Search NASA⌕ Search

SEARCH · Search NASA

Results for “condition based monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Visual display and alarm system for wind tunnel static and dynamic loads

A wind tunnel balance monitor and alarm system developed at NASA Ames Research Center will produce several beneficial results. The costs of wind tunnel delays because of inadvertent balance damage and the costs of balance repair or replacement can be greatly reduced or eliminated with better real-time information on the balance static and dynamic loading. The wind tunnel itself will have enhanced utility with the elimination of overly cautious limits on test conditions. The microprocessor-based system features automatic scaling and 16 multicolored LED bargraphs to indicate both static and dynamic components of the signals from eight individual channels. Five individually programmable alarm levels are available with relay closures for internal or external visual and audible warning devices and other functions such as automatic activation of external recording devices, model positioning mechanism, or tunnel shutdown.

Hanly, Richard D.↗

Crop-CASMA - A Web GIS Tool for Cropland Soil Moisture Monitoring and Assessment Based on SMAP Data

Timely, frequent, and complete cropland soil moisture information acquired throughout the growing season is critical for agricultural policy, production, food security, and food prices. The NASA Soil Moisture Active and Passive (SMAP) mission provides a reliable data source for cropland soil moisture assessment. This paper presents Crop-CASMA- a web GIS application tool for cropland soil moisture monitoring and assessment based on SMAP data. This interactive Web service-based GIS application tool enables CONUS SMAP derived soil moisture data visualization, dissemination, and analytics. In this paper, we describe the Crop-CASMA application system architecture, the application implementation, and the data it serves. In addition, we also present a few snapshots of the Crop-CASMA data for cropland soil moisture monitoring. The release of Crop-CASMA greatly enhances the user experience and facilitates using soil moisture data products for crop condition monitoring and decision support.

Zhengwei Yang↗

Crop-CASMA - A Web GIS Tool for Cropland soil moisture Monitoring and Assessment Based on SMAP Data

Timely, frequent, and complete cropland soil moisture information acquired throughout the growing season is critical for agricultural policy, production, food security, and food prices. The NASA Soil Moisture Active and Passive (SMAP) mission provides a reliable data source for cropland soil moisture assessment. This paper presents Crop-CASMA - a web GIS application tool for cropland soil moisture monitoring and assessment based on SMAP data. This interactive Web service-based GIS application tool enables CONUS SMAP derived soil moisture data visualization, dissemination, and analytics. In this paper, we describe the Crop-CASMA application system architecture, the application implementation, and the data it serves. In addition, we also present a few snapshots of the Crop-CASMA data for cropland soil moisture monitoring. The release of Crop-CASMA greatly enhances the user experience and facilitates using soil moisture data products for crop condition monitoring and decision support.

Reichle, Rolf H.↗

Augmented Kalman filter with a reduced mechanical model to estimate tower loads on a land-based wind turbine: a step towards digital-twin simulations

This article presents an application of the Kalman filtering technique to estimate loads on a wind turbine. The approach combines a mechanical model and a set of measurements to estimate signals that are not available in the measurements, such as wind speed, thrust, tower position, and tower loads. The model is severalfold faster than real time and is intended to be run online, for instance, to evaluate real-time fatigue life consumption of a field turbine using a digital twin, perform condition monitoring, or assess loads for dedicated control strategies. The mechanical model is built using a Rayleigh–Ritz approach and a set of joint coordinates. We present a general method and illustrate it using a 2-degrees-of-freedom (DOF) model of a wind turbine and using rotor speed, generator torque, pitch, and tower-top acceleration as measurement signals. The different components of the model are tested individually. The overall method is evaluated by computing the errors in estimated tower-bottom-equivalent moment from a set of simulations. From this preliminary study, it appears that the tower-bottom-equivalent moment is obtained with about 10 % accuracy. The limitation of the model and the required steps forward are discussed.

