Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source Term”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Maximum Likelihood Spectrum Decomposition for Isotope Identification and Quantification

A spectral decomposition method has been implemented to identify and quantify isotopic source terms in high-resolution gamma-ray spectroscopy in static geometry and shielding scenarios. Monte Carlo simulations were used to build the response matrix of a shielded high-purity germanium detector monitoring an effluent stream with a Marinelli configuration. The decomposition technique was applied to a series of calibration spectra taken with the detector using a multi-nuclide standard. These results are compared with decay-corrected values from the calibration certificate. For most nuclei in the standard ( 241 Am, 109 Cd, 137 Cs, and 60 Co), the deviations from the certificate values were generally no more than 6% with a few outliers as high as 10%. Furthermore, for 57 Co, the radionuclide with the lowest activity, the deviations from the standard reached as high as 25%, driven by the meager statistics in the calibration spectra. In addition, a complete treatment of error propagation for the technique is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Siting Samplers to Minimize Expected Time to Detection

We present a probabilistic approach to designing an indoor sampler network for detecting an accidental or intentional chemical or biological release, and demonstrate it for a real building. In an earlier paper, Sohn and Lorenzetti(1) developed a proof of concept algorithm that assumed samplers could return measurements only slowly (on the order of hours). This led to optimal detect to treat architectures, which maximize the probability of detecting a release. This paper develops a more general approach, and applies it to samplers that can return measurements relatively quickly (in minutes). This leads to optimal detect to warn architectures, which minimize the expected time to detection. Using a model of a real, large, commercial building, we demonstrate the approach by optimizing networks against uncertain release locations, source terms, and sampler characteristics. Finally, we speculate on rules of thumb for general sampler placement.

99 GENERAL AND MISCELLANEOUS↗

Pairing Directional Solar Inputs From Ray Tracing to Solar Receiver/Reactor Heat Transfer Models on Unstructured Meshes: Development and Case Studies

A novel method for pairing surface irradiation and volumetric absorption from Monte Carlo ray tracing to computational heat transfer models is presented. The method is well-suited to directionally and spatially complex concentrated radiative inputs (e.g., solar receivers and reactors). The method employs a generalized algorithm for directly mapping absorbed rays from a Monte Carlo ray tracing model to boundary or volumetric source terms in the computational mesh. The algorithm is compatible with unstructured, two and three-dimensional meshes with varying element shapes. Four case studies were performed on a directly irradiated, windowed solar thermochemical reactor model to validate the method. The method was shown to conserve energy and preserve spatial variation when mapping rays from a Monte Carlo ray tracing model to a computational heat transfer model in ansys fluent.

14 SOLAR ENERGY↗

Numerical Simulation of Container Breach and Airborne Release of Solids Due to Mechanical Insults

Throughout U.S. Department of Energy (DOE) complexes, safety engineers employ the five-factor formula to calculate the source term (ST) that includes parameters of airborne release fraction (ARF), respirable fraction (RF) and damage ratio (DR). Limited experimental data on fragmentation of solids, such as ceramic pellets (i.e., PuO2), and container breach due to mechanical insults (i.e., drop and forklift impact), can be supplemented by modeling and simulation using high fidelity computational tools to estimate these parameters. This paper presents the use of Sandia National Laboratories' SIERRA solid mechanics (SM) finite element code to investigate the behavior of the widely utilized waste container (such as 7A Drum) subject to a range of free fall impact and puncture scenarios. The resulting behavior of the container is assessed, and the estimates are presented for bounding DRs from calculated breach areas for the various accident conditions considered. This paper also describes a novel multiscale constitutive model recently implemented in SIERRA/SM that simulates the fracture of brittle materials such as PuO 2 and determines ARF during the fracture process. Furthermore, comparisons are made between model predictions and simple bench-top experiments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gamma dose rate estimation and operation management suggestions for decommissioning the reactor pressure vessel of HTR-PM

