Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Measuring Antineutrino Oscillations with the MINOS Experiment

MINOS is a long baseline neutrino oscillation experiment. A manmade beam of predominantly muon neutrinos is detected both 1 km and 735 km from the production point by two functionally identical detectors. A comparison of the energy spectra measured by the two detectors shows the energy-dependent disappearance of muon neutrinos characteristic of oscillations and allows a measurement of the parameters governing the oscillations. This thesis presents work leading to measurements of disappearance in the 6% $\bar{v}$ μ background in that beam. A calibration is developed to correct for time-dependent changes in the responses of both detectors, reducing the corresponding uncertainty on hadronic energy measurements from 1.8% to 0.4% in the near detector and from 0.8% to 0.4% in the far detector. A method of selecting charged current $\bar{v}$ μ events is developed, with purities (efficiencies) of 96.5% (74.4%) at the near detector, and 98.8% (70.9%) at the far detector in the region below 10 GeV reconstructed antineutrino energy. A method of using the measured near detector neutrino energy spectrum to predict that expected at the far detector is discussed, and developed for use in the $\bar{v}$ μ analysis. Sources of systematic uncertainty contributing to the oscillation measurements are discussed. In the far detector, 32 charged current $\bar{v}$ μ events are observed below a reconstructed energy of 30 GeV, compared to an expectation of 47.8 for Δ$\bar{m}$ atm 2 = Δ$\bar{m}$ atm 2 , sin 2 (2$\bar{θ}$ 23 ) = sin 2 (2θ 23 ). This deficit, in such a low-statistics sample, makes the result difficult to interpret in the context of an oscillation parameter measurement. Possible sources for the discrepancy are discussed, concluding that considerably more data are required for a definitive solution. Running MINOS with a dedicated $\bar{v}$ μ beam would be the ideal continuation of this work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutronics Analysis of TREAT Multi-SERTTA Calibration Test Vehicle (Multi-SERTTA CAL)

Transient testing is a necessary step in the performance evaluation of Accident Tolerant Fuels (ATF) developed as part of the Fuel Cycle Research and Development Advanced Fuels Campaign initiated and supported by the United States Department of Energy (DOE-NE). These advanced fuels are expected to be used in future reactors or replace the current fuel design used in existing power reactors for enhanced performance and safety. Upon completion of a process proscribed by the National Environmental Policy Act, the Transient Reactor Test (TREAT) facility, located at Idaho National Laboratory (INL), was chosen by DOE-NE to provide the desired specialized testing. TREAT has successfully operated from start-up in 1959 to 1994 when it was placed on operational stand-by. Careful preparations are being made for operational readiness and TREAT is projected to resume testing no later than 2018. Past TREAT testing primarily focused on sodium-cooled reactor fuels (SRF). Test vehicle designs varied to accommodate testing needs ranging from separate effects tests to integral tests approaching simulation of actual reactor environment conditions including forced convection cooling. The current focus on light water reactor (LWR) ATF requires design of new experiment vehicles to accommodate the water/steam environment and associated complexities regarding desired energy deposition into the specimen and proper containment. The first set of experiments in TREAT restart is expected to be conducted with the Multi-SERTTA (Static Environment Rodlet Transient Test Apparatuses). Difficult to quantify and calculate integral and time dependent effects inherent in transient testing limit predictive modeling capability; therefore, calibration testing in TREAT prior to the actual experiment is necessary to empirically determine the effectiveness of core-to-specimen power coupling in order to achieve the desired energy deposition into the test specimen during a nuclear power transient. This has been done in the past, in part, by evaluating the difference in energy deposition into dosimeter wires subjected to various TREAT time dependent power conditions. These calibration tests were typically conducted in a test vehicle neutronically similar to the actual test vehicle, but more simplistic in design in order to quickly retrieve and analyze dosimeter wires and minimize containment structure costs due to several trials. Prior calibration testing for SRF experiments could be conducted without coolant as sodium has no notable neutronic effect on the core-to-specimen power coupling factor (PCF). Such is not the case with LWR fuel where water serves as both moderator and coolant. This presents a design challenge as the calibration test vehicle must retain heated, high-pressure water to preserve neutronic equivalence representative of near prototypic reactor conditions while allowing for quick retrieval of dosimeters. The solution to this challenge comes in the form of a thin walled dry well positioned through the center of the basic Multi-SERTTA design. Test vehicle reactivity worth and PCF are two important factors with respect to ascertainment of neutronic equivalence. Similarity in test vehicle reactivity worth is desired to avoid the need to change operational core rod positions in TREAT which could significantly alter neutron flux distribution and consequently power distribution throughout the core and into the test specimen. The geometry and composition of various materials within the experiment containment structure can also significantly alter the quality of neutron signal delivery from the core to the test specimen. Introduction of an Inconel tube, albeit very thin, is expected to impact PCF. Simple modifications to the CAL design may compensate for the anticipated change. Evaluation of these factors and proposed modifications through neutronics analysis serves to inform experiment design and is a valuable tool towards achieving the optimal CAL design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Inter-Calibrating CERES Instrument Fluxes Utilizing the CERES Instrument Geostationary Scan Mode Observations

