Search NASA⌕ Search

SEARCH · Search NASA

Results for “channel coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Learning the right channel in multimodal imaging: automated experiment in piezoresponse force microscopy

We report the development and experimental implementation of the automated experiment workflows for the identification of the best predictive channel for a phenomenon of interest in spectroscopic measurements. The approach is based on the combination of ensembled deep kernel learning for probabilistic predictions and a basic reinforcement learning policy for channel selection. It allows the identification of which of the available observational channels, sampled sequentially, are most predictive of selected behaviors, and hence have the strongest correlations. We implement this approach for multimodal imaging in piezoresponse force microscopy (PFM), with the behaviors of interest manifesting in piezoresponse spectroscopy. We illustrate the best predictive channel for polarization-voltage hysteresis loop and frequency-voltage hysteresis loop areas is amplitude in the model samples. The same workflow and code are applicable for any multimodal imaging and local characterization methods.

36 MATERIALS SCIENCE↗

A new soft x-ray pulse height analysis array in the HL-2A tokamak

A new soft x-ray pulse height analysis (PHA) array including nine independent subsystems, on basis of a nonconventional software multichannel analysis system and a silicon drift detector (SDD) linear array consisting of nine high performance SDD detectors, has been developed in the HL-2A tokamak. The use of SDD has greatly improved the measurement accuracy and the spatiotemporal resolutions of the soft x-ray PHA system. Since the ratio of peak to background counts obtained from the SDD PHA system is very high, p/b{>=}3000, the soft x-ray spectra measured by the SDD PHA system can approximatively be regarded as electron velocity distribution. The electron velocity distribution can be well derived in the pure ohmic and auxiliary heating discharges. The performance of the new soft x-ray PHA array and the first experimental results with some discussions are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent developments of the JET far-infrared interferometer-polarimeter diagnostic

The far-infrared diagnostic provides essential internal measurements of the plasma density and magnetic field topology (q-profile via Faraday rotation angle) in real-time. The diagnostic capabilities have recently been extended in a number of key areas. Fast interferometer data, with 10 {mu}s time resolution, and a new MATLAB code have allowed improved analysis of the evolution of density profiles during fast events such as vertical plasma displacements, edge localized mode, pellet fuelling, and disruptions. Using the polarimeter measurements in real-time, a new calibration procedure has been developed based on a propagation code using the Mueller matrix formalism. A further major upgrade of the system is presently underway: adding a second color laser to the vertical channels and implementing a new phase counter based on analog zero crossing and field-programmable gate array boards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosing on plasma plume from xenon Hall thruster with collisional-radiative model

The collisional-radiative model for xenon is used to calculate the electron density and temperature, and the atom population distribution in the plasma plume from a xenon Hall thruster. In the calculation, 173 levels of atom population are considered; only the processes of electron induced excitation and deexcitation, and spontaneous decay are simulated. The plasma plume is assumed to be optically thin. Consequently, the reasonable parameters of plasma plume along the outside center line of the thruster channel are obtained by making the calculated emission spectrum corresponding to measured ones and based on the atomic data available on site and by codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Information-preserving structures: A general framework for quantum zero-error information

Quantum systems carry information. Quantum theory supports at least two distinct kinds of information (classical and quantum), and a variety of different ways to encode and preserve information in physical systems. A system's ability to carry information is constrained and defined by the noise in its dynamics. This paper introduces an operational framework, using information-preserving structures, to classify all the kinds of information that can be perfectly (i.e., with zero error) preserved by quantum dynamics. We prove that every perfectly preserved code has the same structure as a matrix algebra, and that preserved information can always be corrected. We also classify distinct operational criteria for preservation (e.g., 'noiseless','unitarily correctible', etc.) and introduce two natural criteria for measurement-stabilized and unconditionally preserved codes. Finally, for several of these operational criteria, we present efficient (polynomial in the state-space dimension) algorithms to find all of a channel's information-preserving structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Treatment head disassembly to improve the accuracy of large electron field simulation

