Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Rapidly quantifying the relative distention of a human bladder

A device and method of rapidly quantifying the relative distention of the bladder in a human subject are disclosed. The ultrasonic transducer which is positioned on the subject in proximity to the bladder is excited by a pulser under the command of a microprocessor to launch an acoustic wave into the patient. This wave interacts with the bladder walls and is reflected back to the ultrasonic transducer, when it is received, amplified and processed by the receiver. The resulting signal is digitized by an analog-to-digital converter under the command of the microprocessor and is stored in the data memory. The software in the microprocessor determines the relative distention of the bladder as a function of the propagated ultrasonic energy; and based on programmed scientific measurements and individual, anatomical, and behavioral characterists of the specific subject as contained in the program memory, sends out a signal to turn on any or all of the audible alarm, the visible alarm, the tactile alarm, and the remote wireless alarm.

Companion, John A.↗

Rapidly quantifying the relative distention of a human bladder

A device and method was developed to rapidly quantify the relative distention of the bladder of a human subject. An ultrasonic transducer is positioned on the human subject near the bladder. A microprocessor controlled pulser excites the transducer by sending an acoustic wave into the human subject. This wave interacts with the bladder walls and is reflected back to the ultrasonic transducer where it is received, amplified, and processed by the receiver. The resulting signal is digitized by an analog to digital converter, controlled by the microprocessor again, and is stored in data memory. The software in the microprocessor determines the relative distention of the bladder as a function of the propagated ultrasonic energy. Based on programmed scientific measurements and the human subject's past history as contained in program memory, the microprocessor sends out a signal to turn on any or all of the available alarms. The alarm system includes and audible alarm, the visible alarm, the tactile alarm, and the remote wireless alarm.

Companion, John A.↗

Parameter trade-offs for imaging spectroscopy systems

With the advent of the EOS era and of configurable sensors, users of these instruments are faced with the twin problems of specifying data acquisition parameters and extracting desired information from the voluminous data. An application of a system model is made to explore system parameter trade-offs for a model sensor based on the High Resolution Imaging Spectrometer. Radiometric performance was studied, along with the effect on classification accuracy of several system parameters. Using a model scene based on typical agricultural reflectance and atmospheric conditions, the atmosphere and sensor are seen to have significant effects on the mean received signal and noise performance. The effect of random uncorrelated errors in the radiometric calibration of the detector array is seen to degrade system performance, especially in the spectral bands below 1 micron. Accurate pixel-to-pixel relative radiometric calibration and the use of the Image Motion Compensation option are seen to improve classification accuracy, especially at high solar zenith angles. Feature sets chosen from characteristics of the scene performed best overall, but ones chosen based on signal-to-noise ratios were seen to be more robust.

Kerekes, John P.↗

SeaWiFS Calibration and Algorithm Validation

This is the fourth annual report on NASA grant NAGW 3543, titled 'Sea-viewing Wide Field of view Sensor (SeaWiFS) calibration and algorithm validation'. An extended field experiment was conducted at Lake Tahoe in late July 1996 that involved: experimental verification of radiative transfer computations for various viewing geometries; retrieval of an effective aerosol optical depth height; calibration of a large field of view (FOV) sensor; and an evaluation of spatial non-uniformities in surface reflectance. The investigation and development of novel methods for the calibration of field radiometers at a variety of signal levels has been continued during the past year.

Parada, Robert J., Jr.↗

The Stability of Human Eye Orientation During Visual Fixation

Using the magnetic search coil technique, gaze stability in the horizontal, vertical and torsional planes was measured binocularly in human subjects during visual fixation. Horizontal and vertical eye rotations exhibited a mixture of slow drifts and resetting microsaccades yielding an average standard deviation of 0.11 and 0.10 deg. respectively. In contrast, torsional rotations showed unsystematic smooth drifts with fewer saccades yielding an average standard deviation of 0.18 deg. The lower precision of gaze control in the torsional plane may reflect (1) a discrepancy between the encoding of retinal images in two dimensions but of ocular motor control signals in three dimensions, and (2) the visual consequences of ocular drifts in the torsional plane, which differ from those in the horizontal and vertical planes.

