Search NASA⌕ Search

SEARCH · Search NASA

Results for “Strategy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Chemical copatterning strategies using azlactone-based block copolymers

Interfaces can be modified with azlactone-functional polymers in order to manipulate the chemical surface reactivity. Azlactone groups are highly reactive toward amine, thiol, and alcohol nucleophiles, providing a versatile coupling chemistry for secondary surface modification. Azlactone-based surface polymers have been explored in numerous applications, including chemical and biological capture, sensing, and cell culture. These applications often require that the polymer is copatterned within a chemically or biologically inert background; however, common fabrication methods degrade azlactone groups during processing steps or result in polymer films with poorly controlled thicknesses. Here, the authors develop fabrication strategies using parylene lift-off and interface-directed assembly methods to generate microscale patterns of azlactone-based block copolymer in chemically or biologically inert backgrounds. The functionality of azlactone groups was preserved during fabrication, and patterned films appeared as uniform, 80–120 nm brushlike films. The authors also develop a patterning approach that uses a novel microcontact stamping method to generate cross-linked, three-dimensional structures of azlactone-based polymers with controllable, microscale thicknesses. The authors identify the benefits of each approach and expect these polymers and patterning strategies to provide a versatile toolbox for developing synthetic interfaces with tuned chemical and physical features for sensing, cell culture, or material capture applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Clinical development of a failure detection-based online repositioning strategy for prostate IMRT--Experiments, simulation, and dosimetry study

Purpose: To implement and evaluate clinic-ready adaptive imaging protocols for online patient repositioning (motion tracking) during prostate IMRT using treatment beam imaging supplemented by minimal, as-needed use of on-board kV. Methods: The authors examine the two-step decision-making strategy: (1) Use cine-MV imaging and online-updated characterization of prostate motion to detect target motion that is potentially beyond a predefined threshold and (2) use paired MV-kV 3D localization to determine overthreshold displacement and, if needed, reposition the patient. Two levels of clinical implementation were evaluated: (1) Field-by-field based motion correction for present-day linacs and (2) instantaneous repositioning for new-generation linacs with capabilities of simultaneous MV-kV imaging and remote automatic couch control during treatment delivery. Experiments were performed on a Varian Trilogy linac in clinical mode using a 4D motion phantom programed with prostate motion trajectories taken from patient data. Dosimetric impact was examined using a 2D ion chamber array. Simulations were done for 536 trajectories from 17 patients. Results: Despite the loss of marker detection efficiency caused by the MLC leaves sometimes obscuring the field at the marker's projected position on the MV imager, the field-by-field correction halved (from 23% to 10%) the mean percentage of time that target displacement exceeded a 3 mm threshold, as compared to no intervention. This was achieved at minimal cost in additional imaging (average of one MV-kV pair per two to three treatment fractions) and with a very small number of repositionings (once every four to five fractions). Also with low kV usage ({approx}2/fraction), the instantaneous repositioning approach reduced overthreshold time by more than 75% (23% to 5%) even with severe MLC blockage as often encountered in current IMRT and could reduce the overthreshold time tenfold (to <2%) if the MLC blockage problem were relieved. The information acquired for repositioning using combined MV-kV images was found to have submillimeter accuracy. Conclusions: This work demonstrated with a current clinical setup that substantial reduction of adverse targeting effects of intrafraction prostate motion can be realized. The proposed adaptive imaging strategy incurs minimal imaging dose to the patient as compared to other stereoscopic imaging techniques.

60 APPLIED LIFE SCIENCES↗

Sampling strategies for subsampled segmented EPI PRF thermometry in MR guided high intensity focused ultrasound

