Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Development program for 1.93-micron lasers

For the first time lasers operating at 1.93 microns were demonstrated. The lasers were fabricated by Vapor Phase Epitaxial (VPE) growth techniques currently used for the fabrication of high power lasers at 1.3 microns. The structure of these laser diodes consisted of compositionally graded, sulfur-doped InAsP, grown on an InP substrate; a constant-composition n+InAs(0.27)P(0.73) layer, which is the first cladding layer; an In(0.66)Ga(0.34)As layer, which is the active region, and a second InAs(0.27)P(0.73) layer. The devices were oxide-stripe DH lasers (gain-guided only). The best devices had 80 K lasing thresholds in the range of from 80 to 150 mA, and T sub o (below 220 K) in the range of 60 to 90 K. The highest observed temperature of oscillation was 15.5 C. The highest observed power output at 80 K was in the range of 3 to 5 mW. The calculated delta I/delta T was 4.4 A/K. As a part of the materials development, PIN homojunction detectors having the band edge near 1.93 were also fabricated. The best devices (100 micron diameter, mesa structure) exhibited room temperature dark currents in the range of from 20 to 50 nA and had QE at 1.93 microns in the range of 35 to 40 percent. In addition to the device results, the InGaAs-InAsP materials system was extensively investigated and low defect density layers can now be grown allowing for significant device performance improvement.

Longeway, P.↗

Measurements of the radiation dose to LDEF by means of passive dosimetry

A very simple experiment was fielded on LDEF to measure the energetic radiation dose by means of passive dosimetry. It consisted of two identical packets of 16 LiF thermoluminescent dosimeters (TLD) arranged in planar arrays. One array was placed on the leading edge of the spacecraft, the other on the trailing edge. These arrays were installed in opaque packets of 1 mil Al foil and Kapton tape mounted behind an Al plate of 30 mils thickness. The nominal energy thresholds were 14 MeV for protons and 650 keV for electrons. In addition to the flight arrays, two control arrays were prepared which were kept with the flight arrays as long as possible during experimental integration and then stored in the lab. The flight and control arrays were read out alternating in groups of four; it was found that the control dose was negligible. The flight and control detectors were exposed to a 55 MeV proton beam in order to provide a recalibration of the detectors. It was found that the post-flight and pre-flight calibrations were in good agreement. A comparison of results with the prediction shows that the measured dose was a factor of 4 to 5 low. It is possible that there was in-flight annealing of the TLDs as a result of the long mission and perhaps temperature excursions of the sensors. The East-West effect was larger than expected. The ratio of 1.65 is approximately what was expected for the protons alone. Electrons should reduce the dose ratio since electrons add equally to the leading and trailing edge dose. A possible explanation is that the electron dose was negligible compared to the proton dose.

Blake, J. B.↗

The Design and Performance of IceCube DeepCore

The IceCube neutrino observatory in operation at the South Pole, Antarctica, comprises three distinct components: a large buried array for ultrahigh energy neutrino detection, a surface air shower array, and a new buried component called DeepCore. DeepCore was designed to lower the IceCube neutrino energy threshold by over an order of magnitude, to energies as low as about 10 GeV. DeepCore is situated primarily 2100 m below the surface of the icecap at the South Pole, at the bottom center of the existing IceCube array, and began taking pbysics data in May 2010. Its location takes advantage of the exceptionally clear ice at those depths and allows it to use the surrounding IceCube detector as a highly efficient active veto against the principal background of downward-going muons produced in cosmic-ray air showers. DeepCore has a module density roughly five times higher than that of the standard IceCube array, and uses photomultiplier tubes with a new photocathode featuring a quantum efficiency about 35% higher than standard IceCube PMTs. Taken together, these features of DeepCore will increase IceCube's sensitivity to neutrinos from WIMP dark matter annihilations, atmospheric neutrino oscillations, galactic supernova neutrinos, and point sources of neutrinos in the northern and southern skies. In this paper we describe the design and initial performance of DeepCore.

