Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Electrification: 2023 Final Progress Report

This project proposes to develop a high-power density, high speed traction motor architecture called QMag, driven by a high-power density motor drive inverter using silicon carbide semiconductor devices. This new architecture will achieve the efficiency and power density targets by means of innovative winding and rotor structures, high bandwidth controls, and advanced thermal management solutions. The project team will pursue the goals of the project systematically, through Finite Element Analysis for machine design, through simulation and co-simulation techniques for power electronics and controls evaluation, and finally system design, fabrication, testing and evaluation. If this project successfully achieves and demonstrates the DOE targets for power density, cost, and reliability, the technology has the potential to become a core enabler of the flagship higher power product portfolio in commercial traction businesses, which has so far been confined to DC, induction, Brush Less DC (BLDC), Permanent Magnet AC (PMAC), and reluctance machines.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laser calibration system at ProtoDUNE-HD

The Deep Underground Neutrino Experiment (DUNE) is a full experiment consisting of multiple detectors separated by a near and far site. DUNE will study long-baseline neutrino oscillations, which will provide insight into CP-violation, neutrino mass ordering, and the matter/antimatter asymmetry. Additionally, DUNE will search for nucleon decay and observe neutrinos from supernovae. DUNE relies on liquid argon time projection chambers (LAr TPCs), an excellent technology for tracking particles and reconstructing their interactions with high precision. To achieve its goals, DUNE is supported by the ProtoDUNE experiments at CERN, which serve as large-scale prototypes to validate detector technologies and calibration systems. The precise calibration of the electric field within the detector is vital for accurate 3D reconstruction of particle tracks, particularly in maintaining the consistency of charge measurements along the drift path. This work presents the development and implementation of a laser calibration system designed for ProtoDUNE-II. This poster involved the physical installation and commissioning of the laser system. The commissioning process included extensive testing to ensure alignment and operational efficiency, such as rotating the laser to observe behavior of tracks. The groundwork established during these steps is crucial for future data analysis, aiming to measure the electron lifetime (in the active volume) and map the electric field inside the detector with high precision.

Campanelli, Wallison [LIP]↗

PMU Data Integrity Evaluation through Analytics on a Virtual Test-Bed

Power systems are rapidly becoming populated by phasor measurement units (PMUs) in ever increasing numbers. PMUs are critical components of today s energy management systems, designed to enable near real-time wide area monitoring and control of the electric power system. They are able to measure highly accurate bus voltage phasors as well as branch current phasors incident to the buses at which PMUs are equipped. Synchrophasor data is used for applications varying from state estimation, islanding control, identifying outages, voltage stability detection and correction, disturbance recording, and others. However, PMU-measured readings may suffer from errors due to meter biases or drifts, incorrect configurations, or even cyber-attacks. Furthermore, the testing of early PMUs showed a large disparity between the reported values from PMUs provided by different manufacturers, particularly when frequency was off-nominal, during dynamic events, and when harmonic/inter-harmonic content was present. Detection and identification of PMU gross measurement errors are thus crucial in maintaining highly accurate phasor readings throughout the system. In this paper, we present our work in conducting analytics to determine the trustworthiness and worth of the PMU readings collected across an electric network system. By implementing the IEEE 118 bus test case on a virtual test bed (VTB) , we are able to emulate PMU readings (bus voltage and branch current phasors in addition to bus frequencies) under normal and abnormal conditions using (virtual) PMU sensors deployed across major substations in the network. We emulate a variety of failures such as bus, line, transformer, generator, and/or load failures. Data analytics on the voltage phase angles and frequencies collected from the PMUs show that specious (or compromised) PMU device(s) can be identified through abnormal behaviour by comparing the trend of its frequency and phase angle reading with the ensemble of all other PMU readings in the network. If the reading trend of a particular PMU deviates from the weighted average of the reading trends of other PMUs at nearby substations, then it is likely that the PMU is malfunctioning. We assign a weight to each PMU denoting how electric-topology-wise close it is from where the PMU under consideration is located. The closer a PMU is, the higher the weight it has. To compute the closeness between two nodes in the power network, we employ a form of the resistance distance metric. It computes the electrical distance by taking into consideration the underlying topology as well as the physical laws that govern the electrical connections or flows between the network components. The detection accuracy of erroneous PMUs should be improved by employing this metric. We present results to validate the proposed approach. We also discuss the effectiveness of using an end-to-end VTB approach that allows us to investigate different types of failures and their responses as seen by the ensemble of PMUs. The collected data on certain types of events may be amenable to certain types of analysis (e.g., alerting for sudden changes can be done on a small window of data) and hence determine the data analytics architectures is required to evaluate the streaming PMU data.

and data analytics architecture.↗

Probabilistic Resilience of DER Systems - A Simulation Assisted Optimization Approach

