting accelerator operating at a repetition rate of about 1 MHz providing high average intensity. Both accelerators power a soft X-ray free-electron laser with the new variable-gap undulator section. With this flexible light source, TMO supports many experimental techniques not previously available at LCLS and will have two X-ray beam focus spots in line. Thereby, TMO supports atomic, molecular and optical, strong-field and nonlinear science and will also host a designated new dynamic reaction microscope with a sub-micrometer X-ray focus spot. The flexible instrument design is optimized for studying ultrafast electronic and molecular phenomena and can take full advantage of the sub-femtosecond soft X-ray pulse generation program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mixed gain detector configurations for time-resolved X-ray solution scattering

X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structured illumination for surface-resolved grazing-incidence X-ray scattering

Grazing-incidence (GI) scattering techniques are widely used to characterize thin films, offering high surface sensitivity and insight into morphology and structure. However, these approaches typically provide statistical averaged information due to elongated footprint or limited spatial resolution due to beam size. Here we introduce a method that combines structured illumination with GI X-ray scattering and leverages our computational imaging approach to resolve local structural details. We demonstrate that our method captures local features of an organic semiconductor thin film without the need for sample rotation as in tomography. The method expands GI techniques from statistical averaging to high-resolution imaging, thereby providing the capability for detailed analysis of local material properties, such as domain shape, orientation and polymorphism, which are critical for advancing material design towards more efficient and tailored materials.

97 MATHEMATICS AND COMPUTING↗

Resolving 500 nm axial separation by multi-slice X-ray ptychography

Multi-slice X-ray ptychography offers an approach to achieve images with a nanometre-scale resolution from samples with thicknesses larger than the depth of field of the imaging system by modeling a thick sample as a set of thin slices and accounting for the wavefront propagation effects within the specimen. Here, we present an experimental demonstration that resolves two layers of nanostructures separated by 500 nm along the axial direction, with sub-10 nm and sub-20 nm resolutions on two layers, respectively. Fluorescence maps are simultaneously measured in the multi-modality imaging scheme to assist in decoupling the mixture of low-spatial-frequency features across different slices. The enhanced axial sectioning capability using correlative signals obtained from multi-modality measurements demonstrates the great potential of the multi-slice ptychography method for investigating specimens with extended dimensions in 3D with high resolution.

36 MATERIALS SCIENCE↗

Wavelength-resolved Neutron Tomography for Crystalline Materials

Wavelength-resolved (WR) neutron transmission tomography is an emerging technique to characterize engineering materials. While tomographic reconstruction for amorphous samples is straightforward, it is challenging to reconstruct samples with single-crystal domains because the attenuation of the sample varies as a function of its orientation with respect to the incident beam due to Bragg scattering. In this paper, we present an algorithm that can reconstruct samples with single-crystal domains from WR neutron tomographic measurements. In particular, we use a model-based iterative reconstruction (MBIR) technique that reconstructs the volume by identifying and leaving out the regions of the measurement that are affected by Bragg scatter. We combine the output of the MBIR method with an algorithm that matches the reconstruction to the identified Bragg scatter to reconstruct a feature that corresponds to the local crystallography of the sample being measured. Using simulated data, we demonstrate how our algorithm can reconstruct materials with single-crystal domains, thereby adding a powerful new capability for WR neutron imaging instruments.

Singanallur Vaidyanathan, Venkatakrishnan↗

Spatially Resolved Recombination Analysis of CuIn $_\text{x}$ Ga $_\text{1-x}$ Se $_{2}$ Absorbers With Alkali Postdeposition Treatments

In this contribution, we probe spatial variations in charge-carrier recombination in CuIn x Ga 1-x Se 2 (CIGS) absorbers grown on soda-lime glass (SLG) and alkali-free sapphire substrates with NaF and KF postdeposition treatments (PDTs). Temperature-and illumination-dependent device measurements are used to track interface recombination and recombination in the quasi-neutral region. The analysis of these data reveals that the benefit of alkali PDTs depends on the substrate: interface recombination is reduced in devices grown on sapphire substrates, whereas recombination in the quasi-neutral regions is reduced in devices grown on SLG substrates. Cathodoluminescence (CL) spectrum imaging is used to study the spatial distribution of recombination with respect to the grain structure. The grain-boundary CL contrast is similar in films with no PDT, NaF PDT, or KF PDT. A reduced grain-boundary contrast is observed with a NaF + KF PDT; however, suggesting a reduced recombination strength at the grain boundaries (GBs) for combined NaF + KF treatment. CL spectra indicate band tailing, consistent with the fluctuating potential model. Fluctuating potentials are believed to reduce open-circuit voltage, but their spatial distribution has not been studied. Here, CL spectrum imaging data are used to generate maps of the root-mean-square value of the potential energy fluctuations-γ. These maps reveal a bimodal ..gamma.. distribution for all samples: ..gamma.. is generally in the range ~15-50 meV or ~100-180 meV. The higher ..gamma.. range is more significantly affected by the PDTs; after the PDTs, it is strongly correlated with GBs. The lower ..gamma.. range is correlated with higher emission intensity regions, typically grain interiors, and increases in area fraction after the PDTs. These results demonstrate how spatially resolved luminescence and device characterization measurements can be used to monitor changes in recombination in CIGS films and photovoltaic devices. Such measurements can complement empirical device optimization and help improve device performance.

