Search NASA⌕ Search

SEARCH · Search NASA

Results for “compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Calibration of Air-Flow Meters for J33 Compressor Investigation

Flow-metering devices used by the NACA and by the manufacturer of the J33 turbojet engine were calibrated together to determine whether an observed discrepancy in weight flow of approximately 4 percent for the two separate investigations might be due to the different devices used to meter air flow. A commercial adjustable orifice and a square-edge flat-plate orifice used by the NACA and a flow nozzle used by the manufacturer were calibrated against surveys across the throat of the nozzle. It was determined that over a range of weight flows from 18 to 45 pounds per second the average weight flows measured by the metering device used for the compressor test would be 0.70 percent lower than those measured by the metering device used in the engine tests and the probable variation about this mean would be +/- 0.39 percent. The very close agreement of the metering devices shows that the greater part of the discrepancy in weight flow is attributable to the effect of inlet pressure.

Kovach, Karl↗

Effect of Angle of Incidence of Second-Stage Vane Assembly on Third-Stage Compressor-Blade Vibration and Engine Performance

Strain-gages were used to measure blade vibrations causing failures in the third stage of a production 11-stage axial-flow compressor. After the serious third-stage vibration was detected, a series of investigations were conducted with second-stage vane assemblies of varying angles of incidence. Curves presented herein show the effect of varying the angle of incidence of second-stage vane assembly on third-stage rotor-blade vibration amplitude and engine performance. A minimum vibration amplitude was obtained without greatly affecting the engine performance with a second-stage vane assembly of 9deg. greater angle of incidence than the assembly normally furnished with the engine.

Meyer, Andre J., Jr.↗

The Influence of the Diameter Ratio on the Characteristics Diagram of the Axial Compressor

With the further development of axial blowers into highly loaded flow machines, the influence of the diameter ratio upon air output and efficiency gains in significance. Clarification of this matter is important for single-stage axial compressors, and is of still greater importance for multistage ones, and particularly for aircraft power plants. Tests with a single-stage axial blower gave a decrease in the attainable maximum pressure coefficient and optimum efficiency as the diameter ratio increased. The decrease must be ascribed chiefly to the guide surface of the hub and housing between the blades increasing with the diameter ratio.

Eckert, B.↗

Measurements on Compressor-Blade Lattices

At the end & 1940 an investigation of a guide-vane lattice for the compressor of a TL unit [NACA comment: Turbojet] was requested. The greatest possible Mach number had to be attained. The investigation was conducted with an annular lattice subjected to axial flow. A direct-current shunt motor with a useful output of 235 horsepower at en engine speed of 1800 qm was available for driving the necessary blower. In designing the blower the speed was set at 10,000 rpm. A gear box fran an armored car was used as gearing in which supplementary fresh oil lubrication was installed. The gear box was used to step up from low to high speeds. The blower that was designed is two stage. The hub-tip ratios are 0.79 to 0.82; the design pressure coefficient for each stage is 0.6 and the design flow coefficient is 0.4. The rotor dosimeter D sub a is 0.39 meters and the resulting peripheral speed is u sub a = 204 meters per second [NACA comment: Value corrected from the German]. The blower was entirely satisfactory. The construction of the test stand is shown in figure 1. The air flows in through an annular Inlet, which is used in the measurement of the quantity of air, and is deflected into an inward-pointing radial slot. A spiral motion is imparted to the air by a guide-vane installation manually adjustable as desired, which enables injection of the air, after it has been deflected from the radial direction to the axial direction, into the lattice being investigated at any desired angle.

Weinig, F.↗

High-Temperature Compressor Material Development

The next generation of subsonic commercial aircraft will require engines with improved efficiency and greater durability at lower costs. To help achieve these goals, manufacturing technologies for the disks, airfoils, and impellers in the compressors of these advanced turbine engines are being developed by a team representing all four U.S. aircraft engine companies--GE Aircraft Engines, Pratt & Whitney, AlliedSignal Inc., and Allison Engine Company. This work is being funded by NASA's Advanced Subsonic Technology (AST) project.