China is now designing and constructing a high temperature gas cooled reactor-pebble bed module (HTR-PM). In order to investigate the future decommissioning approach and evaluate possible radiation dose, gamma dose rate near the reactor pressure vessel was calculated for different cooling durations using QAD-CGA program. The source term of this calculation was provided by KORIGEN program. Based on the calculated results, the spatial distribution and temporal changes of gamma dose rate near reactor pressure vessel was systematically analyzed. A suggestion on planning decommissioning operation of reactor pressure vessel of HTRPM was given based on calculated dose rate and the Chinese Standard GB18871-2002. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimation of carbon 14 inventory in hull and end-piece wastes from Japanese commercial reprocessing operation

Hull and end-piece wastes generated from reprocessing plant operations are expected to be disposed of in a deep underground repository as Group 2 TRU wastes under the Japanese classification system. The activated metals that compose the spent fuel assemblies such as Zircaloy claddings and stainless steel nozzles are mixed and compressed after fuel dissolution, and then stuffed into stainless steel canisters. Carbon 14 is a typical activated product in the hulls and end-pieces and is mainly generated by the {sup 14}N(n,p){sup 14}C reaction. In the previous safety assessment of the TRU waste in Japan, the radionuclides inventory was calculated by ORIGEN-2 code. Some conservative assumptions and preliminary estimates were used in this calculation. For example, total radionuclides generated from a single type of fuel assembly (45 GWd/tU for a PWR unit), and the thickness of the Zircaloy oxide film on the hulls (80 μm) were both overestimated. The second assumption in particular has a large effect on exposure dose evaluation. Therefore, it is essential to have a realistic source term evaluation regarding such items as the C-14 inventory and its distribution to waste parts. In the present study, a C-14 inventory of the hull and end-piece wastes from the operation of a commercial reprocessing plant in Japan corresponding to 32,000 tU (16,000 tU in each BWR and PWR) was calculated. Analysis using individual irradiation conditions and fuel characteristics was conducted on 6 types of fuel assemblies for BWRs and 12 types for PWRs (4 pile types x 3 burnup limits). The oxide film thickness data for each fuel type cladding were obtained from the published literature. Activation calculations were performed by using ORIGEN-2 code. For the amount of spent assembly and other waste characteristics, representative values were assumed based on the published literature. As a preliminary experiment, C-14 in irradiated BWR claddings was measured and found to be consistent with the calculated activation. The total C-14 inventory was estimated as 4.46x10{sup 14} Bq, consisting of 2.58x10{sup 14} Bq for BWRs and 1.87x10{sup 14} Bq for PWRs, and is consistent with the safety assessment of 4.4x10{sup 14} Bq. However, the distribution of the C-14 inventory to hull oxide, which was estimated under the assumption of instantaneous radionuclide release in the safety assessment, decreased from 5.72x10{sup 13} Bq (13% of the total) in the previous assessment to 1.30x10{sup 13} Bq (2.9% of the total; consisting of 1.48x10{sup 12} for BWRs and 1.15x10{sup 13} for PWRs). In other words, the exposure dose peak is reduced to approximate 25% of its previous value due to the use of detailed oxide film data that the BWR cladding has a thin oxide film. Other instantaneous release components for C-14 such as the fuel residual were negligible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced simulation capability for environmental management - current status and future applications

