Search NASA⌕ Search

SEARCH · Search NASA

Results for “building case study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Grey-box Fault Models and Applications for Low Carbon Emission CO2 Refrigeration System

CO2 refrigeration systems have attracted more attentions in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in certain commercial buildings such as supermarkets. However, very limited energy studies have been done for such refrigeration systems under faults. Furthermore, this study investigated five common faults for supermarket transcritical CO2 refrigeration systems with display cases. The following major tasks were implemented for this study. (1) Five fault models (gray-box format) regarding the power consumption and supply air temperature were proposed for low- and high-temperature display cases, respectively. The models cover: ice accumulation on evaporator coil, evaporator fan partial failure, expansion valve failure, display door open, and condenser blockage. (2) These fault models were calibrated with field tests, and the modeling accuracies were in good agreement with measurement datasets. (3) The proposed fault models demonstrated more than 90% of fault detection for Fault Detection and Diagnostics (FDD) purposes for both field measurement and simulated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the effectiveness of smart technologies in the seismic protection of existing buildings Part I: Masonry structures

The first part of a study concerning innovative intervention techniques for dissipate a share of the input seismic energy compatible with the preservation of existing buildings, including historical and monumental constructions, is presented in this paper. The case of a typical scheme of a long-bay box-like masonry building fitted with a dissipative floating roof is analyzed. In the examined building a wide simulation analysis has shown the achievement of a very satisfying performance. Furthermore, the effectiveness of the system can be maximized by means of active or semi-active devices implemented in the floating roof and a significant reduction of the seismic impact on the building can be obtained compared with non-controlled or simply passively controlled structure. The results prove the remarkable increase of the energy dissipation capability of the system, as well as the reduction of structural damage, independently of any specific strengthening intervention.

58 GEOSCIENCES↗

Gray-Box Fault Models and Applications for Low-Carbon Emission CO 2 Refrigeration Systems

CO 2 refrigeration systems have attracted more attentions in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in certain commercial buildings such as supermarkets. However, very limited energy studies have been done for such refrigeration systems under faults. This study investigated five common faults for supermarket transcritical CO 2 refrigeration systems with display cases. The following major tasks were implemented for this study. (1) Five fault models (gray-box format) regarding the power consumption and supply air temperature were proposed for low- and high-temperature display cases, respectively. The models cover: ice accumulation on evaporator coil, evaporator fan partial failure, expansion valve failure, display door open, and condenser blockage. (2) These fault models were calibrated with field tests, and the modeling accuracies were in good agreement with measurement datasets. (3) The proposed fault models demonstrated more than 90% of fault detection for Fault Detection and Diagnostics (FDD) purposes for both field measurement and simulated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Northwest — Advanced Grid Interactive Load Efficiency (AGILE) : A Techno-economic Assessment

The Advanced Grid Interactive Load Efficiency project team, led by Energy Northwest, was awarded funding as part of the fourth round of the Clean Energy Fund program to investigate, co-create, and complete a preliminary design for grid-interactive efficient buildings (GEBs) for a number of schools served by Grays Harbor PUD. The project team has evaluated different combinations of systems at selected school buildings and the potential to respond to grid and customer needs, and develop a preliminary system technical design, including specifying desired GEB technology options, determining communication and electrical interface requirements, assessing control software sensor requirements, and interfacing with building management systems. PNNL led the techno-economic assessment efforts, leveraging its advanced modeling and analytical methods and tools developed for building-to-grid integration. This report documents the economic assessment for different GEB design options, encompassing an in-depth examination of use cases and value propositions, assumptions and inputs, models, methods, case studies, as well as key findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Watching the Watchers with Verified Formal-Assurance Tools (Abbreviated Final Report)

The “Watching the Watchers” project studied the problem of establishing assurance cases for tools that are used to assure other things. Specifically, we were interested in understanding the tools and techniques one could apply to software to build an assurance case to evaluate their applicability, difficulty, level of assurance provided, and scalability. To do so we chose a set of use cases of relevance to LLNL and our various DOE and non-DOE partners and developed demonstrators to perform this evaluation. Our key focal point was around additive manufacturing problems and assurance gaps that we identified in the additive manufacturing workflow from start to completion. We also explored other areas related to AI, data analysis, and concurrent programming. Follow-on research is planned to take our prototypes from this project and adapt and mature them to fit LLNL mission applications.

