Search NASA⌕ Search

SEARCH · Search NASA

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Activity measurement of Fe 60 through the decay of Co 60 m and confirmation of its half-life

The half-life of the neutron-rich nuclide, 60Fe has been in dispute in recent years. A measurement in 2009 published a value of (2.62 ± 0.04) × 106 years, almost twice that of the previously accepted value from 1984 of (1.49 ± 0.27) × 106 years. This longer half-life was confirmed in 2015 by a second measurement, resulting in a value of (2.50 ± 0.12) × 106 years. All three half-life measurements used the grow-in of the γ-ray lines in 60Ni from the decay of the ground state of 60Co (t1/2=5.27 years) to determine the activity of a sample with a known number of 60Fe atoms. In contrast, the work presented here measured the 60Fe activity directly via the 58.6 keV γ-ray line from the short-lived isomeric state of 60Co (t1/2=10.5 minutes), thus being independent of any possible contamination from long-lived 60gCo. A fraction of the material from the 2015 experiment with a known number of 60Fe atoms was used for the activity measurement, resulting in a half-life value of (2.72 ± 0.16) × 106 years, confirming again the longer half-life. In addition, 60Fe/56Fe isotopic ratios of samples with two different dilutions of this material were measured with Accelerator Mass Spectrometry (AMS) to determine the number of 60Fe atoms. Combining this with our activity measurement resulted in a half-life value of (2.69 ± 0.28) × 106 years, again agreeing with the longer half-life.

Ostdiek, Karen M.↗

A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity

Purpose: Total body irradiation (TBI) with megavoltage photon beams has been accepted as an important component of management for a number of hematologic malignancies, generally as part of bone marrow conditioning regimens. The purpose of this paper is to present and discuss the authors' TBI technique, which both simplifies the treatment process and improves the treatment quality. Methods: An AP/PA TBI treatment technique to produce uniform dose distributions using sequential collimator reductions during each fraction was implemented, and a sample calculation worksheet is presented. Using this methodology, the dosimetric characteristics of both 6 and 18 MV photon beams, including lung dose under cerrobend blocks was investigated. A method of estimating midplane lung doses based on measured entrance and exit doses was proposed, and the estimated results were compared with measurements. Results: Whole body midplane dose uniformity of {+-}10% was achieved with no more than two collimator-based beam modulations. The proposed model predicted midplane lung doses 5% to 10% higher than the measured doses for 6 and 18 MV beams. The estimated total midplane doses were within {+-}5% of the prescribed midplane dose on average except for the lungs where the doses were 6% to 10% lower than the prescribed dose on average. Conclusions: The proposed TBI technique can achieve dose uniformity within {+-}10%. This technique is easy to implement and does not require complicated dosimetry and/or compensators.

61 RADIATION PROTECTION AND DOSIMETRY↗

Draft report on melt point as a function of composition for urania-based systems

This report documents the testing of a urania (UO 2.00 ) sample as a baseline and the attempt to determine the melt point associated with 4 compositions of urania-ceria and urania-neodymia pseudo binaries provided by ORNL, with compositions of 95/5, and 80/20 and of (U/Ce)O 2.00 and (U/Nd)O 2.00 in the newly developed ceramic melt point determination system. A redesign of the system using parts fabricated from tungsten was undertaken in order to help prevent contamination and tungsten carbide formation in the crucibles. The previously developed system employed mostly graphite parts that were shown to react with the sample containment black-body crucible leading to unstable temperature readings and crucible failure, thus the redesign. Measured melt point values of UO 2.00 and U 0.95 Ce 0.05 O 2.00 , U 0.80 Ce 0.20 O 2.00 , U 0.95 Nd 0.05 O 2.00 and U 0.80 Nd 0.20 O 2.00 were measured using a 2-color pyrometer. The value measured for UO 2.00 was consistent with the published accepted value 2845°C±25°C, although a wide range of values has been published by researchers and will be discussed later in the text. For comparison, values obtained from a published binary phase diagram of UO 2 -Nd 2 O 3 were used for comparison with our measure values. No literature melt point values for comparison with the measurements performed in this study were found for (U/Ce)O 2.00 in our stoichiometry range.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial Radiation of Nuclear Power Plant Components (CRADA NFE-17-06892 Final Report)