Energy systems resilience is becoming increasingly important as the frequency of major grid outages increases. In this work, we present a methodology to optimize a behind-the-meter distributed energy resource system to sustain a site's critical loads during a pre-defined outage period. With the fixed system design, we then propose an outage simulation approach to estimate the resilience potential of the DER system to sustain loads beyond the fixed outage period - a yearlong resilience performance analysis. We apply statistical analysis to assess the system's resilience performance over a broader parametric problem space on an hourly, monthly, and yearly basis. We demonstrate the impact of the pre-defined outage period on the resilience performance through a case study. Results show that the probability of surviving a random outage of a given duration changes from 20% to 95% when the outage is modeled for a weekday instead of a weekend for the given load-profile.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanical Failure Modes and Longevity of Geo-membranes - 16365

Estimates of the long-term performance of geo-synthetic liner and final cover components have traditionally relied on a small number of standard assumptions originally developed to address the needs of the Resource Conservation and Recovery Act (RCRA) Subtitle D solid waste industry. These past estimates demonstrated that, even under a series of highly conservative factors, the longevity of these components far exceeds the requirements for typical municipal solid waste (MSW) facilities. However, interest in the performance of these components for the disposal of low-level (LLW) and intermediate-level (ILW) radioactive waste landfills has led to additional study of geo-synthetic degradation to address longer assessment periods. These studies allow for the possibility of more rigorous, reliability-based risk assessments of landfill system performance. A particularly strong research need for LLW/ILW facilities is a complete enumeration of the various chemical and mechanical failures modes for geo-membranes serving as final cover and base liner barrier systems. For final covers, failure is defined as allowing an unacceptable flow of water into a containment system. Studies of the various mechanical modes of deformation and rupture for polyethylene sheet allow for a rigorous exploration of the potential causes of geo-membrane barrier system failure. Of particular interest in the performance assessment and engineering of these systems is the ability to use the resulting models to quantify the longevity of these systems with a probabilistic model. An example of this approach is used to illustrate how the consideration of the mechanism for stress cracking in final cover geo-membranes can be adapted for use in simulations of long-term landfill system performance. The results indicate that the effects of cover system design geometry and geo-membrane formulation on performance can be varied significantly by the cover system engineering to meet target performance goals. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Boron-Lined Straw-Tube Neutron Detector Test

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of a boron-lined proportional counter design variation. In the testing described here, the neutron detection efficiency and gamma ray rejection capabilities of a system manufactured by Proportional Technologies, Inc, was tested.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel platinum group metal-free catalyst ink deposition system for combinatorial polymer electrolyte fuel cell performance evaluation

Here, a new system for rapid and precise fabrication of polymer electrolyte fuel cell (PEFC) membrane-electrode assemblies (MEAs) is introduced to facilitate rapid testing and characterization of platinum group metal-free (PGM-free) catalysts, with minimal waste of materials, using commercial combinatorial hardware and multi-channel potentiostat. The commercial combinatorial system, designed for high-throughput catalyst activity evaluation (i.e., low overpotential and current densities) using gas-diffusion electrodes (GDEs), has been further developed to enable simultaneous evaluation of the high current density performance on air of twenty-five cathodes prepared by coating catalyst-ionomer inks directly onto the membrane using a newly-developed deposition system. A nanopipette or micropipette coupled to a precise peristaltic pump is being used for precise and even catalyst ink deposition onto the membrane in each of twenty-five circular electrodes with areas of <1 cm 2 and in the precise locations required by the commercial combinatorial MEA hardware. The automated ink deposition system is coupled with a custom-designed heated vacuum table mounted on a computer-controlled XY stage to prevent deformation of the membrane and electrode layers during ink deposition onto the membrane. This system was utilized to evaluate the impact of ionomer to catalyst ratio on the hydrogen-air fuel cell performance of the PGM-free catalyst.

25 ENERGY STORAGE↗

A machine learning approach for clinker quality prediction and nonlinear model predictive control design for a rotary cement kiln