Purpose: The purposes of this study are to improve the accuracy of source and geometry parameters used in the simulation of large electron fields from a clinical linear accelerator and to evaluate improvement in the accuracy of the calculated dose distributions. Methods: The monitor chamber and scattering foils of a clinical machine not in clinical service were removed for direct measurement of component geometry. Dose distributions were measured at various stages of reassembly, reducing the number of geometry variables in the simulation. The measured spot position and beam angle were found to vary with the beam energy. A magnetic field from the bending magnet was found between the exit window and the secondary collimators of sufficient strength to deflect electrons 1 cm off the beam axis at 100 cm from the exit window. The exit window was 0.05 cm thicker than manufacturer's specification, with over half of the increased thickness due to water pressure in the channel used to cool the window. Dose distributions were calculated with Monte Carlo simulation of the treatment head and water phantom using EGSnrc, a code benchmarked at radiotherapy energies for electron scatter and bremsstrahlung production, both critical to the simulation. The secondary scattering foil and monitor chamber offset from the collimator rotation axis were allowed to vary with the beam energy in the simulation to accommodate the deflection of the beam by the magnetic field, which was not simulated. Results: The energy varied linearly with bending magnet current to within 1.4% from 6.7 to 19.6 MeV, the bending magnet beginning to saturate at the highest beam energy. The range in secondary foil offset used to account for the magnetic field was 0.09 cm crossplane and 0.15 cm inplane, the range in monitor chamber offset was 0.14 cm crossplane and 0.07 cm inplane. A 1.5%/0.09 cm match or better was obtained to measured depth dose curves. Profiles measured at the depth of maximum dose matched the simulated profiles to 2.6% or better at doses of 80% or more of the dose on the central axis. The profiles along the direction of MLC motion agreed to within 0.16 cm at the edge of the field. There remained a mismatch for the lower beam energies at the edge of the profile that ran parallel to the direction of jaw motion of up to 1.4 cm for the 6 MeV beam, attributed to the MLC support block at the periphery of the field left out of the simulation and to beam deflection by the magnetic field. The possibility of using these results to perform accurate simulation without disassembly is discussed. Phase-space files were made available for benchmarking beam models and other purposes. Conclusions: The match to measured large field dose distributions from clinical electron beams with Monte Carlo simulation was improved with more accurate source details and geometry details closer to manufacturer's specification than previously achieved.

61 RADIATION PROTECTION AND DOSIMETRY↗

A high performance cost-effective digital complex correlator for an X-band polarimetry survey

The detailed knowledge of the Milky Way radio emission is important to characterize galactic foregrounds masking extragalactic and cosmological signals. The update of the global sky models describing radio emissions over a very large spectral band requires high sensitivity experiments capable of observing large sky areas with long integration times. Here, we present the design of a new 10 GHz (X-band) polarimeter digital backend to map the polarization components of the galactic synchrotron radiation field of the Northern Hemisphere sky. The design follows the digital processing trends in radio astronomy and implements a large bandwidth (1 GHz) digital complex cross-correlator to extract the Stokes parameters of the incoming synchrotron radiation field. The hardware constraints cover the implemented VLSI hardware description language code and the preliminary results. The implementation is based on the simultaneous digitized acquisition of the Cartesian components of the two linear receiver polarization channels. The design strategy involves a double data rate acquisition of the ADC interleaved parallel bus, and field programmable gate array device programming at the register transfer mode. The digital core of the back-end is capable of processing 32 Gbps and is built around an Altera field programmable gate array clocked at 250 MHz, 1 GSps analog to digital converters and a clock generator. The control of the field programmable gate array internal signal delays and a convenient use of its phase locked loops provide the timing requirements to achieve the target bandwidths and sensitivity. This solution is convenient for radio astronomy experiments requiring large bandwidth, high functionality, high volume availability and low cost. Of particular interest, this correlator was developed for the Galactic Emission Mapping project and is suitable for large sky area polarization continuum surveys. The solutions may also be adapted to be used at signal processing subsystem levels for large projects like the square kilometer array testbeds.

79 ASTRONOMY AND ASTROPHYSICS↗

Computational fluid dynamics analyses of lateral heat conduction, coolant azimuthal mixing and heat transfer predictions in a BR2 fuel assembly geometry.