As advanced reactor concepts are developed, instrumentation and control (I&C) cables and sensors will play a significant role in assuring their operation is well understood, and safety-related process information can be collected reliably over the course of their design life. As a first step to develop acceptance criteria and define the limits of currently available nuclear I&C cable and sensor technology, a collaboration between Oak Ridge National Laboratory and Analysis and Measurement Services (AMS) Corporation was initiated under the Gateway for Accelerated Innovation in Nuclear (GAIN) Program. This collaborative effort focused on providing technical information related to the combined thermal and radiation aging of nuclear power plant (NPP) cables, companion NPP cable insulation samples, and two prototype temperature and two pressure sensors. This work was carried out using the instrumented gamma irradiation system that is part of the High Flux Isotope Reactor Gamma Irradiation Facility (HFIR GIF). This system provided the opportunity for the condition of the prototype sensors to be tracked during the irradiation in order to determine their functional limits with greater granularity when compared to a simple irradiation insertion at the HFIRGIF. Experimental assemblies for sensor irradiation were successfully completed, and sensor irradiation to accumulated dose of 3000 kGy at a rate of approximately 6 kGy/hr was carried out. Two prototype temperature assemblies were continuously monitored during exposure to 3000 kGy and found to have no observable degradation from the irradiation. Two pressure sensors were first irradiated to 1000 kGy. At which point, one of the sensors was found to operate normally; however, a second sensor failed the operability test. The operable pressure sensor output was then continuously monitored from 1000 kGy to 3000 kGy. The sensor output exhibited steady trendable drift versus the accumulated radiation dose. At the conclusion of the irradiation, the four test sensors were released for laboratory calibration checks. The calibration check of the temperature sensors found no significant change after irradiation compared to baseline measurements before irradiation; however, both pressure sensors failed the post-test calibration checks and both sensors were not functioning properly. These results will help inform sensor manufacturers and I&C design engineers of potential limitations of these types of sensors for use in high radiation environments associated with the compact configuration of new Small Modular Reactors (SMRs) such as NuScale’s reactor power module. Irradiations on NPP cables and companion samples were not completed due to programmatic delays, however a path forward that was based on lessons learned from this project was defined to accommodate future, comparable instrumented gamma irradiations at the HFIR GIF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Self-consistent Color–Stellar Mass-to-light Ratio Relations for Low Surface Brightness Galaxies

The color–stellar mass-to-light ratio relation (CMLR) is a widely accepted tool for estimating the stellar mass (M {sub *}) of a galaxy. However, an individual CMLR tends to give distinct M {sub *} for a same galaxy when it is applied in different bands. Examining five representative CMLRs from the literature, we find that the difference in M {sub *} predicted in different bands from optical to near-infrared by a CMLR is 0.1 ∼ 0.3 dex. Based on a sample of low surface brightness galaxies that covers a wide range of color and luminosity, we therefore recalibrated each original CMLR in r, i, z, J, H, and K bands to give internally self-consistent M {sub *} for a same galaxy. The g–r is the primary color indicator in the recalibrated relations, which show little dependence on red (r–z) or near-infrared (J–K) colors. Additionally, the external discrepancies in the originally predicted γ {sub *} by the five independent CMLRs have been greatly reduced after recalibration, especially in the near-infrared bands, implying that the near-infrared luminosities are more robust in predicting γ {sub *}. For each CMLR, the recalibrated relations provided in this work could produce internally self-consistent M {sub *} from divergent photometric bands, and are extensions of the recalibrations from the Johnson–Cousin filter system by the pioneering work of McGaugh & Schombert to the filter system of the Sloan Digital Sky Survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Polycyclic Aromatic Hydrocarbon Emission in Spitzer /IRS Maps. II. A Direct Link between Band Profiles and the Radiation Field Strength

We decompose the observed 7.7 μ m polycyclic aromatic hydrocarbon (PAH) emission complexes in a large sample of over 7000 mid-infrared spectra of the interstellar medium using spectral cubes observed with the Spitzer /IRS-SL instrument. In order to fit the 7.7 μ m PAH emission complex we invoke four Gaussian components, which are found to be very stable in terms of their peak positions and widths across all of our spectra, and subsequently define a decomposition with fixed parameters, which gives an acceptable fit for all the spectra. We see a strong environmental dependence on the interrelationships between our band fluxes—in the H ii regions all four components are intercorrelated, while in the reflection nebulae (RNs) the inner and outer pairs of bands correlate in the same manner as previously seen for NGC 2023. We show that this effect arises because the maps of RNs are dominated by emission from strongly irradiated photodissociation regions, while the much larger maps of H ii regions are dominated by emission from regions much more distant from the exciting stars, leading to subtly different spectral behavior. Further investigation of this dichotomy reveals that the ratio of two of these components (centered at 7.6 and 7.8 μ m) is linearly related to the UV-field intensity (log G {sub 0}). We find that this relationship does not hold for sources consisting of circumstellar material, which are known to have variable 7.7 μ m spectral profiles.

