Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Dewar Testing of Coaxial Resonators at MSU

Michigan State University is currently testing prototype and production cavities for two accelerator projects. 80.5 MHz {beta} = 0.085 quarter wave resonators (QWR) are being produced as part of a cryomodule for ReA3. 322 MHz {beta} = 0.53 half wave resonators (HWR) are being prototyped for a driver linac for the Facility for Rare Isotope Beams. This paper will discuss test results and how different cavity preparations effect cavity performs. Also various diagnostics methods have been developed, such as second sound quench location determination, and temperature mapping to determine hot spots from defects and multipacting location.

43 PARTICLE ACCELERATORS↗

Sustained Availability of Technetium-99m - Possible Paths Forward

The availability of technetium-99m (99mTc) for single-photon imaging in diagnostic nuclear medicine is crucial, and current availability is based on the molybdenum-99 (99Mo)/99mTc generator fabricated from fission-based molybdenum (F 99Mo) produced by use of highly enriched uranium (HEU) targets. The use of HEU targets is being phased out because of risks related to nuclear material proliferation, so alternative strategies for production of both 99Mo and 99mTc are being evaluated intensely. There are evidently no plans for replacement of the limited number of reactors that have primarily provided most of the 99Mo. The uninterrupted, dependable availability of 99mTc is a crucial issue. For these reasons, new options being pursued include both reactor- and accelerator-based strategies to sustain the continued availability of 99mTc without the use of HEU. In this paper the scientific and economic issues for transitioning from HEU to non-HEU are also discussed. In addition, the comparative advantages, disadvantages, technical challenges, present status, future prospects, security concerns, economic viability, and regulatory obstacles are reviewed. In addition, the international actions in progress towards evolving possible alternative strategies to produce 99Mo and/or 99mTc are analyzed. The breadth of technologies and new strategies under development to provide 99Mo and 99mTc reflects both the broad interest in and the importance of the pivotal role of 99mTc in diagnostic nuclear medicine.

accelerator production↗

TU-G-213-00: The International Electrotechnical Commission (IEC): What Is It and Why Should Medical Physicists Care?

The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

60 APPLIED LIFE SCIENCES↗

Experimental verification of tomographic phase-space imaging for beams with space-charge using a pinhole-scan

A model is described for tomographic phase-space mapping and emittance measurement in beams with space-charge. The tomographic results of an experiment with a 10 keV space-charge dominated electron beam are presented. The data are compared against a direct experimental sampling of the phase-space using a pinhole scan. It is found that the accuracy of the tomographic method is within 10% for beams with space-charge intensity less than 90%. With the aid of numerical simulation the observed similarities and differences between the tomography method and pinhole scan are discussed.

43 PARTICLE ACCELERATORS↗

Ion velocity and plasma potential measurements of a cylindrical cusped field thruster

Measurements of the most probable time-averaged axial ion velocities and plasma potential within the acceleration channel and in the plume of a straight-channeled cylindrical cusped field thruster operating on xenon are presented. Ion velocities for the thruster are derived from laser-induced fluorescence measurements of the 5d[4]{sub 7/2}-6p[3]{sub 5/2} xenon ion excited state transition centered at {lambda}=834.72nm. Plasma potential measurements are made using a floating emissive probe with a thoriated-tungsten filament. The thruster is operated in a power matched condition with 300 V applied anode potential for comparison to previous krypton plasma potential measurements, and a low power condition with 150 V applied anode potential. Correlations are seen between the plasma potential drop outside of the thruster and kinetic energy contours of the accelerating ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A soft x-ray transmission grating imaging-spectrometer for the National Ignition Facility

A soft x-ray transmission grating spectrometer has been designed for use on high energy-density physics experiments at the National Ignition Facility (NIF); coupled to one of the NIF gated x-ray detectors it records 16 time-gated spectra between 250 and 1000 eV with 100 ps temporal resolution. The trade-off between spectral and spatial resolution leads to an optimized design for measurement of emission around the peak of a 100-300 eV blackbody spectrum. Performance qualification results from the NIF, the Trident Laser Facility and vacuum ultraviolet beamline at the National Synchrotron Light Source, evidence a <100 {mu}m spatial resolution in combination with a source-size limited spectral resolution that is <10 eV at photon energies of 300 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emittance of positron beams produced in intense laser plasma interaction

The first measurement of the emittance of intense laser-produced positron beams has been made. The emittance values were derived through measurements of positron beam divergence and source size for different peak positron energies under various laser conditions. For one of these laser conditions, we used a one dimensional pepper-pot technique to refine the emittance value. The laser-produced positrons have a geometric emittance between 100 and 500 mm{center_dot}mrad, comparable to the positron sources used at existing accelerators. With 10{sup 10}-10{sup 12} positrons per bunch, this low emittance beam, which is quasi-monoenergetic in the energy range of 5-20 MeV, may be useful as an alternative positron source for future accelerators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High contrast ion acceleration at intensities exceeding 10{sup 21} Wcm{sup −2}