Stamatikos, M.↗

The Higgs portal above threshold

The discovery of the Higgs boson opens the door to new physics interacting via the Higgs Portal, including motivated scenarios relating to baryogenesis, dark matter, and electroweak naturalness. In this study, we systematically explore the collider signatures of singlet scalars produced via the Higgs Portal at the 14TeV LHC and a prospective 100TeV hadron collider. We focus on the challenging regime where the scalars are too heavy to be produced in the decays of an on-shell Higgs boson, and instead are produced primarily via an o ff-shell Higgs. Assuming these scalars escape the detector, promising channels include missing energy in association with vector boson fusion, monojets, and top pairs. In addition, we forecast the sensitivity of searches in these channels at √s = 14 & 100 TeV and compare collider reach to the motivated parameter space of singlet-assisted electroweak baryogenesis, Higgs Portal dark matter, and neutral naturalness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of the Electronic Crosstalk Effect in Terra MODIS Long-Wave Infrared Photovoltaic Bands Using Lunar Images

The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the key sensors among the suite of remote sensing instruments on board the Earth Observing System Terra and Aqua spacecrafts. For each MODIS spectral band, the sensor degradation has been measured using a set of on-board calibrators. MODIS also uses lunar observations from nearly monthly spacecraft maneuvers, which bring the Moon into view through the space-view port, helping to characterize the scan mirror degradation at a different angles of incidence. Throughout the Terra mission, contamination of the long-wave infrared photovoltaic band (LWIR PV, bands 27-30) signals has been observed in the form of electronic crosstalk, where signal from each of the detectors among the LWIR PV bands can leak to the other detectors, producing a false signal contribution. This contamination has had a noticeable effect on the MODIS science products since 2010 for band 27, and since 2012 for bands 28 and 29. Images of the Moon have been used effectively for determining the contaminating bands, and have also been used to derive correction coefficients for the crosstalk contamination. In this paper, we introduce an updated technique for characterizing the crosstalk contamination among the LWIR PV bands using data from lunar calibration events. This approach takes into account both the in-band and out-of-band contribution to the signal contamination for each detector in bands 27-30, which is not considered in previous works. The crosstalk coefficients can be derived for each lunar calibration event, providing the time dependence of the crosstalk contamination. Application of these coefficients to Earth-view image data results in a significant reduction in image contamination and a correction of the scene radiance for bands 27- 30. Also, this correction shows a significant improvement to certain threshold tests in the MODIS Level-2 Cloud Mask. In this paper, we will detail the methodology used to identify and correct the crosstalk contamination for the LWIR PV bands in Terra MODIS. The derived time-dependent crosstalk coefficients will also be discussed. Finally, the impact of the correction on the downstream data products will be analyzed.

Wilson, Truman↗

A Low-Power Time-to-Digital Converter for the CMS Endcap Timing Layer (ETL) Upgrade

We present the design and test results of a Time-to-Digital-Converter (TDC). The TDC will be a part of the readout ASIC, called ETROC, to read out Low-Gain Avalanche Detectors (LGADs) for the CMS Endcap Timing Layer (ETL) of High-Luminosity LHC upgrade. One of the challenges of the ETROC design is that the TDC is required to consume less than 200 W for each pixel at the nominal hit occupancy of 1%. To meet the low-power requirement, we use a single delay line for both the Time of Arrival (TOA) and the Time over Threshold (TOT) measurements without delay control. A double-strobe self-calibration scheme is used to compensate for process variation, temperature, and power supply voltage. The TDC is fabricated in a 65 nm CMOS technology. The overall performances of the TDC have been evaluated. The TOA has a bin size of 17.8 ps within its effective dynamic range of 11.6 ns. The effective measurement precision of the TOA is 5.6 ps and 9.9 ps with and without the nonlinearity correction, respectively. The TDC block consumes 97 W at the hit occupancy of 1%. Over a temperature range from 23 C to 78 C and a power supply voltage range from 1.05 V to 1.35 V (the nominal value of 1.20 V), the self-calibrated bin size of the TOA varies within 0.4%. The measured TDC performances meet the requirements except that more tests will be performed in the future to verify that the TDC complies with the radiation-tolerance specifications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST

Detectors based upon the noble elements, especially liquid xenon as well as liquid argon, as both single- and dual-phase types, require reconstruction of the energies of interacting particles, both in the field of direct detection of dark matter (weakly interacting massive particles WIMPs, axions, etc.) and in neutrino physics. Experimentalists, as well as theorists who reanalyze/reinterpret experimental data, have used a few different techniques over the past few decades. In this paper, we review techniques based on solely the primary scintillation channel, the ionization or secondary channel available at non-zero drift electric fields, and combined techniques that include a simple linear combination and weighted averages, with a brief discussion of the application of profile likelihood, maximum likelihood, and machine learning. Comparing results for electron recoils (beta and gamma interactions) and nuclear recoils (primarily from neutrons) from the Noble Element Simulation Technique (NEST) simulation to available data, we confirm that combining all available information generates higher-precision means, lower widths (energy resolution), and more symmetric shapes (approximately Gaussian) especially at keV-scale energies, with the symmetry even greater when thresholding is addressed. Near thresholds, bias from upward fluctuations matters. For MeV-GeV scales, if only one channel is utilized, an ionization-only-based energy scale outperforms scintillation; channel combination remains beneficial. We discuss here what major collaborations use.