Purpose: To investigate k-space subsampling strategies to achieve fast, large field-of-view (FOV) temperature monitoring using segmented echo planar imaging (EPI) proton resonance frequency shift thermometry for MR guided high intensity focused ultrasound (MRgHIFU) applications. Methods: Five different k-space sampling approaches were investigated, varying sample spacing (equally vs nonequally spaced within the echo train), sampling density (variable sampling density in zero, one, and two dimensions), and utilizing sequential or centric sampling. Three of the schemes utilized sequential sampling with the sampling density varied in zero, one, and two dimensions, to investigate sampling the k-space center more frequently. Two of the schemes utilized centric sampling to acquire the k-space center with a longer echo time for improved phase measurements, and vary the sampling density in zero and two dimensions, respectively. Phantom experiments and a theoretical point spread function analysis were performed to investigate their performance. Variable density sampling in zero and two dimensions was also implemented in a non-EPI GRE pulse sequence for comparison. All subsampled data were reconstructed with a previously described temporally constrained reconstruction (TCR) algorithm. Results: The accuracy of each sampling strategy in measuring the temperature rise in the HIFU focal spot was measured in terms of the root-mean-square-error (RMSE) compared to fully sampled “truth.” For the schemes utilizing sequential sampling, the accuracy was found to improve with the dimensionality of the variable density sampling, giving values of 0.65 °C, 0.49 °C, and 0.35 °C for density variation in zero, one, and two dimensions, respectively. The schemes utilizing centric sampling were found to underestimate the temperature rise, with RMSE values of 1.05 °C and 1.31 °C, for variable density sampling in zero and two dimensions, respectively. Similar subsampling schemes with variable density sampling implemented in zero and two dimensions in a non-EPI GRE pulse sequence both resulted in accurate temperature measurements (RMSE of 0.70 °C and 0.63 °C, respectively). With sequential sampling in the described EPI implementation, temperature monitoring over a 192 × 144 × 135 mm{sup 3} FOV with a temporal resolution of 3.6 s was achieved, while keeping the RMSE compared to fully sampled “truth” below 0.35 °C. Conclusions: When segmented EPI readouts are used in conjunction with k-space subsampling for MR thermometry applications, sampling schemes with sequential sampling, with or without variable density sampling, obtain accurate phase and temperature measurements when using a TCR reconstruction algorithm. Improved temperature measurement accuracy can be achieved with variable density sampling. Centric sampling leads to phase bias, resulting in temperature underestimations.

42 ENGINEERING↗

Selective robust optimization: A new intensity-modulated proton therapy optimization strategy

Purpose: To develop a new robust optimization strategy for intensity-modulated proton therapy as an important step in translating robust proton treatment planning from research to clinical applications. Methods: In selective robust optimization, a worst-case-based robust optimization algorithm is extended, and terms of the objective function are selectively computed from either the worst-case dose or the nominal dose. Two lung cancer cases and one head and neck cancer case were used to demonstrate the practical significance of the proposed robust planning strategy. The lung cancer cases had minimal tumor motion less than 5 mm, and, for the demonstration of the methodology, are assumed to be static. Results: Selective robust optimization achieved robust clinical target volume (CTV) coverage and at the same time increased nominal planning target volume coverage to 95.8%, compared to the 84.6% coverage achieved with CTV-based robust optimization in one of the lung cases. In the other lung case, the maximum dose in selective robust optimization was lowered from a dose of 131.3% in the CTV-based robust optimization to 113.6%. Selective robust optimization provided robust CTV coverage in the head and neck case, and at the same time improved controls over isodose distribution so that clinical requirements may be readily met. Conclusions: Selective robust optimization may provide the flexibility and capability necessary for meeting various clinical requirements in addition to achieving the required plan robustness in practical proton treatment planning settings.

60 APPLIED LIFE SCIENCES↗

SU-E-T-13: A Comparative Dosimetric Study On Radio-Dynamic Therapy for Pelvic Cancer Treatment: Strategies for Bone Marrow Dose and Volume Reduction

