Search NASA⌕ Search

SEARCH · Search NASA

Results for “computer applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Applications of NMR and computational methodologies to study protein dynamics

The overwhelming evidence now illustrates the defining role of atomic-scale protein flexibility in biological events such as allostery, cell signaling, and enzyme catalysis. Over the years, spin relaxation nuclear magnetic resonance (NMR) has provided significant insights on the structural motions occurring on multiple time frames over the course of a protein life span. The present review article aims to illustrate to the broader community how this technique continues to shape many areas of protein science and engineering, in addition to being an indispensable tool for studying atomic-scale motions and functional characterization. Continuing developments in underlying NMR technology alongside software and hardware developments for complementary computational approaches now enable methodologies to routinely provide spatial directionality and structural representations traditionally harder to achieve solely using NMR spectroscopy. In addition to its well-established role in structural elucidation, we present recent examples that illustrate the combined power of selective isotope labeling, relaxation dispersion experiments, chemical shift analyses, and computational approaches for the characterization of conformational sub-states in proteins and enzymes.

59 BASIC BIOLOGICAL SCIENCES↗

Image Distortions on a Plastic Interstitial Computed Tomography/Magnetic Resonance Brachytherapy Applicator at 3 Tesla Magnetic Resonance Imaging and Their Dosimetric Impact

Purpose: To quantify magnetic resonance imaging (MRI) distortions on a plastic intracavitary/interstitial applicator with plastic needles at a field strength of 3 T and to determine the dosimetric impact, using patient data. Methods and Materials: For 11 cervical cancer patients, our clinical MRI protocol was extended with 3 scans. From the first scan, a multi-echo acquisition, a map of the magnetic field (B{sub 0}) was calculated and used to quantify the field inhomogeneity. The expected displacements of the applicator were quantified for the clinical sequence using the measured field inhomogeneity and the clinical sequence's bandwidth. The second and third scan were our routine clinical sequence (duration: <5 minutes each), acquired consecutively using opposing readout directions. The displacement of the applicator between these scans is approximately twice the displacement due to B{sub 0} inhomogeneity. The impact of the displacement on the dose was determined by reconstructing the applicator on both scans. The applicator was then shifted and rotated the same distance as the observed displacement to create a worst-case scenario (ie, twice the actual displacement due to B{sub 0} inhomogeneity). Next, the dose to 98%/90% (D{sub 98}/D{sub 90}) of the clinical target volume at high risk, as well as the dose to the most irradiated 2 cm{sup 3} for bladder and rectum, were calculated for the original plan as well as the shifted plan. Results: For a volume of interest containing the intrauterine device and the ovoids the 95th percentile of the absolute displacement ranged between 0.2 and 0.75 mm, over all patients. For all patients, the difference in D{sub 98}/D{sub 90} in the opposing readout scans with the original plan was at most 4.7%/4.3%. For the dose to the most irradiated 2 cm{sup 3} of bladder/rectum, the difference was at most 6.0%/6.3%. Conclusions: The dosimetric impact of distortions on this plastic applicator with plastic needles is limited. Applicator reconstruction for brachytherapy planning purposes is feasible at 3 T MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-175: Evaluation of Metal Artifact Reduction Algorithms in Computed Tomography and Their Application to Radiation Therapy Treatment Planning

Purpose: High-Z (metal) implants in CT scans cause significant streak-like artifacts in the reconstructed dataset. This results in both inaccurate CT Hounsfield units for the tissue as well as obscuration of the target and organs at risk (OARs) for radiation therapy planning. Herein we analyze two metal artifact reduction algorithms: GE’s Smart MAR and a Metal Deletion Technique (MDT) for geometric and Hounsfield Unit (HU) accuracy. Methods: A CT-to-electron density phantom, with multiple inserts of various densities and a custom Cerrobend insert (Zeff=76.8), is utilized in this continuing study. The phantom is scanned without metal (baseline) and again with the metal insert. Using one set of projection data, reconstructed CT volumes are created with filtered-back-projection (FBP) and the MAR and the MDT algorithms. Regions-of-Interest (ROIs) are evaluated for each insert for HU accuracy; the metal insert’s Full-Width-Half-Maximum (FWHM) is used to evaluate the geometric accuracy. Streak severity is quantified with an HU error metric over the phantom volume. Results: The original FBP reconstruction has a Root-Mean-Square-Error (RMSE) of 57.55 HU (STD=29.19, range=−145.8 to +79.2) compared to baseline. The MAR reconstruction has a RMSE of 20.98 HU (STD=13.92, range=−18.3 to +61.7). The MDT reconstruction has a RMSE of 10.05 HU (STD=10.5, range=−14.8 to +18.6). FWHM for baseline=162.05; FBP=161.84 (−0.13%); MAR=162.36 (+0.19%); MDT=162.99 (+0.58%). Streak severity metric for FBP=19.73 (22.659% bad pixels); MAR=8.743 (9.538% bad); MDT=4.899 (5.303% bad). Conclusion: Image quality, in terms of HU accuracy, in the presence of high-Z metal objects in CT scans is improved by metal artifact reduction reconstruction algorithms. The MDT algorithm had the highest HU value accuracy (RMSE=10.05 HU) and best streak severity metric, but scored the worst in terms of geometric accuracy. Qualitatively, the MAR and MDT algorithms increased detectability of inserts, although there is a loss of in-plane resolution near the metallic insert.

60 APPLIED LIFE SCIENCES↗

Modeling of Liquid Hydrogen Tank Cooled with Para-Orthohydrogen Conversion

With the accelerating development of liquid-hydrogen storage facilities, the problem of boil-off hydrogen losses becomes very important. A promising method to reduce these losses is to utilize the endothermic para-orthohydrogen conversion of vented hydrogen, which can effectively decrease heat loads on a hydrogen tank. To model such a process, a hybrid computational model has been developed, based on the application of computational fluid dynamics for an ullage space, where knowledge of thermal stratification is important, and reduced-order models for other system elements. The simulation results for a spheroidal tank in selected conditions indicated a 10–25% reduction of boil-off losses due to cooling produced by vented hydrogen undergoing para-ortho-conversion.

08 HYDROGEN↗

Automatic computer subprogram selection from application program libraries

The program ALTLIB (ALTernate LIBrary) which allows a user access to an alternate subprogram library with a minimum effort is discussed. The ALTLIB program selects subprograms from an alternate library file and merges them with the user's program load file. Only subprograms that are called for (directly or indirectly) by the user's programs and that are available on the alternate library file will be selected. ALTLIB eliminates the need for elaborate control-card manipulations to add subprograms from a subprogram file. ALTLIB returns to the user his binary file and the selected subprograms in correct order for a call to the loader. The user supplies the alternate library file. Subprogram requests which are not satisfied from the alternate library file will be satisfied at load time from the system library.

Drozdowski, J. M.↗