Search NASA⌕ Search

SEARCH · Search NASA

Results for “cavity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Mechanical Properties of Niobium Cavities

The mechanical stability of bulk Nb cavity is an important aspect to be considered in relation to cavity material, geometry and treatments. Mechanical properties of Nb are typically obtained from uniaxial tensile tests of small samples. In this contribution we report the results of measurements of the resonant frequency and local strain along the contour of single-cell cavities made of ingot and fine-grain Nb of different purity subjected to increasing uniform differential pressure, up to 6 atm. Measurements have been done on cavities subjected to different heat treatments. Good agreement between finite element analysis simulations and experimental data in the elastic regime was obtained with a single set of values of Young’s modulus and Poisson’s ratio. The experimental results indicate that the yield strength of medium-purity ingot Nb cavities is higher than that of fine-grain, high-purity Nb.

36 MATERIALS SCIENCE↗

AGR-5/6/7 Fuel Fabrication Report

The U.S. Department of Energy Office of Nuclear Energy (DOE NE) and the Idaho National Laboratory (INL) Advanced Reactor Technologies (ART) Advanced Gas Reactor (AGR) Fuel Development and Qualification program (referred to as AGR Fuel program hereafter) are pursuing qualification of tristructural isotropic (TRISO) coated particle fuel for use in high temperature gas cooled reactors (HTGRs). The AGR Fuel program was established to provide a fuel qualification data set in support of the licensing and operation of an HTGR. BWX Technologies Nuclear Operations Group (BWXT-NOG) was subcontracted to fabricate the fuel for the AGR program. Several investments and innovations were realized in preparation to fabricate fuel for the AGR-5/6/7 irradiation experiments that brought fuel fabrication fully out of the laboratory and into engineering-scale operations. These included: • Increased the kernel fabrication line capacity and uniformity • Upgraded ancillary support equipment and processes for the tristructural isotropic (TRISO) coating furnace • Demonstrated efficient production of the matrix precursor powder by dry jet milling of co mingled components • Demonstrated an engineering-scale method for quick and efficient overcoating TRISO particles with the matrix precursor • Demonstrated an automated, multi cavity compacting system with a volumetric feed system • Demonstrated a combined-cycle thermal treatment furnace These changes increased production rates of some of these processes by an order of magnitude or more while eliminating the use of flammable solvents, multiple grinding and sorting operations, and the weighing out of individual die charges. Three fuel kernel lots were fabricated for production of the fuel for AGR-5/6/7. The initial lot (J52R-16-39316) was certified to fuel specifications but was not used because the kernels had a high fraction of internal fissures that caused an unacceptable fraction of the kernels to fragment when charged to the coating furnace where the TRISO coating would be deposited. Fragmented kernels increased the dispersed uranium in the particles and produced a worrisome fraction of dimpled particles with an elevated probability of in-pile failure. After some efforts to identify the cause of the fissure formation, two additional lots were produced with much lower fissure fractions, J52R-16-69317 and 69318. The latter kernel lot was a backup to the first and was not needed. Multiple kernel batches were composited to form each of the lots so as to simulate a commercial-scale operation where kernel batches would also be composited. Multiple TRISO coating runs were performed and the product characterized so that several could be composited into a TRISO lot. TRISO lot J52R-16-98005 conformed to all fuel specifications except the mean outer pyrocarbon (OPyC) layer thickness was thinner than specified. Furthermore, it was determined that the TRISO lot had a dispersed uranium fraction (DUF) that might result in the compacts not meeting the DUF specification. A review of the role of the OPyC layer and consequences of the DUF by the Technical Coordination Team and INL concluded that the fuel was acceptable for use in the AGR-5/6/7 irradiation experiment. The TRISO particles were overcoated with the matrix precursor that had been produced in a jet-milling operation. The overcoating was performed in equipment originally designed to coat pharmaceuticals. The overcoating process performed well; producing highly spherical and uniform overcoats requiring little upgrading and no recycle or rework. TRISO particles were overcoated with the matrix precursor to achieve nominal volumetric packing fractions (PFs) of TRISO particles of 25% and 40% for the irradiation experiments. The 40% PF compacts occupy the first and fifth test capsule in the test train while the inner three capsules are loaded with 25% PF compacts. The resinated graphite matrix precursor powder was a derivative of the German A3-27 matrix formulation, which differs from previous AGR irradiation campaigns that used an A3-3 formulation. Jet milling of the matrix powder precursor produced a finer mean graphite particle size than the milling operations used for the A3-3 matrix powder precursor. Changes made in the matrix formula and equipment yielded compacts with significantly higher matrix density than was attained in previous AGR irradiation campaigns. The changes in the matrix formulation and the means of milling the powders also complicated resolution of the three fuel compact defect fractions, DUF, exposed kernel fraction (EKF), and the silicon carbide defect fraction (SDF). Characterization data from BWXT-NOG had some anomalous results, so samples of the fuel compacts and overcoated TRISO particles were also analyzed by Oak Ridge National Laboratory (ORNL) to ensure that the defect fractions were accurately characterized.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-J-74: Dosimetric Advantages of Adaptive Radiotherapy for Head and Neck Cancer Are Confirmed with Weekly CBCT Images