Purpose: Radio-dynamic therapy (RDT) is a potentially effective modality for local and systemic cancer treatment. Using RDT, the administration of a radio-sensitizer enhances the biological effect of high-energy photons. Although the sensitizer uptake ratio of tumor to normal tissue is normally high, one cannot simply neglect its effect on critical structures. In this study, we aim to explore planning strategies to improve bone marrow sparing without compromising the plan quality for RDT treatment of pelvic cancers. Methods: Ten cervical and ten prostate cancer patients who previously received radiotherapy at our institution were selected for this study. For each patient, nine plans were created using the Varian Eclipse treatmentplanning-system (TPS) with 3D-CRT, IMRT, and VMAT delivery techniques containing various gantry angle combinations and optimization parameters (dose constraints to the bone marrow). To evaluate the plans for bone marrow sparing, the dose-volume parameters V5, V10, V15, V20, V30, and V40 for bone marrow were examined. Effective doseenhancement factors for the sensitizer were used to weigh the dose-volume histograms for various tissues from individual fractions. Results: The planning strategies had different impacts on bone marrow sparing for the cervical and prostate cases. For the cervical cases, provided the bone marrow constraints were properly set during optimization, the dose to bone marrow sparing was found to be comparable between different IMRT and VMAT plans regardless of the gantry angle selection. For the prostate cases, however, careful selection of gantry angles could dramatically improve the bone marrow sparing, although the dose distribution in bone marrow was clinically acceptable for all prostate plans that we created. Conclusion: For intensity-modulated RDT planning for cervical cancer, planners should set bone marrow constraints properly to avoid any adverse damage, while for prostate cancer one can carefully select gantry angles to improve bone marrow sparing when necessary.

60 APPLIED LIFE SCIENCES↗

WE-G-BRD-07: Automated MR Image Standardization and Auto-Contouring Strategy for MRI-Based Adaptive Brachytherapy for Cervix Cancer

Purpose: MRI-based adaptive brachytherapy (ABT) is an emerging treatment modality for patients with gynecological tumors. However, MR image intensity non-uniformities (IINU) can vary from fraction to fraction, complicating image interpretation and auto-contouring accuracy. We demonstrate here an automated MR image standardization and auto-contouring strategy for MRI-based ABT of cervix cancer. Methods: MR image standardization consisted of: 1) IINU correction using the MNI N3 algorithm, 2) noise filtering using anisotropic diffusion, and 3) signal intensity normalization using the volumetric median. This post-processing chain was implemented as a series of custom Matlab and Java extensions in MIM (v6.4.5, MIM Software) and was applied to 3D T2 SPACE images of six patients undergoing MRI-based ABT at 3T. Coefficients of variation (CV=σ/µ) were calculated for both original and standardized images and compared using Mann-Whitney tests. Patient-specific cumulative MR atlases of bladder, rectum, and sigmoid contours were constructed throughout ABT, using original and standardized MR images from all previous ABT fractions. Auto-contouring was performed in MIM two ways: 1) best-match of one atlas image to the daily MR image, 2) multi-match of all previous fraction atlas images to the daily MR image. Dice’s Similarity Coefficients (DSCs) were calculated for auto-generated contours relative to reference contours for both original and standardized MR images and compared using Mann-Whitney tests. Results: Significant improvements in CV were detected following MR image standardization (p=0.0043), demonstrating an improvement in MR image uniformity. DSCs consistently increased for auto-contoured bladder, rectum, and sigmoid following MR image standardization, with the highest DSCs detected when the combination of MR image standardization and multi-match cumulative atlas-based auto-contouring was utilized. Conclusion: MR image standardization significantly improves MR image uniformity. The combination of MR image standardization and multi-match cumulative atlas-based auto-contouring produced the highest DSCs and is a promising strategy for MRI-based ABT for cervix cancer.

60 APPLIED LIFE SCIENCES↗

SU-C-BRB-02: Automatic Planning as a Potential Strategy for Dose Escalation for Pancreas SBRT?