Gayda, John↗

Surge Flow in a Centrifugal Compressor Measured by Digital Particle Image Velocimetry

A planar optical velocity measurement technique known as Particle Image Velocimetry (PIV) is being used to study transient events in compressors. In PIV, a pulsed laser light sheet is used to record the positions of particles entrained in a fluid at two instances in time across a planar region of the flow. Determining the recorded particle displacement between exposures yields an instantaneous velocity vector map across the illuminated plane. Detailed flow mappings obtained using PIV in high-speed rotating turbomachinery components are used to improve the accuracy of computational fluid dynamics (CFD) simulations, which in turn, are used to guide advances in state-of-the-art aircraft engine hardware designs.

Wernet, Mark P.↗

Two-Stage Axial Compressor Rig Designed To Develop and Validate Advanced Aerodynamic Technologies

Future aeropropulsion gas turbine engines must be affordable in addition to being energy efficient and environmentally benign. Progress in aerodynamic design capability is required not only to maximize the specific thrust of next-generation engines without sacrificing fuel consumption, but also to reduce parts count by increasing the aerodynamic loading of the compression system. To meet future compressor requirements, the NASA Glenn Research Center is investigating advanced aerodynamic design concepts that will lead to more compact, higher efficiency, and wider operability configurations than are currently in operation.

Larosiliere, Louis M.↗

A Three-Dimensional Unsteady CFD Model of Compressor Stability

A three-dimensional unsteady CFD code called CSTALL has been developed and used to investigate compressor stability. The code solved the Euler equations through the entire annulus and all blade rows. Blade row turning, losses, and deviation were modeled using body force terms which required input data at stations between blade rows. The input data was calculated using a separate Navier-Stokes turbomachinery analysis code run at one operating point near stall, and was scaled to other operating points using overall characteristic maps. No information about the stalled characteristic was used. CSTALL was run in a 2-D throughflow mode for very fast calculations of operating maps and estimation of stall points. Calculated pressure ratio characteristics for NASA stage 35 agreed well with experimental data, and results with inlet radial distortion showed the expected loss of range. CSTALL was also run in a 3-D mode to investigate inlet circumferential distortion. Calculated operating maps for stage 35 with 120 degree distortion screens showed a loss in range and pressure rise. Unsteady calculations showed rotating stall with two part-span stall cells. The paper describes the body force formulation in detail, examines the computed results, and concludes with observations about the code.

Chima, Rodrick V.↗

Separation Control in a Multistage Compressor Using Impulsive Surface Injection

Control of flow separation using impulsive surface injection is investigated within the multistage environment of a low speed axial-flow compressor. Measured wake profiles behind a set of embedded stator vanes treated with suction-surface injection indicate significant reduction in flow separation at a variety of injection-pulse repetition rates and durations. The corresponding total pressure losses across the vanes reveal a bank of repetition rates at each pulse duration where the separation control remains nearly complete. This persistence allows for demands on the injected-mass delivery system to be economized while still achieving effective flow control. The response of the stator-vane boundary layers to infrequently applied short injection pulses is described in terms of the periodic excitation of turbulent strips whose growth and propagation characteristics dictate the lower bound on the band of optimal pulse repetition rates. The eventual falloff in separation control at higher repetition rates is linked to a competition between the benefits of pulse-induced mixing and the aggravation caused by the periodic introduction of low-momentum fluid. Use of these observations for impulsive actuator design is discussed and their impact on modeling the time-average effect of impulsive surface injection for multistage steady-flow simulation is considered.