Abstract Cement manufacturing is energy‐intensive (5Gj/t) and comprises a significant portion of the energy footprint of concrete systems. Incorporating modern monitoring, simulation and control systems will allow lower energy use, lower environmental impact, and lower costs of this widely used construction material. One of the goals of the CESMII roadmap project on the Smart Manufacturing of Cement included developing an analytical process model for clinker quality that includes the chemistry of the kiln feed and accounts for critical process variables. This predictive model will be used in nonlinear model predictive control system designed to significantly reduce process energy use while maintaining or improving product quality. In the cement manufacturing plant used in this study, the kiln feed (meal) is tested every 12 h and used to estimate the mineral composition of the cement kiln output (clinker) using the stoichiometry‐based Bogue's model and the expertise of the plant operators. During kiln operation, kiln output (clinker) is sampled and tested every 2 h to measure its chemical and mineral composition. The predicted and measured values of the clinker composition are used by the plant operators to adjust the kiln input stream and the production process characteristics to maintain stable operation and uniform product quality. However, the time delay between prediction and testing, along with inaccuracies inherent in the Bogue's model have made any process changes designed to minimize energy use problematic, especially in‐light of potential clinker quality issues that process changes often pose. A new analytical model that integrates quality information and process operation information has been developed from data collected from 2 years of production from an operating cement facility. To make the model fuel‐type‐independent, consumed heat energy was computed in the model instead of fuel type and amount. A Feedforward Network was trained and tailored from collected data. Many data‐based simulations were conducted to quantitatively evaluate the proposed model and the 5‐fold cross‐validation procedure was used to test the models. The resulting predictive model was shown to have a low root mean square error (MSE) with respect to the estimated clinker mineral composition compared to that using the industry standard “Bogue’ model”. The end goal of this work was to develop a single machine learning tool that allows the use of quality control data and process control variables to improve energy efficiency of the process in a continuous fashion. The proposed nonlinear model predictive control system (NMPC) can generate predicted kiln production characteristics based on manipulated variables in manner that accurately follows the target product quality values. Simulation results also show that the proposed model produced accurate predictions of kiln outputs that fell within the required constraints, while manipulating control variables within typical operational ranges.

Ali, Asem M.↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Developing Novel Electrode Materials for Aqueous Battery

Aqueous rechargeable batteries (ARBs) are particularly interesting for large-scale energy storage due to their inherent safety, superior rate capability and environmental friendliness. However, ARBs are not widely explored as yet, so we proposed designing, preparing, and testing new intercalation materials for ARBs. Development of these electrodes will enrich the electrode chemistry of existing ARBs, open up new avenues for high-performance electrode and system design, offer opportunities to improve energy efficiency of water purification, and inform future development of controls strategies and management systems for stationary aqueous energy storage. Researchers from Bosch and LBNL collaborated on relevant materials to pursue and the general design of experiments to implement. Bosch researchers prepared and fabricated the electrodes and used various characterization facilities at LBNL to evaluate electrode performance in-device. The research collaboration resulted in identifying electrode materials capable of Na + and Ca 2+ intercalation in aqueous systems, and their application for desalination was explored using testing platform available at LBNL. Besides the specific materials and their performance, the data collected during the study was also used to inform a broader techno-economic analysis to compare intercalation-desalination technique to commercially available capacitive desalination approach. Outcomes of this research effort will be published in peer-reviewed journals.

25 ENERGY STORAGE↗

Cryogenic Control Circuitry for Superconducting Qubits

Superconducting qubits have reached the point where system designers are worried about the heat that control wiring brings into the cryostat. To continue scaling cryogenic quantum systems, control solutions that work inside the cold space must be explored. One possibility is to use control electronics that is native to superconductivity, so called single-flux-quantum (SFQ) circuitry, to form an interface between qubits and whatever other electronics is needed to control eventual quantum systems. To begin exploring the utility of SFQ as control circuitry, we performed modeling and experiments on qubit readout using ballistic fluxons which are SFQ in the limit of ballistic fluxon transport. Our modeling results show that a flavor of qubit, the fluxonium, can be read out using ballistic fluxons. We designed test samples to prove some of the key concepts needed for such a readout but were ultimately unable to getting a working demonstration. The lack of testing success was due to challenges in fabrication and running short of time to perform testing rather than a fundamental problem with our analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Performance of the SPT-SLIM Receiver Cryostat

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wavelength line-intensity mapping experiment, which was deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We report on the cryogenic performance of the SPT-SLIM receiver for the first year of commissioning observations. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Refrigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150 mK. We demonstrate stable thermal performance of the focal plane module during observations consistent with thermal modeling, enabling a cryogenic operating efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, M. R. [Fermilab; Chicago U., KICP]↗

Remedy Application Statistics

The forms and workflow developed were designed to collect additional statistical information not normally available in out of- the-box implementations of the Remedy Action Request System designed by BMC Software. This workflow is used to collect additional information about users accessing the Remedy application, such as operating system and browser type. This information along with frequency of user logins, number of emails sent and received, and overall license usage help provide Remedy Administrators a better overview of the application they support. These custom forms and workflow work heavily with existing out-of-the-box forms in Remedy, and display the collected data to users through the product BMC’s companion product Smart Reporting.