97 MATHEMATICS AND COMPUTING↗

Building Scale vs. Community Scale Net-Zero Energy Performance

Many government and industry organizations are focusing building energy-efficiency goals around producing individual net-zero buildings (nZEBs), using photovoltaic (PV) technology to provide on-site renewable energy after substantially improving the energy efficiency of the buildings themselves. Seeking net-zero energy (NZE) at the community scale instead introduces the possibility of using a wider range of renewable energy technologies, such as solar-thermal electricity generation, solar-assisted heating/cooling systems, and wind energy, economically. This paper reports results of a study comparing NZE communities to communities consisting of individual nZEBs. Five scenarios are examined: 1) base case – a community of nZEBs with roof mounted PV systems; 2) NZE communities served by wind turbines on leased land; 3) NZE communities served by wind turbines on owned land; 4) communities served by solar-thermal electric generation; and 5) communities served by photovoltaic farms. All buildings are assumed to be highly efficient, e.g., 70% more efficient than current practice. The scenarios are analyzed for two climate locations (Chicago and Phoenix), and the levelized costs of electricity for the scenarios are compared. The results show that even for the climate in the U.S. most favorable to PV (Phoenix), more cost-effective approaches are available to achieving NZE than the conventional building-level approach (rooftop PV with aggressive building efficiency improvements). The paper shows that by expanding the measurement boundary for NZE, a community can take advantage of economies of scale, achieving improved economics while reaching the same overall energy-performance objective.

17 WIND ENERGY↗

Dynamic chemistry of anion recognition

In the past 40 years, anion recognition by synthetic receptors has grown into a rich and vibrant research topic, developing into a distinct branch of Supramolecular Chemistry. Traditional anion receptors comprise organic scaffolds functionalized with complementary binding groups that are assembled by multistep organic synthesis. Recently, a new approach to anion receptors has emerged, in which the host is dynamically self-assembled in the presence of the anionic guest, via reversible bond formation between functional building units. While coordination bonds were initially employed for the self-assembly of the anion hosts, more recent studies demonstrated that reversible covalent bonds can serve the same purpose. In both cases, due to their labile connections, the molecular constituents have the ability to assemble, dissociate, and recombine continuously, thereby creating a dynamic combinatorial library (DCL) of receptors. The anionic guests, through specific molecular recognition, may then amplify (express) the formation of a particular structure among all possible combinations (real or virtual) by shifting the equilibria involved towards the most optimal receptor. This approach is not limited to solution self-assembly, but is equally applicable to crystallization, where the fittest anion-binding crystal may be selected. Finally, the pros and cons of employing dynamic combinatorial chemistry (DCC) vs molecular design for developing anion receptors, and the implications of both approaches to selective anion separations, will be discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage

The energy system infrastructure that delivers power to a building's loads needs to be resilient to withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

User-Preference-Driven Model Predictive Control of Residential Building Loads and Battery Storage for Demand Response: Preprint

This paper presents a user-preference-driven home energy management system (HEMS) for demand response (DR) with residential building loads and battery storage. The HEMS is based on a multi-objective model predictive control algorithm, where the objectives include energy cost, thermal comfort, and carbon emission. A multi-criterion decision making method originating from social science is used to quickly determine user preferences based on a brief survey and derive the weights of different objectives used in the optimization process. Besides the residential appliances used in the traditional DR programs, a home battery system is integrated into the HEMS to improve the flexibility and reliability of the DR resources. Simulation studies have been performed on field data from a residential building stock data set. Appliance models and usage patterns were learned from the data to predict the DR resource availability. Results indicate the HEMS was able to provide a significant amount of load reduction with less than 20% prediction error in both heating and cooling cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Commissioning: A Golden Opportunity for Reducing Energy Costs and Greenhouse-gas Emissions

