Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

New Tabu Algorithm for Positioning Mining Drillholes with Blocks Uncertainty

This paper proposes a new approach to the mining exploration drillholes positioning problem (DPP) that incorporates both geostatistical and optimization techniques. A metaheuristic was developed to solve the DPP taking into account an uncertainty index that quantifies the reliability of the current interpretation of the mineral deposit. The uncertainty index was calculated from multiple deposit realizations obtained by truncated Gaussian simulations conditional to the available drillholes samplings. A linear programming model was defined to select the subset of future drillholes that maximizes coverage of the uncertainty. A Tabu Search algorithm was developed to solve large instances of this set partitioning problem. The proposed Tabu Search algorithm is shown to provide good quality solutions approaching 95% of the optimal solution in a reasonable computing time, allowing close to optimal coverage of uncertainty for a fixed investment in drilling.

58 GEOSCIENCES↗

A selection function toolbox for subsets of astronomical catalogues

ABSTRACT Large catalogues are ubiquitous throughout astronomy, but most scientific analyses are carried out on smaller samples selected from these catalogues by chosen cuts on catalogued quantities. The selection function of that scientific sample – the probability that a star in the catalogue will satisfy these cuts and so make it into the sample – is thus unique to each scientific analysis. We have created a general framework that can flexibly estimate the selection function of a sample drawn from a catalogue in terms of position, magnitude and colour. Our method is unique in using the binomial likelihood and accounting for correlations in the selection function across position, magnitude, and colour using Gaussian processes and spherical harmonics. We have created a new open-source python package selectionfunctiontoolbox that implements this framework and used it to make three different estimates of the APOGEE DR16 red giant sample selection function, as a subset of 2MASS, with each estimate using an increasing amount of technical knowledge of the APOGEE targeting. In a companion paper, we applied our methodology to derive estimates of the astrometric and spectroscopic selection functions of Gaia EDR3. Our framework will make it trivial for astrophysicists to estimate the selection function that they should be using with the custom sample of stars that they have chosen to answer their scientific question.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensing and Sampling of Trace Contaminations by a Dexterous Hexrotor UAV at Nuclear Facilities - 18600

