Search NASA⌕ Search

SEARCH · Search NASA

Results for “active source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Transparent Ceramic Garnet Gamma-Ray Spectrometer With Directionality

We have developed a handheld γ -ray spectrometer based on 1024 pixels, 2.8mm×2.8mm×6 mm in size, of gadolinium–yttrium–gallium–aluminum garnet (GYGAG) ((Gd,Y,Ce) 3 (Ga,Al) 5 O 12 ) ceramic scintillator (total of 48-cm 3 detector volume) coupled to silicon photodiode (SiPD) arrays. The SiPD arrays and readout ASIC, originally developed for medical imaging applications, have been adapted for portability in a lightweight box with heatsink and thermoelectric cooling. Custom readout firmware for γ-ray spectroscopy has been implemented, and a system user interface was developed that runs on an Android tablet. Here, we have optimized the processing of the GYGAG(Ce), the pixel optical coupling, and electronics readout parameters to obtain single pixel energy resolution as good as R(662keV)=3.1 % full-width at half-maximum and full device resolution with singles events from all pixels summed of 4.5%. When Compton-summed events are included, full-energy peak efficiency increases by ~2× , and R(662keV)=4.7 % is obtained for the full device. The pixelated architecture is leveraged to locate point sources of radiological materials using Compton imaging and active masking techniques. Directional detection of a 1 mCi Cs-137 source at 10 m can be made to ±10° in ~2 s.

42 ENGINEERING↗

Diagnostics of a negative hydrogen ion source based on a planar-coil inductively-driven discharge

Recent activity on a volume-production negative-hydrogen-ion source with the design of a matrix of small-radius discharges inductively driven by a planar coil is reported. A single discharge of the matrix has been studied by employing probe-and laser-photodetachment diagnostics. The measurements have been carried out in the first - small-size - chamber of a two-chamber discharge vessel, with rf power introduced by a planar coil positioned on its front wall. The measured profiles of the negative ion density show strong axial dependence, with two maxima located at the positions corresponding to the maxima of the dc potential, where the maxima of the electron density are also located. The first maximum is in the vicinity of the rf power input and the second one is close to the interface between the two chambers of the discharge vessel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AEGIS: A MULTIWAVELENGTH STUDY OF SPITZER POWER-LAW GALAXIES

This paper analyzes a sample of 489 Spitzer/Infrared Array Camera (IRAC) sources in the Extended Groth Strip (EGS), whose spectral energy distributions fit a red power law (PL) from 3.6 to 8.0 {mu}m. The median redshift for sources with known redshifts is (z) = 1.6. Though all or nearly all of the sample galaxies are likely to be active galactic nuclei (AGNs), only 33% were detected in the EGS X-ray survey (AEGIS-X) using 200 ks Chandra observations. The detected sources are X-ray luminous with L {sub X}>10{sup 43} erg s{sup -1} and moderately to heavily obscured with N {sub H}>10{sup 22} cm{sup -2}. Stacking the X-ray-undetected sample members yields a statistically significant X-ray signal, suggesting that they are on average more distant or more obscured than sources with X-ray detections. The ratio of X-ray to mid-infrared fluxes suggests that a substantial fraction of the sources undetected in X-rays are obscured at the Compton-thick level, in contrast to the X-ray-detected sources, all of which appear to be Compton thin. For the X-ray-detected PL sources with redshifts, an X-ray luminosity L {sub X} {approx} 10{sup 44} erg s{sup -1} marks a transition between low-luminosity, blue sources dominated by the host galaxy to high-luminosity, red PL sources dominated by nuclear activity. X-ray-to-optical ratios, infrared variability, and 24 {mu}m properties of the sample are consistent with the identification of infrared PL sources as active nuclei, but a rough estimate is that only 22% of AGNs are selected by the PL criteria. Comparison of the PL selection technique and various IRAC color criteria for identifying AGNs confirms that high-redshift samples selected via simple IRAC colors may be heavily contaminated by starlight-dominated objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Capabilities of the INL ZPPR to Support Active Interrogation Research with SNM

