Search NASA⌕ Search

SEARCH · Search NASA

Results for “STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

A practical method to test the validity of the standard Gumbel distribution in logit-based multinomial choice models of travel behavior

Most multinomial choice models (e.g., the multinomial logit model) adopted in practice assume an extreme-value Gumbel distribution for the random components (error terms) of utility functions. This distributional assumption offers a closed-form likelihood expression when the utility maximization principle is applied to model choice behaviors. As a result, model coefficients can be easily estimated using the standard maximum likelihood estimation method. However, maximum likelihood estimators are consistent and efficient only if distributional assumptions on the random error terms are valid. It is therefore critical to test the validity of underlying distributional assumptions on the error terms that form the basis of parameter estimation and policy evaluation. In this paper, a practical yet statistically rigorous method is proposed to test the validity of the distributional assumption on the random components of utility functions in both the multinomial logit (MNL) model and multiple discrete-continuous extreme value (MDCEV) model. Based on a semi-nonparametric approach, a closed-form likelihood function that nests the MNL or MDCEV model being tested is derived. The proposed method allows traditional likelihood ratio tests to be used to test violations of the standard Gumbel distribution assumption. Simulation experiments are conducted to demonstrate that the proposed test yields acceptable Type-I and Type-II error probabilities at commonly available sample sizes. The test is then applied to three real-world discrete and discrete-continuous choice models. For all three models, the proposed test rejects the validity of the standard Gumbel distribution in most utility functions, calling for the development of robust choice models that overcome adverse effects of violations of distributional assumptions on the error terms in random utility functions.

30 DIRECT ENERGY CONVERSION↗

In Pursuit of a High-Temperature, High-Pressure, High-Viscosity Standard: The Case of Tris(2-ethylhexyl) Trimellitate

This study presents a reference correlation for the viscosity of tris(2-ethylhexyl) trimellitate designed to serve in industrial applications for the calibration of viscometers at elevated temperatures and pressures such as those encountered in the exploration of oil reservoirs and in lubrication. Tris(2-ethylhexyl) trimellitate has been examined with respect to the criteria necessary for an industrial standard reference material such as toxicity, thermal stability, and variability among manufactured lots. The viscosity correlation has been based upon all of the data collected in a multinational project and is supported by careful measurements and analysis of all the supporting thermophysical property data that are needed to apply the standard for calibration to a wide variety of viscometers. The standard reference viscosity data cover temperatures from 303 to 473 K, pressures from 0.1 to 200 MPa, and viscosities from approximately 1.6 to 755 mPa s. The uncertainty in the data provided is of the order of 3.2% at 95% confidence level, which is thought to be adequate for most industrial applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Equilibrated Gas and Carbonate Standard‐Derived Dual (Δ 47 and Δ 48 ) Clumped Isotope Values

Abstract Carbonate clumped isotope geochemistry has primarily focused on mass spectrometric determination of m/z 47 CO 2 for geothermometry, but theoretical calculations and recent experiments indicate paired analysis of the m/z 47 ( 13 C 18 O 16 O) and m/z 48 ( 12 C 18 O 18 O) isotopologues (referred to as Δ 47 and Δ 48 ) can be used to study non‐equilibrium isotope fractionations and refine temperature estimates. We utilize 5,448 Δ 47 and 3,400 Δ 48 replicate measurements of carbonate samples and standards, and 183 Δ 47 and 195 Δ 48 replicate measurements of gas standards from 2015 to 2021 from a multi‐year and multi‐instrument data set to constrain Δ 47 and Δ 48 values for 27 samples and standards, including Devils Hole cave calcite, and study equilibrium Δ 47 ‐Δ 48 , Δ 47 ‐temperature, and Δ 48 ‐temperature relationships. We compare results to previously published findings and calculate equilibrium regressions based on data from multiple laboratories. We report acid digestion fractionation factors, Δ* 63‐47 and Δ* 64‐48 , and account for their dependence on the initial clumped isotope values of the mineral.