17 WIND ENERGY↗

Shear-Wave Radiation Patterns from Explosive and Earthquake Sources in Scattering, Heterogeneous Media

Distinguishing whether a seismic event is an earthquake or an explosion is a core problem in explosion monitoring. For simplistic models, earthquakes produce a predictable S-wavefield based on their radiation pattern, while an explosion produces no S-wavefield. However, observations from nuclear tests show that explosions can produce significant S-wave energy on both horizontal components. We perform numerical experiments using SPECFEM to constrain when an S-wavefield generated from an explosion might differ from one produced by an earthquake. We generate the S-wavefield for our explosions by placing the source location within a small region consisting of large velocity heterogeneities. For the 2D cases investigated here, a crucial condition is that the size of the region of heterogeneities must be much smaller (approximately 1/12th) than the minimum wavelength of the wavefield for our simulation setups. We investigate both isotropic heterogeneities and anisotropic heterogeneities. Initial results demonstrate that the heterogeneous region lowers the P/S amplitude ratios of an explosion. The presence of strong anisotropic heterogeneities near the source can also produce an S-wavefield with similar amplitudes to the P-wavefield. Lastly, we show that S-wave polarization angles vary as a function of azimuth and distance for explosive sources in the presence of small-scale heterogeneities.

58 GEOSCIENCES↗

Characteristics of an Introduced Walleye Population with Implications for Suppression

Abstract The management of introduced fishes, including Walleye Sander vitreus, whether for control or enhancement, requires understanding of population dynamics at the invasion front. Walleye recently established in the Pend Oreille basin, Idaho, threaten the existing salmonid-based fish community and associated recreational fishery. Therefore, the objectives of this study were to describe population growth and associated life history characteristics. Walleye were sampled in October of 2011, 2014, and 2017 using a standardized gill netting survey protocol to describe trends in relative abundance and evaluate population dynamics. Relative abundance increased exponentially from 1.4 to 4.3 fish/net over the 6-year monitoring period. This population was characterized by fast somatic growth, robust body condition, and early age at maturity at or near the biological maxima for Walleye. Among the survey years, mean length at age 2 varied for female (359–441 mm) and male (358–426 mm) Walleye and relative weight varied from 91 to 98. The sampled Walleye matured at 1 to 4 years of age, and recruitment became more consistent as abundance increased. These density-dependent metrics suggest that the Walleye population is still at low density relative to carrying capacity. The information that was gained from this study was used to better understand potential risks and guide management decisions related to experimental population suppression that is now underway. Suppression under these conditions must overcome the recruitment capabilities of the population. We conclude that natural mortality is likely regulated by density-dependent processes. Therefore, at current (low) density, fishing mortality may be entirely additive and compensation is unlikely to further complicate management.

Ryan, Robert G.↗

Application of Atmospheric Gases and Particulate Matter to the Assessment of Urban Heat Island

Background: Urban heat island (UHI), where built areas are warmer compared to non-urban regions, increases human related diseases and mortality. A key challenge in UHI analysis is the designation of sites as urban or suburban/rural; however, the growing complexity of green spaces in urban areas and the predominance of the transportation sector in nonurban areas creates a dilemma for distinct delineation. Objectives: This study aims to utilize the variability of atmospheric components such as particulate matter (PM), inorganic gases, and volatile organic compounds (VOCs) as direct tracers of the degree of urbanization for ground-based measurements to fully comprehend UHI in convoluted regions with indistinct delineation of urban and nonurban environments. Methods: Atmospheric gases and aerosols were used as direct tracers of urbanization for UHI analysis. Inorganic gases and particulate matter were monitored in two sites in a southeastern US city with varying degrees of urbanization. VOCs were analyzed using a proton transfer reaction time-of-flight mass spectrometer. Results: The more-urbanized site exhibited warmer night conditions and elevated total oxidant levels, leading to the formation of nanometer-sized particles. Machine learning analysis revealed similar atmospheric pollutant profiles for both sites, suggesting comparable sources and variability. Biogenic VOCs were enhanced at the less-urbanized site; however, levels of anthropogenic aromatic VOCs were comparable for both sites. A comprehensive mass spectra analysis revealed distinct molecular backbones per site that further affirmed the applicability of VOCs as indicators of urbanization. Conclusion: This study concludes that VOCs provide more direct and accurate information than typical inorganic gases and PM parameters for characterizing the degree of urbanization. Further exploration of VOCs can enhance our understanding of UHI dynamics and its interaction with vegetation in urban green spaces.