The NASA Clouds and the Earth’s Radiant Energy System (CERES) project provides the scientific community observed top-of-atmosphere (TOA) fluxes to monitor the Earth’s energy imbalance and validate climate models. The CERES instruments onboard the Terra, Aqua, SNPP and NOAA-20 satellites need to be inter-calibrated to provide a continuous and consistent TOA flux record contained in the CERES Energy Balanced and Filled (EBAF) product. The SNPP and NOAA-20 satellites are positioned a half an orbit apart within the same sun-synchronous orbit (1:30 PM equatorial crossing time) thus preventing any direct time-matched observations. The CERES project designed the geostationary scan mode (GEOscan) to inter-calibrate the Geostationary Earth Radiation Budget (GERB) broadband measurement onboard the Meteosat 8-11 satellites. By rotating the orientation of the CERES instrument scan to match the angular configuration of the geostationary scan mode, the comparison of both angle and time matched observations suitable for inter-calibration is possible. To determine if the GEOscan mode is useful for inter-calibrating two CERES instruments placed in the same 16-day repeating orbit, the CERES project placed the Terra and Aqua CERES instruments in GEOscan mode once every 6 days over a rotation of five geostationary domains beginning in February 2023. The GEO imager narrowband to broadband derived radiances are used as transfer radiometers to compare the Terra and Aqua CERES observed radiances. Since both the Terra and Aqua CERES instruments are in GEOscan mode over the same GEO domain and day, the GEO imager calibration is expected to be consistent between the Terra and Aqua overpass times. Any GEO imager narrowband to broadband regional biases should be similar for the Terra and Aqua overpasses. The GEOscan mode Terra and Aqua CERES inter-calibration coefficients for both shortwave and longwave broadband radiances will be compared against the CERES instrument team’s coefficients to determine the viability of this approach. Improvements in the GEO imager narrowband to broadband approaches will also be investigated and verified within this framework.

Kyle Itterly↗

High Performance Computing Traffic Simulations for Real-Time Traffic Control of Mobility in Chattanooga Region

In 2019, highway congestion wasted over 3 billion gallons of fuel and caused 8.8 billion hours of lost productivity.1 Research has shown that introducing near-real time traffic controls can significantly reduce congestion. Validated and calibrated traffic simulations enable the modeling of transportation systems and the evaluation of different traffic control actions and schemes given a variety of circumstances that represent likely future scenarios. The developed scenarios can inform the deployment of controls in near real-time to improve freight and passenger vehicle congestion and energy use. In this work, we present simulations used to model the traffic in the Chattanooga, Tennessee, metropolitan area. Simulations were constructed and calibrated using a variety of local, data science enhanced, data sources utilizing open source software including the Simulation of Urban Mobility (SUMO) simulator. High-Performance Computing (HPC) provides a scalable platform with enough computing for the high-fidelity simulation of many scenarios and the application of advance data science especially for large-scale systems. Our simulations include microscopic simulations at a corridor level for traffic signal control, and mesoscopic simulations to evaluate regional operational controls and infrastructure.

