Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

THE EAST-WEST METHOD: AN EXPOSURE-INDEPENDENT METHOD TO SEARCH FOR LARGE-SCALE ANISOTROPIES OF COSMIC RAYS

The measurement of large-scale anisotropies in cosmic ray arrival directions at energies above 10{sup 13} eV is performed through the detection of extensive air showers (EAS) produced by cosmic ray interactions in the atmosphere. The observed anisotropies are small, so accurate measurements require small statistical uncertainties, i.e., large data sets. These can be obtained by employing ground detector arrays with large extensions (from 10{sup 4} to 10{sup 9} m{sup 2}) and long operation time (up to 20 years). The control of such arrays is challenging and spurious variations in the counting rate due to instrumental effects (e.g., data taking interruptions or changes in the acceptance) and atmospheric effects (e.g., air temperature and pressure effects on EAS development) are usually present. These modulations must be corrected very precisely before performing standard anisotropy analyses, i.e., harmonic analysis of the counting rate versus local sidereal time. In this paper we discuss an alternative method to measure large-scale anisotropies, the 'East-West method'. It was originally proposed in the 1940s to study asymmetries in the flux of solar cosmic rays and later applied by Nagashima et al. to EAS at higher energies. It is a differential method, as it is based on the analysis of the difference of the counting rates in the east and west directions. Besides explaining the principle, we present here its mathematical derivation, showing that the method is largely independent of experimental effects, that is, it does not require corrections for acceptance and/or for atmospheric effects. We explain the use of the method to derive the amplitude and phase of the anisotropy and demonstrate its power under different conditions of detector operation.

79 ASTRONOMY AND ASTROPHYSICS↗

Isospin symmetry and proton decay: Identification of the 10{sup +} isomer in {sup 54}Ni

The {gamma} decays from an isomeric 10{sup +} state at 6457 keV in the nucleus {sub 28}{sup 54}Ni{sub 26} have been identified using the GSI fragment separator in conjunction with the RISING Ge-detector array. The state is interpreted as the isobaric analog of the 6527-keV 10{sup +} isomer in {sub 26}{sup 54}Fe{sub 28}. The results are discussed in terms of isospin-dependent shell-model calculations. Clear evidence is presented for a discrete l=5 proton decay branch into the first excited 9/2{sup -} state of the daughter {sup 53}Co. This decay is the first of its kind observed following projectile fragmentation reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determininig the (n,{gamma}) cross section of {sup 153}Gd using surrogate reactions

The astrophysical s-process is responsible for the synthesis of many of the nuclei heavier than iron through a series of low-energy (n,{gamma}) reactions and {beta}-decays. For nuclei for which the neutron capture and {beta}-decay rates are comparable, the branching is crucial for tests of s-process models. Direct measurements of (n,{gamma}) cross sections for these nuclei are extremely challenging due to the inherent difficulties associated with radioactive targets and the low intensity of available neutron beams. The surrogate reaction technique can be used to circumvent these difficulties by creating the same compound nucleus through light-ion reactions on a stable target. The cross section can be determined by combining optical model calculations for the formation of the compound nucleus with the measured exit channel probability for {gamma}-ray emission. We have collected data to determine the low-energy (n,{gamma}) cross section for the unstable nucleus {sup 153}Gd by bombarding a stable {sup 154}Gd target with protons from the 88-Inch Cyclotron at the Lawrence Berkeley National Laboratory to create the desired {sup 154}Gd* compound nucleus. The STARS/LiBerACE silicon and clover germanium detector arrays were used to detect {gamma}-rays in coincidence with the scattered protons. Additional cross section measurements using {sup 156}Gd and {sup 158}Gd targets will be compared to direct measurements of the (n,{gamma}) cross sections for {sup 155}Gd and {sup 157}Gd. The current status of the analysis is summarized.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Auxiliary Components for Kilopixel Transition Edge Sensor Arrays

We have fabricated transition edge sensor bolometer focal plane arrays sensitive to mm-submillimeter (0.1-3 THz) radiation for the Atacama Cosmology Telescope (ACT), which will probe the cosmic microwave background at 0.147,0.215, and 0.279 GHz. Central to the performance of these bolometers is a set of auxiliary resistive components. Here we discuss shunt resistors, which allow for tight optimization of bolometer time constant and sensitivity. Our shunt resistors consist of AuPd strips grown atop of interdigitated superconducting MoN, wires. We can tailor the shunt resistance by altering the dimensions of the AuPd strips and the pitch and width of the MoN, wires and can fabricate over 1000 shunts on a single 4" wafer. By modeling the resistance dependence of these parameters, a variety of different 0.77 +I-0.13 mOhm shunt resistors have been fabricated. This variety includes different shunts possessing MoN, wires with wire width equal to 1.5 and 10 microns and pitch equal to 4.5 and 26 microns, respectively. Our ability to set the resistance of the shunts hints at the scalability of our design. We have also integrated a Si02 capping layer into our shunt resistor fabrication scheme, which inhibits metal corrosion and eventual degradation of the shunt. Consequently, their robustness coupled with their high packing density makes these resistive components attractive for future kilopixel detector arrays.