58 GEOSCIENCES↗

Standardized excitable elements for scalable engineering of far-from-equilibrium chemical networks

Engineered far-from-equilibrium synthetic chemical networks that pulse or switch states in response to environmental signals could precisely regulate the kinetics of chemical synthesis or self-assembly. Currently, such networks must be extensively tuned to compensate for the different activities of and unintended reactions between a network’s various chemical components. Modular elements with standardized performance could be used to rapidly construct networks with designed functions. Here we develop standardized excitable chemical regulatory elements, termed genelets, and use them to construct complex in vitro transcriptional networks. We develop a protocol for identifying >15 interchangeable genelet elements with uniform performance and minimal crosstalk. Furthermore, these elements can be combined to engineer feedforward and feedback modules whose dynamics match those predicted by a simple kinetic model. Modules can then be rationally integrated and organized into networks that produce tunable temporal pulses and act as multistate switchable memories. Standardized genelet elements, and the workflow to identify more, should make engineering complex far-from-equilibrium chemical dynamics routine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗

Experimental spectrum averaged cross sections (SACS) in 252 Cf(sf) neutron field and its impact on the evaluation of neutron standards

A new evaluation of spectrum averaged cross sections (SACS) of 235 U, 238 U, and 239 Pu measured in the 252 Cf(sf) reference neutron field is presented and found to be consistent with the original Mannhart SACS evaluation in IRDF-2002. The comprehensive vetted experimental database that includes SACS ratio and absolute SACS measurements of major actinides is being used to update the SACS database employed as input of the new GMApy code to derive the Neutron Standards. An update of the current neutron standards based on Time Projection Chamber (TPC) shape data, a new comprehensive uncertainty quantification, and revised SACS experimental database is proposed which result in a 0.7% increase of the evaluated 239 Pu(n,f)/ 235 U(n,f) crosssection ratio in the 1–5 MeV energy region. The increase is due to a 0.3% reduction of the standard 235 U(n,f) cross section and a 0.4% increase of the 239 Pu(n,f) reference cross section in the 1–5 MeV energy region. Those changes are well within estimated USU fission cross-section uncertainties of 1.2%, but are relevant for the evaluated mean values.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiometric calibration of optical microscopy and microspectroscopy apparata over a broad spectral range using a special thin-film luminescence standard

Application capabilities of optical microscopes and microspectroscopes can be considerably enhanced by a proper calibration of their spectral sensitivity. We propose and demonstrate a method of relative and absolute calibration of a microspectroscope over an extraordinary broad spectral range covered by two (parallel) detection branches in visible and near-infrared spectral regions. The key point of the absolute calibration of a relative spectral sensitivity is application of the standard sample formed by a thin layer of Si nanocrystals with stable and efficient photoluminescence. The spectral PL quantum yield and the PL spatial distribution of the standard sample must be characterized by separate experiments. The absolutely calibrated microspectroscope enables to characterize spectral photon emittance of a studied object or even its luminescence quantum yield (QY) if additional knowledge about spatial distribution of emission and about excitance is available. Capabilities of the calibrated microspectroscope are demonstrated by measuring external QY of electroluminescence from a standard poly-Si solar-cell and of photoluminescence of Er-doped Si nanocrystals.

36 MATERIALS SCIENCE↗

Contributed Review: Absolute spectral radiance calibration of fiber-optic shock-temperature pyrometers using a coiled-coil irradiance standard lamp

We describe an accurate and precise calibration procedure for multichannel optical pyrometers such as the 6-channel, 3-ns temporal resolution instrument used in the Caltech experimental geophysics laboratory. We begin with a review of calibration sources for shock temperatures in the 3000-30 000 K range. High-power, coiled tungsten halogen standards of spectral irradiance appear to be the only practical alternative to NIST-traceable tungsten ribbon lamps, which are no longer available with large enough calibrated area. However, non-uniform radiance complicates the use of such coiled lamps for reliable and reproducible calibration of pyrometers that employ imaging or relay optics. Careful analysis of documented methods of shock pyrometer calibration to coiled irradiance standard lamps shows that only one technique, not directly applicable in our case, is free of major radiometric errors. We provide a detailed description of the modified Caltech pyrometer instrument and a procedure for its absolute spectral radiance calibration, accurate to ±5%. We employ a designated central area of a 0.7× demagnified image of a coiled-coil tungsten halogen lamp filament, cross-calibrated against a NIST-traceable tungsten ribbon lamp. We give the results of the cross-calibration along with descriptions of the optical arrangement, data acquisition, and processing. We describe a procedure to characterize the difference between the static and dynamic response of amplified photodetectors, allowing time-dependent photodiode correction factors for spectral radiance histories from shock experiments. We validate correct operation of the modified Caltech pyrometer with actual shock temperature experiments on single-crystal NaCl and MgO and obtain very good agreement with the literature data for these substances. We conclude with a summary of the most essential requirements for error-free calibration of a fiber-optic shock-temperature pyrometer using a high-power coiled tungsten halogen irradiance standard lamp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Frequency shift of an optical frequency standard as a function of probe modulation of the radiation frequency, pressure, and gas temperature in an absorbing cell

