Wall-modeled LES of the Three-dimensional Speed Bump Experiment

We evaluate the performance of wall-modeled large eddy simulation (WMLES) in predicting smooth-body turbulent flow separation for a three-dimensional Gaussian-shaped speed bump geometry. The Reynolds number based on the bump length is 2 million, and an unstructured compressible finite-volume solver is used with an equilibrium wall model and dynamic subgrid scale model. Spanwise periodic simulations of the centerline two-dimensional bump were used to assess grid resolution requirements, and resolving the thin internal layer in the accelerating region was found to be necessary to correctly capture the downstream separated flow region. Based on these insights, an optimized grid that was smaller by a factor of two provided comparable accuracy to a finer grid that has been used by us and other researchers in past studies. Using insights gained from the spanwise periodic simulation, an unstructured polyhderal grid with about 250 million cells was used for the three-dimensional (3D) configuration with inviscid tunnel side and top walls. Detailed comparisons of wall skin-friction coefficient, wall pressure, velocity and turbulent stresses with available experimental data indicated excellent agreement. While the low-Reynolds Number Spalart-Allmaras RANS model with rotation/curvature correction gave qualitatively good agreement with experiments, WMLES showed significantly more accurate quantitative predictions of the flowfield. The 3D WMLES showed good agreement with experiments in the separated region, and the centerplane results indicated a different separation topology compared to the spanwise periodic simulation.

Computational Fluid Dynamics↗

Discrete and Continuum Plane-Hopper Flow Simulations with Experimental Validation Using X-Ray Imaging, Arch Profilometry and Wall Pressure Measurements

The flow of spherical glass beads, approximately cubic wood crumbles®, and wood microchips are investigated using a combination of discrete element modeling (DEM), finite element analysis (FEA), and physical experiments using a custom plane-flow hopper in which the flow is characterized using x-ray imaging, profilometry to measure arching geometry and pressure measurements at the wall. The purpose of this study is to investigate fundamental flow behavior, and for this purpose the simulations and physical tests are specially designed. During the physical tests and simulations, the hopper geometry begins as a V shape with the two opposing side walls touching at the bottom of the V. Basic tests are performed by first filling the hopper with material, and then rotating the opposing side walls inward about their common intersection axis to cause an approximately uniform stress condition throughout most of the hopper. The side walls then slide upward to effectively increase the size of the opening at the bottom of the hopper until the arch of material in the hopper breaks, and all of the material falls out of the hopper. More advanced tests are also performed in which the initial rotation of the walls is slightly reversed to decrease the pressure in the hopper, corresponding to “preshear” and “shear” conditions in standard shear tests. Shear tests of the materials are also performed using a Schulze automated ring shear tester with a standard size M shear cell, and the shear tests of the glass beads and wood crumbles® are also simulated using DEM to calibrate the DEM with the FEA. Reasonable agreement between predicted and measured flow behavior is obtained indicating that this type of physical tests and modeling shows promise for characterizing and predicting the flow behavior of compressible and anisotropic materials.

09 BIOMASS FUELS↗

MODELING AND SIMULATIONS OF DETERIORATED TURBULENT HEAT TRANSFER IN WALL HEATED CYLINDRICAL TUBE

The paper discusses the modeling and simulations of Deteriorated Turbulent Heat Transfer (DTHT) for a wall-heated fluid flows, which can be observed in gas-cooled nuclear power reactors during Pressurized Conduction Cooldown (PCC) event due to loss of force circulation flow. The DTHT regime is defined as the deterioration of normal turbulent heat transport due to increase of acceleration and buoyancy forces. The Computational Fluid Dynamics (CFD) tools such as Nek5000 and STAR-CCM+ can help to analyze the DTHT phenomena in reactors for efficient thermal-fluid designs. 3D CFD non-isothermal modeling and simulations were performed in a wall-heated circular tube. The simulation results were verified with two different CFD tools, Nek5000 and STAR-CCM+, and validated with an experimental data. The predicted bulk temperatures were identical in both CFD tools, as expected. Good agreement between simulated results and measured data were obtained for wall temperatures along the tube axis using Nek5000. In STAR-CCM+, the under-predicted wall temperatures were mainly due to higher turbulence in the wall region. In STAR-CCM+, the predicted DTHT was over 48% at outlet when compared to inlet heat transfer values.