Ion acceleration from short pulse laser interactions at intensities of 2×10{sup 21}Wcm{sup −2} was studied experimentally under a wide variety of parameters, including laser contrast, incidence angle, and target thickness. Trends in maximum proton energy were observed, as well as evidence of improvement in the acceleration gradients by using dual plasma mirrors over traditional pulse cleaning techniques. Extremely high efficiency acceleration gradients were produced, accelerating both the contaminant layer and high charge state ions from the bulk of the target. Two dimensional particle-in-cell simulations enabled the study of the influence of scale length on submicron targets, where hydrodynamic expansion affects the rear surface as well as the front. Experimental evidence of larger electric fields for sharp density plasmas is observed in simulation results as well for such targets, where target ions are accelerated without the need for contaminant removal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond laser plasma plume characteristics in the nanojoule ablation regime

Laser ablation of chromium with nanojoule energy UV femtosecond pulses under background pressure conditions between 0.3 Torr and 700 Torr is studied and the corresponding plasma plume images at different times after irradiation are measured. The ablation focal spot is less than or the order of a micron when 170 nJ of laser pulse energy is used. This low pulse energy leads to short lifetimes of the plasma of the order of tens of nanoseconds. The plume shape changes with ambient pressure due to the collision with background gas. An axially stretched plume changes to a more circular plume as the pressure increases. In addition, a separation of the ionic and atomic components is observed at lower pressure. These two components move at significantly different velocities as well. The plasma plume expands at almost constant velocity at very low pressure but exhibits significant deceleration at higher pressure reaching an asymptotic stopping distance. Plume images are also obtained near the ablation threshold pulse energy. The plume characteristics are compared to different models of plume expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma emission spectroscopy for operating and developing the Spallation Neutron Source (SNS) H{sup −} ion sources

A RF-driven, Cs-enhanced H{sup −} ion source feeds the SNS accelerator with a high current (typically >50 mA), ∼1.0 ms pulsed beam at 60 Hz. To achieve the persistent high current beam for several weeks long service cycles, each newly installed ion source undergoes a rigorous conditioning and cesiation processes. Plasma conditioning outgases the system and sputter-cleans the ion conversion surfaces. A cesiation process immediately following the plasma conditioning releases Cs to provide coverage on the ion conversion surfaces. The effectiveness of the ion source conditioning and cesiation is monitored with plasma emission spectroscopy using a high-sensitivity optical spectrometer. Plasma emission spectroscopy is also used to provide a means for diagnosing and confirming a failure of the insulating coating of the ion source RF antenna which is immersed in the plasma. Emissions of composition elements of the antenna coating material, Na emission being the most significant, drastically elevate to signal a failure when it happens. Plasma spectra of the developmental ion source with an AlN (aluminum nitrite) chamber and an external RF antenna are also briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High speed measurements of neutral beam turn-on and impact of beam modulation on measurements of ion density

Modulation of neutral beams on tokamaks is performed routinely, enabling background rejection for active spectroscopic diagnostics, and control of injected power and torque. We find that there exists an anomalous initial transient in the beam neutrals delivered to the tokamak that is not accounted for by the accelerator voltage and power supply current. Measurements of the charge-exchange and beam photoemission on the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] at high speed (200 μs) reveal that the energy of the beam neutrals is constant, but the density of beam neutrals displays dramatic variation in the first 2–3 ms following beam turn-on. The impact of this beam density variation on inferred ion densities and impurity transport is presented, with suggested means to correct for the anomalous transient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Faraday cup fast ion loss detector for keV beam ions

The development and testing of a Faraday cup fast-ion loss detector capable of measuring sub 100 keV particles is documented. Such measurement capabilities play an important role in the assessment of particle confinement of nuclear fusion experiments. The detector is manufactured using thin-film deposition techniques, building upon previous work using discrete foils. This new manufacturing method allows the form factor of the sensor to become that of essentially a microchip. Analysis of the diagnostic response is performed using Monte-Carlo particle simulations. These simulations show peaks in the detector response at 40 and 70 keV. The sensor is then tested in a tunable linear accelerator capable of accelerating protons from 20 to 120 keV. Finally, the detector response was found to be well matched to simulations. Improvements to the design to facilitate robustness are discussed.

47 OTHER INSTRUMENTATION↗

Fast switching magnet for heavy ion beam separation

This paper presents the design for a switching magnet capable of deflecting 6.5 MeV/u heavy-ion beams with mass-to-charge ratio of 7 by 10 degrees. This magnet can produce variable flat-top pulses from 1 to 30 ms with rise and fall times of less than 0.5 ms at a variable duty cycle of 3–91% into a heavily inductive load. The magnet has a laminated, iron dominated, H-shaped core. Directly-cooled copper pancake coils energize the magnet. We present the magnet design considerations, including the results of extensive computer modeling. Finally, we also present the conceptual engineering design and the studies of magnet yoke fabrication.