The U.S. Department of Energy (US DOE) Office of Environmental Management (EM), Office of Soil and Groundwater (EM-12), is supporting development of the Advanced Simulation Capability for Environmental Management (ASCEM). ASCEM is a state-of-the-art scientific tool and approach that is currently aimed at understanding and predicting contaminant fate and transport in natural and engineered systems. ASCEM is a modular and open source high-performance computing tool. It will be used to facilitate integrated approaches to modeling and site characterization, and provide robust and standardized assessments of performance and risk for EM cleanup and closure activities. The ASCEM project continues to make significant progress in development of capabilities, with current emphasis on integration of capabilities in FY12. Capability development is occurring for both the Platform and Integrated Tool-sets and High-Performance Computing (HPC) multi-process simulator. The Platform capabilities provide the user interface and tools for end-to-end model development, starting with definition of the conceptual model, management of data for model input, model calibration and uncertainty analysis, and processing of model output, including visualization. The HPC capabilities target increased functionality of process model representations, tool-sets for interaction with Platform, and verification and model confidence testing. The integration of the Platform and HPC capabilities were tested and evaluated for EM applications in a set of demonstrations as part of Site Applications Thrust Area activities in 2012. The current maturity of the ASCEM computational and analysis capabilities has afforded the opportunity for collaborative efforts to develop decision analysis tools to support and optimize radioactive waste disposal. Recent advances in computerized decision analysis frameworks provide the perfect opportunity to bring this capability into ASCEM. This will allow radioactive waste disposal to be evaluated based on decision needs, such as disposal, closure, and maintenance. Decision models will be used in ASCEM to identify information/data needs, and model refinements that might be necessary to effectively reduce uncertainty in waste disposal decisions. Decision analysis models start with tools for framing the problem, and continue with modeling both the science side of the problem (for example, inventories, source terms, fate and transport, receptors, risk, etc.), and the cost side of the problem, which could include costs of implementation of any action that is chosen (e.g., for disposal or closure), and the values associated with those actions. The cost side of the decision problem covers economic, environmental and societal costs, which correspond to the three pillars of sustainability (economic, social, and environmental). These tools will facilitate stakeholder driven decision analysis to support optimal sustainable solutions in ASCEM. In this paper the current state of ASCEM is first described, followed by a description of the approach that will be taken to augment ASCEM for simulating fate and transport with tools that facilitate a top-down or systems level view of finding optimal, sustainable solutions to difficult environmental (including radioactive waste) problems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calculation of the nuclear material inventory in a sealed vault by 3D radiation mapping

The paper relates to the determination of the amount of nuclear material contained in a closed, concrete lined vault at the Aktau fast breeder reactor in Kazakhstan. This material had been disposed into the vault after examination in an experimental hot cell directly above the vault. In order to comply with IAEA Safeguards requirements it was necessary to determine the total quantities of nuclear materials - enriched uranium and plutonium - that were held with Kazakhstan. Although it was possible to determine the inventory of all of the accessible nuclear material - the quantity remaining in the vault was unknown. As part of the Global Threat Reduction Programme the UK Government funded a project to determine the inventory of these nuclear materials in this vault. This involved drilling three penetrations through the concrete lined roof of the vault; this enabled the placement of lights and a camera into the vault through two penetrations; while the third penetration enabled a lightweight manipulator arm to be introduced into the vault. This was used to provide a detailed 3D mapping of the dose rate within the vault and it also enabled the collection of samples for radionuclide analysis. The deconvolution of the 3D dose rate profile within the vault enabled the determination of the gamma emitting source distribution on the floor and walls of the vault. The samples were analysed to determine the fingerprint of those radionuclides producing the gamma dose - namely {sup 137}Cs and {sup 60}Co - to the nuclear materials. The combination of the dose rate source terms on the surfaces of the vault and the fingerprint then enabled the quantities of nuclear materials to be determined. The project was a major success and enabled the Kazakhstan Government to comply with IAEA Safeguards requirements. It also enabled the UK DECC Ministry to develop a technology of national (and international) use. Finally the technology was well received by IAEA Safeguards as an acceptable methodology for future studies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conceptual Design of Temperature-Controlled Fueled-Salt Irradiation Experiment to Support Demonstration of Advanced Nuclear Reactors

The irradiation testing of fuel-bearing molten salts is critical to supporting the development and demonstration of molten salt reactors (MSRs). These experiments can inform several important reactor design and safety parameters, including source term modeling, evolution of thermophysical properties with burn-up, and the degradation of structural materials under reactor relevant conditions. Idaho National Laboratory is designing an instrumented and heated high temperature molten salt-fueled irradiation capsule to study the behavior of the fuel salt during in-pile irradiation. This paper details the neutronics, thermal, and mechanical analysis performed to-date. Parametric studies are performed to assess a range of material, different experiment dimensions, two in-reactor positions, and the fuel enrichment used. Principal recommendations are to opt for a peripheral reactor position to alleviate neutronic constraints, a thin salt annulus to alleviate thermal constraints, and high-temperature alloys that provide additional safety margins.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of array-type prompt gamma measurement system for in vivo range verification in proton therapy