Frequency shifts of an optical Nd : YAG/I{sub 2}-standard are measured in a pressure range of molecular iodine 5 – 22 mTorr and deviation of probe modulation frequency 480 kHz – 4 MHz for the hyperfine structure component a1 of the molecular iodine absorption line R(56) 32 – 0. The frequency shift of the optical standard is estimated under varied temperatures of a cell and cell finger, which determines the pressure of the molecular iodine vapour. The requirements are defined to temperature stability of the cell and its finger for obtaining high long-term frequency stability of the optical frequency standard. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative Analysis of Standard and Advanced USL Methodologies for Nuclear Criticality Safety

The American National Standards Institute/American Nuclear Society national standards 8.1 and 8.24 provide guidance on the requirements and recommendations for establishing confidence in the results of the computerized models used to support operation with fissionable materials. By design, the guidance is not prescriptive, leaving freedom to the analysts to determine how the various sources of uncertainties are to be statistically aggregated. Due to the involved use of statistics entangled with heuristic recipes, the resulting safety margins are often difficult to interpret. Also, these technical margins are augmented by additional administrative margins, which are required to ensure compliance with safety standards or regulations, eliminating the incentive to understand their differences. With the new resurgent wave of advanced nuclear systems, e.g., advanced reactors, fuel cycles, and fuel concepts, focused on economizing operation, there is a strong need to develop a clear understanding of the uncertainties and their consolidation methods to reduce them in manners that can be scientifically defended. In response, the current studies compare the analyses behind four notable methodologies for upper subcriticality limit estimation that have been documented in the nuclear criticality safety literature: the parametric, nonparametric, Whisper, and TSURFER methodologies. Specifically, the work offers a deep dive into the various assumptions of the noted methodologies, their adequacies, and their limitations to provide guidance on developing confidence for the emergent nuclear systems that are expected to be challenged by the scarcity of experimental data. Here, to limit the scope, the current work focuses on the application of these methodologies to criticality safety experiments, where the goal is to calculate a bias, a bias uncertainty, and a tolerance limit for k eff in support of determining an upper subcriticality limit for nuclear criticality safety.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The initial appraisal of buried DAS system in CO2CRC Otway Project: the comparison of buried standard fibre-optic and helically wound cables using 2D imaging

This study aims to assess the ability of shallow distributed acoustic sensing (DAS) to serve as a cost-effective seismic sensor array for permanent monitoring applications. To this end, as part of the CO2CRC seismic monitoring program, a fibre-optic DAS array was deployed alongside a permanently buried geophone array at the Otway Project site (Victoria, Australia). The DAS array consisted of a standard commercially available tactical fibre-optic cable, which was deployed in 0.8m deep trenches. A custom-designed helically wound (HW) cable was also deployed in one of the DAS trenches for comparison of the cable designs. Simultaneous acquisition of the seismic data was carried out using 3000 vibroseis source points and geophones, DAS standard and HW cables. For initial assessment of the seismic images acquired with DAS and to compare different cable designs, preliminary 2D seismic reflection processing is conducted on both DAS cables and geophone data along a single 2D line. The geophone data processing guided processing of the DAS data. Several shallow structures (100-450ms) and some important reflectors at 450-600ms are observed on the final DAS images. Comparison of the two different DAS cable types demonstrated that seismic imaging would benefit DAS technology. However, the benefit of utilising HW cable is modest compared with the standard cable. The workflows and results of this study pave the way for processing of the 3D seismic data set acquired with the DAS array, as well as further detailed analysis of the DAS cables and the system itself.