For over 40 years Idaho National Laboratory (INL) and its predecessor organizations have maintained and operated the Zero-Power Physics Reactor (ZPPR) as a test bed for studying reactor physics and nuclear reactor design. Although the ZPPR is no longer operated as an active research reactor, it’s infrastructure (radiation shielding, safety systems, physical safeguards) and special nuclear material (SNM) inventory (variably enriched uranium and plutonium fuels available in metallic, oxide, alloy, and other forms) still makes the facility a unique national resource for research and development activities involving the use of SNM. Recently INL has utilized this facility to serve as a test and evaluation facility for active interrogation research and development. This facility is currently hosting scoping experiments using neutron and x-ray radiation sources to characterize SNM active interrogation signatures and to develop tools and techniques to detect and identify shielded SNM. This paper presents an overview of the facility’s infrastructure and assets and describes recent active interrogation experiments that have taken place using high-energy x-ray sources and compact electronic neutron generators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization, Scale-Up, and Design of Coal-Dependent Methanogenesis in Preparation for In Situ Field Demonstration (Final Report)

Coal deposits are a widespread energy resource on Earth, and the associated CBM represents a significant portion of the world’s natural gas reserves. In deep coal beds, CBM can be a by-product of coalification processes at elevated temperature and pressure and is referred to as thermogenic gas. In shallower coal seams, CBM formation is the result of microbial transformation of organic matter into methane gas (CH 4 ) via methanogenesis, involving the syntrophic cooperation of fermenting and acetogenic bacteria with methanogenic archaea. Biogenic gas, including microbial CBM, can contribute up to 20% of the gas resources on Earth. A large portion of coal deposits in the US (ca. 35%) reside in the PRB located in Montana and Wyoming which are the focus of the present study. The isotopic composition of dissolved gases ( 13 CH 4 and 13 CO 2 ) in the formation water of PRB coal beds is indicative of active methanogenesis as the dominant source of gas in the basin. These low-rank (subbituminous) coal beds provide higher proportions of bioavailable macerals that favor biogenic gas formation in the subsurface. Estimates for the microbial CBM produced from the PRB coal beds over the past decades, range from 15 to 30 trillion ft 3 recovered from over 17,000 active wells. While most of the coal in the PRB is unminable, CBM can be extracted and its combustion produces less atmospheric emissions of greenhouse gases than oil or coal.

Fields, Matthew↗

Isolation, enzyme-bound structure and antibacterial activity of platencin A[subscript 1] from Streptomyces platensis

Natural products continue to serve as one of the best sources for discovery of antibacterial agents as exemplified by the recent discoveries of platensimycin and platencin. Chemical modifications as well as discovery of congeners are the main sources for gaining knowledge of structure-activity relationship of natural products. Screening for congeners in the extracts of the fermentation broths of Streptomyces platensis led to the isolation of platencin A{sub 1}, a hydroxy congener of platencin. The hydroxylation of the tricyclic enone moiety negatively affected the antibacterial activity and appears to be consistent with the hydrophobic binding pocket of the FabF. Isolation, structure, enzyme-bound structure and activity of platencin A{sub 1} and two other congeners have been described.

59 BASIC BIOLOGICAL SCIENCES↗

In-Situ-Reduced Synthesis of Ti 3+ Self-Doped TiO 2 /g-C 3 N 4 Heterojunctions with High Photocatalytic Performance under LED Light Irradiation

A simple one-step calcination route was used to prepare Ti3+ self-doped TiO2/g-C3N4 heterojunctions by mixture of H2Ti3O7 and melamine. X-ray diffraction (XRD), transmission electron microscopy (TEM), high-resolution transmission electron microscopy (HRTEM), X-ray photoelectron spectroscopy (XPS), electron spin resonance (ESR) spectroscopy, and UV-Vis diffuse reflectance spectroscopy (UV-vis DRS) technologies were used to characterize the structure, crystallinity, morphology, and chemical state of the as-prepared samples. The absorption of the prepared Ti3+ self-doped TiO2/g-C3N4 heterojunctions shifted to a longer wavelength region in comparison with pristine TiO2 and g-C3N4. The photocatalytic activities of the heterojunctions were studied by degrading methylene blue under a 30 W visible-light-emitting diode irradiation source. The visible-light photocatalytic activities enhanced by the prepared Ti3+ self-doped TiO2/g-C3N4 heterojunctions were observed and proved to be better than that of pure TiO2 and g-C3N4. The photocatalysis mechanism was investigated and discussed. The intensive separation efficiency of photogenerated electron-hole in the prepared heterojunction was confirmed by photoluminescence (PL) spectra. The removal rate constant reached 0.038 min(-1) for the 22.3 wt % Ti3+ self-doped TiO2/g-C3N4 heterojunction, which was 26.76 and 7.6 times higher than that of pure TiO2 and g-C3N4, respectively. The established heterojunction between the interfaces of TiO2 nanoparticles and g-C3N4 nanosheets as well as introduced Ti3+ led to the rapid electron transfer rate and improved photoinduced electron-hole pair's separation efficiency, resulting in the improved photocatalytic performance of the Ti3+ self-doped TiO2/g-C3N4 heterojunctions.

