Search NASA⌕ Search

SEARCH · Search NASA

Results for “arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Simulation studies of the high-energy component of a future imaging Cherenkov telescope array

The current generation of Imaging Atmospheric telescopes (IACTs) has demonstrated the power of the technique in an energy range between {approx}100 GeV up to several tens of TeV. At the high-energy end, these instruments are limited by photon statistics. Future arrays of IACTs such as CTA or AGIS are planned to push into the energy range beyond 100 TeV. Scientifically, this region is very promising, providing a probe of particles up to the 'knee' in the cosmic ray spectrum and access to an unexplored region in the spectra of nearby extragalactic sources. We present first results from our simulation studies of the high-energy part of a future IACT array and discuss the design parameters of such an array.

79 ASTRONOMY AND ASTROPHYSICS↗

A Topological Array Trigger for AGIS, the Advanced Gamma ray Imaging System

Next generation ground based {gamma}-ray observatories such as AGIS{sup 1} and CTA{sup 2} are expected to cover a 1 km{sup 2} area with 50-100 imaging atmospheric Cherenkov telescopes. The stereoscopic view ol air showers using multiple view points raises the possibility to use a topological array trigger that adds substantial flexibility, new background suppression capabilities and a reduced energy threshold. In this paper we report on the concept and technical implementation of a fast topological trigger system, that makes use of real time image processing of individual camera patterns and their combination in a stereoscopic array analysis. A prototype system is currently under construction and we discuss the design and hardware of this topological array trigger system.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative Analysis of Plasma Ablation Using Inverse Wire Array Z-pinches

An inverse (exploding) wire array configuration, in which the wires form a cylinder around a current carrying electrode on axis, was used to study the ablation phase of the pinch. This configuration allows the parameters of the plasma from individual wires of the array to be measured as the ablated plasma streams propagate in the outward radial direction. The density distribution and the evolution of the natural mode of modulation of the ablation was measured with interferometry and soft x-ray imaging. Measurements of the voltage across the array, which in this configuration is determined by the private magnetic flux around the individual wires, allows information on the localisation of the current to be obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3D MHD Simulations of Radial Wire Array Z-pinches

Recent experiments carried out on the MAGPIE (1 MA, 250 ns), OEDIPE (730 kA, 1.5 {mu}s) and SPHINX (4 MA, 700 ns)[1] facilities have shown the relatively high level of scalability of the Radial Wire Array Z-pinches. These configurations where the wires stretch radially outwards from a central cathode offer numerous advantages over standard cylindrical arrays. In particular, imploding in a very stable and compact way, they seem suitable for coupling to small scale hohlraums. Making use of the 3D resistive magneto-hydrodynamic code GORGON[2] developed at Imperial College, the dynamic of the radial wire arrays is investigated. Influence of the cathode hotspots and wires angle on the x-ray emissions is also discussed. Comparison with experiments is offered to validate the numerical studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiative Properties of Implosions of Stainless Steel Wire Arrays with Application to Astrophysics

Experiments with different stainless steel (SS) wire loads were performed on the 1 MA Zebra Z-pinch generator at University of Nevada, Reno. The wire array loads consisted of 7.6 {mu}m SS wires and had 10 wires for the planar wire array with an interwire gap of 1 mm and 8 wires for the cylindrical wire array of a 16 mm diameter. In addition, a single-wire experiment with a 25 {mu}m SS wire was carried out. The different wire loads were used to provide a broader spectrum of plasma conditions. Time-integrated and time-gated x-ray images, as well as time-integrated, spatially-resolved and spatially-integrated x-ray spectra, were collected and analyzed. Both K-shell and L-shell radiation were recorded using LiF and KAP crystal spectrometers, respectively. Non-LTE kinetic models of Fe and Ni are employed to derive plasma parameters. For axially resolved L-shell spectra, the resulting electron temperatures are between 230 and 300 eV (higher near the cathode) and electron densities vary from 10{sup 19} to 10{sup 20} cm{sup -3} dependent on the load. The advantage of using Z-pinch plasmas for astrophysical applications is highlighted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation Hydrodynamics of Stainless Steel Wire Arrays on the Z Accelerator

Experiments on the Z accelerator with nested stainless steel wire arrays produced K-shell x-ray yields exceeding 50 kJ in the energy range 5.5 to 8 keV. Stainless steel (Z = 24-28) can barely be ionized to the K-shell on Z, and the spectra are therefore sensitive to the details of the implosion. We have simulated the implosion dynamics of stainless steel wire arrays with diameters ranging from 4.5 to 8.0 centimeters using a detailed configuration non-LTE radiation hydrodynamics model. Reasonable agreement with total and K-shell experimental yields was obtained for the various array configurations. A comparison is made between the 1-D and 2-D simulations for shot Z-578.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Compact Cylindrical Wire Array Implosions with Brass and also by Alternating Brass and Al wires on the 1-MA COBRA Generator