The aim of commissioning new buildings is to ensure that they deliver, if not exceed, the performance and energy savings promised by their design. When applied to existing buildings, commissioning identifies the almost inevitable 'drift' from where things should be and puts the building back on course. In both contexts, commissioning is a systematic, forensic approach to quality assurance, rather than a technology per se. Although commissioning has earned increased recognition in recent years - even a toehold in Wikipedia - it remains an enigmatic practice whose visibility severely lags its potential. Over the past decade, Lawrence Berkeley National Laboratory has built the world's largest compilation and meta-analysis of commissioning experience in commercial buildings. Since our last report (Mills et al. 2004) the database has grown from 224 to 643 buildings (all located in the United States, and spanning 26 states), from 30 to 100 million square feet of floorspace, and from $17 million to $43 million in commissioning expenditures. The recorded cases of new-construction commissioning took place in buildings representing $2.2 billion in total construction costs (up from 1.5 billion). The work of many more commissioning providers (18 versus 37) is represented in this study, as is more evidence of energy and peak-power savings as well as cost-effectiveness. We now translate these impacts into avoided greenhouse gases and provide new indicators of cost-effectiveness. We also draw attention to the specific challenges and opportunities for high-tech facilities such as labs, cleanrooms, data centers, and healthcare facilities. The results are compelling. We developed an array of benchmarks for characterizing project performance and cost-effectiveness. The median normalized cost to deliver commissioning was $0.30/ft2 for existing buildings and $1.16/ft2 for new construction (or 0.4% of the overall construction cost). The commissioning projects for which data are available revealed over 10,000 energy-related problems, resulting in 16% median whole-building energy savings in existing buildings and 13% in new construction, with payback time of 1.1 years and 4.2 years, respectively. In terms of other cost-benefit indicators, median benefit-cost ratios of 4.5 and 1.1, and cash-on-cash returns of 91% and 23% were attained for existing and new buildings, respectively. High-tech buildings were particularly cost-effective, and saved higher amounts of energy due to their energy-intensiveness. Projects with a comprehensive approach to commissioning attained nearly twice the overall median level of savings and five-times the savings of the least-thorough projects. It is noteworthy that virtually all existing building projects were cost-effective by each metric (0.4 years for the upper quartile and 2.4 years for the lower quartile), as were the majority of new-construction projects (1.5 years and 10.8 years, respectively). We also found high cost-effectiveness for each specific measure for which we have data. Contrary to a common perception, cost-effectiveness is often achieved even in smaller buildings. Thanks to energy savings valued more than the cost of the commissioning process, associated reductions in greenhouse gas emissions come at 'negative' cost. In fact, the median cost of conserved carbon is negative - -$110 per tonne for existing buildings and -$25/tonne for new construction - as compared with market prices for carbon trading and offsets in the +$10 to +$30/tonne range. Further enhancing the value of commissioning, its non-energy benefits surpass those of most other energy-management practices. Significant first-cost savings (e.g., through right-sizing of heating and cooling equipment) routinely offset at least a portion of commissioning costs - fully in some cases. When accounting for these benefits, the net median commissioning project cost was reduced by 49% on average, while in many cases they exceeded the direct value of the energy savings. Commissioning also improves worker comfort, mitigates indoor air quality problems, increases the competence of in-house staff, plus a host of other non-energy benefits. These findings demonstrate that commissioning is arguably the single-most cost-effective strategy for reducing energy, costs, and greenhouse gas emissions in buildings today. Energy savings tend to persist well over at least a 3- to 5-year timeframe, but data over longer time horizons are not available. It is thus important to 'Trust but Verify,' and indeed the field is moving towards a monitoring-based paradigm in which instrumentation is used not only to confirm savings, but to identify opportunities that would otherwise go undetected. On balance, we view the findings here as conservative, in the sense that they underestimate the actual performance of projects when all costs and benefits are considered. They underestimate the technical potential for a scenario in which best practices are applied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage: Preprint

The energy system infrastructure that delivers power to a building's loads needs to be resilient, such that it can withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose a set of novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