LED light source↗

SPITZER- AND HERSCHEL-BASED SPECTRAL ENERGY DISTRIBUTIONS OF 24 {mu}m BRIGHT z {approx} 0.3-3.0 STARBURSTS AND OBSCURED QUASARS

In this paper, we characterize the infrared spectral energy distributions (SEDs) of mid-IR-selected z {approx} 0.3-3.0 and L{sub IR} {approx} 10{sup 11}-10{sup 13} L{sub Sun} galaxies, and study how their SEDs differ from those of local and high-z analogs. Infrared SEDs depend both on the power source (AGN or star formation) and the dust distribution. Therefore, differences in the SEDs of high-z and local galaxies provide clues as to differences in their physical conditions. Our mid-IR flux-limited sample of 191 sources is unique in size, and spectral coverage, including Spitzer mid-IR spectroscopy. Here, we add Herschel photometry at 250 {mu}m, 350 {mu}m, and 500 {mu}m, which allows us, through fitting an empirical SED model, to obtain accurate total IR luminosities, as well as constrain the relative contributions of AGNs and starbursts to those luminosities. Our sample includes three broad categories of SEDs: {approx}23% of the sources are AGNs (i.e., where the AGN contributes >50% of L{sub IR}), {approx}30% are starbursts where an AGN contributes <20% of L{sub IR}, and the mid-IR spectra are starburst-like (i.e., strong polycyclic aromatic hydrocarbon features); and the largest group ({approx}47%) are composites which show both significant AGN and starburst activity. The AGN-dominated sources divide into ones that show a strong silicate 9.7 {mu}m absorption feature, implying highly obscured systems, and ones that do not. The high-{tau}{sub 9.7} sources are half of our z > 1.2 AGNs, but show SEDs that are extremely rare among local AGNs. The 30% of the sample that are starbursts, even the z {approx} 2, L{sub IR} {approx} 10{sup 13} L{sub Sun} ones, have lower far-IR to mid-IR continuum ratios than local Ultra Luminous Infrared Galaxies (ULIRGs) or the z {approx} 2 sub-mm galaxies-effectively the SEDs of our z {approx} 2 starburst-dominated ULIRGs are much closer to those of local Luminous Infrared Galaxies than ULIRGs. This is consistent with our earlier finding that, unlike local ULIRGs, our high-z starbursts are typically only in the early stages of a merger. The SEDs of the composite sources are most similar to the local archetypal warm ULIRG, Mrk231, which supports the interpretation of their consisting of both AGN and starburst components. In summary, our results show that there is strong evolution in the SEDs between local and z {approx} 2 IR-luminous galaxies, as well as that there is a wide range of SEDs among high redshift IR-luminous sources. The publicly available SED templates we derive from our sample will be particularly useful for infrared population synthesis models, as well as in the interpretation of other mid-IR high-z galaxies, in particular those detected by the recent all sky Wide-field Infrared Survey Explorer.