Ott, Dietmar↗

All-Optical Micro Motors Based on Moving Gratings in Photosensitive Media

An all-optical micromotor with a rotor driven by a traveling wave of surface deformation of a stator being in contact with the rotor is being studied. Instead of an ultrasonic wave produced by an electrically driven piezoelectric actuator as in ultrasonic motors, the wave is a result of a photo-induced surface deformation of a photosensitive material produced by an incident radiation. A thin piezoelectric polymer will deform more easily LiNbO3 or metal when irradiated with light. The type of photosensitive material studied are piezoelectric polymers with and without coatings for connecting electrodes. In order to be considered as a possible candidate for micromotors, the material should exhibit surface deformation produced by a laser beam of the order of 10 microns. This is compared to the deformations produced by static holographic gratings studied in photorefractive crystals of LiNbO3 using high vertical resolution surface profilometer Dektak 3 and surface interferometer WYKO. An experimental setup showing the oscillations has been developed. The setup uses a chopped beam from an Argon ion laser to produce the deformation while a probe beam is reflected by the thin film into a fiber which is then detected on an oscilloscope. A ramp voltage signal generator will drive the piezoelectric film in another experiment to determine the resonance of the film. A current is generated when light is incident upon the film and this current can be measured. The reverse process has already been demonstrated in other piezoelectric actuators. Changing voltage, polarity, and frequency of the signal can easily generate vibrations similar to those when light is incident on the film. This can be compared to the effects of laser interaction with light absorbing fluids such as solutions of 2,9,16,23-Tetrakis(phenylthio)-29H, 31 H-phthalocyanine in chlorobenzene in capillary tubes, The possibility of using a liquid with the piezoelectric film would be a novel idea for a micromotor since the interaction of a single low power focused laser beam at 633 nm with such fluid produced an intensive circular motion.

Curley, M.↗

Axisymmetric Flow Properties for Magnetic Elements of Differing Strength

Aspects of the structure and dynamics of the flows in the Sun's surface shear layer remain uncertain and yet are critically important for understanding the observed magnetic behavior. In our previous studies of the axisymmetric transport of magnetic elements we found systematic changes in both the differential rotation and the meridional flow over the course of Solar Cycle 23. Here we examine how those flows depend upon the strength (and presumably anchoring depth) of the magnetic elements. Line of sight magnetograms obtained by the HMI instrument aboard SDO over the course of Carrington Rotation 2097 were mapped to heliographic coordinates and averaged over 12 minutes to remove the 5-min oscillations. Data masks were constructed based on the field strength of each mapped pixel to isolate magnetic elements of differing field strength. We used Local Correlation Tracking of the unmasked data (separated in time by 1- to 8-hours) to determine the longitudinal and latitudinal motions of the magnetic elements. We then calculated average flow velocities as functions of latitude and longitude from the central meridian for approx 600 image pairs over the 27-day rotation. Variations with longitude indicate and characterize systematic errors in the flow measurements associated with changes in the signal from disk center to limb. Removing these systematic errors reveals changes in the axisymmetric flow properties that reflect changes in flow properties with depth in the surface shear layer.

Rightmire-Upton, Lisa↗

Composite Reflective Absorptive IR-Blocking Filters Embedded in Metamaterial Antireflection Coated Silicon

Infrared (IR)-blocking filters are crucial for controlling the radiative loading on cryogenic systems and for optimizing the sensitivity of bolometric detectors in the far-IR. We present a new IR filter approach based on a combination of patterned frequency-selective structures on silicon and a thin (2575 micron thick) absorptive composite based on powdered reststrahlen absorbing materials. For a 300 K blackbody, this combination reflects approximately 50% of the incoming light and blocks greater than.99.8% of the total power with negligible thermal gradients and excellent low-frequency transmission. This allows a reduction in the IR thermal loading to negligible levels in a single cold filter. These composite filters are fabricated on silicon substrates, which provide excellent thermal transport laterally through the filter and ensure that the entire area of the absorptive filter stays near the bath temperature. A metamaterial antireflection coating cut into these substrates reduces in-band reflections to below 1%, and the in-band absorption of the powder mix is below 1% for signal bands below 750 GHz. This type of filter can be directly incorporated into silicon refractive optical elements.