deteriorated turbulent heat transfer↗

Methods for degrading or converting plant cell wall polysaccharides

The present invention relates to methods for converting plant cell wall polysaccharides into one or more products, comprising: treating the plant cell wall polysaccharides with an effective amount of a spent whole fermentation broth of a recombinant microorganism, wherein the recombinant microorganism expresses one or more heterologous genes encoding enzymes which degrade or convert the plant cell wall polysaccharides into the one or more products. The present invention also relates to methods for producing an organic substance, comprising: (a) saccharifying plant cell wall polysaccharides with an effective amount of a spent whole fermentation broth of a recombinant microorganism, wherein the recombinant microorganism expresses one or more heterologous genes encoding enzymes which degrade or convert the plant cell wall polysaccharides into saccharified material; (b) fermenting the saccharified material of step (a) with one or more fermenting microoganisms; and (c) recovering the organic substance from the fermentation.

09 BIOMASS FUELS↗

Airfoil having internally cooled wall with liner and shell

An airfoil includes an airfoil section that has an airfoil wall that surrounds a cavity. The airfoil wall includes a first wall section comprised of a monolithic ceramic shell, a second wall section comprised of a CMC liner that is bonded along an interface to an interior side of the monolithic ceramic shell, and a ceramic barrier coating that is bonded to an exterior side of the monolithic ceramic shell. The airfoil wall includes at least one of: inter-section cooling channels that extend along the interface and are bounded by the monolithic ceramic shell and the CMC liner, or intra-section cooling channels that extend within the CMC liner.

Croteau, Paul F.↗

Design, Construction, and Field Validation of a Blown-In Fiberglass Wall System in a Cold, Wet, and Windy Climate

In the Native Village of Tununak, located on Nelson Island in Southwest Alaska,buildings are exposed to wind-driven rain and snow throughout the year. The Cold Climate Housing Research Center (CCHRC) and Knauf Insulation partnered with the community in 2018 to design a residence for a public safety officer. Construction began in fall 2021 and is scheduled to conclude in summer 2022. The house will use integrated trusses with floor, attic, and wall cavities filled with blown-in fiberglass insulation. Hygrothermal models of the building envelope system demonstrate that the high ambient moisture load will wet the outer edges of the insulation annually regardless of the extent and integrity of exterior weather sealing measures; blown-in fiberglass is expected to be more resilient to this wetting than blown-in cellulose. To verify this, researchers will embed temperature, relative humidity, and moisture sensors in the two windward walls of the house to monitor the ability of the blown-in fiberglass insulation to dry out after wetting events that may have occurred during the transport of the insulation to the building site, storage of the insulation on site, construction process, or after installation in the wall. Sensors will remain in place for two years,documenting the wall's performance over time and verifying the design's potential for use in buildings located in climates where the chance for moisture damage is high. Here, we describe the wall system , design criteria, and the results from the hygrothermal modeling. We share details on the monitoring system's components and the planned management and analysis of data. Finally, we explain how the experiences and data from this project will inform future builds in similar locations.

building design↗

Preliminary high-fidelity simulation of duct wall deformation in sodium fast reactor subassembly