Air quality sensor↗

Performance Analysis of Li-ion Battery Under Various Thermal and Load Conditions

In the recent years, with the rapid advancements made in the technologies of electric and hybrid electric vehicles, selecting suitable batteries has become a major factor. Among the batteries currently used for these types of vehicles, the lithium-ion battery leads the race. Apart from that, the energy gained from regenerative braking in locomotives and vehicles can be stored in batteries for later use for propulsion thus improving the fuel consumption and efficiency. But batteries can be subjected to a wide range of temperatures depending upon the operating conditions. Thus, a thorough knowledge of the battery performance over a wide range of temperatures and different load conditions is necessary for their successful employment in future technologies. In this context, this study aims to experimentally analyze the performance of Li-ion batteries by monitoring the charge–discharge rates, efficiencies, and energy storage capabilities under different environmental and load conditions. Sensors and thermal imaging camera were used to track the environment and battery temperatures, whereas the charge–discharge characteristics were analyzed using CADEX analyzer. The results show that the battery performance is inversely proportional to charge–discharge rates. This is because, at higher charge–discharge rates, the polarization losses increase thus increasing internal heat generation and battery temperature. Also, based on the efficiency and energy storage ability, the optimum performing conditions of the Li-ion battery are 30–40 °C (temperature) and 0.5 C (C-rate).

25 ENERGY STORAGE↗

Evaluating Tools and Technologies for Monitoring Baleen Whales During Offshore Wind Foundation Installation

Impacts to baleen whales are of particular concern in the context of offshore wind development because of their conservation status, the overlap of their habitat with current and planned offshore wind energy facilities, and their expected sensitivity to low-frequency sounds, such as those produced during pile driving. Therefore, this report focuses on monitoring technologies capable of detecting this species group. The scope of this report is to assess the current state of technologies and methods for monitoring baleen whales in low- and no-light conditions in conjunction with offshore wind foundation installation. This work considers the performance of various sensing technologies that can be used to observe the presence of baleen whales near offshore construction activities. The scope of work includes: 1. Technology Performance Metrics – Identify metrics that can be used to assess technology performance. 2. Technology Evaluation – Synthesize the past performance of technologies with respect to the performance metrics based on available literature. 3. Technology Characterization Framework – Describe a potential framework to characterize technology performance with a standardized approach. 4. Technology Research and Development Needs – Identify future needs and opportunities for research, development, and deployment to improve technologies.

17 WIND ENERGY↗

Weather Information System

WxLink is an aviation weather system based on advanced airborne sensors, precise positioning available from the satellite-based Global Positioning System, cockpit graphics and a low-cost datalink. It is a two-way system that uplinks weather information to the aircraft and downlinks automatic pilot reports of weather conditions aloft. Manufactured by ARNAV Systems, Inc., the original technology came from Langley Research Center's cockpit weather information system, CWIN (Cockpit Weather INformation). The system creates radar maps of storms, lightning and reports of surface observations, offering improved safety, better weather monitoring and substantial fuel savings.

Source record↗

AIN-Based Packaging for SiC High-Temperature Electronics

Packaging made primarily of aluminum nitride has been developed to enclose silicon carbide-based integrated circuits (ICs), including circuits containing SiC-based power diodes, that are capable of operation under conditions more severe than can be withstood by silicon-based integrated circuits. A major objective of this development was to enable packaged SiC electronic circuits to operate continuously at temperatures up to 500 C. AlN-packaged SiC electronic circuits have commercial potential for incorporation into high-power electronic equipment and into sensors that must withstand high temperatures and/or high pressures in diverse applications that include exploration in outer space, well logging, and monitoring of nuclear power systems. This packaging embodies concepts drawn from flip-chip packaging of silicon-based integrated circuits. One or more SiC-based circuit chips are mounted on an aluminum nitride package substrate or sandwiched between two such substrates. Intimate electrical connections between metal conductors on the chip(s) and the metal conductors on external circuits are made by direct bonding to interconnections on the package substrate(s) and/or by use of holes through the package substrate(s). This approach eliminates the need for wire bonds, which have been the most vulnerable links in conventional electronic circuitry in hostile environments. Moreover, the elimination of wire bonds makes it possible to pack chips more densely than was previously possible.