47 OTHER INSTRUMENTATION↗

Trident Web page

An Extensive Diagnostic Suite Enables Cutting-edge Research at Trident The Trident Laser Facility at Los Alamos National Laboratory is an extremely versatile Nd:glass laser system dedicated to high energy density physics research and fundamental laser-matter interactions. Trident's Unique Laser Capabilities Provide an Ideal Platform for Many Experiments. The laser system consists of three high energy beams which can be delivered into two independent target experimental areas. The target areas are equipped with an extensive suite of diagnostics for research in ultra-intense laser matter interactions, dynamic material properties, and laser-plasma instabilities. Several important discoveries and first observations have been made at Trident including laser-accelerated MeV mono-energetic ions, nonlinear kinetic plasma waves, transition between kinetic and fluid nonlinear behavior, as well as other fundamental laser-matter interaction processes. Trident's unique long-pulse capabilities have enabled state-of-the-art innovations in laser-launched flyer-plates, and other unique loading techniques for material dynamics research.

36 MATERIALS SCIENCE↗

Simulations of the new DARHT Axis-II bucking coil magnetic field and effects

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. The Dual-Axis Radiography for Hydrodynamic Testing (DARHT) facility at Los Alamos was developed for flash radiography of large hydrodynamic experiments. Two linear induction accelerators (LIAs) produce the bremsstrahlung radiographic source spots for orthogonal views of each experiment (“hydrotest”). The 2-kA, 20-MeV Axis-I LIA creates a single 60-ns radiography pulse. For time resolution of the hydrotest dynamics, the 1.7-kA, 16.5-MeV Axis-II LIA creates up to four radiography pulses by slicing them out of a longer pulse that has a 1.6-µs flattop. Both axes now routinely produce radiographic source spot sizes having full-width at half-maximum (FWHM) less than 1 mm.

43 PARTICLE ACCELERATORS↗

Wind-tunnel investigation of the low-speed aerodynamics of slender accelerator-type configurations

The NASA-Langley 14x22-ft subsonic wind tunnel has been used to ascertain the low speed aerodynamics of a conical-forebody/annular conformal propulsion system/truncated conical afterbody hypersonic-accelerator configuration with delta-planform wing. Six-component force-and-moment data were obtained over the -4 to +30 deg alpha range and + or - 20 deg sideslip. Flow visualization diagnostics were used to characterize configuration aerodynamics. Vortex flows from the conical forebody created large values of local inflow angles at the engine inlet locations on the lee side of the model, at the moderate-alpha values associated with takeoff and landing.

Gatlin, Gregory M.↗

Langmuir Probe Measurements Within the Discharge Channel of the 20-kW NASA-300M and NASA-300MS Hall Thrusters

NASA is presently developing a high-power, high-efficiency, long-lifetime Hall thruster for the Solar Electric Propulsion Technology Demonstration Mission. In support of this task, studies have been performed on the 20-kW NASA-300M Hall thruster to aid in the overall design process. The ability to incorporate magnetic shielding into a high-power Hall thruster was also investigated with the NASA- 300MS, a modified version of the NASA-300M. The inclusion of magnetic shielding would allow the thruster to push existing state-of-the-art technology in regards to service lifetime, one of the goals of the Technology Demonstration Mission. Langmuir probe measurements were taken within the discharge channels of both thrusters in order to characterize differences at higher power levels, as well as validate ongoing modeling efforts using the axisymmetric code Hall2De. Flush-mounted Langmuir probes were also used within the channel of the NASA-300MS to verify that magnetic shielding was successfully applied. Measurements taken from 300 V, 10 kW to 600 V, 20 kW have shown plasma potentials near anode potential and electron temperatures of 4 to 12 eV at the walls near the thruster exit plane of the NASA-300MS, verifying magnetic shielding and validating the design process at this power level. Channel centerline measurements on the NASA-300M from 300 V, 10 kW to 500 V, 20 kW show the electron temperature peak at approximately 0.1 to 0.2 channel lengths upstream of the exit plane, with magnitudes increasing with discharge voltage. The acceleration profiles appear to be centered about the exit plane with a width of approximately 0.3 to 0.4 channel lengths. Channel centerline measurements on the NASA-300MS were found to be more challenging due to additional probe heating. Ionization and acceleration zones appeared to move downstream on the NASA-300MS compared to the NASA-300M, as expected based on the shift in peak radial magnetic field. Additional measurements or alternative diagnostics will be needed to verify peak electron temperatures in the NASA-300MS and compare them with model predictions.

Hall thruster↗

Fast Camera Imaging of Hall Thruster Ignition

Hall thrusters provide efficient space propulsion by electrostatic acceleration of ions. Rotating electron clouds in the thruster overcome the space charge limitations of other methods. Images of the thruster startup, taken with a fast camera, reveal a bright ionization period which settles into steady state operation over 50 μs. The cathode introduces azimuthal asymmetry, which persists for about 30 μs into the ignition. Plasma thrusters are used on satellites for repositioning, orbit correction and drag compensation. The advantage of plasma thrusters over conventional chemical thrusters is that the exhaust energies are not limited by chemical energy to about an electron volt. For xenon Hall thrusters, the ion exhaust velocity can be 15-20 km/s, compared to 5 km/s for a typical chemical thruster

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