47 OTHER INSTRUMENTATION↗

UBVRI PHOTOMETRIC STANDARD STARS AROUND THE CELESTIAL EQUATOR: UPDATES AND ADDITIONS

New broadband UBVRI photoelectric observations on the Johnson-Kron-Cousins photometric system have been made of 202 stars around the sky, and centered at the celestial equator. These stars constitute both an update of and additions to a previously published list of equatorial photometric standard stars. The list is capable of providing, for both celestial hemispheres, an internally consistent homogeneous broadband standard photometric system around the sky. When these new measurements are included with those previously published by Landolt (1992), the entire list of standard stars in this paper encompasses the magnitude range 8.90 < V < 16.30, and the color index range -0.35 < (B - V) < +2.30.

79 ASTRONOMY AND ASTROPHYSICS↗

EXPLORING SHORT GAMMA-RAY BURSTS AS GRAVITATIONAL-WAVE STANDARD SIRENS

Recent observations support the hypothesis that a large fraction of 'short-hard' gamma-ray bursts (SHBs) are associated with the inspiral and merger of compact binaries. Since gravitational-wave (GW) measurements of well-localized inspiraling binaries can measure absolute source distances, simultaneous observation of a binary's GWs and SHB would allow us to directly and independently determine both the binary's luminosity distance and its redshift. Such a 'standard siren' (the GW analog of a standard candle) would provide an excellent probe of the nearby (z {approx}< 0.3) universe's expansion, independent of the cosmological distance ladder, thereby complementing other standard candles. Previous work explored this idea using a simplified formalism to study measurement by advanced GW detector networks, incorporating a high signal-to-noise ratio limit to describe the probability distribution for measured parameters. In this paper, we eliminate this simplification, constructing distributions with a Markov Chain Monte Carlo technique. We assume that each SHB observation gives source sky position and time of coalescence, and we take non-spinning binary neutron star and black hole-neutron star coalescences as plausible SHB progenitors. We examine how well parameters (particularly distance) can be measured from GW observations of SHBs by a range of ground-based detector networks. We find that earlier estimates overstate how well distances can be measured, even at fairly large signal-to-noise ratio. The fundamental limitation to determining distance proves to be a degeneracy between distance and source inclination. Overcoming this limitation requires that we either break this degeneracy, or measure enough sources to broadly sample the inclination distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

THE CASE FOR STANDARD IRRADIATED ACCRETION DISKS IN ACTIVE GALACTIC NUCLEI

We analyze the broadband photometric light curves of Seyfert 1 galaxies from the Sergeev et al. sample and find that (1) perturbations propagating across the continuum emitting region are a general phenomenon securely detected in most cases, (2) it is possible to obtain reliable time delays between continuum emission in different wavebands, which are not biased by the contribution of broad emission lines to the signal, and (3) such lags are consistent with the predictions of standard irradiated accretion disk models, given the optical luminosity of the sources. These findings provide new and independent support for standard accretion disks being responsible for the bulk of the (rest) optical emission in low-luminosity active galactic nuclei (AGNs). We interpret our lag measurements in individual objects within the framework of this model and estimate the typical mass accretion rate to be {approx}< 0.1 M{sub Sun} yr{sup -1}, with little dependence on the black hole mass. Assuming bolometric corrections typical of type I sources, we find tentative evidence for the radiative efficiency of accretion flows being a rising function of the black hole mass. With upcoming surveys that will regularly monitor the sky, we may be able to better quantify possible departures from standard self-similar models, and identify other modes of accretion in AGNs.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultra-high energy neutrino fluxes as a probe for non-standard physics

We examine how light neutrinos coming from distant active galactic nuclei (AGN) and similar high energy sources may be used as tools to probe non-standard physics. In particular we discuss how studying the energy spectra of each neutrino flavour coming from such distant sources and their distortion relative to each other may serve as pointers to exotic physics such as neutrino decay, Lorentz symmetry violation, pseudo-Dirac effects, CP and CPT violation and quantum decoherence. This allows us to probe hitherto unexplored ranges of parameters for the above cases, for example lifetimes in the range 10{sup −3}−10{sup 4} s/eV for the case of neutrino decay. We show that standard neutrino oscillations ensure that the different flavours arrive at the earth with similar shapes even if their flavour spectra at source may differ strongly in both shape and magnitude. As a result, observed differences between the spectra of various flavours at the detector would be signatures of non-standard physics altering neutrino fluxes during propagation rather than those arising during their production at source. Since detection of ultra-high energy (UHE) neutrinos is perhaps imminent, it is possible that such differences in spectral shapes will be tested in neutrino detectors in the near future. To that end, using the IceCube detector as an example, we show how our results translate to observable shower and muon-track event rates.

