Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Astigmatism-corrected Czerny-Turner imaging spectrometer for broadband spectral simultaneity

A low-cost, broadband, astigmatism-corrected Czerny-Turner arrangement with a fixed plane grating is proposed. A wedge cylindrical lens is used to correct astigmatism over a broadband spectral range. The principle and method of astigmatism correction are described in detail. We compare the performance of this modified Czerny-Turner arrangement with that of the traditional Czerny-Turner arrangement by using a practical Czerny-Turner imaging spectrometer example.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Intensity-Value Corrections for Integrating Sphere Measurements of Solid Samples Measured Behind Glass

Accurate and calibrated directional-hemispherical reflectance spectra of solids are important for both in situ and remote sensing. Many solids are in the form of powders or granules and to measure their diffuse reflectance spectra in the laboratory, it is often necessary to place the samples behind a transparent medium such as glass for the ultraviolet (UV), visible, or near-infrared spectral regions. Using both experimental methods and a simple optical model, we demonstrate that glass (fused quartz in our case) leads to artifacts in the reflectance values. We report our observations that the measured reflectance values, for both hemispherical and diffuse reflectance, are distorted by the additional reflections arising at the air–quartz and sample–quartz interfaces. The values are dependent on the sample reflectance and are offset in intensity in the hemispherical case, leading to measured values up to ~6% too high for a 2% reflectance surface, ~3.8% too high for 10% reflecting surfaces, approximately correct for 40–60% diffuse-reflecting surfaces, and ~1.5% too low for 99% reflecting Spectralon® surfaces. For the case of diffuse-only reflectance, the measured values are uniformly too low due to the polished glass, with differences of nearly 6% for a 99% reflecting matte surface. The deviations arise from the added reflections from the quartz surfaces, as verified by both theory and experiment, and depend on sphere design. Finally, empirical correction factors were implemented into post-processing software to redress the artifact for hemispherical and diffuse reflectance data across the 300–2300 nm range.

Visible near-infrared spectroscopy, integrating sp↗

Annual Report on the Activities and Publications of the DHS-DNDO-NTNFC-Sponsored Post-doctoral Fellow at Los Alamos National Laboratory

This report is a summary update on the projects Magen Coleman is working on as a postdoctoral fellow funded by DHS. These research projects are designed to explore different radioanalytical facets of nuclear forensics, including destructive and non-destructive analysis, chronometry measurements and modeling, spectral analysis, and actinide separations. Method development and instrumental analysis are integral parts of these projects, along with strong radiochemical knowledge. The current projects discussed here include method development for 232U analysis, the assembly of a gamma mapping system, the testing of neutron bubble detectors for neutron spectrometry, and continued work on the chronometry of plutonium and uranium materials. This report documents the work that has been performed since April 2011.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Annual Report X-GAMMA: Revealing the Nuclear Fingerprint with Cryogenic Detectors

Technical work in the area of gamma-ray spectroscopy based on ultra-high resolution microcalorimeter spectrometers has focused on three areas: (1) In depth study of the sources of systematic uncertainty, (2) hardware upgrades to increase the stability and speed of spectrometer operation, and (3) measuring plutonium-containing SNM samples to test the hardware system and to inform further development of our spectral data analysis tools and methods.

47 OTHER INSTRUMENTATION↗

Sediment Mineralogy Data Review for the Hanford Central Plateau

The compendium of Hanford site sediment mineralogy data provided in this report was initiated in 2012 to support flux mitigation technologies and real-time monitoring that could limit contaminant fluxes to the groundwater in the Central Plateau. Recent efforts in advancing spectral induced polarization as a method for monitoring contaminant transformations for active biogeochemical remedies have underscored the need for a published compendium of sediment characterization data. Although the data are primarily focused on the mineralogical composition of Hanford sediments, other soil measurements such as particle size distribution such as particle size distribution and carbon content are provided. The data have been reproduced from the original reports and are provided here for information only (FIO).