79 ASTRONOMY AND ASTROPHYSICS↗

Type B package for the transport of large medical and industrial sources

AREVA Federal Services LLC, under contract to the Los Alamos National Laboratory's Offsite Source Recovery Project, is developing a new Type B(U)-96 package for the transport of unwanted or abandoned high activity gamma and neutron radioactive sealed sources (sources). The sources were used primarily in medical or industrial devices, and are of domestic (USA) or foreign origin. To promote public safety and mitigate the possibility of loss or misuse, the Offsite Source Recovery Project is recovering and managing sources worldwide. The package, denoted the LANL-B, is designed to accommodate the sources within an internal gamma shield. The sources are located either in the IAEA's Long Term Storage Shield (LTSS), or within intact medical or industrial irradiation devices. As the sources are already shielded separately, the package does not include any shielding of its own. A particular challenge in the design of the LANL-B has been weight. Since the LTSS shield weighs approximately 5,000 lb [2,270 kg], and the total package gross weight must be limited to 10,000 lb [4,540 kg], the net weight of the package was limited to 5,000 lb, for an efficiency of 50% (i.e., the payload weight is 50% of the gross weight of the package). This required implementation of a light-weight bell-jar concept, in which the containment takes the form of a vertical bell which is bolted to a base. A single impact limiter is used on the bottom, to protect the elastomer seals and bolted joint. A top-end impact is mitigated by the deformation of a tori spherically-shaped head. Impacts in various orientations on the bottom end are mitigated by a cylindrical, polyurethane foam-filled impact limiter. Internally, energy is absorbed using honeycomb blocks at each end, which fill the torispherical head volumes. As many of the sources are considered to be in normal form, the LANL-B package offers leak-tight containment using an elastomer seal at the joint between the bell and the base, as well as on the single vent port. Leak testing prior to transport may be either using helium mass spectrometry or the pressure-rise concept.

07 ISOTOPE AND RADIATION SOURCES↗

STELLAR CLUSTERS IN THE NGC 6334 STAR-FORMING COMPLEX

The full stellar population of NGC 6334, one of the most spectacular regions of massive star formation in the nearby Galaxy, has not been well sampled in past studies. We analyze here a mosaic of two Chandra X-ray Observatory images of the region using sensitive data analysis methods, giving a list of 1607 faint X-ray sources with arcsecond positions and approximate line-of-sight absorption. About 95% of these are expected to be cluster members, most lower mass pre-main-sequence stars. Extrapolating to low X-ray levels, the total stellar population is estimated to be 20,000-30,000 pre-main-sequence stars. The X-ray sources show a complicated spatial pattern with {approx}10 distinct star clusters. The heavily obscured clusters are mostly associated with previously known far-infrared sources and radio H II regions. The lightly obscured clusters are mostly newly identified in the X-ray images. Dozens of likely OB stars are found, both in clusters and dispersed throughout the region, suggesting that star formation in the complex has proceeded over millions of years. A number of extraordinarily heavily absorbed X-ray sources are associated with the active regions of star formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhanced Cellulose Degradation Using Cellulase-Nanosphere Complexes

Enzyme catalyzed conversion of plant biomass to sugars is an inherently inefficient process, and one of the major factors limiting economical biofuel production. This is due to the physical barrier presented by polymers in plant cell walls, including semi-crystalline cellulose, to soluble enzyme accessibility. In contrast to the enzymes currently used in industry, bacterial cellulosomes organize cellulases and other proteins in a scaffold structure, and are highly efficient in degrading cellulose. To mimic this clustered assembly of enzymes, we conjugated cellulase obtained from Trichoderma viride to polystyrene nanospheres (cellulase:NS) and tested the hydrolytic activity of this complex on cellulose substrates from purified and natural sources. Cellulase:NS and free cellulase were equally active on soluble carboxymethyl cellulose (CMC); however, the complexed enzyme displayed a higher affinity in its action on microcrystalline cellulose. Similarly, we found that the cellulase:NS complex was more efficient in degrading natural cellulose structures in the thickened walls of cultured wood cells. These results suggest that nanoparticle-bound enzymes can improve catalytic efficiency on physically intractable substrates. We discuss the potential for further enhancement of cellulose degradation by physically clustering combinations of different glycosyl hydrolase enzymes, and applications for using cellulase:NS complexes in biofuel production.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluating the purity of a {sup 57}Co flood source by PET