Purpose: In vivo range verification is one of the most important parts of proton therapy to fully utilize its benefits delivering high radiation dose to tumor, while sparing the normal tissue with the so-called Bragg peak. Currently, however, range verification method is not used in clinics. The purpose of the present study is to optimize and evaluate the configuration of an array-type prompt gamma measurement system on determining distal dose edge for in vivo range verification of proton therapy. Methods: To effectively measure the prompt gammas against the background gammas, the Monte Carlo simulations with the MCNPX code were employed in optimizing the configuration of the measurement system, and the Monte Carlo method was also used to understand the effect of the background gammas, mainly neutron capture gammas, in the measured gamma distribution. To reduce the effect of the background gammas, the optimized energy window of 4-10 MeV in measuring the prompt gammas was employed. A parameterized source was used to maximize computation speed in the optimization study. A simplified test measurement system, using only one detector moving from one measurement location to the next, was constructed and applied to therapeutic proton beams of 80-220 MeV. For accurate determination of the distal dose edge, the sigmoidal curve-fitting method was applied to the measured distributions of the prompt gammas, and then, the location of the half-value between the maximum and minimum value in the curve-fitting was determined as the distal dose edge and compared with the beam range assessed by the proton dose distribution. Results: The parameterized source term employed in optimization process improved the calculation speed by up to {approx}300 times. The optimization study indicates that an array-type measurement system with 3, 2, 2, and 150 mm for scintillator thickness, slit width, septal thickness, and slit length, respectively, can effectively measure the prompt gamma distributions minimizing the contribution of background gammas. The present results show that a few hundred counts of prompt gammas can be easily obtained by measuring 10 s at each measurement location for proton beams of {approx}4 nA. The distal dose edges determined by the prompt gamma distribution are 5.45, 14.73, and 27.74 cm for proton beams of 5.17 (80 MeV), 14.99 (150 MeV), and 27.38 (220 MeV) cm, respectively. Conclusions: The results show that the array-type measurement system can measure prompt gamma distributions from a therapeutic proton beam within a short measurement time, and that the distal dose edge can be determined within a few millimeters of error without using any sophisticated analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-578: MCEBRT, A Monte Carlo Code for External Beam Treatment Plan Verifications

Purpose: Present a new Monte Carlo code (MCEBRT) for patient-specific dose calculations in external beam radiotherapy. The code MLC model is benchmarked and real patient plans are re-calculated using MCEBRT and compared with commercial TPS. Methods: MCEBRT is based on the GEPTS system (Med. Phys. 29 (2002) 835–846). Phase space data generated for Varian linac photon beams (6 – 15 MV) are used as source term. MCEBRT uses a realistic MLC model (tongue and groove, rounded ends). Patient CT and DICOM RT files are used to generate a 3D patient phantom and simulate the treatment configuration (gantry, collimator and couch angles; jaw positions; MLC sequences; MUs). MCEBRT dose distributions and DVHs are compared with those from TPS in absolute way (Gy). Results: Calculations based on the developed MLC model closely matches transmission measurements (pin-point ionization chamber at selected positions and film for lateral dose profile). See Fig.1. Dose calculations for two clinical cases (whole brain irradiation with opposed beams and lung case with eight fields) are carried out and outcomes are compared with the Eclipse AAA algorithm. Good agreement is observed for the brain case (Figs 2-3) except at the surface where MCEBRT dose can be higher by 20%. This is due to better modeling of electron contamination by MCEBRT. For the lung case an overall good agreement (91% gamma index passing rate with 3%/3mm DTA criterion) is observed (Fig.4) but dose in lung can be over-estimated by up to 10% by AAA (Fig.5). CTV and PTV DVHs from TPS and MCEBRT are nevertheless close (Fig.6). Conclusion: A new Monte Carlo code is developed for plan verification. Contrary to phantombased QA measurements, MCEBRT simulate the exact patient geometry and tissue composition. MCEBRT can be used as extra verification layer for plans where surface dose and tissue heterogeneity are an issue.