58 GEOSCIENCES↗

SPARC-X: Quantum simulations at extreme scale - reactive dynamics from first principles

We have developed the massively parallel electronic structure code SPARC-X: a computational framework for performing Kohn-Sham Density Functional Theory (DFT) calculations that can scale linearly with the number of atoms in the system, while being able to leverage petascale and emerging exascale parallel computers to study chemical phenomena at unprecedented length and time scales. SPARC-X exploits a recent breakthrough in electronic structure methodologies: systematically improvable, strictly local, orthonormal, discontinuous real-space bases that efficiently and systematically capture the local chemistry of the system. With further adaptation using new machine-learning techniques and the use of the massively parallel Spectral Quadrature (SQ) electronic structure method, the algorithmic complexity and prefactor associated with DFT calculations involving semilocal as well as hybrid functionals are dramatically reduced. Using petascale computational resources, SPARC-X enables quantum mechanical simulations at length and time scales previously accessible only by empirical approaches, e.g., 1,000,000 atoms for a few picoseconds using semilocal functionals or 1,000 atoms for a few picoseconds using hybrid functionals. Using exascale resources, the sizes and times targeted are two orders of magnitude larger. Such a capability has applications in a wide variety of chemical sciences, including reactive interfaces where large length- and/or long time-scales are needed and traditional force fields fail. This is particularly important in dynamic catalysis, where bond breaking and formation must be understood in detail. We developed, tested, and employed the SPARC-X framework to understand the photocatalytic properties of TiO 2 nanoparticles, revealing finite size effects that cannot be captured with standard model systems or functionals. This integrated development and application strategy ensures that SPARC-X remains a robust, efficient, and scalable software package for quantum simulations on current petascale and emerging exascale computing resources.

97 MATHEMATICS AND COMPUTING↗

The Optical and Infrared Are Connected

Galaxies are often modeled as composites of separable components with distinct spectral signatures, implying that different wavelength ranges are only weakly correlated. They are not. We present a data-driven model that exploits subtle correlations between physical processes to accurately predict infrared (IR) Wide-field Infrared Survey Explorer (WISE) photometry from a neural summary of optical Sloan Digital Sky Survey spectra. The model achieves accuracies of $χ^{2}_{N} ≈ 1$ for all photometric bands in WISE, as well as good colors. We are able to tightly constrain typically IR-derived properties, e.g., the bolometric luminosities of active galactic nuclei (AGN) and dust parameters such as q PAH . We also test whether current spectral energy distribution (SED) fitting methods reproduce such panchromatic relations, but find their predictions biased and overconfident, likely due to model misspecification, with correlated biases in star-formation rates (SFRs) and AGN luminosities being most evident. To help improve SED models, we determine which features of the optical spectrum are responsible for our improved predictions, and identify several lines (Ca II , Sr II , Fe I , [O II ], and Hα), which point to the complex chronology of star formation and chemical enrichment being incorrectly modeled.

Jespersen, Christian Kragh [Princeton Univ., NJ (U↗

Vertical column dual-comb spectroscopy to a TBS

Open-path dual-frequency-comb spectroscopy (DCS) is a broadband, high spectral resolution, and high precision method for measuring gas concentrations over kilometer-scale paths. It has been used for detection and quantification of emissions of pollutants, hazardous gasses, and greenhouse gasses (GHGs). DCS has been shown to measure trace-gas mixing ratios with 0.14%-0.4% agreement between instruments. To achieve high signal-to-noise ratios (SNRs) with DCS, comb light is targeted onto a retroreflector at the end of the measurement path, which returns the signal to a detector co-located with the launch signal. Installing the retroreflector on a mobile platform such as a balloon or unmanned aerial vehicle (UAV) extends the capabilities of DCS by enabling variable path lengths, greater mobility, and access to higher altitudes. Mobile-target DCS has many uses in plume and leak detection, emissions modeling, and planetary boundary layer (PBL) studies. It is a promising method for observing vertical distributions of GHGs and mixing processes in the PBL, which are difficult to measure but important for pollution and climate monitoring as well as for understanding transport of gasses through the atmosphere. Tethered balloons are an intriguing platform because they enable longer flight durations and higher altitudes than easily obtainable with a UAV and thus allow for column measurements up to and above the PBL. New measurements completed in October/November 2024 reach the highest altitudes above ground level yet achieved by mobile-target DCS. For these measurements, the retroreflector was mounted on a 7 m diameter tethered helium balloon. An actively tracking gimbal on the ground holds the DCS launch telescope and keeps the 5 cm beam pointed onto the retroreflector while the balloon is lifted, lowered, and moved by wind and turbulence.

atmosphere↗

VLASOV EIGENFUNCTION ANALYSIS OF SPACE-CHARGE AND BEAM-BEAM EFFECTS

Space-charge and beam-beam interaction affect both incoherent and coherent motion of particles potentially leading to instabilities and deterioration of the beam parameters. An overview of these phenomena will be given with an emphasis on the observable spectral characteristics and the mitigation methods of their harmful effects.