79 ASTRONOMY AND ASTROPHYSICS↗

Mineralogical diversity (spectral reflectance and Moessbauer data) in compositionally similar impact melt rocks from Manicouagan Crater, Canada

Meteoritic impacts under oxidizing surface conditions occur on both earth and Mars. Oxidative alteration of impact melt sheets is reported at several terrestrial impact structures including Manicouagan, West Clearwater Lake, and the Ries Basin. A number of studies have advocated that a significant fraction of Martian soil may consist of erosional products of oxidatively altered impact melt sheets. If so, the signature of the Fe-bearing mineralogies formed by the process may be present in visible and near infrared reflectivity data for the Martian surface. Of concern is what mineral assemblages form in impact melt sheets produced under oxidizing conditions and what their spectral signatures are. Spectral and Moessbauer data for 19 powder samples of impact melt rock from Manicouagan Crater are reported. Results show for naturally occurring materials that composite hematite-pyroxene bands have minima in the 910-nm region. Thus many of the anomalous Phobos-2 spectra, characterized by a shallow band minimum in the near-IR whose position varies between approximately 850 and 1000 nm, can be explained by assemblages whose endmembers (hematite and pyroxene) are accepted to be present on Mars. Furthermore, results show that a mineralogically diverse suite of rocks can be generated at essentially constant composition, which implies that variations in Martian surface mineralogy do not necessarily imply variations in chemical composition.

Morris, R. V.↗

Evaluation of a Variable Facesheet Liner Configuration in Grazing Incidence for Broadband Noise Reduction

Abstract Tests were conducted in the NASA Langley Grazing Flow Impedance Tube (GFIT) to determine the broadband noise reduction capability of a variable facesheet liner. Three uniform liners were designed to achieve sound absorption over distinct frequency regimes at Mach 0.0. Each liner was fabricated and tested in the GFIT at sound pressure levels of 120 and 140 dB, and at tangential flow velocities up to Mach 0.5. A variable facesheet liner was fabricated to combine the geometries of these three liners, such that the facesheet geometry (hole diameter and porosity) was varied across the liner surface. The Prony method was used to educe the impedance of each sample, and these impedances were input to the CHE (Convected Helmholtz Equation) propagation code to predict the acoustic pressure profiles in the GFIT. Comparisons of predicted and measured acoustic pressure profiles were used to confirm the uniformity of all four liners, and to demonstrate the suitability of the CHE code in analysis of the variable facesheet concept. Results showed good comparison at no flow and Mach 0.3, and acceptable comparison at Mach 0.5. The variable facesheet liner provides enhanced broadband noise reduction at the no-flow condition for which it was designed, but further optimization is needed to target flow conditions.

acoustic↗

Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.

60 APPLIED LIFE SCIENCES↗

Air compressor load forecasting using artificial neural network

Air compressor systems are responsible for approximately 10% of the electricity consumed in United States and European Union industry. As many researches have proven the effectiveness of using Artificial Neural Network inair compressor performance prediction, there is still a need to forecast the air compressor electrical load profile. The objective of this study is to predict compressed air systems’ electrical load profile, which is valuable to industry practitioners as well as software providers in developing better practice and tools for load managementand look-ahead scheduling programs. Two artificial neural networks, Two-Layer Feed-Forward Neural Networkand Long Short-Term Memory were used to predict an air compressors electrical load. Compressors with three different control mechanisms are evaluated with a total number of 11,874 observations. Here, the forecasts were validated using out-of-sample datasets with 5-fold cross-validation. Models produced average coefficient ofdetermination values from 0.24 to 0.94, average root-mean-square errors from 0.05 kW - 5.83 kW, and meanabsolute scaled errors from 0.20 to 1.33. The results indicate that both artificial neural networks yield goodresults for compressors using variable speed drive (average R 2 = 0.8 and no naïve forecasting), only the longshort-term memory model gives acceptable results for compressors using on/off control (average R 2 = 0.82 and no naïve forecasting), and no satisfactory results are obtained for load/unload type air compressors (models constituting active forecasting).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Search for Supersymmetry in Events with Large Missing Transverse Momentum, Jets, and at Least One Tau Lepton in 7 TeV Proton-Proton Collision Data with the ATLAS Detector