Safe and efficient cleanups are a priority for decontamination and decommissioning of nuclear facilities. The contaminations of byproducts and wastes in such nuclear facilities pose a serious problems while decommissioning, to both the operators and public. Sensing these contaminations and cleaning them is an essential part of the safety procedures. The contaminations might range from low-energy to high-energy byproducts. Sensing these byproducts would require contact based or non-contact based sensing, based on its energy levels. Byproducts such as americium, are low-energy which makes it difficult to sense and sample without contact. Therefore, the workers need to physically swab the surfaces to collect the samples of these contaminations. These tasks pose a great danger for the safety of the human workers which includes the risk to reach greater heights, exposure to the radiation and sampling the entire building. A robotic solution is much more desirable in these cases, where the worker can safely handle the contaminations from a safe area. Use of robotic technologies inside these hazardous environments ensures the safety and enhances the performance. The more suitable robotic solution for reaching great heights and covering large areas of nuclear facilities, are aerial vehicles. Multi-rotor unmanned aerial vehicle (UAV) are chosen for their ability to hover at a position and also fly around in confined spaces. Quadrotors are a common choice of multi-rotor UAVs both research and industry because of its ease to fly and commercial availability. For the applications during the cleanups we need the UAV to not only hover and fly in confined spaces, but also interact with the physical world. Despite of quadrotor's advantages, they are not a best suit as they can't interact with the physical world. The tasks involving physical interactions would require the UAV to apply arbitrary forces and torques in all six degrees of freedom (DOF). As quadrotors are under-actuated and non-holonomic in motion, they cannot exert all the required forces. At Collaborative Robotics Lab, Purdue University, we developed a novel multi-rotor UAV solution, Dexterous Hexrotor, which can exert arbitrary forces and torques in all six DOF, independently and instantaneously. This enables the UAV platform to quickly respond to the external disturbances and precisely hold its position during the mission. The Dexterous Hexrotor serves as a robotic tool for the workers to perform sensing and sampling during the cleanups. Workers can operate Dexterous Hexrotor manually and/or semi-autonomously with human intervention. Manual control requires the worker to fly the Dexterous Hexrotor using a remote control. So the workers should possess knowledge on flying the UAV and to perform physical interaction. A semiautonomous Dexterous Hexrotor requires human input to some extent and requires very less knowledge of flying. The autonomy is designed to operate in flight mode and sampling mode. In flight mode, Dexterous Hexrotor takes off from a 'safe' area, reaches the desired altitude, and fly autonomously towards a sampling point. This sampling point is the target position specified on the 2D reference map. This mode also includes navigation towards the sampling point, avoiding the obstacles in the constrained environment. After reaching a stopping point, Dexterous Hexrotor waits for the human input for a target location to swab and collect samples. The Dexterous Hexrotor is now in sampling mode and waits for the human input. The human operator selects the swabbing location through the live streaming video from onboard camera. Through visual servoing, aided by the map, the UAV will move closer towards the target position. It then transitions to the impact control scheme to perform physical interaction with the wall and collects samples. Once the sample is collected, it autonomously returns back to the takeoff position in 'safe' area for the analysis by mass spectrometry. In this paper, we majorly focus on the physical interaction strategy and the required components which enables the autonomy. Decommissioning of nuclear facilities requires decontamination inside the entire buildings. Decontamination of nuclear facilities involves sensing and sampling the huge buildings, long shafts, etc. Sampling the entire facility is not possible due to the limitation in Dexterous Hexrotor's flight time. But this can be achieved by using a swarm of Dexterous Hexrotors to cover larger areas. The onboard robotic arm can be designed based on the applications such as cleaning, applying sealants, etc. The modularity of the design allows us to switch components as per the requirements of the task. These kind of robotic solutions functioning as tools for the workers, aims to make the work environment safer and playful. (authors)

42 ENGINEERING↗

Oxaliplatin and irinotecan induce heterogenous changes in the EMT markers of metastasizing colorectal carcinoma cells

Highlights: • Significant variability and lower expression uniformity in lymph node metastatic cells. • Heterogeneity of cell response partially determined by cancer cell microenvironment. • Metastatic cells proved to be less sensitive to chemotherapy treatment compared to primary site cancer cells. • Irinotecan and oxaliplatin affected EMT markers in primary cell lines. In patients with advanced colorectal cancer (CRC), surgery is complemented with systemic therapy – chemotherapy and radiochemotherapy. Although the patients’ overall survival has been significantly improved, tumor resistance is still a frequent cause of chemotherapy failure. Several factors contribute to chemoresistance of tumor cells including changes related with epithelial-mesenchymal transition (EMT). The present study was designed to verify the presence of EMT markers in paired CRC primary cell lines obtained from primary tumor sites and lymph node metastases of three patients and to investigate the effect of irinotecan and oxaliplatin treatment on these markers as well. The samples of the higher stage of CRC and positive for angioinvasion were selected and qPCR, western blot analysis, migration assay, cytotoxicity testing was performed. Results confirmed the increased expression of several markers characteristic of EMT and invasiveness in lymph node metastatic cells, with a significant variability between individual samples. Irinotecan and oxaliplatin decreased migration activity of the cells and to the varying degree affected the expression of EMT and invasiveness markers. In conclusion, in CRC EMT is present in metastatic cells over a phenotypic continuum whose expression is altered heterogeneously upon irinotecan and oxaliplatin treatment.

60 APPLIED LIFE SCIENCES↗

Acoustic plane waves normally incident on a clamped panel in a rectangular duct

The theory of acoustic plane wave normally incident on a clamped panel in a rectangular duct is developed. The coupling theory between the elastic vibrations of the panel (plate) and the acoustic wave propagation in infinite space and in the rectangular duct is considered. The partial differential equation which governs the vibration of the panel (plate) is modified by adding to its stiffness (spring) forces and damping forces, and the fundamental resonance frequency and the attenuation factor are discussed. The noise reduction expression based on the theory is found to agree well with the corresponding experimental data of a sample aluminum panel in the mass controlled region, the damping controlled region, and the stiffness controlled region. All the frequency positions of the upward and downward resonance spikes in the sample experimental data are identified theoretically as resulting from four cross interacting major resonance phenomena: the cavity resonance, the acoustic resonance, the plate resonance, and the wooden back panel resonance.