97 MATHEMATICS AND COMPUTING↗

THE VARIABILITY OF SAGITTARIUS A* AT 3 MILLIMETER

We have performed monitoring observations of the 3 mm flux density toward the Galactic center compact radio source Sagittarius A* (Sgr A*) with the Australia Telescope Compact Array since 2005 October. Careful calibrations of both elevation-dependent and time-dependent gains have enabled us to establish the variability behavior of Sgr A*. Sgr A* appeared to undergo a high and stable state in the 2006 June session, and a low and variable state in the 2006 August session. We report the results, with emphasis on two detected intraday variation events during its low states. One is on 2006 August 12 when Sgr A* exhibited a 33% fractional variation in about 2.5 hr. The other is on 2006 August 13 when two peaks separated by about 4 hr, with a maximum variation of 21% within 2 hr, were seen. The observed short timescale variations are discussed in light of two possible scenarios, i.e., the expanding plasmon model and the sub-Keplerian orbiting hot spot model. The fitting results indicate that for the adiabatically expanding plasmon model, the synchrotron cooling cannot be ignored, and a minimum mass-loss rate of 9.7 x 10{sup -10} M{sub sun} yr{sup -1} is obtained based on parameters derived for this modified expanding plasmon model. Simultaneous multiwavelength observation is crucial to our understanding of the physical origin of rapid radio variability in Sgr A*.

99 GENERAL AND MISCELLANEOUS↗

Streaked optical pyrometer for proton-driven isochoric heating experiments of solid and foam targets

We have designed, built, and calibrated an ultrafast streaked optical pyrometer (SOP) with ~5 ps resolution for measuring the time-resolved surface blackbody temperature of an isochorically heated plasma. The pyrometer is calibrated to measure temperatures from 0.5 eV to 25 eV, with the option of adding calibrated neutral density filters to observe hotter plasmas. We demonstrated the use of this pyrometer on isochoric heating experiments using laser-accelerated proton beams as an energy source at the $f$ /40 beamline of the Texas Petawatt Laser. We used the large focal spot size (~80 μm radius) of the $f$ /40 pulses to accelerate high numbers of ~MeV protons off 5 μm thick solid gold targets. During our experimental campaign, we heated 10 μm thick aluminum foil targets to 1–10 eV over a duration of 50 ps and also observed heating to ~2 eV in 100 μm thick 60 mg/cm 3 carbon foams using the SOP to measure both the temperature and heating timescale.

Equations of state↗

Chandra Observations of the Young Cluster NGC 2516

The Chandra observatory was Launched July 23 1999. The first two months of the mission have been spent performing on-orbit calibration. This phase of the mission has included about 60 Ks of observing time on the young cluster NGC 2516. The observations have been made as part of the measurements of the boresight and the plate-scale of the various instruments. These observations will augment planned (deeper) GTO observation of this cluster. Here we present the results of these early observations. As of September 7, in a single ACIS 5'x5' field (one backside chip) examined 26 sources were detected in a single 10 Ks exposure. This represents less than one sixth of the total exposure time and less than one sixth of the total area to be observed during the calibration phase. we will compare the characteristics of those sources detected with Chandra with those detected by ROSAT. Since these observations are being made using all detectors, we will also compare observations among the various detectors.

Wolk, Scott J.↗

Assessing the Calibration Differences in the Reflective Solar Bands of Terra MODIS and Landsat-7 Enhanced Thematic Mapper Plus