argon↗

Empirical beam hardening correction (EBHC) for CT

Purpose: Due to x-ray beam polychromaticity and scattered radiation, attenuation measurements tend to be underestimated. Cupping and beam hardening artifacts become apparent in the reconstructed CT images. If only one material such as water, for example, is present, these artifacts can be reduced by precorrecting the rawdata. Higher order beam hardening artifacts, as they result when a mixture of materials such as water and bone, or water and bone and iodine is present, require an iterative beam hardening correction where the image is segmented into different materials and those are forward projected to obtain new rawdata. Typically, the forward projection must correctly model the beam polychromaticity and account for all physical effects, including the energy dependence of the assumed materials in the patient, the detector response, and others. We propose a new algorithm that does not require any knowledge about spectra or attenuation coefficients and that does not need to be calibrated. The proposed method corrects beam hardening in single energy CT data. Methods: The only a priori knowledge entering EBHC is the segmentation of the object into different materials. Materials other than water are segmented from the original image, e.g., by using simple thresholding. Then, a (monochromatic) forward projection of these other materials is performed. The measured rawdata and the forward projected material-specific rawdata are monomially combined (e.g., multiplied or squared) and reconstructed to yield a set of correction volumes. These are then linearly combined and added to the original volume. The combination weights are determined to maximize the flatness of the new and corrected volume. EBHC is evaluated using data acquired with a modern cone-beam dual-source spiral CT scanner (Somatom Definition Flash, Siemens Healthcare, Forchheim, Germany), with a modern dual-source micro-CT scanner (TomoScope Synergy Twin, CT Imaging GmbH, Erlangen, Germany), and with a modern C-arm CT scanner (Axiom Artis dTA, Siemens Healthcare, Forchheim, Germany). A large variety of phantom, small animal, and patient data were used to demonstrate the data and system independence of EBHC. Results: Although no physics apart from the initial segmentation procedure enter the correction process, beam hardening artifacts were significantly reduced by EBHC. The image quality for clinical CT, micro-CT, and C-arm CT was highly improved. Only in the case of C-arm CT, where high scatter levels and calibration errors occur, the relative improvement was smaller. Conclusions: The empirical beam hardening correction is an interesting alternative to conventional iterative higher order beam hardening correction algorithms. It does not tend to over- or undercorrect the data. Apart from the segmentation step, EBHC does not require assumptions on the spectra or on the type of material involved. Potentially, it can therefore be applied to any CT image.

60 APPLIED LIFE SCIENCES↗

In-Pixel Readout IC with compact in-pixel ADC for Pixel detectors at HL LHC

The prototype Smart Pixel concept test chip (SP28), designed in a CMOS 28 nm bulk process, is a proof of concept readout integrated circuit (ROIC) designed for a future Phase III High Luminosity upgrade of the Large Hadron Collider. It employs a synchronous analog to digital converter (ADC) for the front-end design, with signal processing and data conversion within a single bunch crossing of 25 ns. It is therefore capable of accurately detecting hits occurring in consecutive bunch crossings, without off-time registration of events and pileup insensitivity, making it particularly suitable for the inner most layers of the vertex detector. The ROIC consists of a matrix of 32 × 16 pixels, each 25 × 25 µm 2 in size. Each pixel contains a charge sensitive preamplifer with leakage current compensation, three auto-zero comparators for a 2-bit fash-type ADC. The total power consumption is approximately 5 µW per pixel. The measured noise at the output of all the hit comparators across the ROIC is < 90 e- with threshold dispersion < 45 e-RMS, which allows an in-time threshold setting of ≈ 475 e-.