CERN-LHC. Study of events from proton-proton interactions at a centre-of-mass energy of 7 Tev which have final states comprising large missing transverse momentum, jets and at least one hadronically decaying TAU letpton accompanied by zero or one additional light lepton (ELECTRON or MUON). The data sample, collected during 2011, has an integrated luminosity of 4.7 fb-1. In the framework of gauge-mediated SUSY-breaking (GMSB) models, lower limits on the mass scale LAMBDA are determined. Data are presented for four channels comprising single and double TAU production with no extra light leptons and single TAU production with an ELECTRON and with a MUON. The exclusion data are from the combined channels. Acceptances and efficiencies for each channel are tabulated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dimming the Lights: 2D Simulations of Deflagrations of Hybrid C/O/Ne White Dwarfs Using FLASH

The dimmest and most numerous outlier of the Type Ia supernova population, the Type Iax event, is increasingly being found in the results of observational campaigns. There is currently no single accepted model to describe these events. This 2D study explores the viability of modeling Type Iax events as a hybrid C/O/Ne white dwarf progenitor undergoing a deflagration using the multiphysics software FLASH. This hybrid was created using the stellar evolution code MESA, and its C-depleted core and mixed structure have demonstrated lower yields than traditional C/O progenitors in previous deflagration-to-detonation studies. To generate a sample, 30 “realizations” of this simulation were performed, the only difference being the shape of the initial match head used to start the deflagration. Consistent with earlier work, these realizations produce the familiar hot dense bound remnant surrounded by sparse ejecta. Our results indicate that the majority of the star remains unburned (∼70%) and bound (>90%). Our realizations produce total ejecta yields on the order of 10 −2 –10 −1 M ☉ , ejected 56 Ni yields on the order of 10 −4 –10 −2 M ☉ , and ejecta kinetic energies on the order of 10 48 –10 49 erg. Compared to yields inferred from recent observations of the dimmest Type Iax events—SN 2007qd, SN 2008ha, SN 2010ae, SN 2019gsc, SN 2019muj, SN 2020kyg, and SN 2021fcg—our simulation produces comparable 56 Ni yields but too-small total yields and kinetic energies. Reignition of the remnant is also seen in some realizations.

Hydrodynamical simulations↗

Effect of external disturbances and data rate on the response of an automatic landing system capable of curved trajectories

The effects of steady wind, turbulence, data sample rate, and control-actuator natural frequency on the response of a possible automatic landing system were investigated in a nonstatistical study. The results indicate that the system, which interfaces with the microwave landing system, functions well in winds and turbulence as long as the guidance law contains proper compensation for wind. The system response was satisfactory down to five data samples per second, which makes the system compatible with the microwave landing system. No adverse effects were observed when actuator natural frequency was lowered. For limiting cases, those cases where the roll angle goes to zero just as the airplane touches down, the basic method for computing the turn-algorithm gains proved unsatisfactory and unacceptable landings resulted. Revised computation methods gave turn-algorithm gains that resulted in acceptable landings. The gains provided by the new method also improved the touchdown conditions for acceptable landings over those obtained when the gains were determined by the old method.

Sherman, W. L.↗

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical Laboratory (AL) at the Materials and Fuels Complex (MFC) at Idaho National Laboratory (INL) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RH-TRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization if RH-TRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all AK [define AK] documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization Techniques for TRU Waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory - 19610

Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical laboratory (AL) at the INL Materials and Fuels Complex (MFC) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste as Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RHTRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization of RHTRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all Acceptable Knowledge (AK) documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NON-THERMAL X-RAY EMISSION FROM THE NORTHWESTERN RIM OF THE GALACTIC SUPERNOVA REMNANT G266.2-1.2 (RX J0852.0-4622)