Unz, H.↗

Seeking Augmented Information Content Concerning Diurnal Precipitation Achieved by Combining TRMM-PR and CloudSat-CPR Radar Data Sets

The CloudSat satellite's Cloud Profiling Radar (CPR) is a highly sensitive 94 GHz (W-band) nadir viewing radar system flown in retrograde sun synchronous orbit useful for determining the vertical structure of cloud hydrometeors down to sensitivity of approx. -30 dBZ reflectivity factor. Given this sensitivity, it is possible to unambiguously measure precipitation rates in clouds over a spectrum extending from approx. 0.08 - 3.0 mm hr (sup -1) down to altitudes of 0.5 km with approx.0.25 km vertical binning. This enables an effective means to measure a great deal of the drizzle and light rain spectrum. However, because of its near-polar sunsynchronous orbit, CloudSat cannot sample the diurnal cycle of precipitation, nor with its nadir-only CPR view can it obtain a high duty cycle in sampling precipitation at fixed local times over fixed positions. On the other hand, the TRMM satellite, which is flown in a non-sunsynchronous 35-degree inclined orbit carrying the 13.8 GHz KU-band Precipitation Radar (PR) scanning through nadir over an approx. 225 km swath, can sample both the diurnal cycle and with a much improved duty cycle relative to CloudSat. Moreover, the PR and CPR have the same 0.25 km vertical binning capability. The PR's greatest shortcoming is its approx. +17 dBZ sensitivity, which eliminates the possibility of measuring rain rates below -0.3-0.5 mm hr(sup -1), which can involve rainfall accumulations of up to 50% of the total over some regions. This begs the question of whether by combining CPR and PR data sets, whether it is possible to obtain an augmented measurement of the diurnal precipitation cycle. By collecting complimentary datasets during CloudSat and TRMM satellite orbit crossings within a delta t = 45-min proximity window, it is possible to demonstrate that whenever TRMM detects a precipitation signal, the correlations along the vertical axis between the reflectivities acquired from the CPR and PR are in inverse proportion to the magnitude of the delta t proximity window. By taking advantage of these underlying correlations, it is possible to develop a functional which can be used to broaden the reflectivity spectrum, concomitantly the rain rate spectrum, of the PR measurements based on the inherently broader reflectivity spectrum of the CPR at the lower reflectivity end of the spectrum, concomitantly at lighter rain rates. With the functional in place, it is then possible to produce synthetic CloudSat precipitation imagery over the PR track and thus over the diurnal time period. These augmented data are then used to study the spectral-vertical diurnal properties of precipitation over oceanic regions observed by TRMM.

Smith, Eric A.↗

Starburst Galaxies: Hard X-ray spectra and contribution to the diffuse background

During the period of this grant two main tasks were performed: a determination of a selection criterion for starburst galaxies most likely to emit X-rays, and performance of a pilot study of the X-ray emission from nine such systems. Starburst galaxies may be expected to emit flat-spectrum X-ray at energies above 10 keV resulting from the various remnants of the short-lived massive stars which characterize the starburst. The investigation to determine the optimum sample resulted in a change from an X-ray selected (HEAO-2) sample to infrared selection based on the IRAS catalogue. A much broader sample thereby available for study, and selection could be limited to only the nearest objects and still obtain a reasonably large sample. A sample of 99 of the brightest infrared starburst galaxies was settled on for the X-ray survey. For a set of practical size, this was then reduced to a subset of 53, based on luminosity and nearness. X-ray emission from these objects was individually measured from the UCSD HEAO-1 all-sky survey in four energy bands between 13 keV to 160 keV. This data base consists of about 20 optical disk volumes. Net significance for the result was roughly two sigma, and a very hard spectral shape is indicated for the net spectrum of the surveyed galaxies. With the possibility of detection of the class, it was then felt worthwhile to examine fluxes from these sources in other archival data. This was performed with the HEAO-1 A2 data and the HEAO-2 (EINSTEIN) main archive and slew survey. Positive results were also obtained for the sample, but again at weak significance. With three independent measures of weak X-ray fluxes from nearby starburst galaxies, we wrote a letter to the Astrophysical Journal (enclosed) discussing these results and their likely significance, in particular, for the contribution to the cosmic diffuse x-ray background, perhaps as much as 25 percent.