Purpose: Stereotactic body radiation therapy (SBRT) has been suggested to provide high rates of local control for locally advanced pancreatic cancer. However, the close proximity of highly radiosensitive normal tissues usually causes the labor-intensive planning process, and may impede further escalation of the prescription dose. The present study evaluates the potential of an automatic planning system as a dose escalation strategy. Methods: Ten pancreatic cancer patients treated with SBRT were studied retrospectively. SBRT was delivered over 5 consecutive fractions with 6 ∼ 8Gy/fraction. Two plans were generated by Pinnacle Auto-Planning with the original prescription and escalated prescription, respectively. Escalated prescription adds 1 Gy/fraction to the original prescription. Manually-created planning volumes were excluded in the optimization goals in order to assess the planning efficiency and quality simultaneously. Critical organs with closest proximity were used to determine the plan normalization to ensure the OAR sparing. Dosimetric parameters including D100, and conformity index (CI) were assessed. Results: Auto-plans directly generate acceptable plans for 70% of the cases without necessity of further improvement, and two more iterations at most are necessary for the rest of the cases. For the pancreas SBRT plans with the original prescription, autoplans resulted in favorable target coverage and PTV conformity (D100 = 96.3% ± 1.48%; CI = 0.88 ± 0.06). For the plans with the escalated prescriptions, no significant target under-dosage was observed, and PTV conformity remains reasonable (D100 = 93.3% ± 3.8%, and CI = 0.84 ± 0.05). Conclusion: Automatic planning, without substantial human-intervention process, results in reasonable PTV coverage and PTV conformity on the premise of adequate OAR sparing for the pancreas SBRT plans with escalated prescription. The results highlight the potential of autoplanning as a dose escalation strategy for pancreas SBRT treatment planning. Further investigations with a larger number of patients are necessary. The project is partially supported by Philips Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-J-197: A Novel Intra-Beam Range Detection and Adaptation Strategy for Particle Therapy

Purpose: In-vivo range detection/verification is crucial in particle therapy for effective and safe delivery. The state-of-art techniques are not sufficient for in-vivo on-line range verification due to conflicts among patient dose, signal statistics and imaging time. We propose a novel intra-beam range detection and adaptation strategy for particle therapy. Methods: This strategy uses the planned mid-range spots as probing beams without adding extra radiation to patients. Such choice of probing beams ensures the Bragg peaks to remain inside the tumor even with significant range variation from the plan. It offers sufficient signal statistics for in-beam positron emission tomography (PET) due to high positron activity of therapeutic dose. The probing beam signal can be acquired and reconstructed using in-beam PET that allows for delineation of the Bragg peaks and detection of range shift with ease of detection enabled by single-layered spots. If the detected range shift is within a pre-defined tolerance, the remaining spots will be delivered as the original plan. Otherwise, a fast re-optimization using range-shifted beamlets and accounting for the probing beam dose is applied to consider the tradeoffs posed by the online anatomy. Simulated planning and delivery studies were used to demonstrate the effectiveness of the proposed techniques. Results: Simulations with online range variations due to shifts of various foreign objects into the beam path showed successful delineation of the Bragg peaks as a result of delivering probing beams. Without on-line delivery adaptation, dose distribution was significantly distorted. In contrast, delivery adaptation incorporating detected range shift recovered well the planned dose. Conclusion: The proposed intra-beam range detection and adaptation utilizing the planned mid-range spots as probing beams, which illuminate the beam range with strong and accurate PET signals, is a safe, practical, yet effective approach to address range uncertainty issues in particle therapy.

60 APPLIED LIFE SCIENCES↗

WE-DE-201-01: BEST IN PHYSICS (THERAPY): A Fast Multi-Target Inverse Treatment Planning Strategy Optimizing Dosimetric Measures for High-Dose-Rate (HDR) Brachytherapy

Purpose: Inverse treatment planning (ITP) for interstitial HDR brachytherapy of gynecologic cancers seeks to maximize coverage of the clinical target volumes (tumor and vagina) while respecting dose-volume-histogram related dosimetric measures (DMs) for organs at risk (OARs). Commercially available ITP tools do not support DM-based planning because it is computationally too expensive to solve. In this study we present a novel approach that allows fast ITP for gynecologic cancers based on DMs for the first time. Methods: This novel strategy is an optimization model based on a smooth DM-based objective function. The smooth approximation is achieved by utilizing a logistic function for the evaluation of DMs. The resulting nonconvex and constrained optimization problem is then optimized with a BFGS algorithm. The model was evaluated using the implant geometry extracted from 20 patient treatment plans under an IRB-approved retrospective study. For each plan, the final DMs were evaluated and compared to the original clinical plans. The CTVs were the contoured tumor volume and the contoured surface of the vagina. Statistical significance was evaluated with a one-sided paired Wilcoxon signed-rank test. Results: As did the clinical plans, all generated plans fulfilled the defined DMs for OARs. The proposed strategy showed a statistically significant improvement (p<0.001) in coverage of the tumor and vagina, with absolute improvements of related DMs of (6.9 +/− 7.9)% and (28.2 +/− 12.0)%, respectively. This was achieved with a statistically significant (p<0.01) decrease of the high-dose-related DM for the tumor. The runtime of the optimization was (2.3 +/− 2.0) seconds. Conclusion: We demonstrated using clinical data that our novel approach allows rapid DM-based optimization with improved coverage of CTVs with fewer hot spots. Being up to three orders of magnitude faster than the current clinical practice, the method dramatically shortens planning time.