Computational Fluid Dynamics simulations of nuclear energy systems have received extensive interest and have achieved a certain level of maturity. This gives opportunities for a more realistic mechanical analysis of a sodium fast reactor subassembly that is based on more accurate estimates of pressure and temperature distributions within a subassembly. In fast reactor systems, important reactivity feedbacks can be a result of such subassembly duct wall deformation, with an impact on reactor safety considerations. The structural analysis in this work focuses on the stress-strain distributions in a fast reactor subassembly duct wall that are the result of pressure and temperature gradients across the duct. The RANS-based commercial CFD software STAR-CCM+ was used to perform the structural analysis of the duct wall in a 61-pin subassembly that was irradiated in EBR-II as a lead test subassembly. A loose coupling was performed for the thermal-hydraulics and structural mechanics to reduce the mesh cell number and computation time. It is found that the duct wall displacements are dominated by the thermal expansion, but the stress distributions are dominated by the pressure gradients between the inside and outside of the duct. However, the predicted stresses were far less than the yield stress, indicating large margin to the structural integrity of the non-irradiated duct wall. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparative study of glow discharge wall conditioning using H{sub 2} and Ar-H{sub 2} gas mixture of ADITYA Tokamak vacuum vessel

Low temperature glow discharge wall conditioning (GDC) using H{sub 2} gas is effective in reduction of oxygen and carbon (low-Z) contain impurities on near surface region of vessel wall. The high retention of hydrogen in vessel wall/components due to long operation of H{sub 2} GDC increases hydrogen out-gassing during tokamak operation and affects the production of high temperature plasma. The hydrogen retention can be reduced using inert gas GDC by sputter cleaning for short duration. But in that case the out-gassing rate of inert gas increases, that again impairs the plasma performance. To overcome above problems, the GDC with hydrogen-inert gas mixture can be used for better removal of C and O surface contaminants and low hydrogen retention in surface. In ADITYA tokamak, H{sub 2}-GDC is carried out regularly after plasma operation, while the GDC with argon-hydrogen (Ar-H{sub 2}) mixture has been experimentally tested to observe the reduction of oxygen and carbon impurities along with low hydrogen retention. In Ar-H{sub 2} GDC, the reason being the formation of ArH{sup +} hydride ions, which has quite long life and more energy compared to H{sub 2}{sup +} ions formed in H{sub 2} GDC for breaking the bond of wall molecules. A systematic comparative study of H{sub 2} GDC and Ar-H{sub 2} Mixture GDC by changing the mixture ratio has been carried out in ADITYA tokamak. The relative levels of oxygen and carbon contain impurities have been measured using residual gas analyzer in both GDC's. We have observed a substantial reduction in oxygen and carbon impurities with a significant improvement in wall condition with Ar-H{sub 2} GDC compared to the H{sub 2} GDC. The effect of wall conditioning by Ar-H{sub 2} GDC on the performance of high temperature plasma operation will be presented in this paper. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the Modeling of Wall Heat Flux Partitioning in Subcooled Flow Boiling

Accurate prediction of void distribution in reactor coolant channels at subcooled boiling conditions is an important factor in the analysis of the operating conditions of both pressurized water reactors (PWRs) and boiling water reactors (BWRs). Its importance arises from purely thermal-hydraulic considerations (thermal limits, CRUD formation, etc.) and the impact of void reactivity feedback on core neutronics. A mechanistic multidimensional model of subcooled boiling was originally developed by Kurul and Podowski. Whereas this model has been implemented in several commercial CFD codes and successfully used in computer simulations of flow and phase distributions in the coolant channels of light water reactor, additional new modeling aspects of forced-convection subcooled boiling heat transfer have been investigated in recent studies. The purpose of this paper is to formulate a modified model of wall heat flux partitioning, which allows for capturing and quantifying the effect of simultaneous evaporation and condensation at the heated wall on the net evaporation rate and wall temperature. The new model has been implemented in the NPHASE-CMFD code, numerically tested and validated against experimental data. A mechanistic wall heat flux partitioning model for subcooled flow boiling has been presented. This model has been combined with extensively tested models of interfacial mass, momentum and energy transfer terms. It turns out that the model predictions of the wall temperature and void fraction are in good agreement with the experimental data of reference. Future work will focus on the continuation of model validation against experimental data, and on extending its scope to include the phenomena governing departure from nucleate boiling. (authors)