Wundrow, David W.↗

Application of Synthetic Jets to Reduce Stator Flow Separation in a Low Speed Axial Compressor

Flow control using synthetic jet injection has been applied in a low speed axial compressor. The synthetic jets were applied from the suction surface of a stator vane via a span-wise row of slots pitched in the streamwise direction. Actuation was provided externally from acoustic drivers coupled to the vane tip via flexible tubing. The acoustic resonance characteristics of the system, and the resultant jet velocities were obtained. The effects on the separated flow field for various jet velocities and frequencies were explored. Total pressure loss reductions across the vane passage were measured. The effect of synthetic jet injection was shown to be comparable to that of pulsatory injection with mass addition for stator vanes which had separated flow. While only a weak dependence of the beneficial effect was noted based on the excitation frequency, a strong dependence on the amplitude was observed at all frequencies.

Braunscheidel, Edward P.↗

Performance of 15-Stage Experimental J71 Axial-Flow Compressor: II - Individual Stage Performance Characteristics

The first four stages were found to cause a major part of the poor low-speed efficiency of this compressor. The low design-speed over-all pressure ratio at surge was caused by the first and the twelfth to fifteenth stages. The multiple over-all performance curves in the intermediate-speed range were at least partly the result of double-branched characteristic curves for the third and seventh stages.

Lucas, James G.↗

Matching Characteristics of J35-A-23 Compressor and Two-stage Turbine

Component data on the J35-A-23 compressor and two-stage turbine were used to determine the problems in matching the two units for operatio n in a turbojet engine. Possible operating regions were determined an d an equilibrium operating line was also determined for the assumed c onditions of zero flight speed and a jet nozzle area approximately 5. 5 percent greater than the wide-open nozzle area.

Dugan, James F., Jr.↗

Vibration Survey of Blades in 19XB Axial-Flow Compressor: Preliminary Engine Investigation - 3

Strain gages were used to measure blade vibrations possibly causing failure in the 10-stage compressor of the 19XB jet-propulsion engine. The seventh and tenth stages were of great concern as a result of failures experienced by the manufacturer. Strain-gage records were obtained from all stages during acceleration, deceleration, and constant speed runs. Curves are presented herein showing the maximum allowable vibratory stress for a given speed, the change of the damping coefficient with the mounting of a strain gage at the base of the blade, the effect of rotor speed, on blade natural frequency, and the effect of the order of first bending-mode vibration on stress. It was found that for all stages the lower the order of vibration the higher the stress but no destructive vibrations were detected.

Meyer, Andre J., Jr.↗

Miniature high speed compressor having embedded permanent magnet motor

A high speed centrifugal compressor for compressing fluids includes a permanent magnet synchronous motor (PMSM) having a hollow shaft, the being supported on its ends by ball bearing supports. A permanent magnet core is embedded inside the shaft. A stator with a winding is located radially outward of the shaft. The PMSM includes a rotor including at least one impeller secured to the shaft or integrated with the shaft as a single piece. The rotor is a high rigidity rotor providing a bending mode speed of at least 100,000 RPM which advantageously permits implementation of relatively low-cost ball bearing supports.

Zhou, Lei↗

Orifice Mass Flow Calculation in NASA's W-8 Single Stage Axial Compressor Facility

Updates to the orifice mass flow calculation for the W-8 Single Stage Axial Compressor Facility at NASA Glenn Research Center are provided to include the effect of humidity and incorporate ISO 5167. A methodology for including the effect of humidity into the inlet orifice mass flow calculation is provided. Orifice mass flow calculations provided by ASME PTC-19.5-2004, ASME MFC-3M-2004, ASME Fluid Meters, and ISO 5167 are compared for W-8's atmospheric inlet orifice plate. Differences in expansion factor and discharge coefficient given by these standards give a variation of about +/- 75% mass flow except for a few cases. A comparison of the calculations with an inlet static pressure mass flow correlation and a fan exit mass flow integration using test data from a 2017 turbofan rotor test in W-8 show good agreement between the inlet static pressure mass flow correlation, ISO 5167, and ASME Fluid Meters. While W-8's atmospheric inlet orifice plate violates the pipe diameter limit defined by each of the standards, the ISO 5167 is chosen to be the primary orifice mass flow calculation to use in the W-8 facility.