60 APPLIED LIFE SCIENCES↗

Operating strategy generators for nuclear reactors

Operating strategy generators, i.e., the software intended for increasing the efficiency of work of nuclear power plant operators, are discussed. The possibilities provided by the domestic and foreign operating-strategy generators are analyzed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Unified Communication Optimization Strategies for Sparse Triangular Solver on CPU and GPU Clusters

This paper presents a unified communication optimization framework for sparse triangular solve (SpTRSV) algorithms on CPU and GPU clusters. The framework builds upon a 3D communication-avoiding (CA) layout of Px × Py × Pz processes that divides a sparse matrix into Pz submatrices, each handled by a Px × Py 2D grid with block-cyclic distribution. We propose three communication optimization strategies: First, a new 3D SpTRSV algorithm is developed, which trades the inter-grid communication and synchronization with replicated computation. This design requires only one inter-grid synchronization, and the inter-grid communication is efficiently implemented with sparse allreduce operations. Second, broadcast and reduction communication trees are used to reduce message latency of the intra-grid 2D communication on CPU clusters. Finally, we leverage GPU-initiated one-sided communication to implement the communication trees on GPU clusters. With these nested inter- and intra-grid communication optimization strategies, the proposed 3D SpTRSV algorithm can attain up to 3.45x speedups compared to the baseline 3D SpTRSV algorithm using up to 2048 Cori Haswell CPU cores. In addition, the proposed GPU 3D SpTRSV algorithm can achieve up to 6.5x speedups compared to the proposed CPU 3D SpTRSV algorithm with Pz up to 64. Finally it is remarkable that the proposed GPU 3D SpTRSV can scale to 256 GPUs using the Perlmutter system while the existing 2D SpTRSV algorithm can only scale up to 4 GPUs.

Sao, Piyush↗

In-Transit Data Transport Strategies for Coupled AI-Simulation Workflow Patterns

Coupled AI-Simulation workflows are becoming the major workloads for HPC facilities, and their increasing complexity necessitates new tools for performance analysis and prototyping of new in-situ workflows. We present SimAI-Bench, a tool designed to both prototype and evaluate these coupled workflows. In this paper, we use SimAI-Bench to benchmark the data transport performance of two common patterns on the Aurora supercomputer: a one-to-one workflow with co-located simulation and AI training instances, and a many-to-one workflow where a single AI model is trained from an ensemble of simulations. For the one-to-one pattern, our analysis shows that node-local and DragonHPC data staging strategies provide excellent performance compared Redis and Lustre file system. For the many-to-one pattern, we find that data transport becomes a dominant bottleneck as the ensemble size grows. Our evaluation reveals that file system is the optimal solution among the tested strategies for the many-to-one pattern.

Tummalapalli, Harikrishna [Argonne National Labora↗

From Powder to Power: Tailored Pre-Milling Strategy that Optimizes Microstructure for Efficient Hydrogen Evolution

The hydrogen evolution reaction (HER) plays a critical role in enabling large-scale electrolytic hydrogen production and advancing future technologies and fuel production. Among non-precious metals, NiMo-based catalysts are particularly attractive due to their capability to promote both water dissociation and hydrogen adsorption in alkaline media. However, conventional NiMo catalysts often suffer from incomplete alloying, particle aggregation, weak metal–support interactions, and surface oxidation, which significantly limit active site utilization, electronic conductivity, and long-term stability. Herein, we report a scalable, solid-state, two-step ball milling strategy for constructing an efficient NiMo/C catalyst for the HER. Pre-milling the metal precursors prior to carbon incorporation promotes efficient solid-state activation, leading to the formation of uniformly alloyed, ultrafine, and defect-rich Ni–Mo nanoparticles with robust metal–carbon interfacial anchoring. Benefiting from this integrated structural design, the optimized NiMo/C catalyst exhibits low overpotentials and Tafel slopes, reduced charge-transfer resistance, and excellent durability under alkaline conditions. Comprehensive structural and surface analysis reveal that the enhanced HER performance can be attributed to the synergistic interplay of homogeneous Ni–Mo alloying, uniform nanoparticle dispersion on a defect-rich carbon scaffold, enhanced accessibility of catalytically active sites, and optimized electronic coupling that stabilizes the catalyst surface. This work highlights the two-step solid-state ball milling strategy as a simple, robust, and scalable route for the preparation of effective and durable non-precious metal HER electrocatalysts, offering practical insights toward large-scale and inexpensive hydrogen production.