We present a detailed spatially resolved spectroscopic analysis of two observations (with a total integration time of 73280 s) made of the X-ray-luminous northwestern rim complex of the Galactic supernova remnant (SNR) G266.2-1.2 (RX J0852.0-4622) with the Chandra X-ray Observatory. G266.2-1.2 is a member of a class of Galactic SNRs which feature X-ray spectra dominated by non-thermal emission: in the cases of these SNRs, the emission is believed to have a synchrotron origin and studies of the X-ray spectra of these SNRs can lend insight into how SNRs accelerate cosmic-ray particles. The Chandra observations have clearly revealed fine structure in this rim complex (including a remarkably well-defined leading shock) and the spectra of these features are dominated by non-thermal emission. We have measured the length scales of the upstream structures at eight positions along the rim and derive lengths of 0.02-0.08 pc (assuming a distance of 750 pc to G266.2-1.2). We have also extracted spectra from seven regions in the rim complex (as sampled by the ACIS-S2, -S3, and -S4 chips) and fit these spectra with such models as a simple power law as well as the synchrotron models SRCUT and SRESC. We have constrained our fits to the latter two models using estimates for the flux densities of these filaments at 1 GHz as determined from radio observations of this rim complex made with the Australia Telescope Compact Array. Statistically acceptable fits to all seven regions are derived using each model: differences in the fit parameters (such as photon index and cutoff frequency) are seen in different regions, which may indicate variations in shock conditions and the maximum energies of the cosmic-ray electrons accelerated at each region. Finally, we estimate the maximum energy of cosmic-ray electrons accelerated along this rim complex to be approximately 40 TeV (corresponding to one of the regions of the leading shock structure assuming a magnetic field strength of 10 {mu}G). We include a summary of estimated maximum energies for both Galactic SNRs as well as SNRs located in the Large Magellanic Cloud. Like these other SNRs, it does not appear that G266.2-1.2 is currently accelerating electrons to the knee energy ({approx}3000 TeV) of the cosmic-ray spectrum. This result is not surprising, as there is some evidence that loss mechanisms which are not important for the accelerated cosmic-ray nucleons at energies just below the knee might cut off electron acceleration.

79 ASTRONOMY AND ASTROPHYSICS↗

Variance components in confocal scanning laser tomography measurements of neuro‐retinal rim area and the effect of repeated measurements on the power to detect loss over time

Abstract Purpose To estimate the variation in measurements of neuro‐retinal rim area (NRA) determined by confocal scanning laser tomography and consequences for clinical follow‐up. Methods Altogether, 24 healthy subjects were randomized on –320 μ m, Moorfields and Standard NRA plane strategies. Additionally, NRA was measured in 32 glaucoma subjects. Variance components for subjects, visits and measurements were estimated with analysis of variance. Sample sizes required to detect a 6.0 × 10 −2 mm 2 NRA change were estimated assuming a significance level of 0.05 and a power of 0.8. Consequences for independent group, and paired comparison design, respectively, were analysed. Further, precision in estimates within subjects over time was investigated. Results The variation of NRA among subjects was considerably larger than the variation among visits and measurements. For glaucoma subjects, the variation among visits and measurements were of the same order but larger than in healthy subjects. It was found that independent group comparisons require inconveniently large sample sizes. Within‐subject paired comparisons over time require sample sizes of below 15 subjects. The estimated variations for glaucoma subjects imply that 54 months of follow‐up is required for detection of change from baseline. Conclusions The variance for subjects is substantial in relation to those for visits and measurements. Cross‐sectional independent group comparisons of levels of NRA are unsuitable, due to considerable subject variation. Levels of NRA differences within subjects between visits can be estimated with acceptable precision. Neuro‐retinal rim area (NRA) measurement can be used for long‐term follow‐up of glaucoma progression.

Sandberg Melin, Camilla↗

Some physiochemical and heavy metal concentration in surface water streams of Tutuka in the Kenyasi mining catchment area

This research was conducted in the Akantansu stream of Tutuka in Kenyasi in the Brong Ahafo Region of Ghana in the months of October and November 2010 and January 2011. The major objectives of the study were to measure levels of pH, BOD (biochemical oxygen demand), lead, chromium, and arsenic in the Akantansu stream of Tutuka and to find ways that the community could ensure safe water use. To achieve the objectives of the study, sampling was done over a period of three months and data was collected and analyzed into graphs and ANOVA tables. The research revealed that the levels of arsenic and BOD were high as compared to the standards of WHO and EPA. If the people of Tutuka continue to use the stream, they may experience negative health effects (e.g., nausea, vomiting, diarrhea, etc.). The level of pH, chromium and lead was acceptable as compared to the standard of WHO and EPA. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