Long-term data records obtained from Earth observing sensors depend not only onthe calibration accuracy of individual sensors but also on the consistency across instruments andplatforms. Hence, sensor calibration intercomparison plays a vital role for a better understandingof various science products. The Moderate Resolution Imaging Spectroradiometer (MODIS)and enhanced thematic mapper plus (ETM+) on the Terra and Landsat 7 platforms have operatedsuccessfully since their launch, collecting measurements in the reflective solar and infrared partsof the spectrum. Terra MODIS has employed a reflectance-based calibration since beginning itsmission. In the case of ETM+, a radiance-based calibration was employed until recent years,when a reflectance-based calibration was introduced. Being in the AM constellation with lessthan 30 min difference in overpass times, near-simultaneous Earth scene measurements can beeffectively used to assess the calibration differences between the spectrally matching bands ofthese two instruments. The pseudoinvariant calibration sites (PICS) in the North African desertare widely used for on-orbit calibration and validation of satellite sensors. Four PICS from thisregion have been employed to assess the multitemporal reflectance differences. Correction forbidirectional reflectance, spectral response function mismatch, and impacts of atmosphericwater-vapor have been incorporated to provide an assessment of the long-term stability ofeach spectral band and reflectance differences amongst them. Results indicate that the spectralbands of both instruments show a long-term stability to within 2% from 2000 to 2017. Thetop-of-atmosphere reflectances between the two instruments postcorrection agree to within 4%.Also included in this paper is a detailed discussion of various parameters contributing to theuncertainties of this cross-calibration. The techniques presented in this paper can be furtherextended to perform similar intercomparison between Landsat 8 Operational Land Imager, AquaMODIS, and Suomi-NPP VIIRS.

Angal, Amit↗

Continuous and fast calibration of the CMS experiment: design of the automated workflows and operational experience

The exploitation of the full physics potential of the LHC experiments requires fast and efficient processing of the largest possible dataset with the most refined understanding of the detector conditions. To face this challenge, the CMS collaboration has setup an infrastructure for the continuous unattended computation of the alignment and calibration constants, allowing for a refined knowledge of the most time-critical parameters already a few hours after the data have been saved to disk. This is the prompt calibration framework which, since the beginning of the LHC Run-I, enables the analysis and the High Level Trigger of the experiment to consume the most up-to-date conditions optimizing the performance of the physics objects. In the Run-II this setup has been further expanded to include even more complex calibration algorithms requiring higher statistics to reach the needed precision. This imposed the introduction of a new paradigm in the creation of the calibration datasets for unattended workflows and opened the door to a further step in performance. The paper reviews the design of these automated calibration workflows, the operational experience in the Run-II and the monitoring infrastructure developed to ensure the reliability of the service.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-213-02: Characterizing 3D Printing in the Fabrication of Variable Density Phantoms

Purpose: In this work, we present characterization, process flow, quality control and application of 3D fabricated low density phantoms for radiotherapy quality assurance. Methods: A Rostock delta 3D printer using polystyrene filament of diameter 1.75 mm was used to print geometric volumes of 2×2×1 cm{sup 3} of varying densities. The variable densities of 0.1 to 0.75 g/cm {sup 3} were created by modulating the infill. A computed tomography (CT) scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. The time required to print these volumes was also recorded. Using the calibration, two low density cones (0.19, 0.52 g/cm{sup 3}) were printed and benchmarked against commercially available phantoms. The dosimetric validation of the low density scaling of Anisotropic Analytical Algorithm (AAA) was performed by using a 0.5 g/cm{sup 3} slab of 10×10×2.4 cm{sup 3} with EBT3 GafChromic film. The gamma analysis at 3%/3mm criteria were compared for the measured and computed dose planes. Results: Analysis of the volume of air pockets in the infill resulted in a reasonable uniformity for densities 0.4 to 0.75 g/cm{sup 3}. Printed phantoms with densities below 0.4 g/cm{sup 3} exhibited a higher ratio of air to polystyrene resulting in large non-uniformity. Compared to the commercial inserts, good agreement was observed only for the printed 0.52 g/cm{sup 3} cone. Dosimetric comparison for a printed low density volume placed in-between layers of solid water resulted in >95% gamma agreement between AAA calculated dose planes and measured EBT3 films for a 6MV 5×5 cm{sup 2} clinical beam. The comparison showed disagreement in the penumbra region. Conclusion: In conclusion, 3D printing technology opens the door to desktop fabrication of variable density phantoms at economical prices in an efficient manner for the quality assurance needs of a small clinic.