Implosions from compact cylindrical wire arrays (CCWA) with mid-Z and low-Z wires were carried out on the 1-MA COBRA generator at Cornell University. In particular, the CCWA used either Brass 310 (70% Cu, 30% Zn) wires or a combination of Brass 310 and Al 5056 (95% Al, 5% Mg) wires arranged in an alternating pattern. A total of 16 wires were used on either a 6 or 4 mm diameter array. The diagnostic suite included a bolometer, fast x-ray detectors, a time-integrated spectrometer, and a streak camera. A higher energy output was observed from bolometer measurements when alternating the brass and Al wires compared to using only the brass wires. This study will focus mainly on the spectroscopy of the brass and alternating brass and Al CCWA by applying the non-LTE kinetic models of Cu and Zn to account for the L-shell radiation. The resulting plasma parameters, electron density and electron temperature, will be discussed and compared for the CCWA with only brass wires and alternating brass and Al wires. The simulations with the novel Wire Ablation Dynamics Model that account for wire ablation will be performed to analyze the differences in implosion dynamics of the uniform and alternating compact cylindrical arrays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studies of Hot Spots in Imploding Wire Arrays at 1 MA on COBRA

We present recent results from hot spot investigations in imploding Al wire array z-pinches on the COBRA generator at Cornell University using x-ray diagnostics. Measurements of the temporal and spatial distribution of hot spots in stagnating plasmas by an x-ray streak-camera are included. Experiments show that hot spots have nanosecond lifetime and appear randomly along the array axis after plasma stagnation in secondary pinches in 8 mm diameter and during plasma stagnation in the arrays with 4 mm diameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nucleation Mechanism of Dislocation Half-Loop Arrays in 4H-Silicon Carbide Homo-Epitaxial Layers

A model is presented for the formation mechanism of dislocation half-loop arrays formed during the homoepitaxial growth of 4H-SiC. The reorientation during glide of originally screw oriented threading segments of basal plane dislocation (BPD) renders them susceptible to conversion into sessile threading edge dislocations (TEDs), which subsequently pin the motion of the BPD. Continued glide during further growth enables parts of the mobile BPD to escape through the surface leaving arrays of half loops comprising two TEDs and a short BPD segment with significant edge component. The faulting behavior of the arrays under UV excitation is consistent with this model.

36 MATERIALS SCIENCE↗

Recent Updates to the FAUST Array

Current advances in technology have enabled dramatic improvements to the performance of multi-detector arrays within the last 10 years. FAUST is a forward array of 68 Si-CsI(Tl) detector telescopes that has been in use since 1996. To take full advantage of current technology, FAUST has undergone an overhaul installing new preamplifiers from Zepto Systems and modifications to allow for Dual-Axis Dual-Lateral position sensitive detectors to be installed. A new calibration software package has also been developed utilizing a novel linearization algorithm. The combination of these upgrades has led to isotopic identification for elements in the Z = 1-13 range and has greatly increased the angular resolution of the array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the Photon Strength Functions for Gadolinium Isotopes with the DANCE Array

The gadolinium isotopes are interesting for reactor applications as well as for medicine and astrophysics. The gadolinium isotopes have some of the largest neutron capture cross sections. As a consequence they are used in the control rod in reactor fuel assembly. From the basic science point of view, there are seven stable isotopes of gadolinium with varying degrees of deformation. Therefore they provide a good testing ground for the study of deformation dependent structure such as the scissors mode. Decay gamma rays following neutron capture on Gd isotopes are detected by the DANCE array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a specific resonance of a specific isotope in the time-of-flight spectrum and obtain the summed energy spectrum for that isotope. The singles gamma-ray spectrum for each multiplicity can be separated by their DANCE cluster multiplicity. Various photon strength function models are used for comparison with experimentally measured DANCE data and provide insight for understanding the statistical decay properties of deformed nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Capture Experiments Using the DANCE Array at Los Alamos

The Detector for Advanced Neutron Capture Experiments (DANCE) is designed for neutron capture measurements on very small and/or radioactive targets. The DANCE array of 160 BaF{sub 2} scintillation detectors is located at the Lujan Center at the Los Alamos Neutron Science Center (LANSCE). Accurate measurements of neutron capture data are important for many current applications as well as for basic understanding of neutron capture. The gamma rays following neutron capture reactions have been studied by the time-of-flight technique using the DANCE array. The high granularity of the array allows measurements of the gamma-ray multiplicity. The gamma-ray multiplicities and energy spectra for different multiplicities can be measured and analyzed for spin and parity determination of the resolved resonances.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CoCrPt antidot arrays with perpendicular magnetic anisotropy made on anodic alumina templates