Brown, Ari-David↗

Measurement of the Li 7 ( γ , t ) He 4 ground-state cross section between E γ = 4.4 and 10 MeV

Here, the Li 7 ( γ , t ) He 4 ground state cross section was measured for the first time using monoenergetic γ rays with energies between 4.4 and 10 MeV at the High Intensity Gamma-ray Source. The reaction is important for the primordial Li problem and for testing our understanding of the mirror α -capture reactions H 3 ( α , γ ) Li 7 and He 3 ( α , γ ) Be 7 . Although over the last 30 years most measurements of the H 3 ( α , γ ) Li 7 reaction have concentrated in an energy range below E γ = 3.65 MeV, measurements at higher energies could potentially restrict the extrapolation to astrophysically important energies. The experimental arrangement for measuring the Li 7 ( γ , t ) He 4 reaction included a large-area silicon detector array and several beam characterization instruments. The experimental astrophysical S factor of H 3 ( α , γ ) calculated from the present data was fitted using the R -matrix formalism. The results are in disagreement with previous experimental measurements in the same energy range but the extrapolated S factor agrees with the potential model calculation and lower energy experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-energy Coulomb excitation of neutron-rich zinc isotopes

At the radioactive ion beam facility REX-ISOLDE, neutron-rich zinc isotopes were investigated using low-energy Coulomb excitation. These experiments have resulted in B(E2,2{sub 1}{sup +}{yields}0{sub 1}{sup +}) values in {sup 74-80}Zn, B(E2,4{sub 1}{sup +}{yields}2{sub 1}{sup +}) values in {sup 74,76}Zn and the determination of the energy of the first excited 2{sub 1}{sup +} states in {sup 78,80}Zn. The zinc isotopes were produced by high-energy proton- (A=74,76,80) and neutron- (A=78) induced fission of {sup 238}U, combined with selective laser ionization and mass separation. The isobaric beam was postaccelerated by the REX linear accelerator and Coulomb excitation was induced on a thin secondary target, which was surrounded by the MINIBALL germanium detector array. In this work, it is shown how the selective laser ionization can be used to deal with the considerable isobaric beam contamination and how a reliable normalization of the experiment can be achieved. The results for zinc isotopes and the N=50 isotones are compared to collective model predictions and state-of-the-art large-scale shell-model calculations, including a recent empirical residual interaction constructed to describe the present experimental data up to 2004 in this region of the nuclear chart.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

0{sub gs}{sup +}{yields}2{sub 1}{sup +} Transition Strengths in {sup 106}Sn and {sup 108}Sn

The reduced transition probabilities, B(E2;0{sub gs}{sup +}{yields}2{sub 1}{sup +}), have been measured in the radioactive isotopes {sup 108,106}Sn using subbarrier Coulomb excitation at the REX-ISOLDE facility at CERN. Deexcitation {gamma} rays were detected by the highly segmented MINIBALL Ge-detector array. The results, B(E2;0{sub gs}{sup +}{yields}2{sub 1}{sup +})=0.222(19)e{sup 2}b{sup 2} for {sup 108}Sn and B(E2;0{sub gs}{sup +}{yields}2{sub 1}{sup +})=0.195(39)e{sup 2}b{sup 2} for {sup 106}Sn were determined relative to a stable {sup 58}Ni target. The resulting B(E2) values are {approx}30% larger than shell-model predictions and deviate from the generalized seniority model. This experimental result may point towards a weakening of the N=Z=50 shell closure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards combining in-beam {gamma}-ray and conversion electron spectroscopy

The SAGE spectrometer will combine a segmented Si-detector with a Ge-detector array aiming to take the simultaneous in-beam {gamma}-ray and conversion electron spectroscopy to the next level. It will be coupled with the GREAT focal plane spectrometer and the RITU gas-filled recoil separator at the accelerator laboratory of the University of Jyvaeskylae, Finland. Its high efficiency and resolution will open the door to a new era of complete spectroscopy directed, amongst others, at the study of superheavy nuclei aiming to investigate the properties of the next spherical proton shell above Z = 82.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-218: Validation of An In-Vivo Proton Range Verification Method for Reducing the Risk of Permanent Alopecia in the Treatment of Pediatric Medulloblastoma