Gruber, Duane E.↗

Nepheline: Structure of Three Samples from the Bancroft Area, Ontario, Obtained using Synchrotron High-Resolution Powder X-Ray Diffraction

The crystal structure of three samples of nepheline (ideally, K{sub 2}Na{sub 6}[Al{sub 8}Si{sub 8}O{sub 32}]) from the Bancroft area of Ontario (1a, b: Egan Chute, 2: Nephton, and 3: Davis Hill), each with different types of superstructure reflections, has been studied using synchrotron high-resolution powder X-ray diffraction (HRPXRD) data and Rietveld structure refinement. The samples have different origins. The structure was refined in space group P6{sub 3}. The R{sub F}{sup 2} index, number of unique observed reflections, pseudohexagonal subcell parameters, and site-occupancy factor (sof) for the K site are as follows: Sample 1b: R{sub F}{sup 2} = 0.0433, N{sub obs} = 1399, a = 9.99567(1), c = 8.37777(1) {angstrom}, V = 724.907(2) {angstrom}{sub 3}, and K (sof) = 0.716(1). Sample 2: R{sub F}{sup 2} = 0.0669, N{sub obs} = 1589, a = 10.00215(1), c = 8.38742(1) {angstrom}, V = 726.684(1) {angstrom}{sub 3}, and K (sof) = 0.920(1). Sample 3: R{sub F}{sup 2} = 0.0804, N{sub obs} = 1615, a = 9.99567(1), c = 8.37873(1) {angstrom}, V = 724.991(1) {angstrom}{sub 3}, and K (sof) = 0.778(2). Sample 2 has the largest sof for K and the largest volume. The satellite reflections in the three nepheline samples were observed in the HRPXRD traces and give rise to different incommensurate superstructures. The Al and Si atoms in the T{sub 3} and T{sub 4} sites are ordered differently in the three samples, which may indicate the presence of a domain structure based on Al-Si order. The positions for the Al and Si atoms were interchanged in two samples because of the resulting <T-O> distances. The slight excess of Si over Al atoms, characteristically encountered in well-analyzed samples of nepheline, is reflected in the <T-O> distances.

58 GEOSCIENCES↗

Complex permittivity measurements during high temperature recycling of space shuttle antenna window and dielectric heat shield materials

The research performed and the data obtained on candidate space shuttle antenna window and heat shield materials are presented. The measurement technique employs a free-space focused beam microwave bridge for obtaining RF transmission data, and a device which rotates a sample holder which is heated on one side by natural gas-air flames. The surface temperature of each sample is monitored by IR pyrometry; embedded and rear surface thermocouples are also used in obtaining temperature data. The surface of the sample undergoing test is subjected to approximately the same temperature/time profile that occurs at a proposed antenna position on the space shuttle as it re-enters. The samples are cycled through ten of these temperature profiles to determine the recycling effects. Very little change was noted in the materials due to the recycling.