Van Sickle, James↗

Method for designing a combustion system with reduced environmentally-harmful emissions

A method for designing a combustion system which emits less of at least one environmentally-harmful emission is presented. In a describing step, an injector which introduces a fuel into a combustion chamber is described via a CFD code. In a modeling step, combustion kinetics of the fuel are modeled via a pre-processing code as the fuel mixes and reacts with an oxidizer. In a first selecting step, at least one primary scalar is derived during the modeling of the combustion kinetics. In a performing step, a table look-up is performed to obtain at least one data from a look-up database based on the primary scalar. In a second selecting step, at least one secondary scalar is selected in addition to the primary scalar(s). In a specifying step, at least one chemical pathway of formation or destruction for the secondary scalar is specified via a chemistry manager wherein the secondary scalar is representative of the environmentally-harmful emission(s) of the chemical pathway(s). In a utilizing step, the data is utilized to evaluate the chemical pathway(s) to quantify the environmentally-harmful emission(s). In an identifying step, an improvement to the combustion system is identified which reduces the environmentally-harmful emission(s).

Zambon, Andrea C.↗

The effect of catholyte and catalyst layer binders on CO 2 electroreduction selectivity

Electrochemical reduction of carbon dioxide (CO 2 ) is an attractive technology for converting CO 2 to value-added chemicals by using renewably generated electricity. This work combines both experimental and theoretical analyses to investigate the role of different catalysts (Ag/Vu and SnO 2 /Vu), binder materials, and catholyte compositions on the selectivity of a CO 2 electrolysis cell to the two-electron CO 2 reduction products CO and formate. As a complementary effort, a 2D multi-physics transport model was developed to elucidate the fundamental processes and species concentrations in the cathode components. It was shown that the selectivity of CO 2 reduction to CO can change significantly when different catholyte compositions and binder materials are used, whereas the selectivity of CO 2 to formate is relatively stable across the conditions studied. These insights can be used to inform decisions regarding the electrode development and system design in CO 2 electrolyzers and ultimately contribute to scaling energy-efficient electrochemical CO 2 -reduction systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tailoring electron transfer pathway for photocatalytic N 2 -to-NH 3 reduction in a CdS quantum dots-nitrogenase system

The combination of abiotic photosensitizers with purified enzymes in a biohybrid system offers a promising pathway to utilizing light to accomplish challenging chemical transformations and provides insights into the rational photocatalytic system design for efficient solar-to-chemical energy conversion. In this work, we demonstrate a hybrid photocatalytic system for ammonia production from N2 by combining cadmium sulfide quantum dots (CdS QDs) and Mo-nitrogenase from Azotobacter vinelandii, composed of the iron protein (FeP) and the molybdenum-iron protein (MoFeP). Photoexcited electrons from the CdS QD are delivered by an electron transfer mediator through the FeP to the catalytic MoFeP. The complete system was optimized for the ligand on the CdS QDs, mediators, and reaction conditions. The best results were achieved with β-mercaptoethanol as a QD ligand. The mediator test revealed that 1,1'-bis(3-sulfonatopropyl)-4,4'-bipyridinium (SPr)2V (-0.4 V vs. NHE) supports the reduction of protons and N 2 to H 2 and ammonia catalyzed by nitrogenase. However, in the presence of 1,1'-trimethylene-2,2'-bipyridinium TQ (-0.54 V vs. NHE) as a mediator, nitrogenase catalysis resulted in remarkably more products. The UV-vis and in situ potentiometric studies revealed that better performance with TQ is achieved due to the significantly more negative solution potential allowing for efficient reduction of FeP. As a result, the quantum yield for conversion of absorbed photons to ammonia attains 16%, far exceeding that of previously reported nitrogenase-based systems. This work reveals the importance of tuning the electron transfer pathways in photocatalytic systems and illustrates a potent strategy for efficient electronic coupling of a photosensitizer and an N 2 reduction catalyst.

36 MATERIALS SCIENCE↗

Secondary Use-Plug-and-Play Energy Storage System Composed of Multiple Energy Storage Technologies

Low-cost, grid-connectable energy storage technologies represent a significant challenge for the electric grid of the future. Energy storage technologies are in rapid development with targets to reduce the storage medium cost. However, a significant cost to deployment also comes in the integration. This paper presents the development of a plug-and-play system for supporting secondary use multiple battery systems into a single grid connectable unit. Results of the system design are demonstrated in a controller hardware in the loop (CHIL) platform. Simulations of two energy storage systems operating in parallel and dispatched optimally are presented.

Starke, Michael↗

Performance Analysis of Deep Learning Workloads on Leading-edge Systems

This work examines the performance of leading-edge systems designed for machine learning computing, including the NVIDIA DGX-2, Amazon Web Services (AWS) P3, IBM Power System Accelerated Compute Server AC922, and a consumer-grade Exxact TensorEX TS4 GPU server. Representative deep learning workloads from the fields of computer vision and natural language processing are the focus of the analysis. Performance analysis is performed along with a number of important dimensions. Performance of the communication interconnects and large and high-throughput deep learning models are considered. Different potential use models for the systems as standalone and in the cloud also are examined. The effect of various optimization of the deep learning models and system configurations is included in the analysis.

97 MATHEMATICS AND COMPUTING↗