Parpillon, Benjamin↗

Exotic quarkonium states in CMS

The studies of the production of the X(3872), either prompt or from B-hadron decays, and of the J/ψϕ mass spectrum in B-hadron decays have been carried out by using pp collisions at √s = 7 TeV collected with the CMS detector at the LHC. The cross-section ratio of the X(3872) with respect to the ψ(2S) in the J/ψπ{sup +}π{sup −} decay channel and the fraction of X(3872) coming from B-hadron decays are measured as a function of transverse momentum (p{sub T}), covering unprecedentedly high values of p{sub T}. For the first time, the prompt X(3872) cross section times branching fraction is extracted differentially in p{sub T} and compared with NRQCD predictions. The dipion invariant-mass spectrum of the J/ψπ{sup +}π{sup −} system in the X(3872) decay is also investigated. A peaking structure in the J/ψϕ mass spectrum near threshold is observed in B{sup ±} → J/ψϕK{sup ±} decays. The data sample, selected on the basis of the dimuon decay mode of the J/ψ, corresponds to an integrated luminosity of 5.2 fb{sup −1}. Fitting the structure to an S-wave relativistic Breit–Wigner lineshape above a three-body phase-space nonresonant component gives a signal statistical significance exceeding five standard deviations. The fitted mass and width values are m = 4148.0 ± 2.4(stat.) ± 6.3(syst.) MeV and Γ = 28+15 − 11(stat.) ± 19(syst.) MeV, respectively. Evidence for an additional peaking structure at higher J/ψϕ mass is also reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity of the IceCube neutrino detector to dark matter annihilating in dwarf galaxies

In this paper, we compare the relative sensitivities of gamma-ray and neutrino observations to the dark matter annihilation cross section in leptophilic models such as have been designed to explain PAMELA data. We investigate whether the high energy neutrino telescope IceCube will be competitive with current and upcoming searches by gamma-ray telescopes, such as the Atmospheric Cerenkov Telescopes (H.E.S.S., VERITAS, and MAGIC), or the Fermi Gamma-Ray Space Telescope, in detecting or constraining dark matter particles annihilating in dwarf spheroidal galaxies. We find that after 10 years of observation of the most promising nearby dwarfs, IceCube will have sensitivity comparable to the current sensitivity of gamma-ray telescopes only for very heavy (m{sub X} > or approx. 7 TeV) or relatively light (m{sub X} < or approx. 200 GeV) dark matter particles which annihilate primarily to {mu}{sup +{mu}-}. If dark matter particles annihilate primarily to {tau}{sup +{tau}-}, IceCube will have superior sensitivity only for dark matter particle masses below the 200 GeV threshold of current Atmospheric Cerenkov Telescopes. If dark matter annihilations proceed directly to neutrino-antineutrino pairs a substantial fraction of the time, IceCube will be competitive with gamma-ray telescopes for a much wider range of dark matter masses. K. F. would like to thank the Aspen Center for Physics and the Texas Cosmology Center, and P. S. would like to thank MCTP.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The III-V photocathode - A major detector development.

Description of new (III-V) photocathodes which show improvements in sensitivity of as much as ten to a hundred times over conventional cathodes in the near infrared and useful improvements at shorter wavelengths. The development stems from a combination of basic knowledge of the photoemission process, gained in the 1950s, and the advancing understanding of the technology of III-V materials, in the 1960s. The superior performance of these cathodes is due to the fact that the vacuum level at the surface lies below the bottom of the conduction band in the bulk of the material. Consequently, the threshold of response is set by the III-V bandgap. The bandgap (and the threshold of response) can be varied by alloying different III-V materials together. A reduction in thermionic emission is realized with these cathodes. At present no semitransparent III-V cathodes with comparably interesting performance are available. The problems hindering further improvements, as well as the problems of placing these cathodes in practical multipliers and image tubes, are discussed briefly.

Spicer, W. E.↗

Adaptive Envelope Detector-Based Phase Fault Detection Method for Power System Grid Distortions

In this study, a phase fault detection algorithm is developed by employing the envelope detector method. The proposed method diagnoses faults among phases and defines fault areas in the incoming signal. The designed algorithm consists of three steps: analytical signal conversion, complex magnitude, and fault detection. Initially, an analytical signal is obtained from the incoming power signal to determine the instantaneous amplitude and phase of the signal. A complex magnitude operation is applied to analytical signals to display changes in amplitude. On the basis of the threshold values specified by the user, the last step identifies the distortion signal in terms of the type of error and size. The proposed method is tested with realistically simulated substation power signal data and real power system data from the Grid Event Signature Library. The obtained results revealed that the proposed method detects distortions accurately.