60 APPLIED LIFE SCIENCES↗

Coupling localized Noah-MP-Crop model with the WRF model improved dynamic crop growth simulation across Northeast China

Croplands play a critical role in regulating the energy and moisture exchanges between the land surface and atmosphere. However, the interactions between cropland and climate are usually poorly represented due to a lack of detailed representation in crop types and field management. Here, we coupled the Noah-MP-Crop model with the state-of-the-art Weather Research and Forecasting (WRF) model to explore and evaluate the crop growth dynamics in response to climate variations across Northeast China. The default parameters of the crop model were not exactly suitable for the agricultural ecosystems in Northeast China. The detailed cropland distribution, and crop phenology parameters including growing degree days (GDD) and planting (harvesting) date were first created using multi-source remote sensing products and reanalysis data, and was then successfully used to simulate the growth and yield for corn and soybean and associated energy exchanges. We also optimized and calibrated other crop parameters using the time-series of the Moderate Resolution Imaging Spectroradiometer (MODIS) land surface products. The modified crop model substantially improved the simulation of crop growth, plant physiology, and biomass accumulation for both corn and soybean. Coupling the localized dynamic crop model into the WRF led to considerable decreases in the simulated mean-absolute-errors (MAEs) and biases of the leaf area index, evapotranspiration, and gross primary production compared with the MODIS observed values. Compared with the statistical yield from each province, the modified crop model underestimated the corn yield from 11.1% to 48.6%, whereas overestimated the soybean yield from 16.5% to 162.6%.

54 ENVIRONMENTAL SCIENCES↗

Sodium doping effect on physicochemical properties of K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1) for the determination of mercury(II): Application in seawater samples

Highlights: • The apatite, K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1), was synthesized using reaction solid. • The obtained apatite was used to determine mercury in seawater samples from Morocco. • The effect of doping sodium into apatite on physic-chemical parameters was studied. • The influence of the electrochemical variables was investigated to determine mercury. - Abstract: A new chemically modified electrode was synthesized for the determination of mercury(II) using differential pulse anodic stripping voltammetry (DPASV). The electrode was modified by lacunar apatite K{sub 1−x}Na{sub x}CaPb{sub 3}(PO{sub 4}){sub 3} (0 ≤ x ≤ 1) synthesized using solid reaction. These powders were crystallized in the hexagonal system, space group P6{sub 3}/m. The effect of sodium content on structural, thermodynamic and electrochemical properties of prepared apatite has been studied. Therefore, the best results was obtained using NaCaPb{sub 3}(PO{sub 4}){sub 3} (x = 1) as modifier of carbon paste electrode for the electrochemical detection of mercury(II). The later ions were preconcentrated on the surface of the modified electrode and oxidized at 0.06 V vs. Ag/AgCl. The electroanalytical procedure comprises of two steps: the chemical accumulation of the analyte under open-circuit conditions followed by the electrochemical detection of the preconcentrated species using differential pulse voltammetry. The different parameters that govern the two steps were optimized. A linear response was obtained in the concentration range from 1.0 mol L{sup −1} × 10{sup −4} mol L{sup −1} to 2.0 mol L{sup −1} × 10{sup −7} mol L{sup −1} Hg(II) after activation of the electrode surface under the optimized conditions. The standard deviation was evaluated in a high and low concentration of mercury(II). The values ​​obtained for seven consecutive measurements were 1.24% and 5.07% of 1.0 mol L{sup −1} × 10{sup −4} mol L{sup −1} and 5.0 mol L{sup −1} × 10{sup −6} mol L{sup −1} mercury(II) solutions respectively. The detection limit and quantification limit for mercury(II), calculated from nine times standard deviation of blank/slope of the calibration graph, were 1.086 mol L{sup −1} × 10{sup −8} mol L{sup −1} and 3.62 mol L{sup −1} × 10{sup −8} mol L{sup −1}, respectively. The proposed chemically modified electrode was applied to determine mercury(II) in seawater samples.