Bassett, H. L.↗

The soft x-ray properties of a complete sample of optically selected quasars. 1: First results

We present the results of ROSAT position sensitive proportional counter (PSPC) observations of 10 quasars. These objects are part of our ROSAT program to observe a complete sample of optically selected quasars. This sample includes all 23 quasars from the bright quasar survey with a redshift z less than or = 0.400 and a Galactic H I column density N(sup Gal sub H I) less than 1.9 x 10(exp 20)/sq cm. These selection criteria, combined with the high sensitivity and improved energy resolution of the PSPC, allow us to determine the soft (approximately 0.2-2 keV) X-ray spectra of quasars with about an order of magnitude higher precision compared with earlier soft X-ray observations. The following main results are obtained: Strong correlations are suggested between the soft X-ray spectral slope alpha(sub x) and the following emission line parameters: H beta Full Width at Half Maximum (FWHM), L(sub O III), and the Fe II/H beta flux ratio. These correlations imply the following: (1) The quasar's environment is likely to be optically thin down to approximately 0.2 keV. (2) In most objects alpha(sub x) varies by less than approximately 10% on timescales shorter than a few years. (3) alpha(sub x) might be a useful absolute luminosity indicator in quasars. (4) The Galactic He I and H I column densities are well correlated. Most spectra are well characterized by a simple power law, with no evidence for either significant absorption excess or emission excess at low energies, to within approximately 30%. We find mean value of alpha(sub x) = -1.50 +/- 0.40, which is consistent with other ROSAT observations of quasars. However, this average is significantly steeper than suggested by earlier soft X-ray observations of the Einstein IPC. The 0.3 keV flux in our sample can be predicted to better than a factor of 2 once the 1.69 micrometer(s) flux is given. This implies that the X-ray variability power spectra of quasars flattens out between f approximately 10(exp -5) and f approximately 10(exp -8) Hz. A steep alpha(sub x) is mostly associated with a weak hard X-ray component, relative to the near-IR and optical emission, rather than a strong soft excess, and the scatter in the normalized 0.3 keV flux is significantly smaller than the scatter in the normalized 2 keV flux. This argues against either thin or thick accretion disks as the origin of the soft X-ray emission. Further possible implications of the results found here are briefly discussed.

Laor, Ari↗

Chemical Characterization of Crude Petroleum Using Nanospray Desorption Electrospray Ionization Coupled with High-Resolution Mass Spectrometry

Nanospray desorption electrospray ionization (nano-DESI) combined with high-resolution mass spectrometry was used for the first time for the analysis of liquid petroleum crude oil samples. The analysis was performed in both positive and negative ionization modes using three solvents one of which (acetonitrile/toluene mixture) is commonly used in petroleomics studies while two other polar solvents (acetonitrile/water and methanol/water mixtures) are generally not compatible with petroleum characterization using mass spectrometry. The results demonstrate that nano-DESI analysis efficiently ionizes petroleum constituents soluble in a particular solvent. When acetonitrile/toluene is used as a solvent, nano-DESI generates electrospray-like spectra. In contrast, strikingly different spectra were obtained using acetonitrile/water and methanol/water. Comparison with the literature data indicates that these solvents selectively extract water-soluble constituents of the crude oil. Water-soluble compounds are predominantly observed as sodium adducts in nano-DESI spectra indicating that addition of sodium to the solvent may be a viable approach for efficient ionization of water-soluble crude oil constituents. Nano-DESI enables rapid screening of different classes of compounds in crude oil samples using solvents that are rarely used for petroleum characterization.

02 PETROLEUM↗

Tissue Distribution of Mercury in the Bodies of Wild American Alligators ( Alligator mississippiensis ) from a Coastal Marsh in Louisiana (USA)

Total mercury (THg) concentrations were measured in wild alligators inhabiting a coastal marsh in southern Louisiana, to determine the tissue distribution of THg among various body organs and tissue compartments. Concentrations of THg in claws and dermal tail scutes were compared to those in blood, brain, gonad, heart, kidney, liver, and skeletal muscle to determine if the former tissues, commonly available by non-lethal sampling, could be used as measures of body burdens in various internal organs. Mercury was found in all body organs and tissue compartments. However, overall, THg concentrations measured in alligators were below the FDA action level for fish consumption and were comparable to previous data reported from southwestern Louisiana. Here, our results suggest consumption of meat from alligators found in this region may be of little public health concern. However, the extended period of time between sampling (in this study) and the present-day highlight the need for continuous, additional, and more recent sampling to ensure consumer safety. Total mercury concentrations were highest in the kidney (3.18 ± 0.69 mg/kg dw) and liver (3.12 ± 0.76 mg/kg dw). THg levels in non-lethal samples (blood, claws, and dermal tail scutes) were positively correlated with all tissue THg concentrations (blood: R 2 = 0.513 – 0.988; claw: R 2 = 0.347 – 0.637, scutes: R 2 = 0.333 – 0.649). Because THg concentrations from blood, claws, and scutes were correlated with those of the internal organs, non-lethal sampling methods may be a viable method of estimating levels of THg in other body tissues.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Improved calibration of area detectors using multiple placements