Purpose: Our previous study showed that weekly dose monitoring using cone-beam CT (CBCT) images can guide the timing and need for adaptive re-planning during the treatment of head and neck (HN) cancer. Here we aim to confirm the dosimetric improvement of adaptive radiotherapy (ART) using weekly CBCTs. Methods: We randomly selected seven HN patients treated with ART due to noticeable anatomic changes. Twenty weekly images acquired during the second treatment course were included. These CBCTs were aligned with both the initial and re-planning simulation CTs according to the clinical shifts. Daily doses were re-calculated for both the initial and adaptive plans. Contours of the tumor and organs-at-risk (OARs) were manually delineated by a physician on the re-planning CT and then were transferred to the CBCTs for plan evaluation. Contour modifications were made based on the daily anatomic changes observed on CBCTs. All patients were treated with 70Gy to the primary tumor and 56Gy to the elective lymph nodes. Results: Volumetric changes of the tumor (range — 43.9%∼+15.9%) were observed. The average D99 to the primary tumor was (70.1±2.0)Gy (range 62.2∼72.5Gy) for the adaptive plan and (66.0±5.5)Gy (range 50.9∼70.7Gy) for the initial plan(p<<0.01). The average D99 to the elective neck was (56.3±1.3)Gy (range 52.8∼59.2Gy) for the adaptive plan and (52.4±7.0)Gy (range 37.7∼58.6Gy) for the initial plan(p=0.01). The parotid decreased in volume during the treatment course (range 7.3%∼42.2%). The average D-mean to the spared parotid decreased by 15.3% (p=0.002) for the adaptive plan when compared to the original. With ART, 4 out of 7 patients experienced better sparing of the spinal cord (D-max reduced by 2.5%∼10.2%) and the oral cavity (D-mean reduced by 3.5%∼20.1%). Conclusion: Weekly CBCT dosimetry confirms that ART is an effective method to accommodate on-treatment anatomic changes. In select patients, tumor coverage and OAR sparing may be improved with ART. Research is funded by Siemens.

60 APPLIED LIFE SCIENCES↗

A simulation of the Fermilab Main Injector dual power amplifier cavities

The Fermilab Main Injector accelerating cavities have sparking issues when they are run at voltages higher than those required by the PIP-II project. This is a problem Fermilab is working on as planning begins for the next upgrade to the accelerator complex. One of the methods being used to address the issue is the development of a CST Microwave Studio simulation to accurately model the PIP-II dual power amplifier cavities and identify which part(s) of the cavity is causing sparking to develop. The model will also be used to determine if changes to the cavity geometry may allow the cavity to be used at higher voltages before sparking occurs.