Purpose: The clinical commissioning of a workflow for pre-treatment range verification/adjustment for the head treatment of pediatric medulloblastoma patients, including dose monitoring during treatment. Methods: An array of Si-diodes (DIODES Incorporated) is placed on the patient skin on the opposite side to the beam entrance. A “scout” SOBP beam, with a longer beam range to cover the diodes in its plateau, is delivered; the measured signal is analyzed and the extracted water equivalent path lengths (WEPL) are compared to the expected values, revealing if a range correction is needed. Diodes stay in place during treatment to measure dose. The workflow was tested in solid water and head phantoms and validated against independent WEPL measurements. Both measured WEPL and skin doses were compared to computed values from the TPS (XiO); a Markus chamber was used for reference dose measurements. Results: The WEPL accuracy of the method was verified by comparing it with the dose extinction method. It resulted, for both solid water and head phantom, in the sub-millimeter range, with a deviation less than 1% to the value extracted from the TPS. The accuracy of dose measurements in the fall-off part of the dose profile was validated against the Markus chamber. The entire range verification workflow was successfully tested for the mock-treatment of head phantom with the standard delivery of 90 cGy per field per fraction. The WEPL measurement revealed no need for range correction. The dose measurements agreed to better than 4% with the prescription dose. The robustness of the method and workflow, including detector array, hardware set and software functions, was successfully stress-tested with multiple repetitions. Conclusion: The performance of the in-vivo range verification system and related workflow meet the clinical requirements in terms of the needed WEPL accuracy for pretreatment range verification with acceptable dose to the patient.

60 APPLIED LIFE SCIENCES↗

Single-Neutron States in {sup 101}Sn

A search for {gamma}-ray transitions in {sup 101}Sn, which contains only one neutron outside the {sup 100}Sn core, was carried out at the Argonne Tandem-Linac Accelerator System. {sup 101}Sn nuclei were produced using the {sup 46}Ti({sup 58}Ni,3n){sup 101}Sn reaction. In-beam {gamma} rays were detected in the Gammasphere Ge-detector array and were correlated with {sup 101}Sn {beta}-delayed protons using the Recoil-Decay Tagging method. A {gamma}-ray line at 172 keV was assigned to {sup 101}Sn and was interpreted as the transition between the single-neutron g{sub 7/2} and d{sub 5/2} states. The measured {nu}g{sub 7/2}-{nu} d5/2 energy splitting is compared with predictions of various mean-field potentials. It is also used to calculate multi-neutron configurations in light Sn isotopes. Prospects of using {beta}-delayed protons for tagging other exotic nuclei in the {sup 100}Sn region are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prompt and delayed spectroscopy of {sup 199}At

The neutron-deficient nucleus {sup 199}At has been studied through {gamma}-ray and electron spectroscopy, using the recoil-decay tagging technique. Two experiments were conducted, using a gas-filled recoil separator with a focal-plane spectrometer alone and together with a germanium-detector array at the target position. The resulting level scheme for {sup 199}At includes a new isomer with a half-life of 0.80(5) {mu}s and a spin and parity of (29/2{sup +}). The 13/2{sup +} isomer, which de-excites via an M2 transition to the 9/2{sup -} ground state, was measured to have a half-life of 70(20) ns. Our earlier version of the level scheme for {sup 197}At has been updated as well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence for the Importance of Soft Deformation Potentials in Strongly Deformed Nuclei

Excited states of {sup 168}Hf were populated using the {sup 124}Sn({sup 48}Ti,4n) fusion evaporation reaction at the WNSL of Yale University. The lifetimes of the J{sup {pi}} = 4{sup +},6{sup +},8{sup +}, and 10{sup +} levels along the ground state band of {sup 168}Hf were measured by means of the recoil distance Doppler shift (RDDS) method using the New Yale Plunger Device (NYPD) and the SPEEDY Ge detector array. The new lifetime values are sufficiently precise to clearly prove the increase of quadrupole collectivity as a function of angular momentum in the deformed nucleus {sup 168}Hf. The data agree with the predictions from the geometrical Confined {beta}-Soft (CBS) rotor model that involves centrifugal stretching in a soft potential. Relative and absolute E0 transition strengths [{rho}{sup 2}(E0)] on the transitional path between X(5) and the Rigid Rotor Limit have been evaluated within the framework of the CBS rotor model, too. Relative inter-band E0 transition strengths decrease with increasing angular momentum for a given potential stiffness, while for increasing potential stiffness, the absolute E0 transition strengths decrease with increasing angular momentum and increasing potential stiff0010ne.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution measurement of absolute {alpha}-decay widths in {sup 16}O