Yang, Xiaoxuan [Oak Ridge National Laboratory (ORN↗

Advancing Lithium- and Manganese-Rich Cathodes through a Combined Electrolyte Additive/Surface Treatment Strategy

Lithium- and manganese-rich (LMR) materials provide cost and environmental advantages to other competing cathodes based on nickel or cobalt chemistries. Within the LMR family, layered-layered-spinel (LLS) cathodes have unique properties, detailed herein, that address several of the challenges faced in large-scale implementation of LMR cathodes. This paper details how a LLS//graphite system was considerably improved by combining optimization strategies. First, a cathode surface-treatment process was optimized. Interestingly, cathodes surface-treated at a low temperature (similar to 100 degrees C) exhibited the best results. The optimized LLS cathode was tested vs. graphite using small amounts of lithium difluoro(oxalate)borate electrolyte additive. The combined approach improved various aspects of the electrochemical performance (e.g., impedance, cycle life, and coulombic efficiency) more than each strategy used alone by mitigating Mn dissolution from the cathode and the ensuing deposition on the anode. The report describes a unique method to improve the performance of practically relevant LMR//graphite cells.

25 ENERGY STORAGE↗

Risk-informed Predictive Analytics To Achieve Cost-effective Condition-based Monitoring And Maintenance Strategy

The research involves developing risk-informed predictive analytic capabilities to achieve condition-based monitoring and maintenance strategies to reduce overall maintenance costs. The research utilizes data (real-time data, periodic data, and institutional knowledge) related to a particular plant asset from a specific nuclear plant site to develop risk-informed predictive analytic algorithms. The developed algorithms and codes are used to optimize the maintenance strategy and estimate/forecast generation costs based on the state of health of the plant asset. Developed codes specifically include 1. Parameter estimation code based on Bayesian inference 2. Statistical data analysis code 3. Feature engineering code 4. Health classifier code 5. Diagnosis code 6. Prognosis code 7. Hazard code 8. Generation risk code 9. Economic code

Agarwal, Vivek↗

A perspective on the range of gasoline compression ignition combustion strategies for high engine efficiency and low NOx and soot emissions: Effects of in-cylinder fuel stratification

Many research studies have shown that low temperature combustion in compression ignition engines has the ability to yield ultra-low NOx and soot emissions while maintaining high thermal efficiency. To achieve low temperature combustion, sufficient mixing time between the fuel and air in a globally dilute environment is required, thereby avoiding fuel-rich regions and reducing peak combustion temperatures, which significantly reduces soot and NOx formation, respectively. It has been demonstrated that achieving low temperature combustion with diesel fuel over a wide range of conditions is difficult because of its properties, namely, low volatility and high chemical reactivity. On the contrary, gasoline has a high volatility and low chemical reactivity, meaning it is easier to achieve the amount of premixing time required prior to autoignition to achieve low temperature combustion. In order to achieve low temperature combustion while meeting other constraints, such as low pressure rise rates and maintaining control over the timing of combustion, in-cylinder fuel stratification has been widely investigated for gasoline low temperature combustion engines. The level of fuel stratification is, in reality, a continuum ranging from fully premixed (i.e. homogeneous charge of fuel and air) to heavily stratified, heterogeneous operation, such as diesel combustion. However, to illustrate the impact of fuel stratification on gasoline compression ignition, the authors have identified three representative operating strategies: partial, moderate, and heavy fuel stratification. Thus, this article provides an overview and perspective of the current research efforts to develop engine operating strategies for achieving gasoline low temperature combustion in a compression ignition engine via fuel stratification. In this paper, computational fluid dynamics modeling of the in-cylinder processes during the closed valve portion of the cycle was used to illustrate the opportunities and challenges associated with the various fuel stratification levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of prechamber enabled mixing-controlled combustion strategy for ultra-low methane emissions from lean burn natural gas engines