Munson, C. D.↗

Interpreting Precession-Driven δ O-18 Variability in the South Asian Monsoon Region

Speleothem records from the South Asian summer monsoon (SASM) region display variability in the ratio of O-18 and O-16 (δ O-18) in calcium carbonate at orbital frequencies. The dominant mode of variability in many of these records reflects cycles of precession. There are several potential explanations for why SASM speleothem records show a strong precession signal, including changes in temperature, precipitation, and circulation. Here we use an Earth system model with water isotope tracers and water-tagging capability to deconstruct the precession signal found in SASM speleothem records. Our results show that cycles of precession-eccentricity produce changes in SASM intensity that correlate with local temperature, precipitation, and δ O-18. However, neither the amount effect nor temperature differences are responsible for the majority of the SASM δ O-18 variability. Instead, changes in the relative moisture contributions from different source regions drive much of the SASM δ O-18 signal, with more nearby moisture sources during Northern Hemisphere summer at aphelion and more distant moisture sources during Northern Hemisphere summer at perihelion. Further, we find that evaporation amplifies the δ O-18 signal of soil water relative to that of precipitation, providing a better match with the SASM speleothem records. This work helps explain a significant portion of the long-term variability found in SASM speleothem records.

paleoclimate↗

On recursive least-squares filtering algorithms and implementations

In many real-time signal processing applications, fast and numerically stable algorithms for solving least-squares problems are necessary and important. In particular, under non-stationary conditions, these algorithms must be able to adapt themselves to reflect the changes in the system and take appropriate adjustments to achieve optimum performances. Among existing algorithms, the QR-decomposition (QRD)-based recursive least-squares (RLS) methods have been shown to be useful and effective for adaptive signal processing. In order to increase the speed of processing and achieve high throughput rate, many algorithms are being vectorized and/or pipelined to facilitate high degrees of parallelism. A time-recursive formulation of RLS filtering employing block QRD will be considered first. Several methods, including a new non-continuous windowing scheme based on selectively rejecting contaminated data, were investigated for adaptive processing. Based on systolic triarrays, many other forms of systolic arrays are shown to be capable of implementing different algorithms. Various updating and downdating systolic algorithms and architectures for RLS filtering are examined and compared in details, which include Householder reflector, Gram-Schmidt procedure, and Givens rotation. A unified approach encompassing existing square-root-free algorithms is also proposed. For the sinusoidal spectrum estimation problem, a judicious method of separating the noise from the signal is of great interest. Various truncated QR methods are proposed for this purpose and compared to the truncated SVD method. Computer simulations provided for detailed comparisons show the effectiveness of these methods. This thesis deals with fundamental issues of numerical stability, computational efficiency, adaptivity, and VLSI implementation for the RLS filtering problems. In all, various new and modified algorithms and architectures are proposed and analyzed; the significance of any of the new method depends crucially on specific application.

Hsieh, Shih-Fu↗

Utilizing the MODIS 1.38 micrometer Channel for Cirrus Cloud Optical Thickness Retrievals: Algorithm and Retrieval Uncertainties

The cloud products from the Moderate Resolution Imaging Spectroradiometers (MODIS) on Terra and Aqua have been widely used within the atmospheric research community. The retrieval algorithms, however, oftentimes have difficulty detecting and retrieving thin cirrus, due to sensitivities to surface reflectance. Conversely, the 1.38 micron channel, located within a strong water vapor absorption band, is quite useful for detecting thin cirrus clouds since the signal from the surface can be blocked or substantially attenuated by the absorption of atmospheric water vapor below cirrus. This channel, however, suffers from nonnegligible attenuation due to the water vapor located above and within the cloud layer. Here we provide details of a new technique pairing the 1.38 micron and 1.24 micron channels to estimate the above/in-cloud water vapor attenuation and to subsequently retrieve thin cirrus optical thickness (tau) from attenuation-corrected 1.38 p.m reflectance measurements. In selected oceanic cases, this approach is found to increase cirrus retrievals by up to 38% over MOD06. For these cases, baseline 1.38 micron retrieval uncertainties are estimated to be between 15 and 20% for moderately thick cirrus (tau > 1), with the largest error source being the unknown cloud effective particle radius, which is not retrieved with the described technique. Uncertainties increase to around 90% for the thinnest clouds (tau < 0.5) where instrument and surface uncertainties dominate.