To support the analyses related to the conversion of the BR2 core from highly-enriched (HEU) to low-enriched (LEU) fuel, the thermal-hydraulics codes PLTEMP and RELAP-3D are used to evaluate the safety margins during steady-state operation (PLTEMP), as well as after a loss-of-flow, loss-of-pressure, or a loss of coolant event (RELAP). In the 1-D PLTEMP and RELAP simulations, conduction in the azimuthal and axial directions is not accounted. The very good thermal conductivity of the cladding and the fuel meat and significant temperature gradients in the lateral directions (axial and azimuthal directions) could lead to a heat flux distribution that is significantly different than the power distribution. To evaluate the significance of the lateral heat conduction, 3-D computational fluid dynamics (CFD) simulations, using the CFD code STAR-CD, were performed. Safety margin calculations are typically performed for a hot stripe, i.e., an azimuthal region of the fuel plates/coolant channel containing the power peak. In a RELAP model, for example, a channel between two plates could be divided into a number of RELAP channels (stripes) in the azimuthal direction. In a PLTEMP model, the effect of azimuthal power peaking could be taken into account by using engineering factors. However, if the thermal mixing in the azimuthal direction of a coolant channel is significant, a stripping approach could be overly conservative by not taking into account this mixing. STAR-CD simulations were also performed to study the thermal mixing in the coolant. Section II of this document presents the results of the analyses of the lateral heat conduction and azimuthal thermal mixing in a coolant channel. Finally, PLTEMP and RELAP simulations rely on the use of correlations to determine heat transfer coefficients. Previous analyses showed that the Dittus-Boelter correlation gives significantly more conservative (lower) predictions than the correlations of Sieder-Tate and Petukhov. STAR-CD 3-D simulations were performed to compare heat transfer predictions from CFD and the correlations. Section III of this document presents the results of this analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Updates to Relevance Vector Machine: Multiclass Classification, Variable Selection, and Proof-of-Concept Application to Safeguards Fresh Fuel Verification using List-Mode Neutron Collar Data

To expand the capabilities of safeguards authorities to verify the integrity of fresh fuel assemblies, Oak Ridge National Laboratory has retrofit the existing electronics of the JCC-71 uranium neutron coincidence collar, which contains 18 3 He neutron detectors and an external 241 AmLi(α, n) neutron interrogation source arranged to surround a fresh nuclear fuel assembly. The new electronics system allows analysts to record list-mode neutron multiplicity data in addition to the singles and doubles rates that are currently measured. Based on previous proof-of-concept research, analysis of these new data will identify off-normal fuel configurations in an assembly and characterize or localize the specific partial fuel defects. The purpose of this report it to document the analysis algorithm development and then to demonstrate its capability for the safeguards verification of fresh fuel assemblies using list mode neutron collar data. To analyze the complex list-mode data collected with the upgraded uranium neutron collar, multivariate classification algorithms are being developed using a novel classification method, the relevance vector machine. This approach may be applied to multiclass problems to estimate the probability that test data belongs to one of many possible classes of data. In addition, our method identifies the most useful variables/channels for making predictions, which illuminates the basis for the model’s predictions, and this interpretability is largely unique among data analytics methods. Variable selection occurs during model training and parameter tuning and does not need any external hyperparameter tuning routines. Finally, we apply the modified relevance vector machine to a simulated dataset of list-mode neutron collar data generated with the radiation transport code MCNP. The method can correctly identify off-normal fuel configurations, categorize the data according to four fuel defect scenarios, and rank the channels in the data according to prediction utility. For nuclear safeguards applications, it is concluded that this method has the potential to increase the sensitivity and reliability to detect missing fuel rods from a standard 17 x 17 Pressurized Water Reactor (PWR) fresh fuel assembly. Within this analysis, “off-normal” (i.e., missing fuel rods) were correctly classified in 17 simulated test scenarios with one quarter (25%) of the fresh fuel rods missing using a training data set of 58 simulated measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiphysics Simulations of MSRE with NEAMS Thermal Hydraulics Tools