Purpose: Flood sources of {sup 57}Co are commonly used for quality control of gamma cameras. Flood uniformity may be affected by the contaminants {sup 56}Co and {sup 58}Co, which emit higher energy photons. Although vendors specify a maximum combined {sup 56}Co and {sup 58}Co activity, a convenient test for flood source purity that is feasible in a clinical environment would be desirable. Methods: Both {sup 56}Co and {sup 58}Co emit positrons with branching 19.6% and 14.9%, respectively. As is known from {sup 90}Y imaging, a positron emission tomography (PET) scanner is capable of quantitatively imaging very weak positron emission in a high single-photon background. To evaluate this approach, two {sup 57}Co flood sources were scanned with a clinical PET/CT multiple times over a period of months. The {sup 56}Co and {sup 58}Co activity was clearly visible in the reconstructed PET images. Total impurity activity was quantified from the PET images after background subtraction of prompt gamma coincidences. Results: Time-of-flight PET reconstruction was highly beneficial for accurate image quantification. Repeated measurements of the positron-emitting impurities showed excellent agreement with an exponential decay model. For both flood sources studied, the fit parameters indicated a zero intercept and a decay half-life consistent with a mixture of {sup 56}Co and {sup 58}Co. The total impurity activity at the reference date was estimated to be 0.06% and 0.07% for the two sources, which was consistent with the vendor’s specification of <0.12%. Conclusions: The robustness of the repeated measurements and a thorough analysis of the detector corrections and physics suggest that the accuracy is acceptable and that the technique is feasible. Further work is needed to validate the accuracy of this technique with a calibrated high resolution gamma spectrometer as a gold standard, which was not available for this study, and for other PET detector models.

07 ISOTOPE AND RADIATION SOURCES↗

The Effect of CO 2 on the Measurement of 220 Rn and 222 Rn with Instruments Utilising Electrostatic Precipitation

In some volcanic systems, thoron and radon activity and CO 2 flux, in soil and fumaroles, show a relationship between ( 220 Rn/ 222 Rn) and CO 2 efflux. It is theorized that deep, magmatic sources of gas are characterized by high 222 Rn activity and high CO 2 efflux, whereas shallow sources are indicated by high 220 Rn activity and relatively low CO 2 efflux. In this paper we evaluate whether the observed inverse relationship is a true geochemical signal, or potentially an analytical artifact of high CO 2 concentrations. We report results from a laboratory experiment using the RAD7 radon detector, known 222 Rn (radon) and 220 Rn (thorn), and a controllable percentage of CO 2 in the carrier gas. Our results show that for every percentage of CO 2 , the 220 Rn reading should be multiplied by 1.019, the 222 Rn radon should be multiplied by 1.003 and the 220 Rn/ 222 Rn ratio should be multiplied by 1.016 to correct for the presence of the CO 2 .

58 GEOSCIENCES↗

DECIPHERING CONTRIBUTIONS TO THE EXTRAGALACTIC GAMMA-RAY BACKGROUND FROM 2 GeV TO 2 TeV

Astrophysical sources outside the Milky Way, such as active galactic nuclei and star-forming galaxies, leave their imprint on the gamma-ray sky as nearly isotropic emission referred to as the extragalactic gamma-ray background (EGB). While the brightest of these sources may be individually resolved, their fainter counterparts contribute diffusely. In this work, we use a recently developed analysis method, called the Non-Poissonian Template Fit, on up to 93 months of publicly available data from the Fermi Large Area Telescope to determine the properties of the point sources (PSs) that comprise the EGB. This analysis takes advantage of photon-count statistics to probe the aggregate properties of these source populations below the sensitivity threshold of published catalogs. We measure the source-count distributions and PS intensities, as a function of energy, from ∼2 GeV to 2 TeV. We find that the EGB is dominated by PSs, likely blazars, in all seven energy sub-bins considered. These results have implications for the interpretation of IceCube’s PeV neutrinos, which may originate from sources that contribute to the non-blazar component of the EGB. Additionally, we comment on implications for future TeV observatories such as the Cherenkov Telescope Array. We provide sky maps showing locations most likely to contain these new sources at both low (≲50 GeV) and high (≳50 GeV) energies for use in future observations and cross-correlation studies.