A Complex Brownfields Case Study—The Former Bannister Federal Complex, Kansas City, Missouri

Abstract In November 2017, 225 acres (91 ha) of the former Bannister Federal Complex (BFC) in Kansas City, Missouri were transferred from the Federal Government to Bannister Transformation & Development, LLC (BTD), for demolition; environmental corrective measures; and preparation of the site for redevelopment. This presented a once‐in‐a‐lifetime opportunity to reconfigure groundwater remedies and address long‐standing soil contamination issues. The property included more than 40 previously‐identified Solid Waste Management Units, 3.9 million square feet (362,000 m 2 ) of buildings, subsurface utilities dating back to the 1940s, and an active groundwater containment system. Demolition of buildings and installation of an interim groundwater containment system began almost immediately after property transfer. In 2018, BTD substantially modified its project schedule to incorporate the construction of the first new buildings while demolition and remedial activities were ongoing. By October 2020, construction of the first new warehouse commenced while excavation and capping of contaminated soils, installation of a groundwater containment treatment systems, and abandonment of legacy utilities were still underway. Completion of this work, within the originally planned timeframe, was made possible by factors including up‐front multi‐year funding, early and ongoing engagement of regulators, an extended 3‐year due diligence program and planning stage, and establishment of well‐defined environmental targets. Both the soil and groundwater remedies were also designed with the flexibility needed to accommodate unknown conditions, changing schedules, and revisions to the regrading and redevelopment plans. This case study highlights key technical and management factors that led to the successful completion of this complex brownfields remediation project.

Water Resources↗

Prioritization and Implementation Plan for Collaborative Case Study on RPV Steels During Extended Service

Nuclear power currently provides a significant fraction of the United States non-carbon emitting power generation. In future years, nuclear power must continue to generate a significant portion of the nation's electricity to meet the growing electricity demand, clean energy goals, and ensure energy independence. New reactors will be an essential part of the expansion of nuclear power. However, given limits on new builds imposed by economics and industrial capacity, the extended service of the existing fleet will also be required. Ensuring public safety and environmental protection is a prerequisite to all nuclear power plant operating and licensing decisions at all stages of reactor life. This includes the original license period of 40 years, the first license extension to 60 years, and certainly for any consideration of life beyond 60 years. For extended operating periods, it must be shown that adequate aging management programs are present or planned and that appropriate safety margins exist throughout the subsequent license renewal periods. Materials degradation can impact reactor reliability, availability, and potentially, safe operation. Components within a reactor must tolerate the harsh environment of high temperature water, stress, vibration, and/or an intense neutron field. Degradation of materials in this environment can lead to reduced performance, and in some cases, sudden failure. Clearly, understanding materials degradation and accounting for the effects of a reactor environment in operating and regulatory limits is essential. The Light Water Reactor Sustainability (LWRS) Program is designed to support the long-term operation (LTO) of existing domestic nuclear power generation with targeted collaborative research programs into areas beyond current short-term optimization opportunities. Within the LWRS program, two pathways have been initiated to perform research essential to informing relicensing decisions. The Materials Aging and Degradation Pathway is designed to help develop the scientific basis for understanding and predicting long-term environmental degradation behavior of materials in nuclear power plants and to provide data and methods to assess performance of systems, structures, and components essential to safe and sustained operation. The Risk-Informed Safety Margins Characterization Pathway (RISMC) seeks to merge fundamental scientific understanding of critical phenomenological conditions and deterministic predictions of nuclear power plant performance with risk-informed characterization tools. This will provide an integrated characterization of public safety margins in an optimization of nuclear safety, plant performance, and long-term asset management. Clearly, these two pathways have many synergies in goals and outcomes. The data and mechanisms generated in the Materials Pathway may feed into and mold efforts within the RISMC Pathway. In addition, insights from the characterization tools developed in RISMC tasks may inform materials testing needs and experiments. To demonstrate this potentially powerful interaction, a joint case study has been proposed and initiated. This document describes the initial planning for a coordinated study between the Materials and the RISMC Pathways. A brief description of each Pathway is presented along with a more detailed description of the needs and requirements of this collaborative task. A list of criteria for any case-study candidate are then listed, along with the rationale for choosing pressurized thermal shock as the prime candidate an inter-pathway collaboration. A proposed timeline and organization of future interactions on this subject area is also presented.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nationwide Buildings Energy Research enabled through an integrated Data Intensive Scientific Workflow and Advanced Analysis Environment