36 MATERIALS SCIENCE↗

LAB4D: A low power, multi-GSa/s, transient digitizer with sampling timebase trimming capabilities

The LAB4D is a new application-specific integrated circuit (ASIC) of the Large Analog Bandwidth Recorder and Digitizer with Ordered Readout (LABRADOR) family, for use in direct wideband radio frequency digitization such as is used in ultrahigh energy neutrino and cosmic ray astrophysics. The LAB4D is a single channel switched-capacitor array (SCA) 12-bit sampler with integrated analog-to-digital converters (ADC), developed in the TSMC 0.25um process. The LAB4D, operating at 3.2GSa/s, contains 4096 total samples arranged in 32 windows, for a total record length of 1280ns. The 3dB bandwidth is approximately 1.3GHz, with a directly-coupled 50ohm input. This represents a factor of 16 increase in the sample depth and an increase in analog bandwidth and sampling depth in comparison to the previous generation LAB3 digitizer. Individually addressable windows allow for sampling and digitization to occur simultaneously, leading to nearly deadtime-free readout for kHz readout rates. All biases and current references are generated via internal digital-to-analog converters (DACs), resulting in a stand-alone digitizer with no additional support circuitry. In addition, the LAB4D contains sample cell timebase trimming capabilities, reducing the intrinsic sample-to-sample time variance to less than 5ps; an improvement of about 80%. This allows the LAB4D to be used in precision timing applications with minimal post-hoc calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Database of pharmacokinetic time-series data and parameters for 144 environmental chemicals

Time courses of compound concentrations in plasma are used in chemical safety analysis to evaluate the relationship between external administered doses and internal tissue exposures. This type of experimental data is rarely available for the thousands of non-pharmaceutical chemicals to which people may potentially be unknowingly exposed but is necessary to properly assess the risk of such exposures. In vitro assays and in silico models are often used to craft an understanding of a chemical’s pharmacokinetics; however, the certainty of the quantitative application of these estimates for chemical safety evaluations cannot be determined without in vivo data for external validation. To address this need, we present a public database of chemical time-series concentration data from 567 studies in humans or test animals for 144 environmentally-relevant chemicals and their metabolites (187 analytes total). All major administration routes are incorporated, with concentrations measured in blood/plasma, tissues, and excreta. We also include calculated pharmacokinetic parameters for some studies, and a bibliography of additional source documents to support future extraction of time-series. In addition to pharmacokinetic model calibration and validation, these data may be used for analyses of diferential chemical distribution across chemicals, species, doses, or routes, and for meta-analyses on pharmacokinetic studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An experimental system for spectral line ratio measurements in the TJ-II stellarator

The chord-integrated emissions of spectral lines have been monitored in the TJ-II stellarator by using a spectral system with time and space scanning capabilities and relative calibration over the entire UV-visible spectral range. This system has been used to study the line ratio of lines of different ionization stages of carbon (C{sup 5+} 5290 A and C{sup 4+} 2271 A) for plasma diagnostic purposes. The local emissivity of these ions has been reconstructed, for quasistationary profiles, by means of the inversion Fisher method described previously. The experimental line ratio is being empirically studied and in parallel a simple spectroscopic model has been developed to account for that ratio. We are investigating whether the role played by charge exchange processes with neutrals and the existence of non-Maxwellian electrons, intrinsic to Electron Cyclotron Resonance Heating (ECRH) heating, leave any distinguishable mark on this diagnostic method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Consideration of the mechanism of microwave emission due to material destruction

Microwave emission due to material destruction by hypervelocity impact with several kilometers per second was found at 2 and 22 GHz, and its power was calibrated in the laboratory for the first time ever. In this paper, we first summarize the experimental results in relation to the mechanism of microwave emission. We then propose three kinds of hypotheses on the mechanism, which are based on the dynamic relative motion of an atom’s nucleus and the outermost electron and lead to dipole radiation. The deduced equation represents the power dependence on the target’s thickness, which agrees well with the experimental result. The models were then numerically analyzed in consideration of the experimental data. In the most promising model, a projectile molecule flicks the nucleus out and the outermost electron is left out of the orbit of the atom. Accordingly, the material is polarized or ionized to form an impulsive dipole, which leads to microwave emission. This model is compatible with material ionization by mechanical excitation, such as rubbing and peeling, or triboelectricity. The calculated energy shows good agreement with the experimental value. On the other hand, if the outermost electron remains within the gravity field of the nucleus, the calculated and experimental results do not agree with each other.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A CHANDRA ACIS STUDY OF THE YOUNG STAR CLUSTER TRUMPLER 15 IN CARINA AND CORRELATION WITH NEAR-INFRARED SOURCES