Savrun, Ender↗

The Validity Chlorophyll-a Estimation by Sun Induced Fluorescence in Estuarine Waters: An Analysis of Long-term (2003-2011) Water Quality Data from Tampa Bay, Florida (USA)

Satellite observation of phytoplankton concentration or chlorophyll-a is an important characteristic, critically integral to monitoring coastal water quality. However, the optical properties of estuarine and coastal waters are highly variable and complex and pose a great challenge for accurate analysis. Constituents such as suspended solids and dissolved organic matter and the overlapping and uncorrelated absorptions in the blue region of the spectrum renders the blue-green ratio algorithms for estimating chlorophyll-a inaccurate. Measurement of sun-induced chlorophyll fluorescence, on the other hand, which utilizes the near infrared portion of the electromagnetic spectrum, may provide a better estimate of phytoplankton concentrations. While modelling and laboratory studies have illustrated both the utility and limitations of satellite baseline algorithms based on the sun induced chlorophyll fluorescence signal, few have examined the empirical validity of these algorithms using a comprehensive long term in situ data set. In an unprecedented analysis of a long term (2003-2011) in situ monitoring data from Tampa Bay, Florida (USA), we assess the validity of the FLH product from the Moderate Resolution Imaging Spectrometer (MODIS) against chlorophyll ]a and a suite of water quality parameters taken in a variety of conditions throughout a large optically complex estuarine system. A systematic analysis of sampling sites throughout the bay is undertaken to understand how the relationship between FLH and in situ chlorophyll-a responds to varying conditions within the estuary including water depth, distance from shore and structures and eight water quality parameters. From the 39 station for which data was derived, 22 stations showed significant correlations when the FLH product was matched with in situ chlorophyll-alpha data. The correlations (r2) for individual stations within Tampa Bay ranged between 0.67 (n=28, pless than 0.01) and-0.457 (n=12, p=.016), indicating that for some areas within the Bay, FLH can be a good predictor of chlorophyll-alpha concentration and hence a useful tool for the analysis of water quality. Overall, the results show a 106% increase in the validity of chlorophyll -a concentration estimates using FLH over the standard the blue-green OC3M algorithm. This analysis also illustrates that the correlations between FLH and in situ chlorophyll -a measurements increases with increasing water depth and distance of the monitoring sites from both the shore and structures. However, due to confounding factors related to the complexity of the estuarine system, a linear improvement in the FLH to chlorophyll ]a relationship was not clearly noted with increasing depth and distance from shore alone. Correlations of FLH with turbidity, nutrients (total nitrogen and total phosphorous) biological oxygen demand, salinity, sea surface temperature correlated positively with FLH concentrations, while dissolved oxygen and pH showed negative correlations. Principle component analyses are employed to further describe the relationships between the multivariate water quality parameters and the FLH product. The majority of sites with higher and very significant correlations (pless than 0.01) also showed high correlation values for nutrients, turbidity and biological oxygen demand. These sites were on average in greater than seven meters of water and over five kilometers from shore. A thorough understanding of the relationship between the MODIS FLH product and in situ water quality parameters will enhance our understanding of the accuracy MODIS fs global FLH algorithm and assist in optimizing its calibration for use in monitoring the quality of estuarine and coastal waters worldwide.

Moreno-Madrinan, Max Jacobo↗

"Designing, simulating, and performing the 100-AV field test for the CIRCLES consortium: Methodology and Implementation of the Largest mobile traffic control experiment to date"

Previous controlled experiments on single-lane ring roads have shown that a single partially autonomous vehicle (AV) can effectively mitigate traffic waves. This naturally prompts the question of how these findings can be generalized to field operational, high-density traffic conditions. To address this question, the Congestion Impacts Reduction via CAV-in-the-loop Lagrangian Energy Smoothing (CIRCLES) Consortium conducted MegaVanderTest (MVT), a live traffic control experiment involving 100 vehicles near Nashville, TN, USA. This article is a tutorial for developing analytical and simulation-based tools essential for designing and executing a live traffic control experiment like the MVT. It presents an overview of the proposed roadmap and various procedures used in designing, monitoring, and conducting the MVT, which is the largest mobile traffic control experiment at the time. The design process is aimed at evaluating the impact of the CIRCLES AVs on surrounding traffic. The article discusses the agent-based traffic simulation framework created for this evaluation. A novel methodological framework is introduced to calibrate this microsimulation, aiming to accurately capture traffic dynamics and assess the impact of adding 100 vehicles to existing traffic. The calibration model's effectiveness is verified using data from a six-mile section of Nashville's I-24 highway. The results indicate that the proposed model establishes an effective feedback loop between the optimizer and the simulator, thereby calibrating flow and speed with different spatiotemporal characteristics to minimize the error between simulated and real-world data. Finally, We simulate AVs in multiple scenarios to assess their effect on traffic congestion. This evaluation validates the AV routes, thereby contributing to the execution of a safe and successful live traffic control experiment via AVs.

