At least 1,045 records · Page 58

Verification study of an emerging fire suppression system

Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Moreover, plutonium gloveboxes present harsh environmental conditions for polymer materials; these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. Several studies have been conducted to determine the robustness of selfcontained fire extinguishers in plutonium gloveboxes in a nuclear facility, verification tests must be performed. These tests include activation and mass loss calorimeter tests. In addition, compatibility issues with chemical components of the self-contained fire extinguishers need to be addressed. Our study presents activation and mass loss calorimeter test results. After extensive studies, no critical areas of concern have been identified for the plutonium glovebox application of Fire Foe™, except for glovebox operations that use large quantities of bulk plutonium or uranium metal such as metal casting and pyro-chemistry operations.

42 ENGINEERING↗

Code verification for practically singular equations

We report the method-of-moments implementation of the electric-field integral equation (EFIE) yields many code-verification challenges due to the various sources of numerical error and their possible interactions. Matters are further complicated by singular integrals, which arise from the presence of a Green's function. To address these singular integrals, an approach is presented in wherein both the solution and Green's function are manufactured. Because the arising equations are poorly conditioned, they are reformulated as a set of constraints for an optimization problem that selects the solution closest to the manufactured solution. In this paper, we demonstrate how, for such practically singular systems of equations, computing the truncation error by inserting the exact solution into the discretized equations cannot detect certain orders of coding errors. On the other hand, the discretization error from the optimal solution is a more sensitive metric that can detect orders less than those of the expected convergence rate.

97 MATHEMATICS AND COMPUTING↗

Weekly Verification of Dosimetric Data for Virtual Wedge Using a 2D Diode Detector Array

A linac manufacturer has recommended that users measure virtual wedge (VW) angle and VW factor as a weekly quality assurance (QA) procedure. The purpose of this study was to investigate whether a 2D diode detector array (MapCHECK{sup TM}) is a useful tool for the verification of dosimetric data for VW. Measurements were performed on 2 linear accelerators (4, 6, and 10 MV) at 10-cm depth for a field size of 10 x 10 cm{sup 2} and with wedge angles of 15, 30, 45, and 60{sup o}. To verify the VW dose distributions generated by the treatment planning system (TPS), we confirmed that agreement between TPS data and measurements were {<=}2% dose difference or 2-mm distance-to-agreement based on American Association of Physicists in Medicine Task Group Report 53 (AAPM TG-53). We present here the results of a 1-year evaluation of VW by means of a 2D diode detector array. The maximum 2-fold standard deviation of the measured wedge angle turned out to be within 1.0, and all measured VW factors to be 1.00 {+-} 0.03. Although >95% of the points measured for 6 and 10 MV were generally within the tolerance of the dose distribution as mentioned above, the percentage of agreement between the measured data for 4 MV and TPS data were somewhat below 90%. We also verified generally good reproducibility for the dose distribution. The 2-D diode detector array was thus found to be useful as a tool for weekly VW QA.

61 RADIATION PROTECTION AND DOSIMETRY↗

A comparison between radiation therapists and medical specialists in the use of kilovoltage cone-beam computed tomography scans for potential lung cancer radiotherapy target verification and adaptation

Target volume matching using cone-beam computed tomography (CBCT) is the preferred treatment verification method for lung cancer in many centers. However, radiation therapists (RTs) are trained in bony matching and not soft tissue matching. The purpose of this study was to determine whether RTs were equivalent to radiation oncologists (ROs) and radiologists (RDs) in alignment of the treatment CBCT with the gross tumor volume (GTV) defined at planning and in delineating the GTV on the treatment CBCT, as may be necessary for adaptive radiotherapy. In this study, 10 RTs, 1 RO, and 1 RD performed a manual tumor alignment and correction of the planning GTV to a treatment CBCT to generate an isocenter correction distance for 15 patient data sets. Participants also contoured the GTV on the same data sets. The isocenter correction distance and the contoured GTVs from the RTs were compared with the RD and RO. The mean difference in isocenter correction distances was 0.40 cm between the RO and RD, 0.51 cm between the RTs, and RO and 0.42 cm between the RTs and RD. The 95% CIs were smaller than the equivalence limit of 0.5 cm, indicating that the RTs were equivalent to the RO and RD. For GTV delineation comparisons, the RTs were not found to be equivalent to the RD or RO. The alignment of the planning defined GTV and treatment CBCT using soft tissue matching by the RTs has been shown to be equivalent to those by the RO and RD. However, tumor delineation by the RTs on the treatment CBCT was not equivalent to that of the RO and RD. Thus, it may be appropriate for RTs to undertake soft tissue alignment based on CBCT; however, further investigation may be necessary before RTs undertake delineation for adaptive radiotherapy purposes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental demonstration and modeling of a robotic neutron detector with spectral and directional sensitivity for treaty verification