This report documents the benchmarks being developed and simulations performed using tools and codes developed under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, utilizing MSRE experimental data. In FY23, three main work scopes were investigated under the NEAMS MSR work package at ANL. The first scope investigated the Griffin-SAM coupling model for simulating the pump startup transient experiment of MSRE. The analyses start with a simple model (single-channel, single-lattice), gradually adding more details (multi-channel, full-core) into the model. The results show that the reactivity loss curve is very sensitive to the axial boundary conditions and the radial core discretization. The simple model can predict a similar reactivity trend as that of the more sophisticated model, which is likely due to error cancellation. Accurately modeling the axial boundary condition may further improve the reactivity trend but would require significant efforts to generate the mesh of the MSRE inlet and upper plenum. The core channel radial discretization for the Griffin-SAM coupled model also depends on the flow distribution. Given the complex geometry in the inlet plenum, the flow distribution needed to be calculated from CFD analysis, which was performed using the NekRS code. This analysis employed a MSRE CAD model developed by Copenhagen Atomics. The CAD model was disassembled to keep the inlet plenum region only, which was subsequently cleaned and modified so that the mesh generated is under the memory limit. The results are merged to a few radial regions to show that the flow rate is highest in the central region. This would be useful for future improvement of the Griffin-SAM coupling model of the MSRE core. The last task investigated is tritium transport modeling using the standalone SAM code. This task aimed to initiate the effort to demonstrate and validate the tritium transport model implemented in SAM. The preliminary investigation employed an MSRE model consisting of the primary loop. Three tritium transport pathways were examined including the retention in the graphite, the permeation through the HX tube wall, and the removal from the off-gas system. The results compare well with the MSRE data, but improvements are still needed on the initial conditions (i.e., the present state may not have reached equilibrium), the boundary conditions, the off-gas system modeling, and a better numerical strategy to reach the equilibrium state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated source and channel encoded digital communication system design study

The results of several studies Space Shuttle communication system are summarized. These tasks can be divided into the following categories: (1) phase multiplexing for two- and three-channel data transmission, (2) effects of phase noise on the performance of coherent communication links, (3) analysis of command system performance, (4) error correcting code tradeoffs, (5) signal detection and angular search procedure for the shuttle Ku-band communication system, and (6) false lock performance of Costas loop receivers.

Huth, G. K.↗

A communications satellite system concept based on the AMPA experiment

This paper describes a system employing sophisticated satellites with steerable high gain, multibeam phased array antennas, which serve small low-cost user terminals. Adaptive techniques are used to form, point, and shape the beams. Pseudonoise signaling achieves user access/distress without requiring dedicated access/emergency channels. The L-band array has 32 elements, 34-dB gain; the user terminal has 15W transmitter, 3-dB gain antenna. The pseudonoise code and message structures are described. Approximately 100 users can be simultaneously acquired with success-probability exceeding 99%; system capacity can be increased by providing additional beams. System implementation is feasible in the Shuttle era.

Durrani, S. H.↗

A prototype 4800 bps voice terminal for the mobile satellite experiment

The authors report the final stage of a research project for the NASA mobile satellite experiment (MSAT-X). The work has resulted in two alternative coding techniques which have achieved good communications quality at 4.8 kb/s while tolerating vehicle noise, fading, and a fairly high-error-rate, bursty channel. The authors have constructed a circuit board based on three AT&T 32-bit floating-point DSP32 digital signal processors (DSP) and providing both excess processing power and considerable flexibility for handling different variations of the algorithms. A Motorola 68HC11 microcomputer chip serves as the board controller and interface handler. Mounted on a wirewrapped card, the prototype's circuit footprint amounts to only 225 cm2 and consumes about 13 W of power. A description is given of the architecture, signal processing and communication functions, circuitry, and firmware of the prototype. Issues such as synchronization, framing, error control, and modem interface are also addressed.