60 APPLIED LIFE SCIENCES↗

SU-E-T-270: Diffusion Synthetic Acceleration for Linear Boltzmann Transport Equation

Purpose: Linear Boltzmann transport equation (LBTE) is as accurate as the Monte Carlo method (MC) for dose calculation in photon/particle therapy (LBTE is a deterministic and Eulerian formulation and MC is a statistical and Lagrangian description). An advantage of LBTE is that numerous acceleration techniques can be utilized for acceleration. This work is to explore the acceleration of LBTE via diffusion synthetic acceleration (DSA). Methods: For simplicity, two-dimensional, steady-state, and within-group LBTE is considered with two angular dimensions and two spatial dimensions. The discrete ordinate method is developed for solving this integro-differential equation. The angular variables are discretized using a level-symmetric quadrature set on the unit sphere. The spatial variables are discretized on the structured grid based on the diamond scheme. The source-iteration method (SI) is used to solve the discretized system.Since SI is slow in optically thick and highly scattering regime. DSA is developed to accelerate SI. The motivation for DSA is that diffusion equation (DE) is a good approximation of LBTE in the above regime. However, DE is much cheaper than LBTE computationally since DE only involves spatial variables. Thus, in each DSA iteration, DSA adds to the SI step a computationally-negligible DE step, i.e., to first solve DE with the SI residual as source term, and then compensate the SI solution with DE solution. Results: DSA was benchmarked and compared with SI. The difference between two methods was within 0.12% which verifies the accuracy of DSA, while DSA demonstrated the great advantage in speed, e.g., the reduction of iteration number to 6% and 4% respectively for cases with 100 and 1,000 scattering-absorption ratio that commonly occur in clinical dose calculation. Conclusion: DSA has been developed as one of many possible means for accelerating the numerical solver of LBTE for dose calculation. The authors were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

60 APPLIED LIFE SCIENCES↗

SU-F-207-05: Excess Heat Corrections in a Prototype Calorimeter for Direct Realization of CT Absorbed Dose to Phantom

Purpose: To reconcile air kerma and calorimetry measurements in a prototype calorimeter for obtaining absorbed dose in diagnostic CT beams. While corrections for thermal artifacts are routine and generally small in calorimetry of radiotherapy beams, large differences in relative stopping powers of calorimeter materials at the lower energies typical of CT beams greatly magnify their effects. Work-to-date on the problem attempts to reconcile laboratory measurements with modeling output from Monte Carlo and finite-element analysis of heat transfer. Methods: Small thermistor beads were embedded in a polystyrene (PS) core element of 1 cm diameter, which was inserted into a cylindrical HDPE phantom of 30 cm diameter and subjected to radiation in a diagnostic CT x-ray imaging system. Resistance changes in the thermistors due to radiation heating were monitored via lock-in amplifier. Multiple 3-second exposures were recorded at 8 different dose-rates from the CT system, and least-squares fits to experimental data were compared to an expected thermal response obtained by finite-element analysis incorporating source terms based on semi-empirical modeling and Monte Carlo simulation. Results: Experimental waveforms exhibited large thermal artifacts with fast time constants, associated with excess heat in wires and glass, and smaller steps attributable to radiation heating of the core material. Preliminary finite-element analysis follows the transient component of the signal qualitatively, but predicts a slower decay of temperature spikes. This was supplemented by non-linear least-squares fits incorporating semi-empirical formulae for heat transfer, which were used to obtain dose-to-PS in reasonable agreement with the output of Monte Carlo calculations that converts air kerma to absorbed dose. Conclusion: Discrepancies between the finite-element analysis and our experimental data testify to the very significant heat transfer correction required for absorbed dose calorimetry of diagnostic CT beams. The results obtained here are being used to refine both simulations and design of calorimeter core components.