Meyer, Kerry↗

Developing Atmospheric Retrieval Methods for Direct Imaging Spectroscopy of Gas Giants in Reflected Light I: Methane Abundances and Basic Cloud Properties

Reflected light spectroscopy and photometry of cool, directly imaged extrasolar giant planets are expected to be performed in the next decade by space-based telescopes equipped with optical wavelength coronagraphs and integral field spectrographs, such as the Wide-Field Infrared Survey Telescope (WFIRST). We are developing a new atmospheric retrieval methodology to help assess the science return and inform the instrument design for such future missions, and ultimately interpret the resulting observations. Our retrieval technique employs an albedo model coupled with both a Markov chain Monte Carlo Ensemble Sampler (emcee) and a multimodal nested sampling algorithm (MultiNest) to map the posterior distribution. This combination makes the global evidence calculation more robust for any given model, and highlights possible discrepancies in the likelihood maps. Here we apply this methodology to simulated spectra of cool giant planets. As a proof-of-concept, our current atmospheric model contains 1 or 2 cloud layers, methane as a major absorber, and a H2-He background gas. This 6-to-9 parameter model is appropriate for Jupiter-like planets and can be easily expanded in the future. In addition to deriving the marginal likelihood distribution and confidence intervals for the model parameters, we perform model selection to determine the significance of methane and cloud detection as a function of expected signal-to-noise, in the presence of spectral noise correlations. After internal validation, the method is applied to realistic reflected-light spectra of Jupiter, Saturn, and HD 99492 c, a likely observing target. We find that the presence or absence of clouds and methane can be determined with high accuracy, while parameters uncertainties are model-dependent.

spectroscopy↗

Polarimetric Radar Characteristics of Simulated and Observed Intense Convective Cores for a Midlatitude Continental and Tropical Maritime Environment

This study contrasts midlatitude continental and tropical maritime deep convective cores using polarimetric radar observables and retrievals from selected deep convection episodes during the MC3E and TWPICE field campaigns. The continental convective cores produce stronger radar reflectivities throughout the profiles, while maritime convective cores produce more positive differential reflectivity Z dr and larger specific differential phase K dp above the melting level. Hydrometeor identification retrievals revealed the presence of large fractions of rimed ice particles (snow aggregates) in the continental (maritime) convective cores, consistent with the Z dr and K dp observations. The regional cloud-resolving model simulations with bulk and size-resolved bin microphysics are conducted for the selected cases, and the simulation outputs are converted into polarimetric radar signals and retrievals identical to the observational composites. Both the bulk and the bin microphysics reproduce realistic land and ocean (L-O) contrasts in reflectivity, polarimetric variables of rain drops, and hydrometeor profiles, but there are still large uncertainties in describing Z dr and K dp of ice crystals associated with the ice particle shapes/orientation assumptions. Sensitivity experiments are conducted by swapping background aerosols between the continental and maritime environments, revealing that background aerosols play a role in shaping the distinct L-O contrasts in radar reflectivity associated with raindrop sizes, in addition to the dominant role of background thermodynamics.

54 ENVIRONMENTAL SCIENCES↗

Polarimetric Radar Characteristics of Simulated and Observed Intense Convective Cores for a Midlatitude Continental and Tropical Maritime Environment

This study contrasts midlatitude continental and tropical maritime deep convective cores using polarimetric radar observables and retrievals from selected deep convection episodes during the MC3E and TWPICE field campaigns. The continental convective cores produce stronger radar reflectivities throughout the profiles, while maritime convective cores produce more positive differential reflectivity Z(dr) and larger specific differential phase K(dp) above the melting level. Hydrometeor identification retrievals revealed the presence of large fractions of rimed ice particles (snow aggregates) in the continental (maritime) convective cores, consistent with the Z(dr) and K(dp) observations. The regional cloud-resolving model simulations with bulk and size-resolved bin microphysics are conducted for the selected cases, and the simulation outputs are converted into polarimetric radar signals and retrievals identical to the observational composites. Both the bulk and the bin microphysics reproduce realistic land and ocean (L-O) contrasts in reflectivity, polarimetric variables of rain drops, and hydrometeor profiles, but there are still large uncertainties in describing Zdr and Kdp of ice crystals associated with the ice particle shapes/orientation assumptions. Sensitivity experiments are conducted by swapping background aerosols between the continental and maritime environments, revealing that background aerosols play a role in shaping the distinct L-O contrasts in radar reflectivity associated with raindrop sizes, in addition to the dominant role of background thermodynamics.