Chan, Wai-Yip↗

Demonstration of high sensitivity laser ranging system

We report on a high sensitivity semiconductor laser ranging system developed for the Gravity and Magnetic Earth Surveyor (GAMES) for measuring variations in the planet's gravity field. The GAMES laser ranging instrument (LRI) consists of a pair of co-orbiting satellites, one which contains the laser transmitter and receiver and one with a passive retro-reflector mounted in an drag-stabilized housing. The LRI will range up to 200 km in space to the retro-reflector satellite. As the spacecraft pair pass over the spatial variations in the gravity field, they experience along-track accelerations which change their relative velocity. These time displaced velocity changes are sensed by the LRI with a resolution of 20-50 microns/sec. In addition, the pair may at any given time be drifting together or apart at a rate of up to 1 m/sec, introducing a Doppler shift into the ranging signals. An AlGaAs laser transmitter intensity modulated at 2 GHz and 10 MHz is used as fine and medium ranging channels. Range is measured by comparing phase difference between the transmit and received signals at each frequency. A separate laser modulated with a digital code, not reported in this paper, will be used for coarse ranging to unambiguously determine the distance up to 200 km.

Millar, Pamela S.↗

A computer program for processing impedance cardiographic data: Improving accuracy through user-interactive software

This report contains the source code and documentation for a computer program used to process impedance cardiography data. The cardiodynamic measures derived from impedance cardiography are ventricular stroke column, cardiac output, cardiac index and Heather index. The program digitizes data collected from the Minnesota Impedance Cardiograph, Electrocardiography (ECG), and respiratory cycles and then stores these data on hard disk. It computes the cardiodynamic functions using interactive graphics and stores the means and standard deviations of each 15-sec data epoch on floppy disk. This software was designed on a Digital PRO380 microcomputer and used version 2.0 of P/OS, with (minimally) a 4-channel 16-bit analog/digital (A/D) converter. Applications software is written in FORTRAN 77, and uses Digital's Pro-Tool Kit Real Time Interface Library, CORE Graphic Library, and laboratory routines. Source code can be readily modified to accommodate alternative detection, A/D conversion and interactive graphics. The object code utilizing overlays and multitasking has a maximum of 50 Kbytes.

Cowings, Patricia S.↗

Investigation of approximations in thermal-hydraulic modeling of core conversions

Neutronics analyses for core conversions are usually fairly detailed, for example representing all 4 flats and all 4 corners of all 6 tubes of all 20 IRT-3M or -4M fuel assemblies in the core of the VVR-SM reactor in Uzbekistan. The coupled neutronics and thermal-hydraulic analysis for safety analysis transients is usually less detailed, for example modeling only a hot and an average fuel plate and the associated coolant. Several of the approximations have been studied using the RELAP5 and PARET computer codes in order to provide assurance that the lack of full detail is not important to the safety analysis. Two specific cases studied are (1) representation of a core of same- type fuel assemblies by a hot and an average assembly each having multiple channels as well as by merely a hot and average channel and (2) modeling a core containing multiple fuel types as the sum of fractional core models for each fuel type. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On the Performance of Adaptive Data Rate over Deep Space Ka-Bank Link: Case Study Using Kepler Data

Future missions envisioned for both human and robotic exploration demand increasing communication capacity through the use of Ka-band communications. The Ka-band channel, being more sensitive to weather impairments, presents a unique trade-offs between data storage, latency, data volume and reliability. While there are many possible techniques for optimizing Ka-band operations such as adaptive modulation and coding and site-diversity, this study focus exclusively on the use of adaptive data rate (ADR) to achieve significant improvement in the data volume-availability tradeoff over a wide range of link distances for near Earth and Mars exploration. Four years of Kepler Ka-band downlink symbol signal-to-noise (SNR) data reported by the Deep Space Network were utilized to characterize the Ka-band channel statistics at each site and conduct various what-if performance analysis for different link distances. We model a notional closed-loop adaptive data rate system in which an algorithm predicts the channel condition two-way light time (TWLT) into the future using symbol SNR reported in near-real time by the ground receiver and determines the best data rate to use. Fixed and adaptive margins were used to mitigate errors in channel prediction. The performance of this closed-loop adaptive data rate approach is quantified in terms of data volume and availability and compared to the actual mission configuration and a hypothetical, optimized single rate configuration assuming full a priori channel knowledge.

Gao, Jay L.↗