International safeguards and arms control agreements often require labor-intensive, intrusive onsite inspections to perform verification tasks. The ability to localize a neutron source and/or characterize a neutron field may be imperative for identifying anomalies. We are interested in the role of autonomous mobile robots, which, if designed properly, may be more effective and efficient and less intrusive than their human counterparts. Toward developing such a capability, we, for this study, have constructed the N-SpecDir Bot, comprised of three boron-coated straw detectors azimuthally-distributed within a cylinder of high-density polyethylene, which is mounted on an omni-directional robotic platform. Our N-SpecDir Bot is specifically designed to provide spectral and directional sensitivity, in addition to gross counts, by utilizing the signals from the three detectors. The detection system has been extensively characterized by MCNP modeling, which has been benchmarked to experiments conducted at the Princeton Plasma Physics Laboratory. We demonstrate the spectral and directional sensitivity experimentally and in simulation, and provide a simple yet robust method for directional measurements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Optimizing a detection system for fissile material in nuclear disarmament verification

In arms control treaties, verification plays a crucial role in detecting non-compliance, deterring future violations, and building trust between state parties. Neutron interrogation that induces fission reactions in fissile isotopes and measures the resulting fission neutrons, could be employed for this purpose. This study aims to develop a system which can determine the presence of fissile material while intrinsically protecting information. In this paper, we focus on optimizing the system for discriminating between an enriched uranium block from a depleted uranium (DU) block. The system was built and we report on benchmark measurements with DU and 16% enriched uranium blocks. Furthermore, the Excalibur (Experiment for Calibration with Uranium) neutron source, a neutron spectrometer (redBubble Technology Industries (BTI) N-Probe), and superheated droplet detectors were used for these measurements. MCNP simulations provided insights into detector responses to fissile materials with varying isotopic compositions, confirming that the system functioned as designed.

Active neutron interrogation↗

Simulation Of Human Body Radiation Using Phantom Model On Beam lowbar nrc And Verification On Dosxyz lowbar nrc

The optimum dose can be produced by measuring and analysis of the dose distribution from the source. The energy of the source must be maximum for the target cell, and must minimum for the tissues that surround the target cell. In this study, the phantom model has a cylindrical shape with 20 cm radius and 19 cm depth. The calculation is done where photon beam energy is 6 MeV with 3 different radius beam; 0.3 cm, 5 cm, and 15 cm. The verification was done with a model cube film which was arranged by element voxel which made by Mylar and Ag. The results of this simulation shows the difference dose distribution for radius beam 0.5 cm, 3 cm, and 15 cm that is caused by particle density and penumbra effect. And for all beam radiuses, the maximum dose (100%) happens in 1.5-2 mm depth from film model.

07 ISOTOPE AND RADIATION SOURCES↗

Dose Verification in IMRT and VMAT

This is a review paper of the current IMRT dosimetric verification methods, with the emphasis on the solid state dosimeters. Different types of IMRT treatments and the associated quality assurance challenges are described. The prevailing techniques of quantifying dosimetric agreement and their weaknesses in terms of clinical relevance are discussed. A variety of empirical, semi-empirical, and purely calculational methods are summarized from a clinical practice point of view. A number of available commercial devices and emerging technologies are described.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental verification of the Boltzmann relation in confined plasmas: Comparison of noble and molecule gases

Experimental verification of the Boltzmann relation is performed in argon and oxygen gas inductively coupled plasmas from the measurements of both the spatial electron currents (as a fluid approach) and the electron energy probability functions (EEPFs, as a kinetic approach). At a low gas pressure of 10 mTorr, the measured electron currents are spatially uniform, and the EEPFs in the total electron energy scale are identical, which indicate that the Boltzmann relation is valid at both the argon and oxygen gases. As the gas pressure increases to 30-40 mTorr, however, the Boltzmann relation is broken in the oxygen gas discharge, while the Boltzmann relation is still valid in the argon gas discharge. This different variation in the oxygen gas discharge is mainly due to the presence of various inelastic collisions in the entire electron energy region, which causes the transition of the electron kinetics from a non-local to a local regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of daily detector verification data for isotopical half-life determination

In this work, the possibility of using data fromthe daily detector verification routines performed at the Neutron Activation Laboratory of IPEN to determine precise values for the half-lives of {sup 57}Co and {sup 60}Co was evaluated. For this purpose data from 4 of the laboratory's detectors, some spanning for more than 9 years, were inspected, separated in consistent groups, and then analyzed using a robust least-squares fit procedure in order to determine the half-lives. The results allowed for a discussion on the possibilities and limitations of the use of these data for the determination of half-lives.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Establishment and experimental verification of the photoresist model considering interface slip between photoresist and concave spherical substrate

A thickness distribution model of photoresist spin-coating on concave spherical substrate (CSS) has been developed via both theoretical studies and experimental verification. The stress of photoresist on rotating CSS is analyzed and the boundary conditions of hydrodynamic equation are presented under the non-lubricating condition. Moreover, a multivariable polynomial equation of photoresist-layer thickness distribution is derived by analyzing and deducing the flow equation where the evaporation rate, substrate topography, interface slip between liquid and CSS, and the variation of rotational speed and photoresist parameters are considered in detail. Importantly, the photoresist-layer thickness at various CSS rotational speeds and liquid concentrations can be obtained according to the theoretical equation. The required photoresist viscosity and concentration parameters of different photoresist coating thickness under a certain coating speeds can be also solved through this equation. It is noted that the calculated theoretical values are well consistent with the experimental results which were measured with various CSS rotational speeds and liquid concentrations at steady state. Therefore, both our experimental results and theoretical analysis provide the guidance for photoresist dilution and pave the way for potential improvements and microfabrication applications in the future.