Aerodynamics↗

Upgrades to the Single Stage Axial Compressor and Fan Facility For Low Pressure Ratio and Boundary Layer Ingesting Fan Research

Next generation aircraft engine efficiency goals will be met through high bypass ratio engines. To achieve these goals, a combination of small core and low pressure ratio fan technologies will be necessary. Additionally, advanced propulsion air-frame integration concepts, such as boundary layer propulsion, and distributed electrically driven fans with short inlets or wing integration strategies, are beginning to be investigated for their potential fuel burn savings. In order to realize the potential fuel savings from these technologies, it is necessary to have testing capabilities for the components. The NASA Glenn Research Center (GRC) Single StageAxial Fan and Compressor Facility (also called the GRC W-8Facility) has recently undergone several significant upgrades in order to effectively test low pressure ratio fans and various inlet distortions. This paper will outline various challenges to testing low pressure ratio fans and the methods implemented to ensure that the W-8 facility is capable of performing these tests and acquiring high quality data. The upgrades include significant pip-ing upgrades to reduce pressure loss and turbulence, capability for inlet total pressure and swirl distortion, increased test section length including a longer shaft, a two component balance, an up-graded rotating data system, and a new temperature characterization to reduce uncertainties in thermocouple measurements

W-8 Facility↗

Upgrades to the Single Stage Axial Compressor and Fan Facility For Low Pressure Ratio and Boundary Layer Ingesting Fan Research

Next generation aircraft engine efficiency goals will be met through high bypass ratio engines. To achieve these goals, a combination of small core and low pressure ratio fan technologies will be necessary. Additionally, advanced propulsion airframe integration concepts, such as boundary layer propulsion, and distributed electrically driven fans with short inlets or wing integration strategies, are beginning to be investigated for their potential fuel burn savings. In order to realize the potential fuel savings from these technologies, it is necessary to have testing capabilities for the components. The NASA Glenn Research Center (GRC) Single Stage Axial Fan and Compressor Facility (also called the GRC W-8 Facility) has recently undergone several significant upgrades in order to effectively test low pressure ratio fans and various inlet distortions. This paper will outline various challenges to testing low pressure ratio fans and the methods implemented to ensure that the W-8 facility is capable of performing these tests and acquiring high quality data. The upgrades include significant piping upgrades to reduce pressure loss and turbulence, capability for inlet total pressure and swirl distortion, increased test section length including a longer shaft, a two component balance, an upgraded rotating data system, and a new temperature characterization to reduce uncertainties in thermocouple measurements.

W-8 facitlity↗

Modeling the Integrated Thermal Amine Scrubber and Air Cooled-Temperature Swing Adsorbent Compressor

As part of a larger CO2 removal architecture study, a model was developed in Aspen Custom Modeler of the Thermal Amine Scrubber (TAS), an ISS flight experiment intended to scrub CO2 from the cabin air. In order to minimize mass losses, it was determined the TAS should work in conjunction with the Air Cooled-Temperature Swing Adsorption Compressor (AC-TSAC) to reduce the CO2 for O2 production. First the TAS removes CO2 from the cabin atmosphere, then the AC-TSAC compresses the CO2 and feeds it in a steady steam to a Sabatier or Bosch process. This document details an effort to add a model of the AC-TSAC to the existing TAS model to determine if the two hardware systems will have deleterious effects on each other’s performance. It was found the AC-TSAC provided sufficient vacuum for the TAS’s desorption to occur, but not the same level of vacuum as space vacuum. This lower quality vacuum led to a reduction in the total cyclical uptake capacity of the TAS and thus a lower CO2 removal under the same conditions. The TAS did not remove enough CO2 to fill the AC-TSAC bed to capacity during the production phase which caused the AC-TSAC to run out of CO2 during production. This renders the addition of the AC-TSAC pointless. It is believed these effects can be overcome with a redesign of one or both systems.

TAS↗