Stevenson, Susanna [Fermilab] (ORCID:0009000891261↗

A Simulation of the Fermilab Main Injector Cavities

The Fermilab Main Injector accelerating cavities have sparking issues when they are run at voltages higher than those required by the PIP-II project. This is a problem Fermilab is working on as planning begins for the next upgrade to the accelerator complex. One of the methods being used to address the issue is the development of a CST Microwave Studio simulation to accurately model the PIP-II dual power amplifier cavities and identify which part(s) of the cavity is causing sparking to develop. The model will also be used to determine if changes to the cavity geometry may allow the cavity to be used at higher voltages before sparking occurs

Stevenson, Susanna M. [Fermilab] (ORCID:0009000891↗

Modeling Techniques for Evaluation the Effectiveness of Particle Damping in Turbomachinery

High power turbopumps are frequently used to supply propellants to the combustion chambers of rocket engines. Due to the high pressures and flow-rates required, turbopump components are subjected to harsh environments which include dynamic excitation due to random, sine, and acoustic vibration. Additionally, fluid-induced forces can couple with the dynamics of the structure resulting in flow induced instabilities (flutter). Structural response to these forms of excitation results in reduced fatigue life and increases the likelihood of an operational failure. Particle damping has been used successfully on vibration problems in the past by increasing the damping and therefore reducing the response to acceptable levels. Empirical methods have typically been employed to evaluate the performance of the particles in reducing the structural response. This report explores the use of finite element methods to estimate the effectiveness of particle damping in a typical non-rotating turbopump component. Axisymmetric harmonic models are used to estimate the increase in modal damping produced by the addition of particles in the cavity of an axisymmetric seal. Target modes of vibration are evaluated to quantify how the effective particle damping is altered by geometry changes in the seal design. A new method to predict the performance of particle dampers is developed and shown to provide more reasonable estimates of damping.

Ehrgott, R.↗

Adaptive mesh strategies for the spectral element method

An adaptive spectral method was developed for the efficient solution of time dependent partial differential equations. Adaptive mesh strategies that include resolution refinement and coarsening by three different methods are illustrated on solutions to the 1-D viscous Burger equation and the 2-D Navier-Stokes equations for driven flow in a cavity. Sharp gradients, singularities, and regions of poor resolution are resolved optimally as they develop in time using error estimators which indicate the choice of refinement to be used. The adaptive formulation presents significant increases in efficiency, flexibility, and general capabilities for high order spectral methods.

Mavriplis, Catherine↗

Method and apparatus for removing heat from electronic devices using synthetic jets

An apparatus for removing heat comprises a heat sink having a cavity, and a synthetic jet stack comprising at least one synthetic jet mounted within the cavity. At least one rod and at least one engaging structure to provide a rigid positioning of the at least one synthetic jet with respect to the at least one rod. The synthetic jet comprises at least one orifice through which a fluid is ejected.

42 ENGINEERING↗

Method and apparatus for removing heat from electronic devices using synthetic jets

An apparatus for removing heat comprises a heat sink having a cavity, and a synthetic jet stack comprising at least one synthetic jet mounted within the cavity. At least one rod and at least one engaging structure to provide a rigid positioning of the at least one synthetic jet with respect to the at least one rod. The synthetic jet comprises at least one orifice through which a fluid is ejected.

42 ENGINEERING↗

Benefits assessment of cool skin and ventilated cavity skin: Saving energy and mitigating heat and grid stress

This study assessed the energy-saving and climate-adaptive potential of cool skin and ventilated cavity skin facade technologies in Seoul's high-rise apartment buildings. We created weather scenarios for historical, mid-term future, and long-term future conditions using Coordinated Regional Downscaling EXperiment (CORDEX) method. Building energy simulations were conducted on a South Korean high-rise apartment model to evaluate their performance under different weather conditions. The results indicate that cool skin and ventilated cavity skin technologies can save cooling energy during summers but lead to heating energy penalties in winters. Ventilated cavity skin outperforms cool skin, offering better cooling energy savings and reduced heating penalties. Combining both technologies yields the highest overall energy savings, with 7 %, 9 %, and 10 % cooling energy savings for cool skin, ventilated cavity skin, and the combined package, respectively. However, cool skin increases heating energy consumption by 5 %, while ventilated cavity skin has minimal impact on heating energy. These envelope technologies also reduce peak electricity demand by at least 5 %, 8 %, and 9 %, respectively. They contribute to heat stress reduction, enhance resilience, and decrease extreme heat risks for occupants during power outages by at least 18 % under various weather conditions. Considering the prevalence of aging high-rise apartments in South Korea, adopting these envelope renovation strategies can effectively reduce cooling loads, enhance thermal comfort, and boost resilience under future climates, while avoiding costly reconstruction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stereotactic Irradiation of the Postoperative Resection Cavity for Brain Metastasis: A Frameless Linear Accelerator-Based Case Series and Review of the Technique