42 ENGINEERING↗

MODELS FOR ESTIMATING THE AUTOFRETTAGE PRESSURE AND RESIDUAL STRESSES IN WALLS OF TYPE 2 PRESSURE VESSELS

Autofrettage is a manufacturing process used during fabrication of Type 2 pressure vessels designed for usage at high pressures to enhance the fatigue life. The process locks high compressive residual stresses in the vessel’s liner wall that reduce the maximum and the mean stress during service loading. To achieve a consistent residual stress profile across the wall of the vessel, the choice of autofrettage pressure is critical. Several finite element analyses runs were conducted to estimate the correct autofrettage pressure that is a function of the yield strength of the liner material, the wall thickness, and the outside diameter of the liner for a wrap thickness of 17.06 mm (48 wire layers). From the finite element analyses results, models were developed to estimate the correct autofrettage pressure and the residual stress distribution across the liner wall as a function of the yield strength of the liner material, the wall thickness, and the outside diameter of the liner.

08 HYDROGEN↗

X-ray imaging of extended magnetic domain walls in Ni80Fe20 wires

We have used magnetic transmission X-ray microscopy to image magnetization configurations in 700 nm wide Ni{sub 80}Fe{sub 20} planar wires attached to 'nucleation' pads Domain walls were observed to inject only across half of the wire width but extend to several micrometers in length. Magnetostatic interactions with adjacent wires caused further unusual domain wall behavior. Micromagnetic modeling suggests the extended walls have Neel-like structure along their length and indicates weaker exchange coupling than is often assumed. These observations explain previous measurements of domain wall injection and demonstrate that magnetic domain walls in larger nanowires cannot always be considered as localized entities.

36 MATERIALS SCIENCE↗

Moebius Algorithm for Domain Wall and GapDW Fermions

The M\"obius domain wall action \cite{Brower:2004xi} is a generalization of Shamir's action, which gives exactly the same overlap fermion lattice action as the separation ($L_s$) between the domain walls is taken to infinity. The performance advantages of the algorithm are presented for a small ensemble of quenched, full QCD domain wall and Gap domain wall lattices \cite{Vranas:2006zk}. In particular, it is shown that at the larger lattice spacings relevant to current dynamical simulations M\"obius fermions work well together with GapDWF reducing $L_s$ by more than a factor of two. It is noted that there is precise map between the domain wall and effective overlap action at finite quark mass including finite $L_s$ chiral violations so that the Ward-Takahashi identities for the axial and vector currents are exactly equivalent in both formulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pinning induced by inter-domain wall interactions in planar magnetic nanowires

We have investigated pinning potentials created by inter-domain wall magnetostatic interactions in planar magnetic nanowires. We show that these potentials can take the form of an energy barrier or an energy well depending on the walls' relative monopole moments, and that the applied magnetic fields required to overcome these potentials are significant. Both transverse and vortex wall pairs are investigated and it is found that transverse walls interact more strongly due to dipolar coupling between their magnetization structures. Simple analytical models which allow the effects of inter-domain wall interactions to be estimated are also presented.

36 MATERIALS SCIENCE↗

A Colebrook equation for impinging radial wall jets

Here, in this study, we evaluate the skin coefficient of friction for steady turbulent radial wall jets across smooth and rough surfaces. Although the Colebrook equation has been used successfully for many decades to evaluate friction factors for flows through smooth and rough pipes, how roughness affects the skin friction coefficient for steady turbulent radial wall jets remains unclear. Here we explore a Colebrook-type equation for skin friction coefficients associated with single-phase turbulent radial wall jets arising from orthogonally impinging circular jets. The fully iterative solution, based on well-established concepts of turbulent wall-bounded flow, is presented along with a power-law approximation and a non-iterative approximation for the friction coefficient derived therefrom. We find the skin coefficient of friction defined on the peak radial velocity to be a function of position over rough but not smooth surfaces in contrast to pipe friction factors that remain independent of axial position. These results follow expected trends, explain prior heterogeneity in power-law expressions for the skin friction coefficient and have significant implications for the industrial use of jets in mixing vessels.