Using the highest-resolution X-ray observation of the Trumpler 15 star cluster taken by the Chandra X-ray Observatory, we estimate the total size of its stellar population by comparing the X-ray luminosity function (XLF) of the detected sources to a calibrator cluster and identify for the first time a significant fraction ({approx}14%) of its individual members. The highest-resolution near-IR observation of Trumpler 15 (taken by the HAWK-I instrument on the Very Large Telescope) was found to detect most of our X-ray selected sample of cluster members, with a K-excess disk frequency of 3.8% {+-} 0.7%. The near-IR data, XLF, and published spectral types of the brightest members support a cluster age estimate (5-10 Myr) that is older than those for the nearby Trumpler 14 and Trumpler 16 clusters, and suggest that high-mass members may have already exploded as supernovae. The morphology of the inner {approx}0.7 pc core of the cluster is found to be spherical. However, the outer regions (beyond {approx}2 pc) are elongated, forming an 'envelope' of stars that, in projection, appears to connect Trumpler 15 to Trumpler 14; this morphology supports the view that these clusters are physically associated. Clear evidence of mass segregation is seen. This study appears in this special issue devoted to the Chandra Carina Complex Project, a 1.42 deg{sup 2} Chandra X-ray survey of the Great Nebula in Carina.

79 ASTRONOMY AND ASTROPHYSICS↗

NINE-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE (WMAP) OBSERVATIONS: FINAL MAPS AND RESULTS

We present the final nine-year maps and basic results from the Wilkinson Microwave Anisotropy Probe (WMAP) mission. The full nine-year analysis of the time-ordered data provides updated characterizations and calibrations of the experiment. We also provide new nine-year full sky temperature maps that were processed to reduce the asymmetry of the effective beams. Temperature and polarization sky maps are examined to separate cosmic microwave background (CMB) anisotropy from foreground emission, and both types of signals are analyzed in detail. We provide new point source catalogs as well as new diffuse and point source foreground masks. An updated template-removal process is used for cosmological analysis; new foreground fits are performed, and new foreground-reduced CMB maps are presented. We now implement an optimal C {sup –1} weighting to compute the temperature angular power spectrum. The WMAP mission has resulted in a highly constrained ΛCDM cosmological model with precise and accurate parameters in agreement with a host of other cosmological measurements. When WMAP data are combined with finer scale CMB, baryon acoustic oscillation, and Hubble constant measurements, we find that big bang nucleosynthesis is well supported and there is no compelling evidence for a non-standard number of neutrino species (N {sub eff} = 3.84 ± 0.40). The model fit also implies that the age of the universe is t {sub 0} = 13.772 ± 0.059 Gyr, and the fit Hubble constant is H {sub 0} = 69.32 ± 0.80 km s{sup –1} Mpc{sup –1}. Inflation is also supported: the fluctuations are adiabatic, with Gaussian random phases; the detection of a deviation of the scalar spectral index from unity, reported earlier by the WMAP team, now has high statistical significance (n{sub s} = 0.9608 ± 0.0080); and the universe is close to flat/Euclidean (Ω{sub k} = -0.0027{sup +0.0039}{sub -0.0038}). Overall, the WMAP mission has resulted in a reduction of the cosmological parameter volume by a factor of 68,000 for the standard six-parameter ΛCDM model, based on CMB data alone. For a model including tensors, the allowed seven-parameter volume has been reduced by a factor 117,000. Other cosmological observations are in accord with the CMB predictions, and the combined data reduces the cosmological parameter volume even further. With no significant anomalies and an adequate goodness of fit, the inflationary flat ΛCDM model and its precise and accurate parameters rooted in WMAP data stands as the standard model of cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