Purpose: Whole-brain radiation therapy (WBRT) is the standard of care after resection of a brain metastasis. However, concern regarding possible neurocognitive effects and the lack of survival benefit with this approach has led to the use of stereotactic radiosurgery (SRS) to the resection cavity in place of WBRT. We report our initial experience using an image-guided linear accelerator-based frameless stereotactic system and review the technical issues in applying this technique. Methods and Materials: We retrospectively reviewed the setup accuracy, treatment outcome, and patterns of failure of the first 18 consecutive cases treated at Brigham and Women's Hospital. The target volume was the resection cavity without a margin excluding the surgical track. Results: The median number of brain metastases per patient was 1 (range, 1-3). The median planning target volume was 3.49 mL. The median prescribed dose was 18 Gy (range, 15-18 Gy) with normalization ranging from 68% to 85%. In all cases, 99% of the planning target volume was covered by the prescribed dose. The median conformity index was 1.6 (range, 1.41-1.92). The SRS was delivered with submillimeter accuracy. At a median follow-up of 12.7 months, local control was achieved in 16/18 cavities treated. True local recurrence occurred in 2 patients. No marginal failures occurred. Distant recurrence occurred in 6/17 patients. Median time to any failure was 7.4 months. No Grade 3 or higher toxicity was recorded. A long interval between initial cancer diagnosis and the development of brain metastasis was the only factor that trended toward a significant association with the absence of recurrence (local or distant) (log-rank p = 0.097). Conclusions: Frameless stereotactic irradiation of the resection cavity after surgery for a brain metastasis is a safe and accurate technique that offers durable local control and defers the use of WBRT in select patients. This technique should be tested in larger prospective studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

QM and QM/MM Studies of Uranyl Fluorides in the Gas and Aqueous Phases and in the Hydrophobic Cavities of Tetrabrachion

The structural properties and electronic structures of pentacoordinated uranyl complexes belonging to the [UO₂Fn(H₂O) 5-n ] 2-n series have been studied in the gas and aqueous phases using density functionals with relativistic pseudopotentials and all-electron basis sets in the gas-phase calculations in combination with COSMO in the aqueous phase. In addition, the conformational orientation and structural and electronic properties of [UO₂F₅]³¯ in the hydrophobic cavities of the right-handed coiled-coil (RHCC) protein of tetrabrachion have been determined using the hybrid QM/MM method. Although there is good agreement between the available experimental geometrical parameters and the values obtained in the aqueous phase using pseudopotentials or all-electron basis sets, variation of the uranyl U=O bond with the number of fluoride ligands is only truly captured after the inclusion of five water molecules in the second coordination sphere around the molecules. The docking procedure used in this work shows that there are only two possible orientations of the uranyl group of [UO₂F₅]³¯ embedded in the hydrophobic cavities of the RHCC protein. The two orientations are exclusively along the axes perpendicular to the protein axial channel with no possible orientation of the uranyl group along the axial channel because of both steric effects and interaction with the alkyl chain of the isoleucine residues pointing into the axial channel. In addition, the embedded complex is always positioned nearer to the isoleucine residues at the N-terminal ends of the hydrophobic cavities. Energy analysis, however, reveals that both conformations can only be observed in cavity 2, the largest hydrophobic cavity. The structural and electronic properties of the ligand embedded in this cavity are very similar to those of the gas-phase structure. A comparable study of [Pt(CN)₆]²¯ and the anticancer drug cisplatin, [PtCl₂(NH₃)₂], in cavity 2, revealed the existence of just two orientations for the former, similar to the uranyl complex, and multiple orientations for the latter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Studies as a function of different ALD capping layers on cavity losses for QIS and accelerators