Calibration of area detectors from powder diffraction standards is widely used at synchrotron beamlines. From a single diffraction image, it is not possible to determine both the sample-to-detector distance and the wavelength, but, with images taken from multiple positions along the beam direction and where the relative displacement is known, the sample-to-detector distance and wavelength can both be determined with good precision. Finally, an example calibration using the GSAS-II software package is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

QUANTIFYING KINEMATIC SUBSTRUCTURE IN THE MILKY WAY'S STELLAR HALO

We present and analyze the positions, distances, and radial velocities for over 4000 blue horizontal-branch (BHB) stars in the Milky Way's halo, drawn from SDSS DR8. We search for position-velocity substructure in these data, a signature of the hierarchical assembly of the stellar halo. Using a cumulative 'close pair distribution' as a statistic in the four-dimensional space of sky position, distance, and velocity, we quantify the presence of position-velocity substructure at high statistical significance among the BHB stars: pairs of BHB stars that are close in position on the sky tend to have more similar distances and radial velocities compared to a random sampling of these overall distributions. We make analogous mock observations of 11 numerical halo formation simulations, in which the stellar halo is entirely composed of disrupted satellite debris, and find a level of substructure comparable to that seen in the actually observed BHB star sample. This result quantitatively confirms the hierarchical build-up of the stellar halo through a signature in phase (position-velocity) space. In detail, the structure present in the BHB stars is somewhat less prominent than that seen in most simulated halos, quite possibly because BHB stars represent an older sub-population. BHB stars located beyond 20 kpc from the Galactic center exhibit stronger substructure than at r{sub gc} < 20 kpc.

79 ASTRONOMY AND ASTROPHYSICS↗

Photoluminescence in silicon implanted with silicon ions at amorphizing doses

Luminescent and structural properties of n-FZ-Si and n-Cz-Si implanted with Si ions at amorphizing doses and annealed at 1100 Degree-Sign C in a chlorine-containing atmosphere have been studied. An analysis of proton Rutherford backscattering spectra of implanted samples demonstrated that an amorphous layer is formed, and its position and thickness depend on the implantation dose. An X-ray diffraction analysis revealed that defects of the interstitial type are formed in the samples upon annealing. Photoluminescence spectra measured at 78 K and low excitation levels are dominated by the dislocation-related line D1, which is also observed at 300 K. The peak position of this line, its full width at half-maximum, and intensity depend on the conduction type of Si and implantation dose. As the luminescence excitation power is raised, a continuous band appears in the spectrum. A model is suggested that explains the fundamental aspects of the behavior of the photoluminescence spectra in relation to the experimental conditions.

36 MATERIALS SCIENCE↗

Rapid sample classification using an open port sampling interface coupled with liquid introduction atmospheric pressure ionization mass spectrometry

An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized the spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of lithium incorporation on tweaking the electrocatalytic behavior of tantalum-based oxides