Ameli, Mostafa↗

Apparatus for Testing Flat Specimens of Thermal Insulation

An apparatus has been developed to implement an improved method of testing flat-plate specimens of thermal-insulation materials for cryogenic application. The method includes testing under realistic use conditions that could include vacuum and mechanical loading at a pressure up to 70 psi (=0.48 MPa). The apparatus can accommodate a rigid or flexible specimen having thickness up to 1.25 in. (=3.2 cm) and diameters between 6 and 10 in. (about 15.2 and 25.4 cm, respectively). Typical test conditions include boundary temperatures between 77 K and 373 K and vacuum/interstitial gas filling at a pressure between 10(exp -6) torr (=1.3 x 10(exp -4) Pa) and 760 torr (atmospheric pressure =0.1 MPa). The interstitial gas could be N2, He, CO2, or any other suitable gas to which the insulation is expected to be exposed in use. Relative to prior apparatuses and testing methods, this apparatus and the testing method that it implements offer advantages of relative simplicity and ease of use. The basic principle of operation of the apparatus is that of boil-off calorimetry, using liquid nitrogen or any other suitable liquid that boils at a desired temperature below ambient temperature. Comparative rates of flow of heat through the thicknesses of the specimens (heat-leak rates) and apparent-thermal-conductivity values are obtained from tests of specimens. Absolute values of heat-leak rates and apparent thermal conductivities are computed from a combination of (1) the aforementioned comparative values and (2) calibration factors obtained by testing reference specimens of materials that have known thermal-insulation properties. The apparatus includes a full complement of temperature sensors, a vacuum pump and chamber, a monitoring and control system, and tools and fixtures that enable rapid and reliable installation and removal of specimens. A specimen is installed at the bottom of the vacuum chamber, and a cold-mass assembly that includes a tank is lowered into position above and around the specimen (see figure). A spring-based compensating fixture helps to ensure adequate thermal contact with possibly irregular specimen surfaces. For a high-compression test, the springs can be replaced with spacers. A flat circular load cell at the bottom of the chamber measures the compressive load on the specimen. Once the desired compressive-load, temperature, and vacuum/gas-filling conditions are established, testing begins. During a test, all measurements are recorded by use of a portable data-acquisition system and a computer. The total heat-leak rate is measured and calculated as the boil-off flow rate multiplied by the latent heat of vaporization. The parasitic heat leak (to the side of the specimen and to the top and side of the cold-mass tank) is reduced to a small fraction of the total heat leak by use of a combination of multilayer-insulation (MLI) shield rings, reflective film, a fiberglass/epoxy centering ring, and a bulk fill of aerogel beads. This combination eliminates the need for a cryogenic guard chamber used in a typical prior apparatus to reduce the parasitic heat leak.

Fesmire, James E.↗

Transfer learning for probabilistic localization of hidden cracks in concrete structures

Abstract The utility of discriminative supervised learning models built using multiple training-data sources is investigated for hidden crack localization in concrete. Feed-forward neural network (FFNN) is chosen as the model architecture, and transfer learning is used to assimilate the information obtained from different sources (computational physics simulations and laboratory experiments). The labeled training data consists of values of a damage index and the known locations of hidden cracks. The classification models need to learn how the presence of damage (hidden cracks) affects the damage index at different sensors for different test conditions. To this end, diagnostic FFNN models are built by sequentially adding and training new hidden layers to assimilate labeled information from computer models (different model geometries, test conditions, crack lengths, crack locations) and laboratory experiments on a plain cement slab. These transfer learning-based models are then used to localize damage in concrete specimens that reflect real-world conditions (i.e., specimens with steel reinforcement and randomly distributed aggregate). The actual damage state in these specimens is determined by extracting cores and performing petrographic studies on the extracted cores. The damage probability estimated by transfer learning-based models is compared with the petrographic damage rating index (DRI) to identify the most suitable approach to train the diagnostic models. The transfer learning-based diagnostic methodology shows promise and could be used in various structural health monitoring applications, where sufficient labeled data are typically not available from a single data source.