This numerical study explores the optimization of Prechamber Enabled Mixing-Controlled Combustion (PC-MCC) using natural gas in heavy-duty engines, aiming to enhance combustion efficiency to minimize methane slip and NOx emissions. The approach involves a prechamber ignition system, distinct from conventional spark ignition (SI) systems, to initiate combustion of direct injected natural gas. By leveraging the robust ignition characteristics of the prechamber, the PC-MCC method demonstrates significant potential in achieving efficient combustion akin to diesel engines but with lower greenhouse gas emissions. The research evaluates the effects of various geometric and operational parameters on the combustion process and emissions, including prechamber volume, nozzle diameter, direct injector (DI) geometry, and engine operating strategies. Computational Fluid Dynamics (CFD) simulations are utilized, focusing on a heavy-duty, single-cylinder engine modeled after the Caterpillar C9.3B engine. Key findings indicate that a prechamber volume of 3 cc, coupled with a nozzle diameter of 2.75 mm for two prechamber holes, strikes an optimal balance between combustion efficiency and emissions reduction. This configuration ensures robust combustion across a range of operating conditions while maintaining methane slip within targeted limits. Further investigation into DI geometry shows the significance of the injector umbrella angle and nozzle diameter in shaping the fuel-air mixing and combustion dynamics. An umbrella angle of 130° and a nozzle diameter of 300 microns are identified as optimal, promoting rapid and efficient combustion with minimized methane and NOx emissions. The study also investigates the impact of injection timing and pressure, highlighting their roles in controlling combustion timing and influencing emissions levels. Advanced injection timing is found to be crucial in achieving the desired low methane slip, whereas retarded injection timing assists to reduce NOx emissions while having a slight increase in methane emissions. Operating strategies incorporating various levels of Exhaust Gas Recirculation (EGR) are assessed for their effectiveness in further reducing emissions. The research demonstrates that a judicious combination of internal hot EGR and careful calibration of DI pressure and SOI timing can achieve significant reductions in NOx emissions while keeping methane slip under control. Specifically, an internal EGR level of 15%–25%, combined with DI pressures of 200–300 bar and injection timings at or after top dead center, is recommended. These findings contribute valuable insights into the development of advanced combustion techniques for natural gas engines, offering a viable pathway to reduce methane slip without compromising engine efficiency or performance. The PC-MCC system presents a promising solution for the future of heavy-duty natural gas engine technology to reduce methane emissions.

Nsaif, Osama↗

Genome-wide protein localization prediction strategies for gram negative bacteria

Genome-wide prediction of protein subcellular localization is an important type of evidence used for inferring protein function. While a variety of computational tools have been developed for this purpose, errors in the gene models and use of protein sorting signals that are not recognized by the more commonly accepted tools can diminish the accuracy of their output. As part of an effort to manually curate the annotations of 19 strains of Shewanella, numerous insights were gained regarding the use of computational tools and proteomics data to predict protein localization. Identification of the suite of secretion systems present in each strain at the start of the process made it possible to tailor-fit the subsequent localization prediction strategies to each strain for improved accuracy. Comparisons of the computational predictions among orthologous proteins revealed inconsistencies in the computational outputs, which could often be resolved by adjusting the gene models or ortholog group memberships. While proteomic data was useful for verifying start site predictions and post-translational proteolytic cleavage, care was needed to distinguish cellular versus sample processing-mediated cleavage events. Searches for lipoprotein signal peptides revealed that neither TatP nor LipoP are designed for identification of lipoprotein substrates of the twin arginine translocation system and that the +2 rule for lipoprotein sorting does not apply to this Genus. Analysis of the relationships between domain occurrence and protein localization prediction enabled identification of numerous location-informative domains which could then be used to refine or increase confidence in location predictions. This collective knowledge was used to develop a general strategy for predicting protein localization that could be adapted to other organisms.

59 BASIC BIOLOGICAL SCIENCES↗