friction losses↗

On the tokamak first wall response to the edge localized mode bursts

The effects of wall outgassing on the H-mode pedestal recovery after edge localized mode (ELM) crash is examined with a simplified model of hydrogen adsorption/desorption processes. The parameters governing the dynamics of the wall response to the ELM crash are found. It is shown that within adopted hydrogen adsorption/desorption model a significant impact of the wall outgassing on the pedestal recovery can be observed for the wall surface temperature range between 500 K and 800 K.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A LIBS method for simultaneous monitoring of the impurities and the hydrogenic composition present in the wall of the TJ-II stellarator

The study of plasma-wall interactions and impurity transport in the plasma fusion devices is critical for the development of future fusion reactors. An experiment to perform laser induced breakdown spectroscopy, using minor modifications of our existing laser blow-off impurity injection system, has been set up thus making both experiments compatible. The radiation produced by the laser pulse focused at the TJ-II wall evaporates a surface layer of deposited impurities and the subsequent radiation produced by the laser-produced plasma is collected by two separate lens and fiber combinations into two spectrometers. The first spectrometer, with low spectral resolution, records a spectrum from 200 to 900 nm to give a survey of impurities present in the wall. The second one, with high resolution, is tuned to the wavelengths of the Hα and Dα lines in order to resolve them and quantify the hydrogen isotopic ratio present on the surface of the wall. The alignment, calibration, and spectral analysis method will be described in detail. First experimental results obtained with this setup will be shown and its relevance for the TJ-II experimental program discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plant cell wall characterization using scanning probe microscopy techniques

Lignocellulosic biomass is today considered a promising renewable resource for bioenergy production. A combined chemical and biological process is currently under consideration for the conversion of polysaccharides from plant cell wall materials, mainly cellulose and hemicelluloses, to simple sugars that can be fermented to biofuels. Native plant cellulose forms nanometer-scale microfibrils that are embedded in a polymeric network of hemicelluloses, pectins, and lignins; this explains, in part, the recalcitrance of biomass to deconstruction. The chemical and structural characteristics of these plant cell wall constituents remain largely unknown today. Scanning probe microscopy techniques, particularly atomic force microscopy and its application in characterizing plant cell wall structure, are reviewed here. We also further discuss future developments based on scanning probe microscopy techniques that combine linear and nonlinear optical techniques to characterize plant cell wall nanometer-scale structures, specifically apertureless near-field scanning optical microscopy and coherent anti-Stokes Raman scattering microscopy.

09 BIOMASS FUELS↗

Stud Walls With Continuous Exterior Insulation for Factory Built Housing: New York, New York (Fact Sheet), NREL (National Renewable Energy Laboratory)

The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective alternative envelope designs. In the near term, these technologies will play a central role in meeting stringent energy code requirements. For manufactured homes, the thermal requirements, last updated by statute in 1994, will move up to the more rigorous IECC 2012 levels in 2013, the requirements of which are consistent with site built and modular housing. This places added urgency on identifying envelope technologies that the industry can implement in the short timeframe. The primary goal of this research is to develop wall designs that meet the thermal requirements based on 2012 IECC standards. Given the affordable nature of manufactured homes, impact on first cost is a major consideration in developing the new envelope technologies. This work is part of a four-phase, multi-year effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three selected methods for building high performance wall systems. Phase 2 focused on the development of viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped critique and select the most viable solution to move further in the research - stud walls with continuous exterior insulation. Phase 3, the subject of the current report, focused on the design development of the selected wall concept and explored variations on the use of exterior foam insulation. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