Miele, S.↗

In situ synchrotron study of electromigration induced grain rotations in Sn solder joints

In this paper we report an in situ study of the early stage of microstructure evolution induced by electromigration in a Pb-free β-Sn based solder joint by synchrotron polychromatic X-ray microdiffraction. With this technique, crystal orientation evolution is monitored at intragranular levels with high spatial and angular resolution. During the entire experiment, no crystal growth is detected, and rigid grain rotation is observed only in the two grains within the current crowding region, where high density and divergence of electric current occur. Theoretical calculation indicates that the trend of electrical resistance drop still holds under the present conditions in the grain with high electrical resistivity, while the other grain with low resistivity reorients to align its a-axis more parallel with the ones of its neighboring grains. A detailed study of dislocation densities and subgrain boundaries suggests that grain rotation in β-Sn, unlike grain rotation in high melting temperature metals which undergo displacive deformation, is accomplished via diffusional process mainly, due to the high homologous temperature.

36 MATERIALS SCIENCE↗

Catalyst Ammonia Storage Measurements Using Radio Frequency Sensing1

Motivated by increasingly strict nitrogen oxides (NOx) limits, engine manufacturers have adopted selective catalytic reduction (SCR) technology to reduce engine-out NOx. In the SCR process, NOx react with ammonia (NH3) to form nitrogen and water vapor. The reaction is influenced by several variables, including stored ammonia on the catalyst, exhaust gas composition, and catalyst temperature. Currently, measurements from NOx and/or NH3 sensors upstream and downstream of the SCR are used with predictive models to estimate ammonia storage levels on the catalyst and control urea dosing. This study investigated a radio frequency (RF)-based method to directly monitor the ammonia storage state of the SCR. This approach utilizes the catalyst as a cavity resonator, in which an RF antenna excites electromagnetic waves within the cavity to monitor changes in the catalyst state. Ammonia storage causes changes in the dielectric properties of the catalyst, which directly impacts the RF signal. Changes in the RF signal relative to stored ammonia (NH3) were evaluated over a wide range of frequencies, temperatures, and exhaust conditions. The RF response to NH3 storage, desorption, and oxidation on the SCR was well correlated with changes in the catalyst state. Calibrated RF measurements demonstrate the ability to monitor the adsorption state of the SCR to within 10% of the sensor full scale. The results indicate direct measurement of SCR ammonia storage levels, and resulting catalyst feedback control, via RF sensing to have significant potential for optimizing the SCR system to improve NOx conversion and decrease urea consumption.

Engineering↗

Long-Term Evaluation of Remedial Technology Performance in the Laboratory: Multi-year Experimental Test Plan

An understanding of the long-term effectiveness of remediation technologies is central to sustainable environmental cleanup. Long-term experiments are valuable for reducing uncertainty and predicting remediation outcomes at scales required for regulatory compliance. However, these types of tests can be costly and challenging to interpret. Therefore, contaminated sites often rely on short-term laboratory experiments that may not account for the potentially significant effects of gradual, time- dependent processes governing contaminant retention, release, and species transformation. For example, short-term lab experiments (from months to a year) conducted with sediments from the unsaturated and saturated zones at the Hanford Site play an important role in initial evaluations of remediation technologies but cannot capture the full extent of time-dependent reactions, leaving uncertainties in field-scale deployment. Here, long-term testing will be conducted on select technologies based on their performance in short-term testing. The overall objective is to directly address the challenges described above by generating and analyzing data on long-term (2–10 years) efficacy of selected remediation technologies, integrating this understanding into models, and providing critical input for remediation planning, monitoring, and 5-year review cycles for field-implemented remedies. Specific objectives include: 1. Evaluating long-term efficiency of promising remedies under site-specific conditions. 2. Generating robust parameters for modeling, reducing uncertainty in predictive simulations. 3. Advancing integrated monitoring by combining geochemical and geophysical observations. 4. Informing field-scale implementation by incrementally advancing technologies, identifying failure mechanisms early, and prioritizing robust, cost-effective remedies. Through systematic evaluation of technologies in laboratory-scale column experiments, integrated monitoring, and modeling support, this project is designed to bolster confidence in the long-term robustness of selected technologies. The ultimate outcome is the identification and deployment of more reliable, cost-effective remedies that safeguard human health and the environment while reducing the uncertainties that have historically hindered cleanup progress at Hanford Site. An experimental approach was developed and initiated for long-term testing potentially up to 10 years. The table below summarizes the experimental approach developed for testing select technologies and presented in this multi-year experimental test plan.

54 ENVIRONMENTAL SCIENCES↗