36 MATERIALS SCIENCE↗

Calibrations and verifications performed in view of the ILA reinstatement at JET

The calibrations and verifications that are performed in preparation of the ITER-Like antenna (ILA) reinstatement at JET are reviewed. A brief reminder of the ILA system layout is given. The different calibration methods and results are then discussed. They encompass the calibrations of the directional couplers present in the system, the determination of the relation between the capacitor position readings and the capacitance value, the voltage probes calibration inside the antenna housing, the RF cables characterization and the acquisition electronics circuit calibration. Earlier experience with the ILA has shown that accurate calibrations are essential for the control of the full ILA close-packed antenna array, its protection through the S-Matrix Arc Detection and the new second stage matching algorithm to be implemented. Finally the voltage stand-off of the capacitors is checked and the phase range achievable with the system is verified. The system layout is modified as to allow dipole operation over the whole operating frequency range when operating with the 3dB combiner-splitters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and verification of distributed logic controllers with application of Petri nets

The paper deals with the designing and verification of distributed logic controllers. The control system is initially modelled with Petri nets and formally verified against structural and behavioral properties with the application of the temporal logic and model checking technique. After that it is decomposed into separate sequential automata that are working concurrently. Each of them is re-verified and if the validation is successful, the system can be finally implemented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental verification of the capillary plasma triggered long spark gap under the extremely low working coefficient in air

The paper has proposed a new triggering method for long spark gap based on capillary plasma ejection and conducted the experimental verification under the extremely low working coefficient, which represents that the ratio of the spark gap charging voltage to the breakdown voltage is particularly low. The quasi-neutral plasma is ejected from the capillary and develops through the axial direction of the spark gap. The electric field in the spark gap is thus changed and its breakdown is incurred. It is proved by the experiments that the capillary plasma ejection is effective in triggering the long spark gap under the extremely low working coefficient in air. The study also indicates that the breakdown probabilities, the breakdown delay, and the delay dispersion are all mainly determined by the characteristics of the ejected plasma, including the length of the plasma flow, the speed of the plasma ejection, and the ionization degree of the plasma. Moreover, the breakdown delay and the delay dispersion increase with the length of the long spark gap, and the polarity effect exists in the triggering process. Lastly, compared with the working patterns of the triggering device installed in the single electrode, the working pattern of the devices installed in both the two electrodes, though with the same breakdown process, achieves the ignition under longer gap distance. To be specific, at the gap length of 14 cm and the working coefficient of less than 2%, the spark gap is still ignited accurately.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Verification of BOUT++ by the method of manufactured solutions

BOUT++ is a software package designed for solving plasma fluid models. It has been used to simulate a wide range of plasma phenomena ranging from linear stability analysis to 3D plasma turbulence and is capable of simulating a wide range of drift-reduced plasma fluid and gyro-fluid models. A verification exercise has been performed as part of a EUROfusion Enabling Research project, to rigorously test the correctness of the algorithms implemented in BOUT++, by testing order-of-accuracy convergence rates using the Method of Manufactured Solutions (MMS). We present tests of individual components including time-integration and advection schemes, non-orthogonal toroidal field-aligned coordinate systems and the shifted metric procedure which is used to handle highly sheared grids. The flux coordinate independent approach to differencing along magnetic field-lines has been implemented in BOUT++ and is here verified using the MMS in a sheared slab configuration. Finally, we show tests of three complete models: 2-field Hasegawa-Wakatani in 2D slab, 3-field reduced magnetohydrodynamics (MHD) in 3D field-aligned toroidal coordinates, and 5-field reduced MHD in slab geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calculation and experimental verification of a collimator with a Kerr lens for fibre laser mode locking

We present the calculation and experimental verification of the operation of a collimator coupling a light beam into an optical fibre with an As{sub 2}S{sub 3} nonlinear plate. It is shown that a Kerr lens formed in the plate with an increase in the peak pulse power leads to an increase in the output coupling ratio by about 15%, which can be used for the passive mode locking of a fibre laser. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental demonstration of an isotope-sensitive warhead verification technique using nuclear resonance fluorescence

Significance We present an experimental demonstration of an isotope-sensitive warhead verification protocol. The measurement is capable of detecting tampering with a warhead’s material or geometry with high statistical confidence in realistically attainable measurement times, while simultaneously protecting sensitive warhead design information. Such a protocol could enable the verifiable elimination of nuclear warheads under a future arms reduction treaty.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