79 ASTRONOMY AND ASTROPHYSICS↗

DISCOVERY AND MONITORING OF A NEW BLACK HOLE CANDIDATE XTE J1752-223 WITH RXTE: RMS SPECTRUM EVOLUTION, BLACK HOLE MASS, AND THE SOURCE DISTANCE

We report on the discovery and monitoring observations of a new galactic black hole (BH) candidate XTE J1752-223 by Rossi X-ray Timing Explorer (RXTE). The new source appeared on the X-ray sky on 2009 October 21 and was active for almost 8 months. Phenomenologically, the source exhibited the low-hard/high-soft spectral state bi-modality and the variability evolution during the state transition that matches standard behavior expected from a stellar mass BH binary. We model the energy spectrum throughout the outburst using a generic Comptonization model assuming that part of the input soft radiation in the form of a blackbody spectrum gets reprocessed in the Comptonizing medium. We follow the evolution of fractional root-mean-square (rms) variability in the RXTE/PCA energy band with the source spectral state and conclude that broadband variability is strongly correlated with the source hardness (or Comptonized fraction). We follow changes in the energy distribution of rms variability during the low-hard state and the state transition, and find further evidence that variable emission is strongly concentrated in the power-law spectral component. We discuss the implication of our results to the Comptonization regimes during different spectral states. Correlations of spectral and variability properties provide measurements of the BH mass and distance to the source. The spectral-timing correlation scaling technique applied to the RXTE observations during the hard-to-soft state transition indicates a mass of the BH in XTE J1752-223 between 8 and 11 solar masses and a distance to the source of about 3.5 kpc.

79 ASTRONOMY AND ASTROPHYSICS↗

THREE-DIMENSIONAL STRUCTURE OF MICROWAVE SOURCES FROM SOLAR ROTATION STEREOSCOPY VERSUS MAGNETIC EXTRAPOLATIONS

We use rotation stereoscopy to estimate the height of a steady-state solar feature relative to the photosphere, based on its apparent motion in the image plane recorded over several days of observation. The stereoscopy algorithm is adapted to work with either one- or two-dimensional data (i.e., from images or from observations that record the projected position of the source along an arbitrary axis). The accuracy of the algorithm is tested on simulated data, and then the algorithm is used to estimate the coronal radio source heights associated with the active region NOAA 10956, based on multifrequency imaging data over seven days from the Siberian Solar Radio Telescope near 5.7 GHz, the Nobeyama Radio Heliograph at 17 GHz, as well as one-dimensional scans at multiple frequencies spanning the 5.98-15.95 GHz frequency range from the RATAN-600 instrument. The gyroresonance emission mechanism, which is sensitive to the coronal magnetic field strength, is applied to convert the estimated radio source heights at various frequencies, h(f), to information about magnetic field versus height B(h), and the results are compared to a magnetic field extrapolation derived from photospheric magnetic field observations obtained by Hinode and Michelson Doppler Imager. We found that the gyroresonant emission comes from heights exceeding the location of the third gyrolayer irrespective of the magnetic extrapolation method; implications of this finding for coronal magnetography and coronal plasma physics are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

THE DUST TAIL OF ASTEROID (3200) PHAETHON

We report the discovery of a comet-like tail on asteroid (3200) Phaethon when imaged at optical wavelengths near perihelion. In both 2009 and 2012, the tail appears {approx}>350'' (2.5 Multiplication-Sign 10{sup 8} m) in length and extends approximately in the projected anti-solar direction. We interpret the tail as being caused by dust particles accelerated by solar radiation pressure. The sudden appearance and the morphology of the tail indicate that the dust particles are small, with an effective radius {approx}1 {mu}m and a combined mass {approx}3 Multiplication-Sign 10{sup 5} kg. These particles are likely products of thermal fracture and/or desiccation cracking under the very high surface temperatures ({approx}1000 K) experienced by Phaethon at perihelion. The existence of the tail confirms earlier inferences about activity in this body based on the detection of anomalous brightening. Phaethon, the presumed source of the Geminid meteoroids, is still active.

79 ASTRONOMY AND ASTROPHYSICS↗

Air-kerma strength determination of a new directional {sup 103}Pd source

Purpose: A new directional {sup 103}Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing {sup 103}Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active {sup 103}Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S{sub K}) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S{sub K} to a well-type ionization chamber. Methods: S{sub K} measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S{sub K} from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S{sub K} with the presence of gold fluorescent energy lines. In addition to S{sub K} measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S{sub K} values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S{sub K} of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an S{sub K}-based calibration to a clinical user. S{sub K} per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the S{sub K} measurement approach. Conclusions: This characterization of a new {sup 103}Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield.

07 ISOTOPE AND RADIATION SOURCES↗