Apparatus tests flexural durability of FCC
Device tests electric continuity of flat cable conductors, FCC, in temperature controlled environment. Test method is described.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Device tests electric continuity of flat cable conductors, FCC, in temperature controlled environment. Test method is described.
Nondestructive test methods are used for evaluating bond integrity of low-density polyurethane spray-on foam used as cryogenic insulation on aluminum alloy surfaces.
Advanced composite standards, representing potential variations occurring when composites are processed into finished structures, were designed, fabricated and tested. Testing methods utilized were ultrasonic C-scan, radiography, and infrared.
Fracture energies of WC-6Co, Boride 5 (ZrB2+SiC), Boride 8(ZrB2+SiC+C) and Boride 8-M2(ZrB2+SiC+C) were measured by slow bend and impact tests of notched charpy bars. Cobalt bonded tungsten carbide exhibited impact energies of 0.76 ft-lb or 73.9 in-lb/square inch. Boride 5 and the Boride 8 exhibit impact energies one third and one quarter of that observed for WC-6Co comparing favorably with measurements for SiC and Si3N4. Slow bend-notched bar-fracture energies for WC-6Co were near 2.6 in-lb/square inch or 1/20 the impact energies. Slow bend energies for Boride 8-M2, Boride 8 and Boride 5 were 58%, 42% and 25% of the value observed for WC-6Co. Fractograph showed differences for WC-6Co where slow bend testing resulted in smooth transgranular cleavage while samples broken by impact exhibited intergranular failures. By contrast the boride fractures showed no distinction based on testing method. Fabrication studies were conducted to effect alteration of the boride composites by alloying and introduction of graphite cloth.
Work is reported for fabricating and testing the fiberglass overwrapped titanium pressure vessel for cryogenic service. Difficulties encountered in the tank liner fabrication phase involved explosive forming, vacuum annealing, chemical milling and electron beam welding. While each of these processes and the nondestructive test methods employed are normally considered to be individually reliable, the combination of poor material together with fabrication and development reversals prevented the full achievement of the desired end results. Eight tanks plus a prototype and tool proofing article were produced. Six of the vessels failed during the hydrostatic sizing operation. One of the remaining tanks was hydrostatically pressurized to burst and the other was pressurized repeatedly at 75 F from 100 psi to the operating pressure until failure occurred. As a result, it is not possible to draw firm conclusions as to the true value of the design concept due to the problems encountered in the program.
A series of candidate materials for use in large balloons was tested and their tensile and shear strength capabilities were compared. The tests were done in a cold box at -68 C (-90 F). Some of these materials were fabricated on a special machine called the flying thread loom. This machine laminates various patterns of polyester yarn to a thin polyester film. The results show that the shear strength of materials changes with the angle selected for the transverse yarns, and substantial increases in biaxial load carrying capabilities, compared to materials formerly used, are possible. The loom capabilities and the test methods are discussed.
Design criteria are presented to provide guidance in assessing electromagnetic interference from onboard sources and establishing requisite control in spacecraft design, development, and testing. A comprehensive state-of-the-art review is given which covers flight experience, sources and transmission of electromagnetic interference, susceptible equipment, design procedure, control techniques, and test methods.
Experimental efforts in this program for this period. Mechanical property tests of wrought and cast nickel-base alloys and one wrought cobalt-base alloy were conducted in 34.5 MN/sq m (5000-psig) helium and hydrogen or hydrogen mixtures. Comparison of test results was made to determine degradation of properties due to the hydrogen environments. All testing was conducted on solid specimens exposed to external gaseous pressure. Specific mechanical properties determined and the testing methods used are summarized.
Results are reported from a continued study of MPD thrusters operating in the quasi-steady mode and using electrode vapor as the propellant. Testing methods were refined, and performance data is now available for a fairly wide range of thruster geometries. Performance was found to be strongly dependent on thruster geometry, with some designs showing approximately twice the efficiency obtained during the preceding contract period. The radial clearance between electrodes, the attachment point of the arc on the cathode, and the electrical resistance of the electrodes appear to be important design variables.