60 APPLIED LIFE SCIENCES↗

Concerning the width of spark channels with different polarities in submicrosecond sliding discharges in noble gases

Previously, the parameters of submicrosecond (with a duration of <200 ns) multichannel high-current discharges sliding along a ceramic surface in Ne, Ar, and Xe were studied only for the negative polarity of the applied voltage. The experimental data indicate that the channels expand in the transverse direction mainly due to electron drift from the channel surface layer under the action of the electric field perpendicular to the channel axis and subsequent gas ionization by these electrons. To investigate mechanisms for the channel development in a sliding discharge-in particular, to determine the contribution of electron drift-it is necessary to carry out experiments similar to those performed earlier for the opposite polarity of the applied voltage. Here, the results of measurements of the widths of the spark channels of negativeand positive-polarity sliding discharges excited in Ne, Ar, and Xe at pressures of 30 and 100 kPa are presented and discussed. It is shown that, depending on the pressure and sort of gas, the averaged optical width of positive-polarity channels is smaller by a factor of 1.27-1.60 than that of negative-polarity channels. The experimental data are analyzed using the theory of propagation of ionization waves with different polarities in gases. Analysis has shown that electron diffusion contributes insignificantly to channel expansion and that, for both polarities, the channel expansion rate exceeds the electron drift velocity in the transverse electric field near the channel. In the framework of the so-called approximation of nonlocalized initial conditions, the measured ratio between of the widths of negativeand positive-polarity channels and their relation to the electron mobility are explained by the channel expansion governed by both electron drift and primary free electrons produced by a short-term source in a narrow region ahead of the front of the expansion wave. Numerical simulations show that the width of this region is comparable with that of the wave front and is more than one order of magnitude smaller than the observed channel radius. Gas photoionization by the channel radiation can serve as a source of primary electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal explicit strong-stability-preserving general linear methods.

This paper constructs strong-stability-preserving general linear time-stepping methods that are well suited for hyperbolic PDEs discretized by the method of lines. These methods generalize both Runge-Kutta (RK) and linear multistep schemes. They have high stage orders and hence are less susceptible than RK methods to order reduction from source terms or nonhomogeneous boundary conditions. A global optimization strategy is used to find the most efficient schemes that have low storage requirements. Numerical results illustrate the theoretical findings.

97 MATHEMATICS AND COMPUTING↗

A Fourth-Order Embedded Boundary Finite Volume Method for the Unsteady Stokes Equations with Complex Geometries

A fourth-order finite volume embedded boundary (EB) method is presented for the unsteady Stokes equations. The algorithm represents complex geometries on a Cartesian grid using EB, employing a technique to mitigate the ``small cut-cell"" problem without mesh modifications, cell merging, or state redistribution. Spatial discretizations are based on a weighted least-squares technique that has been extended to fourth-order operators and boundary conditions, including an approximate projection to enforce the divergence-free constraint. Solutions are advanced in time using a fourth-order additive implicit-explicit Runge-Kutta method, with the viscous and source terms treated implicitly and explicitly, respectively. Formal accuracy of the method is demonstrated with several grid convergence studies, and results are shown for an application with a complex bio-inspired material. In conclusion, the developed method achieves fourth-order accuracy and is stable despite the pervasive small cells arising from complex geometries.

97 MATHEMATICS AND COMPUTING↗

Seismic Waves, 4th order accurate

SW4 is a program for simulating seismic wave propagation on parallel computers. SW4 colves the seismic wave equations in Cartesian corrdinates. It is therefore appropriate for regional simulations, where the curvature of the earth can be neglected. SW4 implements a free surface boundary condition on a realistic topography, absorbing super-grid conditions on the far-field boundaries, and a kinematic source model consisting of point force and/or point moment tensor source terms. SW4 supports a fully 3-D heterogeneous material model that can be specified in several formats. SW4 can output synthetic seismograms in an ASCII test format, or in the SAC finary format. It can also present simulation information as GMT scripts, whixh can be used to create annotated maps. Furthermore, SW4 can output the solution as well as the material model along 2-D grid planes.

Source record↗

MUFFSgenMC: An Open Source MUon Flexible Framework for Spectral GENeration for Monte Carlo Applications

A cosmic ray Muon Flexible Framework for Spectral GENeration for Monte Carlo Applications (MUFFSgenMC) has been developed to support state-of-the-art cosmic ray muon tomographic applications. The flexible framework allows for easy and fast creation of source terms for popular Monte Carlo applications like GEANT4 and MCNP. This code framework simplifies the process of simulations used for cosmic ray muon tomography.

Chatzidakis, Stylianos↗