43 PARTICLE ACCELERATORS↗

Radiative Heat Transport and Optical Characterization of High Temperature Molten Salts

The goal of this project was to advance the field of molten fluoride radiative heat transfer (RHT), through optical property measurements, heat transfer loop construction and operation, and computational fluid dynamics simulations. The following outcomes have been accomplished. A comprehensive review has been conducted to compile all available RHT-relevant optical absorption data for molten fluorides. The various measurement methods have also been compiled and critiqued. Thermal emission measurement methods have been refined and documented. A unique thermal emissivity measurement facility has been constructed and used to measure the emissivity of flowing FLiBe-exposed SS316 samples. A slight increase has been observed in the emissivity compared to unexposed SS316. A dual reflectance-emission setup was partially demonstrated for the purpose of molten fluoride absorption measurement. Preliminary infrared edge data for FLiNaK was obtained. A visible near-infrared (NIR) measurement setup has been constructed and will be used to measure absorption of corrosion products in FLiBe. A new multi-band thermal radiation method using blackbody-weighted spectral bands for the absorption-coefficient was deployed to investigate the thermal performance of the UW Natural Circulation FLiBe Loop under various power levels and operating conditions. The results showed an increasing and decreasing trend in the overall heat transfer with optical thickness with a maximum at optical thickness τ D ≈Ο(1). A forced convection FLiBe loop was constructed for the purpose of studying corrosion and thermal hydraulic phenomena. A vertical cantilever pump is used to achieve up to 5 gpm and 5 m/s flow velocity in hot and cold test sections. A methodology has been established for modeling radiative heat transfer (RHT) in molten salt coolants for the purpose of quantifying the contribution of thermal radiation in conditions relevant to FHR or MSR systems. The comparison between the results obtained for forced and mixed convection showed that in the studied ranges of optical thickness, the maximum effect of RHT on overall heat transfer was 60% improvement observed at z/D = 250 for forced convection; whereas for mixed convection, that value was higher at 170% observed at z/D = 30. The highest effect of RHT on the overall energy distribution was observed at τ D ≈3.4. Negligible effect (<20%) was observed above τ D =18 and below τ D ≈0.002. A CFD code-to-code comparison was conducted using COMSOL Multiphysics at UW-Madison and STAR-CCM at MIT, for a forced and mixed convection laminar flow for a grey medium in a vertical heated using both COMSOL Multiphysics at UW-Madison and STAR-CCM at MIT. The relative error was the largest at τ D =40 for the radiative heat flux, bulk temperature, and Nusselt number. On the other hand, the relative error was the least at τ D =0.002 for the conductive heat flux, bulk temperature, and Nusselt number.

Anderson, Mark↗

Improved CdTe PLR Estimates: Self-Shading and Spectral Mismatch

The RdTools year-on-year method of estimating performance loss rate (PLR) employs a simple normalization to remove the confounding effect of irradiance and temperature variation. However, the normalization's assumption that PV production scales linearly with in-plane broadband irradiance is a worse approximation for CdTe and other technologies with larger spectral sensitivities than it is for the more common c-Si technology. Additionally, CdTe systems using single-axis trackers (-20% of installed US utility-scale capacity) are subject to self-shading in the morning and afternoon, introducing another nonlinearity between PV output and broadband irradiance. Ignoring these effects may subject the estimated PLR to increased uncertainty, and perhaps bias, depending on the character of their short- and long-term variability. In this work we show that including self-shading and spectral mismatch models in the normalization for tracking CdTe systems can result not only in tighter PLR confidence intervals but different median PLRs as well. The shading and spectral models are kept simple to maintain consistency with the RdTools ethos of not requiring detailed system metadata or unusual measurements.

CdTe↗

Passive millimeter wave spectrometer for remote detection of chemical plumes

Systems and methods for the passive measurement of spectral lines from the absorption or emission by polar molecules. The system includes mmW front-end assembly, back-end electronics, and data acquisition hardware and software was assembled. The method relates to methods for processing multi-channel radiometric data from passive mmW detection systems.

Gopalsami, Nachappa↗

Passive millimeter wave spectrometer for remote detection of chemical plumes

Systems and methods for the passive measurement of spectral lines from the absorption or emission by polar molecules. The system includes mmW front-end assembly, back-end electronics, and data acquisition hardware and software was assembled. The method relates to methods for processing multi-channel radiometric data from passive mmW detection systems.