Modern workflow systems enable scientists to run ensemble simulations at unprecedented scales and levels of complexity, allowing them to study system sizes previously impossible to achieve, due to the inherent resource requirements needed for the modeling work. However as a result of these new capabilities the science teams suddenly also face unprecedented data volumes that they are unable to analyze with their existing tools and methodologies in a timely fashion. In this paper we will describe the ongoing development work to create an integrated data intensive scientific workflow and analysis environment that offers researchers the ability to easily create and execute complex simulation studies and provides them with different scalable methods to analyze the resulting data volumes. The integration of simulation and analysis environments is hereby not only a question of ease of use, but supports fundamental functions in the correlated analysis of simulation input, execution details and derived results for multi-variant, complex studies. To this end the team extended and integrated the existing capabilities of the Velo data management and analysis infrastructure, the MeDICi data intensive workflow system and RHIPE the R for Hadoop version of the well-known statistics package, as well as developing a new visual analytics interface for the result exploitation by multi-domain users. The capabilities of the new environment are demonstrated on a use case that focusses on the Pacific Northwest National Laboratory (PNNL) building energy team, showing how they were able to take their previously local scale simulations to a nationwide level by utilizing data intensive computing techniques not only for their modeling work, but also for the subsequent analysis of their modeling results. As part of the PNNL research initiative PRIMA (Platform for Regional Integrated Modeling and Analysis) the team performed an initial 3 year study of building energy demands for the US Eastern Interconnect domain, which they are now planning to extend to predict the demand for the complete century. The initial study raised their data demands from a few GBs to 400GB for the 3year study and expected tens of TBs for the full century.

99 GENERAL AND MISCELLANEOUS↗

Avoided electricity subsidy payments can finance substantial appliance efficiency incentive programs: Case study of Mexico

Numerous countries use taxpayer funds to subsidize residential electricity for a variety of socioeconomic objectives. These subsidies lower the value of energy efficiency to the consumer while raising it for the government. Further, while it would be especially helpful to have stringent Minimum Energy Performance Standards (MEPS) for appliances and buildings in this environment, they are hard to strengthen without imposing a cost on ratepayers. In this secondbest world, where the presence of subsidies limits the government’s ability to strengthen standards, we find that avoided subsidies are a readily available source of financing for energy efficiency incentive programs. Here, we introduce the LBNL Energy Efficiency Revenue Analysis (LEERA) model to estimate the appliance efficiency improvements that can be achieved in Mexico by the revenue neutral financing of incentive programs from avoided subsidy payments. LEERA uses the detailed techno-economic analysis developed by LBNL for the Super-efficient Equipment and Appliance Deployment (SEAD) Initiative to calculate the incremental costs of appliance efficiency improvements. We analyze Mexico’s tariff structures and the long-run marginal cost of supply to calculate the marginal savings for the government from appliance efficiency. We find that avoided subsidy payments alone can finance incentive programs that cover the full incremental cost of refrigerators that are 27% more efficient and TVs that are 32% more efficient than baseline models. We find less substantial market transformation potential for room ACs primarily because AC energy savings occur at less subsidized tariffs.

25 ENERGY STORAGE↗

New Whole-House Solutions Case Study: A Production Builder's Passive House - Denver, Colorado

Brookfield Home’s first project is in a community called Midtown in Denver, Colorado, in which the builder took on the challenge of increased energy efficiency by creating a Passive House (PH)-certified model home. Brookfield worked with the U.S. Department of Energy’s Building America research team IBACOS to create the home, evaluate advanced building technologies, and use the home as a marketing tool for potential homebuyers. Brookfield also worked with KGA studio architects to create a new floor plan that would be constructed to the PH standard as an upgrade option.

Building America↗