Niobium-based bulk SRF cavities have demonstrated exceptional performance. To further improve niobium cavity performance, we present studies involving a novel surface engineering process designed to prevent the formation of amorphous niobium oxides on the surface. This is achieved by encapsulating the niobium surface using thermal Atomic-Layer-Deposition (ALD). This technique has been shown to enhance the properties of niobium cavities and 2D resonators. This study not only aims to improve SRF performance at high fields but also has the potential to enhance the quality factor in low-field regimes, particularly for quantum applications. For the method to be effective, it is essential to have a clean interface between the encapsulating layer and the bulk niobium. Achieving this requires a uniform coating across the entire cavity surface and efficient removal of the underlying niobium oxides. To optimize the process, a variety of material characterization tools have been utilized to refine parameters such as thin film thickness and annealing conditions. Cavity RF measurements were performed at the vertical test facilities at FNAL to assess the Q vs. Eacc curves for accelerator applications, as well as at the SQMS dilution refrigerators to investigate the full two-level system (TLS) losses at milliKelvin and single-photon levels. Based on the results, we characterized the loss of different oxides in various regimes and applications, comparing them to natural niobium pentoxide.

Grassellino, L. [Fermilab]↗

High power edge-cum-surface emitting terahertz laser arrays phased locked by vacuum guided plasmon waves

Terahertz semiconductor quantum-cascade lasers (QCLs) are widely implemented with metallic cavities that support low-loss plasmonic optical modes at long wavelengths. However, resonant optical modes in such cavities suffer from poor radiative characteristics due to their subwavelength transverse dimensions. Consequently, single-mode terahertz QCLs with metallic cavities and large (>100 mW) output power have only been realized in the surface-emitting configuration that affords a large radiating surface. Here, we demonstrate a method to enhance radiative outcoupling from such plasmonic lasers for high-power emission in the edge-emitting (end-fire or longitudinal) direction. Single-sided plasmon waves propagating in vacuum are resonantly excited in surrounding medium of metallic cavities with the QCL semiconductor medium. The vacuum guided plasmon waves with a large wavefront phase-lock multiple metallic cavities longitudinally, which leads to intense radiation in multiple directions, including that in the longitudinal direction in a narrow single-lobed beam. The multicavity array radiates predominantly in a single spectral mode. A peak-power output of 260 mW and a slope efficiency of 303 mW/A are measured for the end-fire beam from a 3.3 THz QCL operating at 54 K in a Stirling cooler. Finally, single-mode operation and lithographic tuning across a bandwidth of ~150 GHz are demonstrated.

42 ENGINEERING↗

TH-CD-BRA-07: MRI-Linac Dosimetry: Parameters That Change in a Magnetic Field

Purpose: In MRI-linac integrated systems, the presence of the magnetic (B-)field has a large impact of the dose-distribution and the dose-responses of detectors; yet established protocols and previous experience may lead to assumptions about the commissioning process that are no longer valid. This study quantifies parameters that change when performing dosimetry with an MRI-linac including beam quality specifiers and the effective-point-of-measurement (EPOM) of ionization chambers. Methods: We used the Geant4 Monte Carlo code for this work with physics parameters that pass the Fano cavity test to within 0.1% for the simulated conditions with and without a 1.5 T B-field. A point source model with the energy distribution of an MRI-linac beam was used with and without the B-field to calculate the beam quality specifiers %dd(10)× and TPR{sup 20}{sub 10}, the variation of chamber response with orientation and the how the B-field affects the EPOM of ionization chambers by comparing depth-dose curves calculated in water to those generated by a model PTW30013 Farmer chamber. Results: The %dd(10)× changes by over 2% in the presence of the B-field while the TPR{sup 20}{sub 10} is unaffected. Ionization chamber dose-response is known to depend on the orientation w.r.t. the B-field, but two alternative perpendicular orientations (anti-parallel to each other) also differ in dose-response by over 1%. The B-field shifts the EPOM downstream (closer to the chamber center) but it is also shifted laterally by 0.27 times the chamber’s cavity radius. Conclusion: The EPOM is affected by the B-field and it even shifts laterally. The relationship between %dd(10)× and the Spencer-Attix stopping powers is also changed. Care must be taken when using chambers perpendicular to the field as the dose-response changes depending on which perpendicular orientation is used. All of these effects must be considered when performing dosimetry in B-fields and should be accounted for in future dosimetry protocols. This project was partially funded by Elekta Ltd.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-grid domain decomposition approach for solution of Navier-Stokes equations in primitive variable form