Gopalsami, Nachappa↗

Performance analysis of fully explicit and fully implicit solvers within a spectral element shallow-water atmosphere model

In this study, explicit Runge–Kutta methods and implicit multistep methods utilizing a Newton–Krylov nonlinear solver are evaluated for a range of configurations of the shallow-water dynamical core of the spectral element community atmosphere model to evaluate their computational performance. These configurations are designed to explore the attributes of each method under different but relevant model usage scenarios including varied spectral order within an element, static regional refinement, and scaling to the largest problem sizes. This analysis is performed within the shallow-water dynamical core option of a full climate model code base to enable a wealth of simulations for study, with the aim of informing solver development within the more complete hydrostatic dynamical core used for climate research. The limitations and benefits to using explicit versus implicit methods, with different parameters and settings, are discussed in light of the trade-offs with Message Passing Interface (MPI) communication and memory and their inherent efficiency bottlenecks. Given the performance behavior across the configurations analyzed here, the recommendation for future work using the implicit solvers is conditional based on scale separation and the stiffness of the problem. For the regionally refined configurations, the implicit method has about the same efficiency as the explicit method, without considering efficiency gains from a preconditioner. The potential for improvement using a preconditioner is greatest for higher spectral order configurations, where more work is shifted to the linear solver. Finally, initial simulations with OpenACC directives to utilize a Graphics Processing Unit (GPU) when performing function evaluations show improvements locally, and that overall gains are possible with adjustments to data exchanges.

58 GEOSCIENCES↗

Lineal energy calibration of mini tissue-equivalent gas-proportional counters (TEPC)

Mini TEPCs are cylindrical gas proportional counters of 1 mm or less of sensitive volume diameter. The lineal energy calibration of these tiny counters can be performed with an external gamma-ray source. However, to do that, first a method to get a simple and precise spectral mark has to be found and then the keV/{mu}m value of this mark. A precise method (less than 1% of uncertainty) to identify this markis described here, and the lineal energy value of this mark has been measured for different simulated site sizes by using a {sup 137}Cs gamma source and a cylindrical TEPC equipped with a precision internal {sup 244}Cm alpha-particle source, and filled with propane-based tissue-equivalent gas mixture. Mini TEPCs can be calibrated in terms of lineal energy, by exposing them to {sup 137}Cesium sources, with an overall uncertainty of about 5%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FELIX-2.0: New version of the finite element solver for the time dependent generator coordinate method with the Gaussian overlap approximation

The time-dependent generator coordinate method (TDGCM) is a powerful method to study the largeamplitude collective motion of quantum many-body systems such as atomic nuclei. Under the GaussianOverlap Approximation (GOA), the TDGCM leads to a local, time-dependent Schrödinger equation in amulti-dimensional collective space. In this paper, we present the version 2.0 of the code FELIX that solvesthe collective Schrödinger equation in a finite element basis. This new version features: (i) the ability tosolve a generalized TDGCM+GOA equation with a metric term in the collective Hamiltonian, (ii) supportfor new kinds of finite elements and different types of quadrature to compute the discretized Hamiltonianand overlap matrices, (iii) the possibility to leverage the spectral element scheme, (iv) an explicit Krylovapproximation of the time propagator for time integration instead of the implicit Crank–Nicolson methodimplemented in the first version, (v) an entirely redesigned workflow. We benchmark this release on ananalytic problem as well as on realistic two-dimensional calculations of the low-energy fission of240Puand256Fm. Low to moderate numerical precision calculations are most efficiently performed with simplexelements with a degree 2 polynomial basis. Higher precision calculations should instead use the spectralelement method with a degree 4 polynomial basis. We emphasize that in a realistic calculation of fissionmass distributions of240Pu, FELIX-2.0 is about 20 times faster than its previous release (within a numericalprecision of a few percents).

Regnier, D.↗

Methods and results of studies of the radiation spectra of megampere Z-pinches at the angara-5-1 facility

Methods and results of studies of the radiation spectra of high-current Z-pinches with different elemental compositions are presented. To examine a wide spectral range (E{sub hν} = 30–3000 eV), two diagnostics tools were used—a transmission grating and a reflecting mica crystal. The radiation characteristics of the pinch are determined by its elemental composition. For currents of 2–3 MA and low-Z elements (aluminum), the hard end of the radiation spectrum is represented by spectral lines with clearly pronounced K lines, while for high-Z elements (tungsten), the spectrum lies in the softer photon energy range and is quasi-continuous. Two methods of spectrum processing were used to determine the plasma parameters. The parameters of aluminum plasma were traditionally determined from the intensity ratios of the K lines taking into account the plasma transparency for these lines. The spectra of tungsten plasma were compared with the results of computer simulations of pinch compression with allowance for both magnetohydrodynamic and plasma radiation processes. The applicability of these methods of spectral analysis is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