The elements in the evacuated multilayer insulation system were investigated, and the major weight contributors for optimization selected. Outgassing tests were conducted on candidate vacuum jacket materials and experiments were conducted to determine the vacuum and structural integrity of selected vacuum jacket configurations. A nondestructive proof test method, applicable to externally pressurized shells, was validated on this program.
Based upon extensive contacts with vendors, a broad array of non-flammable polymeric specie, and additives generally noted to have flame retarding properties, were considered. The following polymeric matrices were examined: modified silicone and fluorosilicone RTV's polyesters, epoxies, urethanes, and epoxy-urethanes. Optimization of formulations to obtain a suitable balance between the various properties and flammability resistance led to the final selection of a silicone RTV/additive-loaded compound which meets almost all program requirements. The very low valued properties found are within a realistic level of design toleration. Complete formulation, processing, and test data is provided for this compound, EPOCAST 87517-A/B, and the other formulations prepared by the project. Details of those test methods are presented along with procedures utilized in the program. In addition, a description of the special flammability facility previously designed and then modified for this program is also presented.
Attempts were made to develop a dynamic metal working machine tool system using probability information on external factors and independent disturbances of the parameters. The problem was optimized in two stages: (1) creation of mathematical models under conditions determined by input influences, and (2) processing the results of calculations obtained on such models. Data were obtained on the patterns of distribution of dynamic quality characteristics of the tool, vibration frequencies and amplitudes, attenuation coefficients, and duration of a transition process. These data were obtained using a digital computer, statistical test methods, or logical possibility trees.
The preliminary development plan for the Pioneer Venus program is presented. This preliminary plan treats only developmental aspects that would have a significant effect on program cost. These significant development areas were: master program schedule planning; test planning - both unit and system testing for probes/orbiter/ probe bus; ground support equipment; performance assurance; and science integration Various test planning options and test method techniques were evaluated in terms of achieving a low-cost program without degrading mission performance or system reliability. The approaches studied and the methodology of the selected approach are defined.
The method, test data, and results of temperature rise tests are reported on flat conductor cable installed under carpet and powered at up to twice rated loads.
In studies of fracture mechanics the adhesive fracture energy is regarded as a fundamental property of the adhesive system. It is pointed out that the value of the adhesive fracture energy depends on surface preparation, curing conditions, and absorbed monolayers. A test method reported makes use of a disk whose peripheral part is bonded to a substrate material. Pressure is injected into the unbonded central part of the disk. At a certain critical pressure value adhesive failure can be observed. A numerical stress analysis involving arbitrary geometries is conducted.
Consideration of the problem of ignition and combustion of structural materials, particularly metals, which may come in contact with oxygen during its production, transport, and use. Following a review of the historical development of compatibility problems and research, a detailed account is given of compatibility testing methods aimed at detecting probable ignition sources, such as mechanical impact, electric sparks or flashes, heat, sound waves, abrasion, and surface fractures. A summary is presented of the ignition and combustion research reported in the literature, dwelling particularly on papers concerning oxygen-related accidents and the compatibility of metals with high-pressure oxygen. The relative oxygen compatibility of a number of common materials is discussed, including that of nickel and copper alloys, stainless steels, aluminum alloys, and titanium alloys. Finally, an effort is made to pinpoint research areas which would enhance understanding of the compatibility of bulk materials.
Investigation of the application requirements, advantages, and limitations of nondestructive testing by a technique of ultrasonic-vibration holographic-interferometry readout used in a production control facility for the inspection of a single product such as composite compressor blades. It is shown that, for the detection and characterization of disbonds in composite material structures, this technique may represent the most inclusive test method.
Second- and third-order finite-difference methods recently applied to problems in high-speed fluid flow are applied to the model advection equation cast in conservative form. The differencing methods considered use forward time differencing with both centered and preferential space differences employed in the predictor-corrector sequences. The free parameter required for stability in the third-order method is adjusted to cause the solution to be either minimum dispersive or minimum dissipative in nature. Results indicate that the third-order method using minimum dispersion is the most accurate method tested. Computer time requirements are approximately twice those needed for second-order techniques.