The new multigrid (or adaptive) pseudospectral element method was carried out for the solution of incompressible flow in terms of primitive variable formulation. The desired features of the proposed method include the following: (1) the ability to treat complex geometry; (2) high resolution adapted in the interesting areas; (3) requires minimal working space; and (4) effective in a multiprocessing environment. The approach for flow problems, complex geometry or not, is to first divide the computational domain into a number of fine-grid and coarse-grid subdomains with the inter-overlapping area. Next, it is necessary to implement the Schwarz alternating procedure (SAP) to exchange the data among subdomains, where the coarse-grid correction is used to remove the high frequency error that occurs when the data interpolation from the fine-grid subdomain to the coarse-grid subdomain is conducted. The strategy behind the coarse-grid correction is to adopt the operator of the divergence of the velocity field, which intrinsically links the pressure equation, into this process. The solution of each subdomain can be efficiently solved by the direct (or iterative) eigenfunction expansion technique with the least storage requirement, i.e. O(N(exp 3)) in 3-D and O(N(exp 2)) in 2-D. Numerical results of both driven cavity and jet flow will be presented in the paper to account for the versatility of the proposed method.

Ku, Hwar-Ching↗

SEARCHING FOR DARK MATTER IN MESSIER 33

Among various approaches to indirect detection of dark matter (DM), synchrotron emission due to secondary electrons/positrons produced in galactic weakly interacting, massive particles annihilation is raising an increasing interest. In this Letter, we propose a new method to derive bounds in the m {sub {chi}}-({sigma}{sub A} v) plane by using radio continuum observations of Messier 33, paying particular attention to a low emitting radio cavity. The comparison of the expected radio emission due to the galactic DM distribution with the observed one provides bounds which are comparable to those obtained from a similar analysis of the Milky Way. Remarkably, the present results are simply based on archival data and are thus largely improvable by means of specifically tailored observations. The potentiality of the method compared with more standard searches is discussed by considering the optimistic situation of a vanishing flux (within the experimental sensitivity) measured inside the cavity by a high-resolution radio telescope like Atacama Large Millimeter Array. Under the best conditions, our technique is able to produce bounds which are comparable to the ones expected after 5 years of Fermi Large Area Telescope (LAT) data taking for a hadronic annihilation channel. Furthermore, it allows us to test the hypothesis that space telescopes such as Pamela and Fermi LAT are actually observing electrons and positrons due to galactic DM annihilation into leptons.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of Active Seismic and Electrical Methods to Detect and Characterize Subsurface Effects of an Underground Explosion

During the period of underground nuclear testing in the U.S., now ended for over 20 years, the focus of work was to conduct the test and analyze the data as quickly as possible; there was little concern about application of technologies that could be used to detect and characterize the location and depth of the explosion. Thus, there is little experience with applying geophysical methods in places where an underground nuclear explosion (UNE) has taken place. On the other hand, application of geophysical methods to the detection of shallow artifacts and water table depth is commonly applied in the environmental remediation and site characterization realm of commercial geophysical surveys. For nuclear nonproliferation treaty applications which may incorporate both shallow and deep geophysical probing methods (such as on-site inspection (OSI) under the Comprehensive Nuclear Test Ban Treaty [CTBT]), there thus remains a need to better understand detection capabilities of the deeper targets: anomalies related to an explosion cavity or rubble zone that may be located several hundred meters below the ground surface. The purpose of this Coordinated Inspection Technologies (CIT) project was to gain experience in applying active seismic methods and electrical methods at a site in Nevada where an underground nuclear test (UNE) had been conducted in the past to get a better understanding of the capabilities of these methods for detection and characterization of deep subsurface effects of the explosion.

58 GEOSCIENCES↗