Alaca, Ozgur↗

Quantum Devices for Neutrino and Rare Particle Detection (Final Report)

This report summarizes the technical work completed under the DOE-QuanISED program. This grant allowed the MIT group --and associated groups on the project, including UMass Amherst and Argonne National Laboratory -- to explore the use of superconducting bolometers for the purpose of neutrino and low mass dark matter detection. These low threshold bolometric detection techniques have wide applicability in nuclear and particle physics, including searching for low mass weakly-interacting dark matter; detecting neutrinos via coherent neutrino scattering; searching for axions and nuclear non-proliferation. In addition, we explored how using techniques readily used by the quantum computing community–such as multiplexed microwave resonators and quantum amplifiers—could be used as a low noise readout scheme for an array of superconducting detectors. We briefly summarized the accomplishments under the project, and what future research directions have spawned from this research.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wide field of view laser beacon system for three-dimensional aircraft position measurement

This paper presents a new wide field of view laser beacon system for measurement, in three dimensions, of aircraft or other remote objects. The system is developed for aircraft collision hazard warning independent of ground-based hardware, as well as for flight research, helicopter-assisted construction and rescue, and robotic manipulation applications. Accurate information describing the relative range, elevation, and azimuth of the aircraft are generated by the sweep of a low-power fan-shaped rotating laser beacon past an array of optical detectors. The system achieves a wide angle of acceptance of laser beacon light through use of compound parabolic concentrators, which collimate the light for spectral filtering to minimize solar interference. An on-board microprocessor system converts the pulse sequence to aircraft position in real time. System reliability and performance are enhanced through narrow pass filtering of the pulse signals, digital logic design to mask spurious signals, and adaptive modulation of trigger threshold levels.

Sweet, L. M.↗

12 C(p,p') 12 C Reaction ( E p =19.5–30 MeV) for Active Interrogation of Special Nuclear Material

Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation, the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a promising method to overcome those challenges. Current active-interrogation systems that incorporate radiography tend to use bremsstrahlung beams, which can deliver high radiation doses. Low-energy ion-driven nuclear reactions that produce multiple monoenergetic photons may be used as an alternative. The 12 C ( p , p ' ) 12 C reaction is one such reaction that could produce large yields of highly penetrating 4.4- and 15.1-MeV gamma rays. This reaction does not directly produce neutrons below the approximately 19.7 MeV threshold, and the 15.1-MeV gamma-ray line is well matched to the photofission cross section of 235 U and 238 U . In this article, we report the measurements of thick-target gamma-ray yields at 4.4 and 15.1 MeV from the 12 C ( p , p ' ) 12 C reaction at proton energies of 19.5, 25, and 30 MeV. Measurements are made with two 3 -in. EJ-309 cylindrical liquid scintillation detectors and thermoluminescent dosimeters placed at 0 ° and 90 ° , with an additional 1.5 -in. Na I ( Tl ) cylindrical scintillation detector at 0 ° . We estimate the highest yields of the 4.4- and 15.1-MeV gamma rays of 1.65 × 10 10 and 4.47 × 10 8 sr - 1 μ C - 1 at a proton energy of 30 MeV, respectively. The yields in all experimental configurations are greater than in a comparable deuteron-driven reaction that produces the same gamma-ray energies— 11 B ( d , n γ ) 12 C . However, a significant increase of the neutron radiation dose accompanies the proton energy increase from 19.5 to 30 MeV.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Validation of an image simulation technique for two computed radiography systems: An application to neonatal imaging

Purpose: The purpose of this study is to develop a computer model to simulate the image acquisition for two computed radiography (CR) imaging systems used for neonatal chest imaging: (1) The Agfa ADC Compact, a flying spot reader with powder phosphor image plates (MD 40.0); and (2) the Agfa DX-S, a line-scanning CR reader with needle crystal phosphor image plates (HD 5.0). The model was then applied to compare the image quality of the two CR imaging systems. Methods: Monte Carlo techniques were used to simulate the transport of primary and scattered x rays in digital x-ray systems. The output of the Monte Carlo program was an image representing the energy absorbed in the detector material. This image was then modified using physical characteristics of the CR imaging systems to account for the signal intensity variations due to the heel effect along the anode-cathode axis, the spatial resolution characteristics of the imaging system, and the various sources of image noise. The simulation was performed for typical acquisition parameters of neonatal chest x-ray examinations. To evaluate the computer model, the authors compared the threshold-contrast detectability in simulated and experimentally acquired images of a contrast-detail phantom. Threshold-contrast curves were computed using a commercially available scoring program. Results: The threshold-contrast curves of the simulated and experimentally acquired images show good agreement; for the two CR systems, 93% of the threshold diameters calculated from the simulated images fell within the confidence intervals of the threshold diameter calculated from the experimentally assessed images. Moreover, the superiority of needle based CR plates for neonatal imaging was confirmed. Conclusions: The good agreement between simulated and experimental acquired results indicates that the computer model is accurate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