Toshihisa Matsui↗

QWIP: A Quantitative Metric for Quality Control of Aquatic Reflectance Spectral Shape using the Apparent Visible Wavelength

The colors of the ocean and inland waters span clear blue to turbid brown, and the corresponding spectral shapes of the waterleaving signal are diverse depending on the various types and concentrations of phytoplankton, sediment, detritus and colored dissolved organic matter. Here we present a simple metric developed from a global dataset spanning blue, green and brown water types to assess the quality of a measured or derived aquatic spectrum. The Quality Water Index Polynomial (QWIP) is founded on the Apparent Visible Wavelength (AVW), a one-dimensional geophysical metric of color that is inherently correlated to spectral shape calculated as a weighted harmonic mean across visible wavelengths. The QWIP represents a polynomial relationship between the hyperspectral AVW and a Normalized Difference Index (NDI) using red and green wavelengths. The QWIP score represents the difference between a spectrum’s AVW and NDI and the QWIP polynomial. The approach is tested extensively with both raw and quality controlled field data to identify spectra that fall outside the general trends observed in aquatic optics. For example, QWIP scores less than or greater than 0.2 would fail an initial screening and be subject to additional quality control. Common outliers tend to have spectral features related to: 1) incorrect removal of surface reflected skylight or 2) optically shallow water. The approach was applied to hyperspectral imagery from the Hyperspectral Imager for the Coastal Ocean (HICO), as well as to multispectral imagery from the Visual Infrared Imaging Radiometer Suite (VIIRS) using sensor-specific extrapolations to approximate AVW. This simple approach can be rapidly implemented in ocean color processing chains to provide a level of uncertainty about a measured or retrieved spectrum and flag questionable or unusual spectra for further analysis.

remote sensing reflectance↗

Grating Demultiplexers for Optical Signals

Two systems proposed to increase wavelength resolution. Two paraboloidal reflectors and grating separate light into component colors. First paraboloid forms input light into nearly planar waves. Reflected from planar grating at various angles depending on wavelength. Second paraboloid focuses separate wavelengths to separate lines.

Marom, E.↗

In Liquid Infrared Scattering Scanning Near-Field Optical Microscopy for Chemical and Biological Nanoimaging

Imaging biological systems with simultaneous intrinsic chemical specificity and nanometer spatial resolution in their typical native liquid environment has remained a long-standing challenge. In this paper we demonstrate a general approach of chemical nanoimaging in liquid based on infrared scattering scanning near-field optical microscopy (IR $s$-SNOM). It is enabled by combining AFM operation in a fluid cell with evanescent IR illumination via total internal reflection, which provides spatially confined excitation for minimized IR water absorption, reduced far-field background, and enhanced directional signal emission and sensitivity. We demonstrate in-liquid IR $s$-SNOM vibrational nanoimaging and conformational identification of catalase nano-crystals and spatio-spectral analysis of biomimetic peptoid sheets with monolayer sensitivity and chemical specificity at the few zeptomole level. This work establishes the principles of in-liquid and in-situ IR $s$-SNOM spectroscopic chemical nano-imaging and its general applicability to biomolecular, cellular, catalytic, electrochemical, or other interfaces and nano-systems in liquids or solutions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A compact fiber optics-based heterodyne combined normal and transverse displacement interferometer

While Photonic Doppler Velocimetry (PDV) has become a common diagnostic tool for the measurement of normal component of particle motion in shock wave experiments, this technique has not yet been modified for the measurement of combined normal and transverse motion, as needed in oblique plate impact experiments. In this study, we discuss the design and implementation of a compact fiber-optics-based heterodyne combined normal and transverse displacement interferometer. Like the standard PDV, this diagnostic tool is assembled using commercially available telecommunications hardware and uses a 1550 nm wavelength 2 W fiber-coupled laser, an optical focuser, and single mode fibers to transport light to and from the target. Two additional optical probes capture first-order beams diffracted from a reflective grating at the target free-surface and deliver the beams past circulators and a coupler where the signal is combined to form a beat frequency. The combined signal is then digitized and analyzed to determine the transverse component of the particle motion. The maximum normal velocity that can be measured by this system is limited by the equivalent transmission bandwidth (3.795 GHz) of the combined detector, amplifier, and digitizer and is estimated to be ~2.9 km/s. Finally, sample symmetric oblique plate-impact experiments are performed to demonstrate the capability of this diagnostic tool in the measurement of the combined normal and transverse displacement particle motion.

47 OTHER INSTRUMENTATION↗