14 SOLAR ENERGY↗

Employing Weibull Analysis and Weakest Link Theory to Resolve Crystalline Silicon PV Cell Strength Between Bare Cells and Reduced- and Full-Sized Modules

Weibull analysis and weakest link theory are employed to resolve the probability of crystalline silicon PV cell fracture when measured as bare cells and when stressed in reduced- and full-sized modules. Experimental results indicated that the characteristic cell strength is reduced by ~20% once packaged into the laminate of a one-cell module and loaded in four-point flexure (4PF). This experimental observation was shown consistent with a weakest link theory prediction that the strength limiting flaws reside on the surface of the cell's edge. Here, the analysis is ultimately extended to present the equivalent loading of four-cell modules by uniform pressure and 4PF and a uniformly loaded full-sized module and demonstrates that smaller, representative, modules must be loaded to a much higher level than their parent full-sized modules to achieve an equivalent probability for cell fracture.

14 SOLAR ENERGY↗

Dual-Wavelength Time-Resolved Photoluminescence Study of CdSe x Te 1-x Surface Passivation via Mg y Zn 1-y O and Al 2 O 3

Voltage loss is currently one of the biggest challenges facing cadmium telluride (CdTe) based photovoltaics. Determining the location(s) of major voltage loss within the device stack (e.g., front/back interface, grain boundaries) is therefore of primary interest. Here, we present a custom-built time-resolved photoluminescence system with two excitation wavelengths - 670 (standard) and 405 nm - to probe the device stack at depths of approximately 130 and 35 nm, respectively; their comparison helps differentiate interface and bulk contributions to carrier lifetime. We apply this system to examine the passivation effect of two significant recent advances in CdTe: the incorporation of Se to form graded CdSe x Te 1-x and the replacement of CdS with Mg y Zn 1-y O. It is found that x = 0.2 Se is required to obtain lifetime improvements, primarily in the bulk. Additionally, evidence for trapping at the Mg y Zn 1-y O/CdSe x Te 1-x interface was observed. Furthermore, this indicates further work is required to sufficiently passivate the front interface.

CdSeTe↗

Time-Resolved Measurements of Cygnus X-ray Production Using Aerogel Cherenkov Detector

Aerogel Cherenkov Detector for Cygnus (ACD/C) has been developed to provide time-dependent x-ray spectral information from Cygnus – an intense flash x-ray source operated at the Nevada National Security Site. Time-resolved Cygnus x-ray signals were measured at three energy thresholds: 1.3 MeV (by 197 mg/cc aerogel), 1.1 MeV (by 260 mg/cc aerogel), and 0.3 MeV (by quartz). ACD/C data qualitatively suggest that the high-energy x-ray peak exists on a shorter timescale than the Cygnus voltage or current pulse. A time-dependent, x-ray spectral information can improve the understanding of the physics of dense objects radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlative Characterization of Dislocation Defects and Defect Clusters in GaAs and CdTe Solar Cells by Spatially Resolved Optical Techniques and High-Resolution TEM

An array of correlative and spatially-resolved techniques, including electroluminescence, photoluminescence, Raman, I-V curve, and high-resolution TEM, have been performed on both GaAs and CdTe solar cells, to study the impact of individual dislocation defects and defect clusters on device performance, the dependence of the impact on the device operation conditions, and the microscopic structures of the defects. This approach offers quantitative and definitive correlation between the atomistic structure of a defect and its effects in a real device.

14 SOLAR ENERGY↗

Numerical Analysis of Time Resolved Photoluminescence for Alumina/Cd(Se,Te) Double Heterostructures

Al2O3 has demonstrated excellent Cd(Se,Te) surface passivation. In this work, recombination mechanisms were investigated by comparing simulations of time resolved photoluminescence (TRPL) to PL decay data (320 ns effective lifetime) for Al2O3 /Cd(Se,Te)/Al2O3 double heterostructures. Models were employed to investigate the effects of bulk and surface recombination, electric fields, mobility, and doping by simulating intensity-dependent single- (1PE) and two-photon excitation (2PE) TRPL. 2PE simulations replicate decay behavior while 1PE simulations require attention to charge redistribution. Various coupled mechanisms cannot be distinguished from PL decay data alone. Complementary measurements are required to constrain the model parameters and isolate mechanisms.

CdTe↗

Vector-Resolved Magnetooptic Kerr Effect Measurements of Spin–Orbit Torque

We demonstrate simultaneous detection of current-driven dampinglike and fieldlike spin-orbit torques in heavy metal/ferromagnetic metal bilayers by measuring all three magnetization components m x , m y and m z using a vector-resolved magnetooptic Kerr effect (MOKE) technique based on quadrant detection. Here, we investigate the magnitude and direction of spin-orbit torques in a series of platinum/permalloy samples, finding good agreement with results obtained via polar and quadratic MOKE measurements without quadrant detection

47 OTHER INSTRUMENTATION↗