Ti(5 nm)/CoCrPt(5-20 nm) bilayers with perpendicular magnetic anisotropy were deposited by rf sputtering onto porous alumina films to form antidot arrays with period 105 nm and pore diameters ranging from 18 to 56 nm. The coercivities of the antidot arrays are greater than those of unpatterned films and show only a weak dependence on antidot diameter. Magnetic force microscopy of ac-demagnetized samples shows that the antidot arrays have domain sizes larger than the 105 nm period. The magnetic behavior is discussed in terms of domain wall pinning by the antidots.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fabrication of Cu{sub 2}O/TiO{sub 2} nanotube heterojunction arrays and investigation of its photoelectrochemical behavior

Cu{sub 2}O/TiO{sub 2} nanotube heterojunction arrays have been prepared by photoreduction depositing Cu{sub 2}O nanoparticles on TiO{sub 2} nanotube arrays. The heterojunction arrays show uniformly distributed Cu{sub 2}O nanoparticles, and high crystallinity of anatase and cubic from the TiO{sub 2} and Cu{sub 2}O, respectively. The asymmetry of the current-voltage plot for the material reveals that a heterojunction has been formed between TiO{sub 2} and Cu{sub 2}O. Enhanced charge separation efficiency and improved photoconversion capability are confirmed by electrochemical impedance spectroscopy and photocurrent measurement.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A time-resolved spectroscopic diagnostic based on fast scintillator and optical fiber array for z-pinch plasmas

We report a specially designed type of temporal resolved x-ray spectroscopic diagnostic using a spherically bent quartz crystal for z-pinch plasmas. Registration of time-resolved spectra was accomplished by coupling fast plastic scintillator, an optical fiber array, an optical streak camera, and a charge coupled device as the recording medium of this diagnostic. The diagnostic has been tested in imploding wire array experiments on S-300 pulsed power facility. Time-resolved K-shell lines were successfully obtained for aluminum wire array implosion plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new soft x-ray pulse height analysis array in the HL-2A tokamak

A new soft x-ray pulse height analysis (PHA) array including nine independent subsystems, on basis of a nonconventional software multichannel analysis system and a silicon drift detector (SDD) linear array consisting of nine high performance SDD detectors, has been developed in the HL-2A tokamak. The use of SDD has greatly improved the measurement accuracy and the spatiotemporal resolutions of the soft x-ray PHA system. Since the ratio of peak to background counts obtained from the SDD PHA system is very high, p/b{>=}3000, the soft x-ray spectra measured by the SDD PHA system can approximatively be regarded as electron velocity distribution. The electron velocity distribution can be well derived in the pure ohmic and auxiliary heating discharges. The performance of the new soft x-ray PHA array and the first experimental results with some discussions are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Axial x-ray backlighting of wire-array Z-pinches using X pinches

For the first time, a geometry has been developed to allow for an axial imaging system for wire-array Z-pinch experiments that produce high-resolution x-ray images. The new geometry required a significant redesign of the electrode hardware. Calibrated areal density measurements of the Z-pinch plasma including wire cores, coronal plasma, streaming plasma, and the precursor were obtained. The system used eight-wire molybdenum (Mo) X pinches in series with and directly below the Z-pinch axis to provide micron-scale x-rays sources for point-projection radiography. The images formed on the x-ray sensitive film had a 15 mm diameter field of view at the center height of the array and a magnification of about 7.5:1. Titanium (Ti) filters in front of the film transmitted radiation in the spectral range of 3-5 keV. For calibration, a separate film with the same thickness Ti filter was placed the same distance from the X pinch. This film had an unobstructed path that bypasses the Z-pinch but included step wedges for calibration of the Z-pinch plasma. The step wedges had thicknesses of tungsten (W) ranging from 0.015 to 1.1 {mu}m to obtain areal density measurements of the W plasma from the wire-array. Images had subnanosecond temporal resolution and about 10 {mu}m spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tests of a C{sub 6}D{sub 6} Deuterated Scintillator Array and Measurements of (d, n) Cross Sections

A deuterated liquid-scintillator neutron detector array (C{sub 6}D{sub 6}) has been developed and tested in-beam, which permits useable neutron energy measurements without need of time-of-flight (ToF), while still providing excellent n/gamma and muon discrimination. A similar detector of the same size based on (C{sub 6}H{sub 6}) also was tested for comparison purposes. The exothermic reactions {sup 3}H(d,n){sup 4}He and {sup 2}H(d,n){sup 3}He were used to deduce neutron spectra from the specially designed C{sub 6}D{sub 6} liquid scintillators. Major features of the detector and its response to high-energy neutrons and gammas from a {sup 13}C(d,n){sup 14}N experiment are presented. Preliminary cross sections for the ground and excited states of {sup 14}N have been measured using the detector array. The array should be well-suited for study of many reactions involving neutrons, including exothermic (d, n) reactions with radioactive ion beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