To study the effect of lithium incorporation on the electrochemical properties and catalytic behavior of tantalum-based oxides, a series of mesoporous lithium-contained tantalum oxides was developed adopting an inverse micelle-based sol gel synthesis method. Four various phases of amorphous Ta 2 O 5 , polycrystalline LiTaO 3 , Li 5.04 Ta 6.16 O 17.92 , and Li 3 TaO 4 were determined for samples synthesized at Li/Ta ratios of 0.5 (LTO-0.5), 1 (LTO-1), 2 (LTO-2), and 3 (LTO-3) respectively. The surface analysis revealed that LTO-2 sample is featured with lower amount of lithium atoms at the surface rather than the bulk of the sample. The electrochemical analysis of LTO samples showed that LTO-2 possesses lower charge transfer resistance extracted from impedance spectroscopy that consequently leads to a better electrocatalytic performance. The LTO-2 electrode also showed a low open circuit potential (OCP) combined with a relatively higher electroactive surface area, thus capable of running an electrooxidation reaction at a potential lower than all other LTO samples. The more negative OCP value of LTO-2 electrode in AA solution states a more facile electron transfer between the analyte and electrode compared to other synthesized samples. Mott–Schottky plots of LTO electrodes are characterized by positive slopes which indicate n-type semiconductor behavior. The charge carrier density (5.5 × 10 19 cm -3 ) in LTO-2 sample is the lowest among all other samples. The charge carrier density is dependent on the amount of applied lithium in the synthesis confirming various lithium diffusion behaviors in LTO samples. The lower carrier concentration in LTO-2 justifies its higher activity in electrooxidation providing less populated lower unoccupied molecular orbital (LUMO) for the accommodation of electrons extracted from the analyte higher occupied molecular orbital (HOMO). Therefore, LTO-2 showed an improved electrocatalytic performance due to lower charge transfer resistance (higher conductivity) offered by lower amount of lithium atom at its surface and higher oxygen vacancies in the bulk.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ISOLOK VALVE ACCEPTANCE TESTING FOR DWPF SME SAMPLING PROCESS

Evaluation of the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) cycle time identified several opportunities to improve the CPC processing time. Of the opportunities, a focus area related to optimizing the equipment and efficiency of the sample turnaround time for DWPF Analytical Laboratory was identified. The Mechanical Systems & Custom Equipment Development (MS&CED) Section of the Savannah River National Laboratory (SRNL) evaluated the possibility of using an Isolok{reg_sign} sampling valve as an alternative to the Hydragard{reg_sign} valve for taking process samples. Previous viability testing was conducted with favorable results using the Isolok sampler and reported in SRNL-STI-2010-00749 (1). This task has the potential to improve operability, reduce maintenance time and decrease CPC cycle time. This report summarizes the results from acceptance testing which was requested in Task Technical Request (TTR) HLW-DWPF-TTR-2010-0036 (2) and which was conducted as outlined in Task Technical and Quality Assurance Plan (TTQAP) SRNL-RP-2011-00145 (3). The Isolok to be tested is the same model which was tested, qualified, and installed in the Sludge Receipt Adjustment Tank (SRAT) sample system. RW-0333P QA requirements apply to this task. This task was to qualify the Isolok sampler for use in the DWPF Slurry Mix Evaporator (SME) sampling process. The Hydragard, which is the current baseline sampling method, was used for comparison to the Isolok sampling data. The Isolok sampler is an air powered grab sampler used to 'pull' a sample volume from a process line. The operation of the sampler is shown in Figure 1. The image on the left shows the Isolok's spool extended into the process line and the image on the right shows the sampler retracted and then dispensing the liquid into the sampling container. To determine tank homogeneity, a Coliwasa sampler was used to grab samples at a high and low location within the mixing tank. Data from the two locations were compared to determine if the contents of the tank were well mixed. The Coliwasa sampler is a tube with a stopper at the bottom and is designed to obtain grab samples from specific locations within the drum contents. A position paper (4) was issued to address the prototypic flow loop issues and simulant selections. A statistically designed plan (5) was issued to address the total number of samples each sampler needed to pull, to provide the random order in which samples were pulled and to group samples for elemental analysis. The TTR required that the Isolok sampler perform as well as the Hydragard sampler during these tests to ensure the acceptability of the Isolok sampler for use in the DWPF sampling cells. Procedure No.L9.4-5015 was used to document the sample parameters and process steps. Completed procedures are located in R&D Engineering job folder 23269.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