79 ASTRONOMY AND ASTROPHYSICS↗

Science with the space-based interferometer eLISA. III: probing the expansion of the universe using gravitational wave standard sirens

We investigate the capability of various configurations of the space interferometer eLISA to probe the late-time background expansion of the universe using gravitational wave standard sirens. We simulate catalogues of standard sirens composed by massive black hole binaries whose gravitational radiation is detectable by eLISA, and which are likely to produce an electromagnetic counterpart observable by future surveys. The main issue for the identification of a counterpart resides in the capability of obtaining an accurate enough sky localisation with eLISA. This seriously challenges the capability of four-link (2 arm) configurations to successfully constrain the cosmological parameters. Conversely, six-link (3 arm) configurations have the potential to provide a test of the expansion of the universe up to z ∼ 8 which is complementary to other cosmological probes based on electromagnetic observations only. In particular, in the most favourable scenarios, they can provide a significant constraint on H{sub 0} at the level of 0.5%. Furthermore, (Ω{sub M}, Ω{sub Λ}) can be constrained to a level competitive with present SNIa results. On the other hand, the lack of massive black hole binary standard sirens at low redshift allows to constrain dark energy only at the level of few percent.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining early and interacting dark energy with gravitational wave standard sirens: the potential of the eLISA mission

We perform a forecast analysis of the capability of the eLISA space-based interferometer to constrain models of early and interacting dark energy using gravitational wave standard sirens. We employ simulated catalogues of standard sirens given by merging massive black hole binaries visible by eLISA, with an electromagnetic counterpart detectable by future telescopes. We consider three-arms mission designs with arm length of 1, 2 and 5 million km, 5 years of mission duration and the best-level low frequency noise as recently tested by the LISA Pathfinder. Standard sirens with eLISA give access to an intermediate range of redshift 1 ∼< z ∼< 8, and can therefore provide competitive constraints on models where the onset of the deviation from ΛCDM (i.e. the epoch when early dark energy starts to be non-negligible, or when the interaction with dark matter begins) occurs relatively late, at z ∼< 6. If instead early or interacting dark energy is relevant already in the pre-recombination era, current cosmological probes (especially the cosmic microwave background) are more efficient than eLISA in constraining these models, except possibly in the interacting dark energy model if the energy exchange is proportional to the energy density of dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Standardized perioperative management in acute abdominal surgery: Swedish SMASH controlled study

Abstract Background Acute high-risk abdominal surgery is common, as are the attendant risks of organ failure, need for intensive care, mortality, or long hospital stay. This study assessed the implementation of standardized management. Methods A prospective study of all adults undergoing emergency laparotomy over an interval of 42 months (2018–2021) was undertaken; outcomes were compared with those of a retrospective control group. A new standardized clinical protocol was activated for all patients including: prompt bedside physical assessment by the surgeon and anaesthetist, interprofessional communication regarding location of resuscitation, elimination of unnecessary factors that might delay surgery, improved operating theatre competence, regular epidural, enhanced recovery care, and frequent early warning scores. The primary endpoint was 30-day mortality. Secondary endpoints were duration of hospital stay, need for intensive care, and surgical complications. Results A total of 1344 patients were included, 663 in the control group and 681 in the intervention group. The use of antibiotics increased (81.4 versus 94.7 per cent), and the time from the decision to operate to the start of surgery was reduced (3.80 versus 3.22 h) with use of the new protocol. Fewer anastomoses were performed (22.5 versus 16.8 per cent). The 30-day mortality rate was 14.5 per cent in the historical control group and 10.7 per cent in the intervention group (P = 0.045). The mean duration of hospital (11.9 versus 10.2 days; P = 0.007) and ICU (5.40 versus 3.12 days; P = 0.007) stays was also reduced. The rate of serious surgical complications (grade IIIb–V) was lower (37.6 versus 27.3 per cent; P = <0.001). Conclusion Standardized management protocols improved outcomes after emergency laparotomy.

Timan, Terje J.↗