By using a large-acceptance position-sensitive silicon detector array in coincidence with the high-resolution Munich Q3D spectrograph, unambiguous measurements have been made of the absolute {alpha}-particle decay widths from excited states in {sup 16}O* in the energy range 13.85 to 15.87 MeV. Carbon targets have been bombarded with 42-MeV {sup 6}Li beams to induce {sub 6}{sup 12}C({sub 3}{sup 6}Li, d){sub 8}{sup 16}O* reactions. The deuteron ejectiles were measured in the Q3D and the results gated by {sup 4}He+{sup 12}C breakup products detected in the silicon array, the efficiency of which was modeled using Monte Carlo simulations. By comparing total population and breakup-gated spectra, the following absolute {alpha}-decay widths have been measured with high resolution: {Gamma}{sub {alpha}}0/{Gamma}{sub tot} = 0.87{+-}0.11 (13.980 MeV), 1.04{+-}0.15 (14.302 MeV), 0.92{+-}0.10 (14.399 MeV), 0.59{+-}0.04 (14.815 MeV), 0.88{+-}0.18 (15.785 MeV), and {Gamma}{sub {alpha}}1/{Gamma}{sub tot}=1.14{+-}0.08 (14.660 MeV), 0.46{+-}0.06 (14.815 MeV).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Conversion of experimental half-life to effective electron neutrino mass in 0nubetabeta decay

The Germanium Detector Array (GERDA) collaboration will be searching for neutrinoless double beta decay of {sup 76}Ge. As a result it will measure the half-life T{sub 1/2} of this rare process; or at least a new value for the lower limit for T{sub 1/2} will be derived. The sensitivity of the GERDA experiment on the effective electron neutrino mass <m{sub b}eta{sub b}eta> depends on the theoretical value for the nuclear matrix element M and the kinematical phase space factor G.In this Brief Report we focus on existing difficulties in applying the dimensionless values of M calculated by various theoretical groups, which use different methods and parametrizations. The implicit radius dependencies in M and G are discussed. Resulting values of the neutrino mass are tabulated for various representative half-lives T{sub 1/2} representing the sensitivity of the various phases of the GERDA experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Spectroscopy of neutron-rich {sup 168,170}Dy: Yrast band evolution close to the N{sub p}N{sub n} valence maximum

The yrast sequence of the neutron-rich dysprosium isotope {sup 168}Dy has been studied using multinucleon transfer reactions following collisions between a 460-MeV {sup 82}Se beam and an {sup 170}Er target. The reaction products were identified using the PRISMA magnetic spectrometer and the gamma rays detected using the CLARA HPGe-detector array. The 2{sup +} and 4{sup +} members of the previously measured ground-state rotational band of {sup 168}Dy have been confirmed and the yrast band extended up to 10{sup +}. A tentative candidate for the 4{sup +}->2{sup +} transition in {sup 170}Dy was also identified. The data on these nuclei and on the lighter even-even dysprosium isotopes are interpreted in terms of total Routhian surface calculations and the evolution of collectivity in the vicinity of the proton-neutron valence product maximum is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for coherent elastic neutrino-nucleus scattering at a nuclear reactor with CONNIE 2019 data

The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) is taking data at the Angra 2 nuclear reactor with the aim of detecting the coherent elastic scattering of reactor antineutrinos with silicon nuclei using charge-coupled devices (CCDs). In 2019 the experiment operated with a hardware binning applied to the readout stage, leading to lower levels of readout noise and improving the detection threshold down to 50 eV. The results of the analysis of 2019 data are reported here, corresponding to the detector array of 8 CCDs with a fiducial mass of 36.2 g and a total exposure of 2.2 kg-days. The difference between the reactor-on and reactor-off spectra shows no excess at low energies and yields upper limits at 95% confidence level for the neutrino interaction rates. In the lowest-energy range, 50 − 180 eV, the expected limit stands at 34 (39) times the standard model prediction, while the observed limit is 66 (75) times the standard model prediction with Sarkis (Chavarria) quenching factors.[graphic not available: see fulltext]

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